• 제목/요약/키워드: Evaporation efficiency

검색결과 426건 처리시간 0.029초

PDP 효율 및 생산성 향상을 위한 공정단순화 기술 (Process TAC Time Reduction Technology for Improving the Efficiency and Throughput of the PDP)

  • 권상직
    • 반도체디스플레이기술학회지
    • /
    • 제12권2호
    • /
    • pp.45-50
    • /
    • 2013
  • This paper focuses on the fundamental issues for improving the efficiency and throughput of the AC PDP (Plasma Display Panel) manufacturing. The properties of the MgO protective layer affect the PDP efficiency. Especially, the secondary electron emission efficiency was affected on the deposition rate of MgO during the evaporation. In this study, the deposition rate of 5 $\AA$/s has given the maximum efficiency value of 0.05 It is demonstrated that the impurity gases such as $H_2O$, $CO_2$, CO or $N_2$, and $O_2$ can be remained inside the PDP panel before sealing and the amount of the impurity gases decreased rapidly as the base vacuum level increased, especially near $10^{-5}$ torr. The fundamental solution in order to overcome these problems is the vacuum in-line sealing process from the MgO evaporation to the final sealing of the panel without breaking the vacuum. We have demonstrated this fundamental process technology and shown the feasibility. The firing voltage was reduced down to 285 V at the base vacuum value of $10^{-6}$ torr, whreras it was about 328 V at the base vacuum value of $10^{-3}$ torr.

Se원소의 증발조건이 Cu(InGa)Se$_2$ 박막 태양전지 특성에 미치는 영향 (Characterization of Cu(InGa)Se$_2$ Solar Cells with Se Evaporation Conditions)

  • 김석기;이정철;강기환;윤경훈;박이준;송진수;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2002
  • Polycrystalline Cu(In,Ga)Se$_2$(CIGS) thin-films were grown by co-evaporation on a soda lime glass substrate. In this paper the effects of the Se evaporation temperature on the properties of CuIn0.75Ga0.25Se2 (CIGS) thin films. Structure, surface morphology and optical properties of CIGS thin films deposited at various Se evaporation temperatures have been investigated using a number of analysis techniques. X-ray diffraction (XRD) analysis shows that CIGS films exhibit a strong <112> preferred orientation. As expected, at higher Se evaporation temperatures the films displayed a lower degree of crystallinity. The <112> peak was also enhanced and other CIGS peaks appeared simultaneously. These results were supported by experimental work using scanning electron microscopy When the Se evaporation temperature was increased, the average grain size also decreased together with a reduction Cu content. The Se evaporation temperature also had a significant inf1uence on the transmission spectra. Increasing the Se evaporation temperature, the cell efficiency was improved dramatically to 11.75% with Voc = 556 mV, Jsc = 32.17 mA/cm2 and FF = 0.66. The Se evaporation temperature is an important parameter in thin film deposition regardless of the deposition technique being used to deposit thin films

  • PDF

가습연소 폐열회수 보일러의 물분사 설계모델 구축에 관한 연구 (Establishing the Models for Optimized Design of Water Injection in Boilers with Waste-heat-recovery System)

  • 신재훈;문석수
    • 한국분무공학회지
    • /
    • 제26권2호
    • /
    • pp.96-103
    • /
    • 2021
  • In order to improve the overall efficiency and meet the emission regulations of boiler systems, the heat exchanging methods between inlet air and exhaust gas have been used in boiler systems, named as the waste-heat-recovery condensing boiler. Recently, to further improve the overall efficiency and to reduce the NOx emission simultaneously, the concept of the water injection into the inlet air is introduced. This study suggests the models for the optimized design parameters of water injection for waste-heat-recovery condensing boilers and performs the analysis regarding the water injection amount and droplet sizes for the optimized water injection. At first, the required amount of the water injection was estimated based on the 1st law of thermodynamics under the assumption of complete evaporation of the injected water. The result showed that the higher the inlet air and exhaust gas temperature into the heat exchanger, the larger the amount of injected water is needed. Then two droplet evaporation models were proposed to analyze the required droplet size of water injection for full evaporation of injected water: one is the evaporation model of droplet in the inlet air and the other is that on the wall of heat exchanger. Based on the results of two models, the maximum allowable droplet sizes of water injection were estimated in various boiler operating conditions with respect to the residence time of the inlet air in the heat exchanger.

단일액적의 증발 및 착화특성에 관한 연구 (A Study of Evaporation and Ignition Characteristics of Single Fuel Droplet)

  • 백병준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권4호
    • /
    • pp.551-559
    • /
    • 1998
  • Evaporation and ignition characteristics of fuel droplet have major influences on the efficiency and performance of engine. In the present study the experiment of evaporation and self-ignition of single fuel was performed under the various ambient conditions. An individually suspended droplet of n-heptane n-hexadecane ethyl-alcohol and light oil were employed as a liquid droplet. Evaporation and ignition characteristics were measured by using the video-camera and image processing technique under the various ambient temperatures (up to 1000310 OC)and partial pressure of oxigen(up to 60%) The evaporation curve shows that the droplet life time ignition delay time decreases as the ambient temperature and partial pressure of oxigen increase, The temperature variations of droplet were also reported for various fuel and ambient temperatures. The numerical simulations were carried out to predict droplet diameter and temperature with favorable agreement.

  • PDF

The development of the highly efficient Circular Nozzle Source by using a study on the flux distributions of nozzle type thermal evaporation sources

  • Kim, Sung-Moon;Jeong, Kwang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1171-1174
    • /
    • 2008
  • We studied the properties of vapor flux distributions of nozzle shaped thermal evaporation sources and the factors, which can change the flux distributions such as nozzle structure. We used a simulation and experiment methods for this study. By using the results of our study, we improved the Circular Nozzle Source, which can make uniform thin films without substrate rotation, into more efficient source.

