• 제목/요약/키워드: Evaporation method

검색결과 1,103건 처리시간 0.022초

수중 하베스트형 빙축열시스템의 축방냉 특성 실험 (Experiment on the Charge and Discharge of Thermal Energy for Under-Water Harvest-Type Ice Storage System)

  • 김재돌
    • 한국태양에너지학회 논문집
    • /
    • 제22권2호
    • /
    • pp.11-17
    • /
    • 2002
  • This paper is concerned with the development of a new method for making, separating ice and storage floated ice by installing an evaporation plate at under-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating an ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. Developed new harvest-type method shows good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, however these components are not necessary in a new method. In this study ice storage systems are experimentally investigated to study the charge and discharge of thermal energy. The results show the applicable possibility and performance enhancement of a new type.

부직포 충전재의 구조적 특성이 수분전달 특성에 미치는 영향-단층구조와 이층구조 부직포의 비교- (The Effect of Geometrical Structure on the Moisture Transport Properties of Nonwoven Batting Materials)

  • 김희숙;나미희
    • 한국의류학회지
    • /
    • 제24권6호
    • /
    • pp.810-818
    • /
    • 2000
  • The purpose of this study was to analyze the effect of geometrical structure on the moisture transport properties of nonwoven batting materials. Two types of nonwovens were used such as single and double layered nonwovens. Steady and dynamic state water vapor transport properties were measured by absorption, evaporation and cobaltous chloride method respectively. The results of this study were as follows: 1) Geometrical structure affected water vapor evaporation, but there were no differences between single and double layered nonwovens in moisture absorption. Thickness and air permeability were influencing factor on water vapor transport rate. 2) Directionality of double layered nonwoven was observed both in steady and dynamic state moisture transport. There were differences between upper and lower layer of double layered nonwoven both in moisture absorption rate and color change by cobaltous chloride method. 3) In dynamic state of water vapor transport rate, single layered nonwoven reached more rapidly at the established relative humidity. It was confirmed that geometrical structure affected water vapor evaporation and hydrophilicity of fiber affected moisture absorption because there were much more water vapor transport rate by evaporation than absorption within the same period of time.

  • PDF

순차 스퍼터 법과 증발 법으로 제작한 박막의 특성 (Characteristics of Thin Films Fabricated by Using the Layer-by-Layer Sputtering and Evaporation Method)

  • 천민우;박용필;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 추계학술대회 논문집 Vol.16
    • /
    • pp.571-574
    • /
    • 2003
  • The thin films fabricated by using the layer-by-layer sputtering was compared with the thin film fabricated by using the evaporation method. Re-evaporation in the form of Bi atoms or $Bi_2O_3$ molecules easily bring out the deficiency of Bi atoms in thin film due to the long sputtering time of the layer-by-layer deposition. On the other hand, the respective atom numbers corresponding to BiSrCaCuO phase is concurrently supplied on the film surface in the evaporation deposition process and leads to BiSrCaCuO phase formation. Also, it is cofirmed that by optimizing the deposition condition, each single phase of the Bi2201 phase and the Bi2212 phase can be fabricated, the sticking coefficient of Bi element is clearly related to the changing of substrate temperature and the formation of the Bi2212 phase.

  • PDF

수평 평활관과 마이크로핀 관내에서 HFC-134a의 응축 및 증발열전달 특성 (Condensation and evaporation heat transfer characteristics of HFC-134a in a horizontal smooth and a micro-finned tube)

  • 이상천;박병덕;한운혁;이재희
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1725-1734
    • /
    • 1996
  • Experimental condensation and evaporation heat transfer coefficients were measured in a horizontal smooth tube and a horizontal micro-finned tube with HFC-134a. The test sections are straight, horizontal tubes with have a 9.52mm outside diameter and about 5000mm long. The micro-finned tube had 60 fins with a height of 0.12mm and a spiral angle of 25.deg.. The condensation test section was a double-pipe type with counter flow configuration. The evaporation test section employed an electic heating method. Enhancement factors which is defined as a ratio of the heat transfer coefficient for micro-finned tube to that for smooth tube, varied from 1.3 to 1.6(mass flux:110~190kg/m$^{2}$s) for condensation and 1.2 to 1.5 (mass flux:70~160kg/m$^{2}$s) for evaporation. The experimental data of condensation and evaporation heat transfer coefficients were compared to several empirical correlations. Based on these comparisons, modified correlations of the condensation and evaporation heat transfer coefficient for both smooth and micro-finned tubes were proposed.

