• Title/Summary/Keyword: Evaporation efficiency

Search Result 428, Processing Time 0.027 seconds

Exergy Analysis of R744 OTEC Power Cycle with Operation Parameters (작동변수에 따른 R744용 해양온도차 발전 사이클의 엑서지 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1036-1042
    • /
    • 2012
  • This paper describes an analysis on exergy efficiency of R744 OTEC power system to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling and superheating degree, evaporation and condensation temperature, and turbine and pump efficiency, respectively. The main results are summarized as follows : As the evaporation temperature, superheating degree, and turbine and pump efficiency of R744 OTEC power system increases, the exergy efficiency of this system increases, respectively. But condensation temperature and subcooling degree of R744 OTEC power system increases, the exergy efficiency of this system decreases, respectively. The effect of evaporation temperature and pump efficiency on R744 OTEC power system is the largest and the lowest among operation parameters, respectively. Therefore, the refrigerant temperature in the evaporator must be closely to the surface seawater temperature to enhance the exergy efficiency of R744 OTEC power system.

Improvement of evaporating efficiency for OLED mass-fabrication

  • Lee, Eung-Ki;Jeong, Seong-Ho;Jeong, Seok-Heon;Huh, Myung-Soo;Lee, Sung-Ho;Chung, Sung-Jin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.728-731
    • /
    • 2002
  • For the evaporation process, thickness uniformity is of great practical importance. And, it is commercially significant to improve the efficiency of material of the evaporant which is deposited on the substrate because of high price of organic materials. To achieve the better thickness uniformity and the higher evaporating efficiency, Samsung SDI has introduced the new concept of the asymmetric evaporation technology for depositing evener and cheaper organic layers. Based on the developed method, the uniformity of the organic layer thickness can be successfully controlled. Furthermore, the very high efficiency may allow the OLED displays be manufactured with the lower cost.

  • PDF

The Analysis of the Discharging Characteristics and MgO protective layer by MgO Evaporation Rates for High-Efficiency PDP (MgO 증착률에 따른 PDP 보호막 물성 및 방전 특성 분석)

  • Kim, Yong-Jae;Kwon, Sang-Jik
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.3
    • /
    • pp.181-186
    • /
    • 2007
  • We have investigated and analyzed the effects of the evaporation rate of MgO films on the MgO properties and the discharge characteristics of a plasma display panel(PDP). The MgO properties such as the crystal orientation, the surface roughness, the film structure, and cathode-luminescence (CL) spectra were inspected using XRD (X-ray diffraction), AFM(atomic force microscopy). And the discharging characteristics of the PDP such as the firing voltage, discharging current, and luminescence were measured using a vacuum chamber with oscilloscope (TDS 540C), current probe (TCP-312A), color meter (CS-100A) and etc. From the experiments results we confirmed the optimum evaporation rate at $5{\AA}/sec$, the MgO properties were shown to be strongly dependent on the evaporation rate, and the MgO properties had an effecton the optical and electrical characteristics. In other words, if the evaporation rates increase than $5{\AA}/sec$, the intensity of (200) orientation and cathode-luminescence (CL) spectra reduce, and the firing vlotage was increased. So the luminuous efficiency grows worse.

A Study on Discharge Characteristics of the PDP Packaged with In-situ Vacuum Sealing with the MgO Protective Layer Deposited by Optimal Evaporation Rate (최적 증착 속도로 형성된 MgO를 갖는 인-라인 진공 실장된 플라즈마 디스플레이 패널의 방전 특성에 관한 연구)

  • Li, Zhao-Hui;Cho, Eou-Sik;Kwon, Sang-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.916-922
    • /
    • 2008
  • AC PDP with MgO protective layer coated with the optimum evaporation rate of $5{\AA}/s$ can generate more enhanced efficiency through the vacuum in-line sealing process. However, the optimized process conditions still require the optimum driving scheme on the ramp-up and ramp-down slope of the reset waveform for enhancing the efficiency. In this paper, for the in-situ vacuum sealed PDP with the optimum evaporation rate of MgO protective layer, the address delay time was investigated with various slopes of ramp waveform during a reset ramp-up and ramp-down period. In this study, the minimum statistical delay time was obtained at the ramp-up rate of $6.0 V/{\mu}s$ and the ramp-down rate of $0.7 V/{\mu}s$ of the reset waveform.

