• Title/Summary/Keyword: Evaluation-Methods

Search Result 15,870, Processing Time 0.047 seconds

Evaluation of Myocardial Oxygen Consumption with $^{11}C$-Acetate and 3D PET/CT: By Applying Recirculation Correction Method and Modified One-Compartmental Tracer Kinetic Modeling ($^{11}C$-Acetate와 3차원 PET/CT를 이용한 심근의 산소 소모량 평가: 재순환 교정법 및 수정 단일구획 추적자 동적 모델 적용)

  • Chun, In-Kook;Hwang, Kyung-Hoon;Lee, Sang-Yoon;Kim, Jin-Su;Lee, Jae-Sung;Shin, Hee-Won;Lee, Min-Kyung;Yoon, Min-Ki;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.275-284
    • /
    • 2008
  • Purpose: We intended to evaluate myocardial oxygen consumption ($MVO_2)$ by applying recirculation correction and modified one-compartment model to have a reference range of $MVO_2$ in normal young population and to reveal the effect of recirculation on time-activity curve (TAC). Materials and Methods: In nine normal male volunteers with mean age of $26.3{\pm}4.0$, $MVO_2$ was estimated with 925 MBq (25mCi) of $^{11}C$-Acetate (Neuroscience Research Institute, Gachon University of Medicine and Science, Incheon, Korea) and PET/CT (Biograph 6, Siemens Medical Solution, Germany). Analysis software such as $MATLAB^{(R)}$ v7.1 (Mathworks, Inc., United States), $Excel^{(R)}$ 2007 (Microsoft, United States), and $SPSS^{(R)}$ v12.0 (Apache Software Foundation, United States) were used. Twenty three frames were of $12{\times}10$, $5{\times}60$, $3{\times}120$, $2{\times}300's$ duration, respectively. The modified one-compartmental model and the recirculation correction method were applied. Statistical analysis was performed by using Test of Normality, ANOVA and Post-Hoc (Scheffe's) analysis, and p-value less than 0.05 was considered as significant. Results: The normal reference ranges of $MVO_2$ were presented as $3.18-4.64\;{\times}\;10^{-4}\;ml/g/sec$, $1.91-3.94\;{\times}\;10^{-4}\;ml/g/sec$, $4.31-6.40\;{\times}\;10^{-4}\;ml/g/sec$, $2.84-4.53\;{\times}\;10^{-4}\;ml/g/sec$ and $3.42-5.00\;{\times}\;10^{-4}\;ml/g/sec$ in the septum, the inferior wall, the lateral wall, the anterior wall and the entire wall, respectively. In addition, it was noted that the dual exponentiality of the clearance curve is due to the recirculation effect and that the characteristic of the curve is essentially mono-exponential. Conclusion: $^{11}C$-Acetate is a radiotracer worthwhile to assess $MVO_2$. Re-circulated $^{11}C$ can influence TAC of $^{11}C$ in myocadia and so the recirculation correction must be considered when measuring $MVO_2$.

The Evaluation of Dynamic Continuous Mode in Brain SPECT (Brain SPECT 검사 시 Dynamic Continuous Mode의 유용성 평가)