  • PDF

고효율 Evaporation법을 이용한 차세대 OLED 증착기 (OLED Equipment for Next Generation using High Efficiency Evaporation Method)

  • 박영호;김종운
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 춘계학술발표회 초록집
    • /
    • pp.12-13
    • /
    • 2007
  • OLED는 유기물을 이용한 진공 증발 증착법(Evaporation)에 의해 제조하고 있으며, 2세대 기판을 사용하고 있는 현재의 개념으로는 유기물 증착 효율이 수 %에 그치고 증착속도도 수 A/s로 상당히 낮다. OLED 제조의 생산성을 향상하기 위해서 증착속도로 10A/s이상, 제조 단가를 줄이기 위해 재료의 효율도 30% 이상으로 향상시킬 수 있었다.

  • PDF

하절기 기화냉각장치 설치에 따른 가스터빈 성능변화 (Performance Change of Gas Turbine with a Evaporation Cooling System in Summer Season)

  • 정현조;유호선;문승재
    • 플랜트 저널
    • /
    • 제13권1호
    • /
    • pp.37-43
    • /
    • 2017
  • 본 연구는 하절기 가스터빈 압축기 입구에 설치된 기화냉각장치로 인하여 저하된 공기온도가 가스터빈 성능에 어떠한 변화를 미치는지에 대하여 해석하였다. 연구 대상은 인천화력본부 가스터빈 3호기이며, 기종은 Siemens SGT6-4000F(V 84.3A)이다. 기화냉각장치 설치 전후를 비교하기 위하여 특설계측기를 설치하였으며, 2015년 8월 3일에서 14일까지 11시부터 15시 사이에 대기온도 $29{\pm}1^{\circ}C$ 조건에서 설치 전후 각각 5회씩 총 10회에 걸쳐 정밀성능시험을 시행하고 각각의 평균값을 적용하였다. 시험 결과, 가스터빈 압축기 입구 공기온도 $4.12^{\circ}C$ 저하로 공기 밀도가 증가되어 압축기 압력비는 0.27 증가, 압축기 효율은 0.29 %p 상승, 가스터빈 엔탈피강하 효율은 0.31 %p 증가하였고, 가스터빈 효율은 0.44%p, 출력은 4,489 kW가 증대되는 효과를 얻을 수 있었으며, 습도 및 유동저항 증가에 따른 영향은 미미하였다.

  • PDF

응축 및 증발 부하에 따른 냉동시스템 특성에 관한 연구 (A Study on the Characteristics of Refrigerating System according to the Condensation and Evaporation Load)

  • 최승일;지명국;이대철;정효민;정한식
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.44-49
    • /
    • 2013
  • The refrigerating system are high efficiency and comfortable due to the automation of the system as well as enhance energy saving are contributing to driving system. Previous study the rotational frequency of the compressor was confined to the fixed condition have changed load of evaporator and condenser related about the refrigerator performance characteristic according to the evaporation load and condensation load change tries to be analyze through the experiment. The useful data for the economic driving of the freezing apparatus tries to be drawn. Consequently, it confirmed that refrigerant in the compressor overheated and as the evaporation load increased the specific volume was increased and the coolant circulation rate decreased. In confirmed that condensation load increased the compression ratio and discharge gas temperature increased. It reduced the low-temperature efficiency and condensation calorie and the quality factor was decreased.

자열증발된 액체연료를 적용한 원통형 예혼합 연소기의 연소특성 (Combustion Characteristics of Cylindrical Premixed Combustor using Liquid Fuel by Self Evaporation)

  • 이필형;송기종;황상순
    • 한국연소학회지
    • /
    • 제21권3호
    • /
    • pp.7-15
    • /
    • 2016
  • The fuel in conventional liquid fuel combustor is atomized by spray method for high efficiency and low emissions. To improve the overall fuel efficiency and lower pollutant emissions in liquid fuel combustion systems, the effective spatial and temporal separation of droplet evaporation from normal spray process is needed. In this paper, the recuperation of high temperature burnt gas for fuel evaporation was proposed to develop a cylindrical premixed combustor. The recuperation process using U shaped tube is effective to evaporate the liquid fuel. The results show that the flame mode is changed into red radiation flame, blue flame and lift off flame with decreasing equivalence ratio as gas fuel combustion mode. In particular, the blue flame is found to be very stable at heating load 9.2 kW and equivalence ratio 0.731. NOx was measured blow 105 ppm ($O_2$ zero base) from equivalence ratio 0.705 to 0.835. CO which is a very important emission index in liquid fuel combustor was observed below 5 ppm ($O_2$ zero base) under the same equivalence region.

E-Beam evaporation을 이용한 전극 형성 공정이 결정질 실리콘 태양전지에 미치는 영향 분석 (Effect of Electrode Formation Process using E-beam Evaporation on Crystalline Silicon Solar Cell)

  • 최동진;박세진;신승현;이창현;배수현;강윤묵;이해석;김동환
    • Current Photovoltaic Research
    • /
    • 제7권1호
    • /
    • pp.15-20
    • /
    • 2019
  • Most high-efficiency n-type silicon solar cells are based on the high quality surface passivation and ohmic contact between the emitter and the metal. Currently, various metalization methods such as screen printing using metal paste and physical vapor deposition are being used in forming electrodes of n-type silicon solar cell. In this paper, we analyzed the degradation factors induced by the front electrode formation process using e-beam evaporation of double passivation structure of p-type emitter and $Al_2O_3/SiN_x$ for high efficiency solar cell using n-type bulk silicon. In order to confirm the cause of the degradation, the passivation characteristics of each electrode region were determined through a quasi-steady-state photo-conductance (QSSPC).