• Title/Summary/Keyword: Evaluation parameter

Search Result 1,648, Processing Time 0.033 seconds

Modified AWSSDR method for frequency-dependent reverberation time estimation (주파수 대역별 잔향시간 추정을 위한 변형된 AWSSDR 방식)

  • Min Sik Kim;Hyung Soon Kim
    • Phonetics and Speech Sciences
    • /
    • v.15 no.4
    • /
    • pp.91-100
    • /
    • 2023
  • Reverberation time (T60) is a typical acoustic parameter that provides information about reverberation. Since the impacts of reverberation vary depending on the frequency bands even in the same space, frequency-dependent (FD) T60, which offers detailed insights into the acoustic environments, can be useful. However, most conventional blind T60 estimation methods, which estimate the T60 from speech signals, focus on fullband T60 estimation, and a few blind FDT60 estimation methods commonly show poor performance in the low-frequency bands. This paper introduces a modified approach based on Attentive pooling based Weighted Sum of Spectral Decay Rates (AWSSDR), previously proposed for blind T60 estimation, by extending its target from fullband T60 to FDT60. The experimental results show that the proposed method outperforms conventional blind FDT60 estimation methods on the acoustic characterization of environments (ACE) challenge evaluation dataset. Notably, it consistently exhibits excellent estimation performance in all frequency bands. This demonstrates that the mechanism of the AWSSDR method is valuable for blind FDT60 estimation because it reflects the FD variations in the impact of reverberation, aggregating information about FDT60 from the speech signal by processing the spectral decay rates associated with the physical properties of reverberation in each frequency band.

A Study on the Drug Classification Using Machine Learning Techniques (머신러닝 기법을 이용한 약물 분류 방법 연구)

  • Anmol Kumar Singh;Ayush Kumar;Adya Singh;Akashika Anshum;Pradeep Kumar Mallick
    • Advanced Industrial SCIence
    • /
    • v.3 no.2
    • /
    • pp.8-16
    • /
    • 2024
  • This paper shows the system of drug classification, the goal of this is to foretell the apt drug for the patients based on their demographic and physiological traits. The dataset consists of various attributes like Age, Sex, BP (Blood Pressure), Cholesterol Level, and Na_to_K (Sodium to Potassium ratio), with the objective to determine the kind of drug being given. The models used in this paper are K-Nearest Neighbors (KNN), Logistic Regression and Random Forest. Further to fine-tune hyper parameters using 5-fold cross-validation, GridSearchCV was used and each model was trained and tested on the dataset. To assess the performance of each model both with and without hyper parameter tuning evaluation metrics like accuracy, confusion matrices, and classification reports were used and the accuracy of the models without GridSearchCV was 0.7, 0.875, 0.975 and with GridSearchCV was 0.75, 1.0, 0.975. According to GridSearchCV Logistic Regression is the most suitable model for drug classification among the three-model used followed by the K-Nearest Neighbors. Also, Na_to_K is an essential feature in predicting the outcome.

Generating Sponsored Blog Texts through Fine-Tuning of Korean LLMs (한국어 언어모델 파인튜닝을 통한 협찬 블로그 텍스트 생성)

  • Bo Kyeong Kim;Jae Yeon Byun;Kyung-Ae Cha
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.29 no.3
    • /
    • pp.1-12
    • /
    • 2024
  • In this paper, we fine-tuned KoAlpaca, a large-scale Korean language model, and implemented a blog text generation system utilizing it. Blogs on social media platforms are widely used as a marketing tool for businesses. We constructed training data of positive reviews through emotion analysis and refinement of collected sponsored blog texts and applied QLoRA for the lightweight training of KoAlpaca. QLoRA is a fine-tuning approach that significantly reduces the memory usage required for training, with experiments in an environment with a parameter size of 12.8B showing up to a 58.8% decrease in memory usage compared to LoRA. To evaluate the generative performance of the fine-tuned model, texts generated from 100 inputs not included in the training data produced on average more than twice the number of words compared to the pre-trained model, with texts of positive sentiment also appearing more than twice as often. In a survey conducted for qualitative evaluation of generative performance, responses indicated that the fine-tuned model's generated outputs were more relevant to the given topics on average 77.5% of the time. This demonstrates that the positive review generation language model for sponsored content in this paper can enhance the efficiency of time management for content creation and ensure consistent marketing effects. However, to reduce the generation of content that deviates from the category of positive reviews due to elements of the pre-trained model, we plan to proceed with fine-tuning using the augmentation of training data.