Sludge Drying Method Using Microwave Drying Device and Heat Transfer Medium Oil (마이크로웨이브와 열전매체유를 이용한 슬러지 건조방법)

  • Kim, Yong-Ryul;Son, Min-Il
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.367-373
    • /
    • 2011
  • This research is a basic researching process for producing solid fuel that mixing paper sludge and Heat Transfer Medium Oil. Under the presence of Heat Transfer Medium Oil, paper sludge is heated and dried with home appliance microwave for comparing drying efficiency and energy efficiency of different types of drying method. As a result, Heat Transfer Medium Oil and paper mixing case of drying method, OMD, is the most efficient way to shorten the time for evaporating moisture in the paper sludge. In addition, heat transfer effect and density is increased with adding Heat Transfer Medium Oil by microwave. Future more, OMD's energy cost for evaporating whole moisture is 78% cheaper than MD. Also, OMD process shows the best energy efficiency with comparing other process. Evaporation rate of paper sludge evaporation process with microwave is 11.66% increased by adding Heat Transfer Medium Oil 150g. Preheating Heat Transfer Medium Oil or improving different ways injecting Heat Transfer Medium Oil is a good way to increase a rate of initiative moisture evaporation process.

Preparation of Resveratrol-loaded Poly($\varepsilon$-caprolactone) Nanoparticles by Oil-in-water Emulsion Solvent Evaporation Method

  • Kim, Bum-Keun;Lee, Jun-Soo;Oh, Ju-Kyoung;Park, Dong-June
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.157-161
    • /
    • 2009
  • Resveratrol-loaded poly($\varepsilon$-caprolactone) (PCL) nanoparticles were prepared by oil in water (O/W) emulsion solvent evaporation method. The morphology of the nanoparticles was evaluated using atomic force microscope (AFM), in which well-shaped and rigid nanoparticles were prepared. The mean particle size of nanoparticles prepared using only dichloromethane (DCM) ($523.5{\pm}36.7\;nm$) was larger than that prepared with a mixture of DCM and either ethanol (EtOH) ($494.5{\pm}29.2\;nm$) or acetone ($493.5{\pm}6.9\;nm$). The encapsulation efficiency of nanoparticles prepared only with DCM as dispersed phase ($78.3{\pm}7.7%$) was the highest of those prepared with solvent mixtures. An increase in the molecular weight of PCL led to an increase in encapsulation efficiency (from $78.3{\pm}7.7$ to $91.4{\pm}3.2%$). Pluronic F-127 produced the smallest mean size ($523.5{\pm}36.7\;nm$) with the narrowest particle size distribution. These results show that dispersed phase, molecular weight of wall materials, emulsion stabilizer could be important factors to affect the properties of nanoparticles.

Study on the evaporation Heat Transfer Characteristics of R-134a in Small Diameter Tubes

  • Roh, Geon-Sang;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.3
    • /
    • pp.224-234
    • /
    • 2007
  • Large diameter tubes have been used until comparatively lately. However, small diameter tubes are largely used because of their high efficiency in heat transfer and low cost, recently. This study focuses on the experimental research of the heat transfer coefficients during evaporation process of R-22 and R-134a in small diameter tubes. The evaporation heat transfer coefficients were measured in smooth horizontal copper tubes with ID 1.77, 3.36 and 5.35 mm. The evaporation heat transfer coefficients in the small diameter tubes (ID <7 mm) were observed to be strongly affected by the size of tube diameters and to differ from those of general predictions in the large diameter tubes. The heat transfer coefficients of ID 1.77 mm copper tube were higher by 20 and 30 % than those of ID 3.36 mm, ID 5.35 mm copper tubes respectively. Also, it was found that it was very difficult to apply some well-known previous predictions (Shah's, Jung's. Kandlikar's and Oh-Katsuda's correlation) to small diameter tubes. Based on the data, the new correlation is proposed to predict the evaporation heat transfer coefficients of R-22 and R-134a in small diameter tubes.