  • Park, Sun Myung;Kim, Soo Yung;Choi, Sung Wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.15-22
    • /
    • 2017
  • Purpose During Brain SPECT study, critical factor for proper study with $^{99m}Tc-ECD$ or $^{99m}Tc-HMPAO$ is one of the important causes to patent's movement. It causes both improper diagnosis and examination failure. In this study, we evaluated the effect of Dynamic Continuous Mode Acquisition compared to Step and Shoot Mode to raise efficacy and reject the data set with movement, as well as, be reconstructed in certain criteria. Materials and Methods Deluxe Jaszczak phantom and Hoffman 3D Brain phantom were used to find proper standard data set and exact time. Step and Shoot Mode and Dynamic Continuous Mode Acquisition were performed with SymbiaT16. Firstly, Deluxe Jaszczak phantom was filled with $Na^{99m}TcO_4$ 370 MBq and obtained in 60 minutes to check spatial resolution compared with Step and Shoot Mode and Dynamic Continuous Mode. The second, the Hoffman 3D Phantom filled with $Na^{99m}TcO_4$ 74 MBq was acquired for 15 Frame/minutes to evaluate visual assessment and quantification. Finally, in the Deluxe Jaszczak phantom, Spheres and Rods were measured by MI Apps program as well as, checking counts with the frontal lobe, temporal lobe, occipital lobe, cerebellum and hypothalamus parts was performed in the Hoffman 3D Brain Phantom. Results In Brain SPECT Study, using Dynamic Continuous Mode rather than current Step and Shoot Mode, we can do the reading using the 20 to 50 % of the acquired image, and during the test if the patient moves, we can remove unneeded image to reduce the rate of restudy and reinjection. Conclusion Dynamic Continuous Mode in Brain study condition enhances effects compared to Step and Shoot Mode. And also is powerful method to reduce reacquisition rate caused by patient movement. The findings further indicate that it suggest rejection limit to maintain clinical value with certain reconstruction factors compared with Tomo data set. Further examination to improve spatial resolution, SPECT/CT should be the answer for that.

  • PDF

Characteristics of the Differences between Significant Wave Height at Ieodo Ocean Research Station and Satellite Altimeter-measured Data over a Decade (2004~2016) (이어도 해양과학기지 관측 파고와 인공위성 관측 유의파고 차이의 특성 연구 (2004~2016))

  • WOO, HYE-JIN;PARK, KYUNG-AE;BYUN, DO-SEONG;LEE, JOOYOUNG;LEE, EUNIL
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.23 no.1
    • /
    • pp.1-19
    • /
    • 2018
  • In order to compare significant wave height (SWH) data from multi-satellites (GFO, Jason-1, Envisat, Jason-2, Cryosat-2, SARAL) and SWH measurements from Ieodo Ocean Research Station (IORS), we constructed a 12 year matchup database between satellite and IORS measurements from December 2004 to May 2016. The satellite SWH showed a root mean square error (RMSE) of about 0.34 m and a positive bias of 0.17 m with respect to the IORS wave height. The satellite data and IORS wave height data did not show any specific seasonal variations or interannual variability, which confirmed the consistency of satellite data. The effect of the wind field on the difference of the SWH data between satellite and IORS was investigated. As a result, a similar result was observed in which a positive biases of about 0.17 m occurred on all satellites. In order to understand the effects of topography and the influence of the construction structures of IORS on the SWH differences, we investigated the directional dependency of differences of wave height, however, no statistically significant characteristics of the differences were revealed. As a result of analyzing the characteristics of the error as a function of the distance between the satellite and the IORS, the biases are almost constant about 0.14 m regardless of the distance. By contrast, the amplitude of the SWH differences, the maximum value minus the minimum value at a given distance range, was found to increase linearly as the distance was increased. On the other hand, as a result of the accuracy evaluation of the satellite SWH from the Donghae marine meteorological buoy of Korea Meteorological Administration, the satellite SWH presented a relatively small RMSE of about 0.27 m and no specific characteristics of bias such as the validation results at IORS. In this paper, we propose a conversion formula to correct the significant wave data of IORS with the satellite SWH data. In addition, this study emphasizes that the reliability of data should be prioritized to be extensively utilized and presents specific methods and strategies in order to upgrade the IORS as an international world-wide marine observation site.

Transfer and Validation of NIRS Calibration Models for Evaluating Forage Quality in Italian Ryegrass Silages (이탈리안 라이그라스 사일리지의 품질평가를 위한 근적외선분광 (NIRS) 검량식의 이설 및 검증)