Evaluation of Standardized Uptake Value applying EQ PET across different PET/CT scanners and reconstruction (PET/CT 장비와 영상 재구성 차이에 따른 EQ PET을 이용한 표준섭취계수의 평가)

  • Yoon, Seok Hwan;Kim, Byung Jin;Moon, Il Sang;Lee, Hong Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Purpose Standardized uptake value(SUV) has been widely used as a quantitative metric of uptake in PET/CT for diagnosis of malignant tumors and evaluation of tumor therapy response. However, the SUV depends on various factor including PET/CT scanner specifications and reconstruction parameter. The purpose of this study is to validate a EQ PET to evaluate SUV across different PET/CT systems. Materials and Methods First, NEMA IEC body phantom data were used to calculate the EQ filter for OSEM3D with PSF and TOF reconstruction from three different PET/CT systems in order to obtain EARL compliant recovery coefficients of each spheres. The Biograph true point 40 PET/CT images were reconstructed with a OSEM3D+PSF reconstruction, images of the Biograph mCT 40 and Biograph mCT 64 PET/CT scanners were reconstructed with a OSEM3D+PSF, OSEM3D+TOF, OSEM3D+PSF+TOF. Post reconstructions, the proprietary EQ filter was applied to the reconstruction data. Recovery coefficient can be estimated by ratio of measured to true activity concentration for spheres of different volume and coefficient variability(CV) value of RC for each sphere was compared. For clinical study, we compared SUVmax applying different reconstruction algorithms in FDG PET images of 61 patients with lung cancer using Biograph mCT 40 PET/CT scanner. Results For the phantom studied, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.05, 0.04, 0.04 and 0.03 respectively for RC. Application of the proprietary EQ filter, the mean values of CV for OSEM3D, OSEM3D+PSF, OSEM3D+TOF and OSEM3D+PSF+TOF reconstructions were 0.04, 0.03, 0.03 and 0.02 respectively for RC. Clinical study, there were no statistical significance of the difference applying EQ PET on SUVmax of 61 patients FDG PET image. (p=1.000) Conclusion This study indicates that CV values of RC in phantom were decreased after applying EQ PET for different PET/CT system and The EQ PET reduced reconstruction dependent variation in SUVs for 61 lung cancer patients, Therefore, EQ PET will be expected to provide accurate quantification when the patient is scanned on different PET/CT system.

Soil Testing for Potassium in Upland Soils -Review on the Methodologies- (밭토양(土壤)에 대(對)한 가리(加里) 검정(檢定))

  • Hong, Chong Woon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.3
    • /
    • pp.153-170
    • /
    • 1977
  • Considering the ways for the possible improvement of soil test for upland crops, various methods for the evaluation of K supplying power and testing of available soil K were reviewed in terms of theoretical principles and practical usefulness of the each method. The review was also made on the characteristics of upland crops in K requirement and on the chemical properties of major korean upland and lowland rice soils in terms of K availability. Following is the few remarks drawn from the review. 1. Quite large number of methods have been known for the evaluation of K supplying power and testing for available soil K. In nature, they can be divided into two categories; capacity-based methods and intensity-based methcds. The capacity-based methods usually measure the exchangeable and some portion of nonexchangeable K, while the intensity-based methods suggest to consider the ractivity ratios of major cations in soil solution and the energy requirement for the replacement of exchangeable soil K into soil solution. 2. As methodology for extraction of interested part of soil K, chemical extraction, electrodialysis and ion exchange methods have been known. Among these, chemical extract ion is favorable because of its simplicity. However, recently suggested Electro-Ultra-Filtration method seems to merit further study for wider use for not only K but also other nutrient availability of soils. 3. The intensity-based methods, although they are more theoretical, because of their complexity, in methods may not be adapted for practical soil tests. 4. The exchangeable K which is rather simple to measure and which well reflects the status of K reserve as nonexchangeable and is immediate pool of water soluble K may be good, if not best, criterion of soil K availability to plant in common soil testing. 5. Because there are evidences that the abundance of available K alone may not be good inclication for availability of K to plant, it is recommendable to interprete the exchangeable K data as percent saturation of exchangeable K to total C. E. C. of soil for the recommend ation of K fertilizer based on soil tests. 6. Some pot and field trial results showed the trends that percent potassium saturation to total C. E. C. better serve as the parameter for K fertilizer recommendation.