A new method fast measure cryogenic vessel heat leakage

  • LI, Zheng-Qing;LI, Xiao-Jin;LIU, Mo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.1
    • /
    • pp.24-28
    • /
    • 2020
  • Heat leakage is an important parameter to reflect heat insulated performance of cryogenic vessel. According to the current standard requirements, it needs to measure the daily evaporation rate to indicate heat leakage. The test needs-over 24h after cryogenic vessel in heat equilibrium as standard required, therefore test efficiency is poor and new efficient method is required to cut test time. First of all, the volume of instantaneous evaporated gas and heat leakage are calculated by the current standard corresponding to the maximum allowable daily evaporation rate of cryogenic vessel. Depending on the relationship between real daily evaporation rate and maximum allowable daily evaporation rate of cryogenic vessel, we designed a new test method based on the pressure changes over time in cryogenic vessel to determine whether its heat insulated performance meets requirements or not. Secondly, the heat transfer process was analyzed in measurement of cryogenic vessel, and the heat transfer equations of whole system were established. Finally, the test was completed in four hours; meanwhile the heat leakage and daily evaporation rate of cryogenic vessel are calculated basing on test data.

Analysis of PDP Discharging Properties Depending on Electron Beam Evaporation Rate of MgO Layer (MgO의 전자선 증착율에 따른 PDP 방전 특성 분석)

  • Kim, Yong-Jae;Kwon, Sang-Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.716-719
    • /
    • 2007
  • The effects of the evaporation rate of MgO films using an electron beam on the MgO properties and the discharge characteristics of a plasma display panel (PDP) were investigated and analyzed. MgO films were deposited with the various MgO evaporation rates. The MgO properties such as the crystal orientation, the surface roughness, and the film structure were inspected using XRD (X-ray diffraction), AFM (atomic force microscopy). From the experiments and Paschen law, the maximum value of the secondary electron emission coefficient $({\gamma})$ was obtained at the evaporation rate of $5{\AA}/sec$. The XRD results and cathode-luminescence (CL) spectra show the ${\gamma}$ values are correlated with F/F+ centers of the molecular structure of MgO films. The minimum firing voltage and the maximum luminous efficiency were obtained at an evaporation rate of $5{\AA}/sec$. In the MgO film deposited at $5{\AA}/sec$, the (200) orientation and F+ center were most intensive.

Continuous Treatment of Piggery Slurry using the Thermophilic Aerobic Oxidation (TAO) System (급속액상부숙기술(TAO system)을 이용한 양돈분뇨의 연속처리)

  • 이원일;이명규
    • Journal of Animal Environmental Science
    • /
    • v.6 no.3
    • /
    • pp.169-174
    • /
    • 2000
  • TAO system was applied to treatment of piiggery slurry. In the experiments, the volume of influx was differentiated in four types. The features of operation, evaporation rate, and efficiency of successive treatment were drawn. The results are; 1. During the operation, the inside temperature was maintained at over $60^{\circ}C$ with the highest $70.2^{\circ}C$. 2. The evaporation rate of influx volume was 31.4%. And the evaporation volume of per square meter was $108{\;}\ell/\textrm{m}^2$; slightly different from $120{\;}\ell/\textrm{m}^2$ of batch type. 3. The VFAs was decreased by 95% (from $1,538lmg/{\ell}$ in influx to $72.9mg/{\ell}$ in Efflux). Thus, successive operation of TAO system is considered to be possible.

  • PDF