• 제목/요약/키워드: Evaporative Cooler

검색결과 37건 처리시간 0.026초

외기조건에 따른 제습냉방시스템의 성능 특성 (Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions)

  • 이대영;장영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.

  • PDF

열펌프, 데시칸트 및 증발식 냉각기를 조합한 하이브리드 냉방 시스템의 동특성 해석 연구 (Dynamic Simulation of a Hybrid Cooling System utilizing Heat Pump, Desiccant and Evaporative Cooler)

  • 서정남;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 2011
  • Hybrid desiccant cooling system(HDCS) consists of desiccant rotor, regenerative evaporative cooler, heat pump and district heating hot water coil. In this study, TRNSYS and EES, dynamic and steady simulation programs were used for studying hybrid desiccant cooling system which is applied to an apartment house from June to August. The results show that power consumption of the hybrid desiccant cooling system is 70 kWh in June, 199 kWh in July and 241 kWh in August. Sensible and latent heats removed by the hybrid desiccant cooling system are 300 kWh, 301 kWh in June, 610 kWh, 858 kWh in July and 719 kWh, 1010 kWh in August. COP of the hybrid desiccant cooling system is 8.6 in June, 7.4 in July and 7.2 in August. COP of the hybrid desiccant cooling system decreases when latent heat load increases. Operation time of the system is 70 hours in June, 190 hours in July and 229 hours in August. Since the cooling load is largest in August, the operation time of August is longest for maintaining the indoor temperature at $26^{\circ}C$. Due to the characteristics of hybrid desiccant cooling system for efficiently handling both sensible and latent loads, this system can handle sensible and latent heat loads efficiently in summer.

Biodegradation of toluene vapor by evaporative cooler model based biofilter

  • Vikrant, Kumar;Nagar, Harshil;Anand, Raja;Sharma, Anjney;Lee, Sang-Hun;Giri, Balendu Shekher;Kim, Ki-Hyun;Singh, Ram Sharan
    • 분석과학
    • /
    • 제31권2호
    • /
    • pp.57-64
    • /
    • 2018
  • The biodegradation of toluene vapor was investigated using a new type of biofilter equipped with a laboratory-scale evaporative cooler model packed with wood wool fibers (area: $360cm^2$). For the purpose of this study, the biofilter system was inoculated with Pseudomonas sp. RSST (MG 279053). The performance of this biofilter, assessed in terms of toluene removal efficiency (and elimination capacity), was as high as 99 % at a loading rate of $6g/h{\cdot}m^2$. The toluene removal efficiency decreased in an exponential manner with the increase in the loading rate. The cooler model-based biofilter was able to remove more than 99 % of toluene using Pseudomonas sp. RSST (MG 279053) as an effective inoculum. This biofilter is designed to operate under batch conditions for the removal of toluene in confined environments (e.g., automotive plants, boiler rooms in manufacturing facilities, and offshore drilling platforms).

알루미늄, 플라스틱, 플라스틱/종이 재질의 간접 증발 소자 성능 비교 (Performance Comparison between Indirect Evaporative Coolers made of Aluminum, Plastic or Plastic/Paper)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8165-8175
    • /
    • 2015
  • 여름철이 무더운 대한민국에서는 냉방에 많은 전력을 소비한다. 이 경우 간접증발냉각을 동시에 적용하면 전기 사용을 줄일 수 있다. 본 연구에서는 알루미늄, 플라스틱, 플라스틱/종이 재질로 만들어진 간접증발소자에 대하여 건표면 및 습표면 실험을 수행하였다. 실험 결과 플라스틱/종이 소자의 간접증발효율은 38.5% ~ 51.4%로 알루미늄 소자의 값 (41.9% ~ 47.5%)과 유사하고 플라스틱 소자의 값 (29.0% ~ 37.4%)보다는 높게 나타났다. 이로부터 저가의 플라스틱/종이 재질의 간접증발소자가 고가의 알루미늄 재질 간접증발소자를 대체할 수 있으리라 판단된다. 하지만 종이 채널의 압력손실은 알루미늄 채널의 압력손실보다 92% ~ 106% 크다. 한편 종이와 알루미늄 건채널의 열전달계수는 플라스틱 건채널의 값보다 15% ~ 44%, 185% ~ 203% 크게 나타났다. 반면 종이 건채널의 압력손실은 알루미늄 건채널 보다 93% ~ 106%, 플라스틱 건채널보다 34% ~ 48% 크게 나타났다. 습표면 해석결과 알루미늄 습채널에서는 17% ~ 23%, 플라스틱 습채널에서는 30% ~ 37%가 건표면으로 나타났다. 반면 종이 습채널의 경우는 100% 습표면으로 나타났다. 이는 종이의 흡습성이 알루미늄이나 플라스틱보다 월등하기 때문이다.

재생온도와 외기조건 변화에 따른 제습 냉방시스템의 냉방 성능 및 엑서지 해석에 관한 연구 (A Study on Cooling Performance and Exergy Analysis of Desiccant Cooling System in Various Regeneration Temperature and Outdoor Air Conditions)

  • 이장일;홍석민;변재기;최영돈;이대영
    • 대한기계학회논문집B
    • /
    • 제38권5호
    • /
    • pp.413-421
    • /
    • 2014
  • 제습 냉방시스템은 증발식 냉각기를 이용하여 공조 공기를 냉각하는 시스템으로 전기구동 냉각기 없이 열에너지만으로 냉방 공급을 수행할 수 있다. 따라서, CFC 계열의 냉매 사용에 의한 오존층 파괴 및 하절기 냉각기 가동에 의한 첨두 전력부하의 증가 등 기존의 냉방시스템이 야기하는 여러 가지 문제점들을 해결할 수 있다. 본 연구에서는 제습 냉방시스템의 효율을 향상시키기 위해 냉방 성능과 엑서지 해석을 수행하였다. 특히 열역학 제2법칙에 근거한 엑서지 해석을 이용할 경우 전체시스템과 구성요소에서의 엑서지 파괴의 원인을 분석함으로써 시스템의 효율과 관련된 주제에 대하여 더욱 본질적인 측면에서 접근할 수 있다. 본 연구의 목적은 재생온도와 외기조건의 변화에 따른 재생 증발식 냉각기를 이용한 제습 냉방시스템의 성능계수, 냉방용량, 엑서지 성능을 평가하는 것이다.

건물용 연료전지 기반 하이브리드 제습냉방시스템 성능 및 에너지 절감 분석 (Analysis of Performance and Energy Saving of a SOFC-Based Hybrid Desiccant Cooling System)

  • 인정현;이율호;강상규;박성진
    • 한국수소및신에너지학회논문집
    • /
    • 제30권2호
    • /
    • pp.136-146
    • /
    • 2019
  • A solid oxide fuel cell (SOFC) based hybrid desiccant cooling system model is developed to study the effect of fuel utilization rate of the SOFC on the reduction of energy consumption and $CO_2$ emission. The SOFC-based hybrid desiccant cooling system consists of an SOFC system and a Hybrid desiccant cooling system (HDCS). The SOFC system includes a stack and balance of plant (BOP), and HDCS. The HDCS consists of desiccant rotor, indirect evaporative cooler, electric heat pump (EHP), and heat exchangers. In this study, using energy load data of a commercial office building and SOFC-based HDCS model, the amount of ton of oil equivalent (TOE) and ton of $CO_2$ ($tCO_2$) are calculated and compared with the TOE and $tCO_2$ generation of the EHP using grid electricity.