  • PDF

Evaluation of Roadmap Image Quality by Parameter Change in Angiography (혈관조영검사에서 매개변수 변화에 따른 Roadmap 영상의 화질평가)

  • Kong, Chang gi;Song, Jong Nam;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • The purpose of this study is to identify factors affecting picture quality in Roadmap images, which were studied by varying the dilution rate, collimation field and flow rate of contrast medium. For a quantitative evaluation of the quality of the picture, a 3mm vessel model Water Phantom was self-produced using acrylic, a roadmap image was acquired with a self-produced vascular model Water Phantom, and the SNR(Signal to Noise Ratio) and CNR (Contrast to Noise Ratio) were analyzed. CM:N/S In the study on the change of dilution rate, CM:N/S dilution rate changed to (100%~10%:100%), and the measurement of the roadmap image taken using the vascular model Water Phantom showed that the measurement value of SNR gradually decreased as the N/S dilution rate was increased, and the measurement of CNR was gradually reduced. It was confirmed that the higher the dilution rate of CM:N/S, the lower the SNR and CNR, and also significant image can be obtained at the dilution rate of CM:N/S (100%~70:30%). The study showed the value of SNR and CNR in Roadmap image was increased as the Collimation Field was narrowed to the center of the vascular phantom; the Collimation Field was narrowed to the center of the vessel model by 2cm intervals to 0cm through 12cm. To verify the relationship with Roadmap image and Flow Rate, volume of the autoinjector was kept constant at 15 and the flow rate was gradually increased 1, 2, 3, 4, 5, 6, 7, 8, 9, 10. The value of SNR and CNR of images taken by using water Phantom gradually decreased as the Flow Rate increased, but at Flow Rate 9 and 10, the SNR and CNR value was increase. It was not possible to confirm the relationship with SNR and CNR by ROI mean value and Background mean value. It is considered that further study is needed to evaluate the correlation about Roadmap image and Flow Rate. In conclusion, as the dilution rate of N/S in contrast medium was increased, the value of SNR and CNR was decreased. The narrower the Collimation Field, the higher image quality by increasing value of SNR and CNR. However, it is not confirmed the relationship Roadmap image and Flow Rate. It is considered that appropriate contrast medium concentration to minimize the effects of kidney and proper Collimation Field to improve contrast of image and reduce exposure X-ray during procedure is needed.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF

A study on the shelf-life extension of fresh-cut onion (Allium cepa L.) (신선편의 양파(Allium cepa L.)의 유통기한 연장연구)

  • Lee, Kyoung-Hae;Kim, Dong-Ho
    • Journal of Food Hygiene and Safety
    • /
    • v.24 no.4
    • /
    • pp.324-331
    • /
    • 2009
  • Peeled whole onions (PWO) were cleaned at various hypochlorous acid (HA) concentration and steeping time and packed in LDPE bag keeping at $10^{\circ}C$ for 12 days and $35^{\circ}C$ for 3 days, in order eventually to examine microbiology, surface color and sensory quality. At the early stage of storage, it was found that total bacterial counts at H-II keeping at $10^{\circ}C$ after 1 minute steeping were $2.60\;{\pm}\;0.18\;log\;CFU/g$, and those after 3 minutes steeping were $2.10\;{\pm}\;0.18\;log\;CFU/g$ which showed less than the control. The total bacterial counts at H-III were detected after 4 days. The total bacterial counts of PWO treated HA increased as steeping time became longer, HA concentration increased, and storage temperature went down. E. coli was not detected at all treatments. It was also found that during the treatment the L-value showed decreasing trend, but the parameter a- and b- value showed increasing trend. But these trends were mitigated as HA concentration increased. The result of sensory quality evaluation for the appearance showed that the sample stored with $10^{\circ}C$ gained higher evaluation than that with $10^{\circ}C$, while the control and H-III gained highest points significantly (p < 0.05) for the sample keeping at $10^{\circ}C$ after 12 days storage. The sensory odor of onion showed similar to that for the appearance, and the 8-day treatments of H-II and H-III showed no significantly difference (p < 0.05). On the basis of the results above, it is likely to be more effective to prolong the period of circulation of PWO if you use HA over 50 ppm for washing PWO and storage at $10^{\circ}C$. This study will contribute to improve safety and quality in circulation of PWO.

Therapeutic Efficacy of Alendronate for Glucocorticoid Induced Metabolic Bone Disease in Children with Nephrotic Syndrome (신증후군 환아에서 스테로이드 유발 대사성 골질환에 대한 Alendronate의 치료 효과)