감압증발법을 이용한 매립장 침출수 처리에 관한 연구 (A Study on Landfill Leachate Treatment by Reduced Pressure Evaporation.)

  • 문추연;은종극;이태호
    • 환경위생공학
    • /
    • 제12권3호
    • /
    • pp.73-79
    • /
    • 1997
  • This research was intended as an investigation of applying Reduced Pressure Evaporation as efficient treatment method for landfill leachate. According to the variance of time, temperature, pressure and pH in experiments, the properties of leachate treatment are follows. The removal efficiencies of COD, NH$_{3}$-N, TOC, Conductivity and SS on the basis of reaction time was 96.4%-97.5%, -1.4%-53.7%, 81.7%-89.0%, 92.0%-95.3% and 99.86%-99.97%, respectively. When the pH of Influent was 7.5, the pH of effluent was increased to 10-11 with time elapse. It is concluded that the orgin of pH increase may be ammonia. When the properties of concentrate were investigated at the concentration ratio 90%(V/V), concentration difficiency represented in the ratio of experimental value/calculated value had following orders ; COD>TOC>NH$_{3}$-N>Conductivity>SS. Concentrate had good precipitation because of additive thermal treatment in the process. When evaporation experiments with pH adjustment of 4.0, 6.0, 7.5, 9.0 and 10.0 were performed ; Acidic evaporation experiments(pH 4.0, 6.0) showed low removal efficiency(81.6, 87.6%) of COD and high removal efficiency (97.5%. 84.6%) of NH$_{3}$-N at initial evaporation. Basic evaporation(pH 9.0, 10.0) showed high removal efficiency (97.2%, 98.9%) of COD and very low removal efficiency (-7.4%, -27.2%) of NH$_{3}$-N at initial evaporation.

  • PDF

경험적 증발량 공식을 적용한 용담댐 시험유역의 수면증발량 추정 (Estimation of evaporation from water surface in Yongdam Dam using the empirical evaporation equaion)

  • 박민우;이주헌;임용규;권현한
    • 한국수자원학회논문집
    • /
    • 제57권2호
    • /
    • pp.139-150
    • /
    • 2024
  • 본 연구에서는 물리 기반 증발량 경험식인 Penman 혼합식(Penman combination equation, PCE)과 경험적인 바람 함수(Penman wind function, PWF)를 이용한 저수지 증발량 추정 방법을 제시하였다. 용담댐 시험유역에서 2016-2018년 기간의 실측 증발량 자료를 이용하여 두 가지 경험식에 매개변수를 추정하고 적용성을 검토하였다. 용담댐 시험유역 중 덕유산 플럭스 타워에서 PWF와 PCE에 대해 증발량을 평가한 결과, PWF 방법이 상관성 측면에서 더욱 개선된 결과를 보여주었지만, 두 가지 방법 모두 과대 추정 현상을 나타내었다. 용담호 수면 위에서 관측된 기상자료를 활용하여 PWF 방법을 통한 증발량을 평가하였으며, 관측 수면증발량과 통계적 지표 및 시각적 평가에서 우수한 성능을 확인하였다. 향후 본 연구를 통해 산정된 매개변수를 이용하여 저수지 수면 증발량을 간접적으로 추정할 수 있을 것으로 판단되나, 정확한 저수지 수면증발량 추정을 위해서는 타 댐들에 수면 증발량을 종합적으로 연계한 지역화 연구도 필요할 것으로 판단된다.