  • Cho, Kyu Chae;Park, Hyung Soo;Lee, Sang Hoon;Choi, Jin Hyeok;Seo, Sung;Choi, Gi Jun
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.81-90
    • /
    • 2012
  • This study was evaluated high end research grade Near infrared spectrophotometer (NIRS) to low end popular field grade multiple Near infrared spectrophotometer (NIRS) for rapid analysis at forage quality at sight with 241 samples of Italian ryegrass silage during 3 years collected whole country for evaluate accuracy and precision between instruments. Firstly collected and build database high end research grade NIRS using with Unity Scientific Model 2500X (650 nm~2,500 nm) then trim and fit to low end popular field grade NIRS with Unity Scientific Model 1400 (1,400 nm~2,400 nm) then build and create calibration, transfer calibration with special transfer algorithm. The result between instruments was 0.000%~0.343% differences, rapidly analysis for chemical constituents, NDF, ADF, and crude protein, crude ash and fermentation parameter such as moisture, pH and lactic acid, finally forage quality parameter, TDN, DMI, RFV within 5 minutes at sight and the result equivalent with laboratory data. Nevertheless during 3 years collected samples for build calibration was organic samples that make differentiate by local or yearly bases etc. This strongly suggest population evaluation technique needed and constantly update calibration and maintenance calibration to proper handling database accumulation and spread out by knowledgable control laboratory analysis and reflect calibration update such as powerful control center needed for long lasting usage of forage analysis with NIRS at sight. Especially the agriculture products such as forage will continuously changes that made easily find out the changes and update routinely, if not near future NIRS was worthless due to those changes. Many research related NIRS was shortly study not long term study that made not well using NIRS, so the system needed check simple and instantly using with local language supported signal methods Global Distance (GD) and Neighbour Distance (ND) algorithm. Finally the multiple popular field grades instruments should be the same results not only between research grade instruments but also between multiple popular field grade instruments that needed easily transfer calibration and maintenance between instruments via internet networking techniques.

Quality characteristics of distilled spirits by different nuruk-derived yeast (누룩 유래 효모의 종류에 따른 증류주의 품질 특성)

  • Lee, Ae-Ran;Kang, Sun-Hee;Kim, Hye-Ryun;Lee, Jang-Eun;Lee, Eun-Jung;Kim, Tae-Wan
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.4
    • /
    • pp.383-389
    • /
    • 2017
  • This study aimed to select a yeast strain for optimizing the quality of distilled spirits. The brewing and distilling properties of 4 KFRI (Korea Food Research Institute) yeasts (Y88-4, Y98-4, Y172-6, Y192-4) and 2 industry yeasts (C1, C2) were compared. For investigating the possibility of using these strains on an industrial scale, diverse analytical methods were applied to assess parameters associated with distilled spirit quality such as alcohol content, pH, total acidity, and soluble solid content. After 11 days of fermentation, the alcohol strength obtained using six yeast strains reached 13.9-16.4% (v/v), while pH was 3.9-4.0, and total acid was 0.40-0.52%. To compare GC-MSD Volatile flavor components, all the distilled spirit samples were diluted to 20% (v/v) alcohol strength. Seven fusel alcohols, 26 esters, 2 acids, and 3 miscellaneous compounds were detected in the distilled spirits. Y88-4 had the most abundant volatile flavor component and scored the highest overall preference in sensory evaluation. After analyzing the various properties of yeasts, strain Y88-4 was finally selected as the best strain for producing distilled spirits.

The Knowledge and Attitude of Unmarried Young Men on AIDS (젊은 미혼 남성에서의 에이즈에 대한 지식과 태도)