EVAPORATION DATA STOCHASTIC GENERATION FOR KING FAHAD DAM LAKE IN BISHAH, SAUDI ARABIA

  • Abdulmohsen A. Al-Shaikh
    • Water Engineering Research
    • /
    • 제2권4호
    • /
    • pp.209-218
    • /
    • 2001
  • Generation of evaporation data generally assists in planning, operation, and management of reservoirs and other water works. Annual and monthly evaporation series were generated for King Fahad Dam Lake in Bishah, Saudi Arabia. Data was gathered for period of 22 years. Tests of homogeneity and normality were conducted and results showed that data was homogeneous and normally distributed. For generating annual series, an Autoregressive first order model AR(1) was used and for monthly evaporation series method of fragments was used. Fifty replicates for annual series, and fifty replicates for each month series, each with 22 values length, were generated. Performance of the models was evaluated by comparing the statistical parameters of the generated series with those of the historical data. Annual and monthly models were found to be satisfactory in preserving the statistical parameters of the historical series. About 89% of the tested values of the considered parameters were within the assigned confidence limits

  • PDF

이란산 원유의 증발에 따른 풍화율 및 화학적 성상 변화 (Effects of Evaporation on the Weathering Rate and Chemical Composition of Iranian Heavy Crude Oil)

  • 김범;김기범;심원준;임운혁
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제15권3호
    • /
    • pp.238-246
    • /
    • 2012
  • 해양으로 유출된 유류는 다양한 풍화과정을 통해 환경에서 제거되며, 증발이 유출사고 초기에 가장 우세한 풍화과정이다. 본 연구에서는 허베이스피리트호 사고유 중 이란산 원유를 대상으로 실험실에서 표준화된 증발실험을 실시하여 시간에 따른 물리화학적 변화를 관찰하였다. 증발과정에 영향을 미치는 유막두께, 풍속 등의 변수를 제어하여 48시간까지 노출한 결과 $29.3{\pm}0.4%$의 재현성 있는 결과를 산출하였다(n=40, p<0.001). 미국해양대기청의 풍화모델인 ADIOS2를 이용하여 환경조건에서 증발을 시뮬레이션한 결과 29%의 증발율을 구할 수 있었으며, 본 실험과 일치하는 결과를 확인하였다. 증발율에 따른 원유의 조성변화를 분석한 결과 저분자량의 알칸과 PAHs가 제거되었으나, 바이오마커 화합물은 증발에 의한 영향을 받지 않는 보전적인 특성을 나타냈다. 바이오마커 중 $17{\alpha}(H)$, $21{\beta}(H)$-hopane을 이용한 풍화율 계산값은 48시간 최종 값이 24.4%로 물리적인 증발에 따른 양적변화와 유사한 결과를 보였다. 호판을 이용한 풍화율 계산값 비교결과 사고 초기 현장 표착유(1단계 풍화 28.9%)와 메소코즘 풍화 실험 5일차(26.5%)까지는 풍화과정이 주로 증발에 의한 것으로 확인되었다.

응축 증발법을 통한 서브마이크론 입자의 단극하전 특성 (Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method)

  • 최영주;김상수
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

동시 열증착법에 의한 $CdS_{1-x}Te_{1-x}$ 삼원계 다결정 박막의 제작과 특성 (Preparation and Characteristics of $CdS_{1-x}Te_{1-x}$ Ternary Polycrystalline Thin Films by Co-evaporation)

  • 박민서;송복식;정성훈;문동찬;김선태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.126-130
    • /
    • 1995
  • $CdS_{1-x}Te_{1-x}$ polycrystalline thin films were fabricated from CdS and CdTe powder by co-evaporation method at $10^{-6}$ Torr. The Optimum evaporation condition was substrate temperature $T_{s}$=$150^{\circ}C$, evaporation time t=30 min. XRD spectrums indicated that the crystal structure chanced from zinc blonde (x$\leq$0.22) to wurtzite (x$\geq$0.96) through mixed structure (0.22$\leq$0.74) as composition value x increase to CdS. Conductive type was n-type by hot point probe method. van der Pauw method was not applicable for x<0,5 due to high hall voltages, Electrical resistivity and Hall carrier mobility were decreased as x increase, while Hall carrier concentration was increased. The optical bandgap of $CdS_{1-x}Te_{1-x}$ polycrystalline thin films measure d at R.T. had quardratic form and the bowing parameter was fitted as 1.98eV for theoretical value of 2.0eV. I-V characteristics of In/CdTe/$CdS_{x}Te_{1-x}$Au Schottky diodes showed that CdS-rich one had better forward characteristics than CdTe-rich one.

  • PDF