  • Yeom, Chang-Hwan;Lee, Hye-Ree;Choi, Youn-Seon
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.4-13
    • /
    • 2001
  • Purpose : Since the acquired immune deficiency syndrome (AIDS) was first recognized in the United States in the summer of 1981, the number of these patients has been increasing in the world. But do not find out a cure and a vaccine for ARS (5). And so, the best treatment for AIDS is the prevention. People can find out accurate knowledge about AIDS, and they can prevent themselves from AIDS approximately 100%. In this study, we investigate with AIDS knowledge and attitudes in unmarried young men (<24 age) and suggest accurate preventive education for AIDS and good sexual behaviors. Methods : Un-married young soldiers and college students who were not diagnosed as AIDS until June 30, 2000 were included in the study. The study included a total of 923 men. A self evaluation questionnaire, included questions on 36 items(the part of demographic data - 9; the part of knowledge - 20; the part of attitudes - 8), was drawn up by three physicians. The demographic data, AIDS knowledge and attitudes were analyzed by chi-square analysis, and the total score of AIDS knowledge - comparison according to demographic factors and attitudewere analyzed by one-way ANOVA test. Results : In demographic characteristics, as for the first recognized time of AIDS, most of men knew it when they were in their middle school, as for sources of information on AIDS, most of them knew it through the TV-media, and as for the educational need about AIDS, most of them agreed with it. In AIDS knowledge, mean scores were $14.0{\pm}1.8$ (70.3%). Items of the misconceptions concerning AIDS, reported as less than 50% correct answers, were 6 among 20 items (30%). In AIDS attitudes, as for the item about that if I will be an AIDS patient, I will have an AIDS treatment, it showed that the number of men agreed with 759 (82.2%), and as for the item about that I will help for AIDS patient even though I don't know him, it showed that the number of them agreed with 412 (45.8%). In correlation of AIDS knowledge and demographic factors, the mean scores of knowledge of men with higher than college degree were higher than them of others. The mean scores of knowledge of men with total income of family with more than US$1667 were higher than them of others. The mean scores of knowledge of men with sources of information on AIDS through the TV-media were higher than them of others. And the mean scores of knowledge of men with past medical history of STD(sexually transmitted disease) were higher than them of others. Conclusions : The higher the knowledge he has, the lower the possibility of risk and the more positive the attitude he has. And then we think that the education program for AIDS will be included as a regular part of the curriculum in high school, and young men must be effectively educated by it.

  • PDF

In vivo evaluation of accuracy and consistency of two electronic apex locators (2종 전자근관장측정기의 정확도 및 일관성에 관한 in vivo 연구)

  • Pi, Chien-Yun;Kim, Eui-Seong;Jung, Il-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.6
    • /
    • pp.453-460
    • /
    • 2010
  • Objectives: To evaluate the accuracy and consistency of two different apex locators at both the Apex and 0.5 marks. Materials and Methods: Twenty-six root canals was scheduled for extraction for periodontal or prosthodontic reasons. Thirteen canals were measured using Root ZX and the rest by i-ROOT. The root canal length was measured both the at 0.5 mark and the Apex mark. The file was then fixed to the toot, and the distance from the file tip to the major foramen of each canal was measured after removing the root dentin under the microscope so that the major foramen and the file tip were seen. Results: 1. When the Apex mark was used, 100% of both the Root ZX and i-ROOT groups were within 0.5 mm of the major foramen. 2. When 0.5 mark was used, 100% of the Root ZX group and 77% of the i-ROOT group were within 0.5 mm of the major foramen. 3. In terms of standard deviation and quartile value, the Apex mark was more consistent than 0.5 mark in the Root ZX group, and 0.5 mark was more consistent in the i-ROOT group, but there was no statistically significant difference when compared with t-test. 4. The root canal length difference between the Apex mark and 0.5 mark was 0.22 mm and 0.46 mm in the Root ZX and i-ROOT groups, respectively. Conclusions: In this study, the Apex mark was the more consistent mark. Therefore, it is recommended to subtract 0.5 mm, which is the average length between the apex and apical constriction, from the root canal length at the Apex mark to obtain the working length clinically.

The evaluation of color and color difference according to the layering placement of Incisal shade composites on the body composites of the indirect resin restoration (간접 수복용 복합레진의 Incisal 색상 적층 두께에 따른 표면 색상 및 색차의 평가)

  • Park, Su-Jung;Lee, Han-Young;Nah, Myong-Yun;Chang, Hoon-Sang;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.37-49
    • /
    • 2011
  • Objectives: The aim of this study was to evaluate the surface color of indirect resin restoration according to the layering placement of different shade of incisal composite. Materials and Methods: In this study, CIE $L^*a^*b^*$ value of 16 Body composite of Tescera ATL (Bisco, Schaumburg IL,USA) was measured by spectrophotometer (NF999, Nippon Denshuku, Japan), and compared to CIE $L^*a^*b^*$ value of Vitapan shade guide. Nine shade Incisal composite of Tescera ATL were buildup to 1 mm thickness on Body composites inlay block, and CIE $L^*a^*b^*$ value was measured. Incisal composite was ground to 0.5 mm thickness and CIE $L^*a^*b^*$ value was re-measured. Color difference between Body composite and Incisal composites layered on Body composite was calculated as a function of thickness. Results: Color difference between corresponding shade of Tescera Body composite and Vitapan shade guide was from 6.88 to 12.80. $L^*$ and $b^*$ value was decreased as layering thickness of Incisal composite on Body composite was increased. But, $a^*$ value did not show specific change tendency. Conclusions: Surface color difference between Body composites and Incisal composites layered on Body composite was increased as the layering thickness of Incisal composite increased (p < 0.05).

Development of an accreditation system for dietary and nutrition related education resources (영양.식생활 교육자료의 인증 시스템 개발 연구)

  • Kim, Ji-Myung;Lee, Kyoung Ae;Park, Yoo Kyoung;Lee, Kyung-Hea;Oh, Sang Woo;Lee, Hee Seung
    • Journal of Nutrition and Health
    • /
    • v.47 no.2
    • /
    • pp.145-156
    • /
    • 2014
  • Purpose: The purpose of this study was to establish accreditation systems of reliable educational materials for nutrition and dietary life which could be used in schools, workplace, and health promotion. Methods: The study was conducted from April 2011 to October 2011. Literature reviews, institutional visits, and telephone interviews were conducted. Expert meetings and advisory councils were held in order to receive feedback on development of the accreditation systems. A survey was conducted for the accreditation procedures on 143 professionals, including professors, researchers, health and medical experts, teachers, nutrition teachers, dietitians, and clinical nutritionists. Results: The final procedure of the developed accreditation system was finalized as follows: 1) receiving application twice per year 2) complete desk review (written evaluation) by three reviewers within two months, 3) board review (all board members) and decision, and 4) notification of results. The accreditation system is set for printed materials, web-site, and materials for activities. The certificate and accreditation mark is issued to the final certified educational materials. Expiration date is established only for the web-site form. The accreditation length lasts for two years, and can be extended by renewal application. Conclusion: The dietary and nutrition related materials, which are certificated by this accreditation system, could impart reliable information and knowledge to both learners and educators, and help them in effective selection of educational materials. Therefore, this accreditation system might be expected to increase satisfaction for teaching and learning about nutrition and healthy dietary life.

Analysis of factors affecting customer satisfaction of HACCP applied restaurant in highway service area (HACCP 적용 고속도로 휴게소 식당의 고객 만족도에 영향을 주는 요인 분석)

  • Kim, Tae-Hyeong;Bae, Hyun-Joo
    • Journal of Nutrition and Health
    • /
    • v.50 no.3
    • /
    • pp.294-301
    • /
    • 2017
  • Purpose: The purposes of this study were to investigate food consumption practices and analyze factors that influence customer satisfaction of an HACCP applied restaurant in a highway service area. Methods: A total of 207 customer responses were used for data analysis. Statistical analyses were conducted using the SPSS program (ver. 22.0) for $x^2$-test, Pearson correlation analysis, and multiple regression analysis. Results: Reasons for visiting the highway area were using the restroom (86.0%), purchasing of meals or snacks (70.1%), taking a rest (58.5%), and shopping (3.4%) and selection attributes of food sold in the highway service area were food taste (48.8%), food safety (33.3%), and waiting time for meal (10.7%). According to the results of the survey, udon (66.2%) was the most preferred meal, followed by instant noodles (56.0%), kimbap (50.7%), pork cutlet (38.2%), and bibimbap (29.0%). In addition, coffee (73.4%) was the most preferred among snacks and beverages, followed by beverages (58.9%), walnut cake (53.1%), mineral water (52.2%), and hotbar (52.2%). Satisfaction evaluation scores of foods sold in the highway service area were highest for appropriate portion size, followed by food safety, menu variety, food taste, and reasonable price. Overall customer satisfaction scores regarding the restaurant in the highway service area was 3.24 out of 5 points on average. According to the results of the multiple regressing analysis, food taste (p < 0.001) and reasonable price (p < 0.01) had significant positive effects on overall customer satisfaction. Conclusion: To enhance customer satisfaction, restaurant managers in the highway service area should implement HACCP, improve food taste, and set up a proper price for food sold at the restaurant in the highway service area.