  • Lee Ji-Eun;Lee Hyun-Ok;Paik Kyung-Hoon;Lee Suk-Hyang;Jin Dong-Kyu
    • Childhood Kidney Diseases
    • /
    • v.8 no.1
    • /
    • pp.33-42
    • /
    • 2004
  • Purpose : Children with nephrotic syndrome(NS) are under high risk for metabolic bone disease(MBD) as a complication of long-term glucocorticoid therapy. We prospectively evaluated the effect of oral bisphosphonate(alendronate) therapy in children with NS, which has proven efficacy in adult patients with glucocorticoid induced MBD. Methods : Among 58 children with NS, aged 5 to 8 years and haying a disease duration of more than 2 years, 30(51.7%) were enrolled to meet the selection criteria, less than -1.0 Z-scores of lumbar spine bone mineral density(BMD) by dual energy X-ray absorptiometry (DEXA). These 30 children were divided into three groups and each were assigned to receive alendronate, calcitriol, and no-medication, respectively for one year. Lumbar spine BMD was followed up every 6 months and the biochemical indexes were measured before and 1 year after the treatment. There were no significant difference among groups with respect to the average age, the initial BMD, and the cumulative steroid doses. Analysis of the treatment efficacy was done by the % change of BMD and by the changes in Z-scores of lumbar spine BMD. Results : Mean age and disease duration of patients at the initial lumbar spine BMD evaluation was $7.4{\pm}1.7$ years and $2.2{\pm}1.2$ years, respectively. Twenty-three of 30 children(76%) had osteopenia, and seven(23%) had osteoporosis. There was no difference in the biochemical values among the groups, before and 1 year after the treatment(P<0.05). Twenty two children(73.3%) with frequent relapsing or steroid dependant NS had more frequent MBD, compared to the 8 children(26.6%) with infrequent relapsing NS. The one year % changes of BMD were 8.56 in alendronate group, 5.79 in calcitriol group, and 1.9 in no-medication group. The changes in Z-score of lumbar spine BMD increased in the alendronate group and the calcitriol group, but not in the no-medication group. One year % changes of BMD were different among groups(P=0.0002). Significant differences were found between the alendronate and the no-medication group, and between the calcitriol and the no-medication group(P<0.05). There was no difference between the alendronate and the calcitriol group. No serious adverse effect was observed in the alendronate group. Conclusion : Children with NS receiving high dose steroids are under the high risk of BMD and should undergo regular BMD evaluation. Z-score of lumbar spine BMD was a useful parameter in diagnosing low bone mass in children. Alendronate weekly oral therapy was effective and relatively safe in increasing the lumbar spine BMD in children with NS having steroid induced MBD.

  • PDF

The Clinical Value of Dual Time Point F-18 FDG PET/CT Imaging for the Differentiation of Colonic Focal Uptake Lesions (장관 내 국소 섭취증가 병소의 감별에 있어 추가 지연 F-18 FDG PET/CT의 임상적 유용성)

  • Kim, Jin-Suk;Lim, Seok-Tae;Jeong, Young-Jin;Kim, Dong-Wook;Jeong, Hwan-Jeong;Sohn, Myung-Hee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.309-316
    • /
    • 2009
  • Purpose: F-18 FDG can be accumulated in the liver, bowel, kidney, urinary tract, and muscles physiologically. The aim of this study was to evaluate the clinical value of dual time point 18F-FDG PET /8 imaging for the differentiation of the colonic focal uptake lesions. Materials and Methods: One hundred thirty two patients (M:F = 77:55, Age 62.8$\pm$11.6 years) underwent $^{18}$F-FDG PET/CT at two time points, prospectively: early image at 50-60 min and delayed image at 4-4.5 hours after the intravenous injection of $^{18}$F-FDG. Focally increased uptake lesions on early images but disappeared or shifted on delayed images defined a physiological uptake. For the differential evaluation of persistent focal uptake lesions on delayed images, colonoscopy and histopathologic examination were performed. SUVmax changes between early and delayed images were also compared. Results: Among the 132 patients, 153 lesions of focal colonic uptake were detected on early images of $^{18}$F-FDG PET/CT. Of these, 72 (47.1%) lesions were able to judge with physiological uptake because the focal increased uptake disappeared from delayed image. Among 81 lesions which was showed persistent increased uptake in delayed image, 61 (75.3%) lesions were confirmed as the malignant tumor and 14 (17.3%) lesions were confirmed as the benign lesions including adenoma and inflammatory disease. Remaining 6 (7.4%) lesions were confirmed as the physiological uptake because there was no particular lesion in the colonoscopy. In the malignant lesions, the calculated dual time point change for SUVmax ($\Delta$%SUVmax) was 20.8$\pm$18.7%, indicating a significant increase in SUVmax between the two point (p<0.01). In contrast, the change in SUVmax for the non-malignant lesions including benign lesions and physiological uptake was -13.7%$\pm$24.2%. For the differentiation of the malignant and non-malignant focal colonic uptake lesions, $\Delta$%SUVmax was the most effective parameter, and the cut-off value using -5% provided the best sensitivity, specificity, and accuracy. Conclusion: The dual time point $^{18}$F-FDG PET/CT imaging with SUVmax change evaluation could be an important noninvasive method for the differentiation of malignant and benign focal colonic uptake lesions including physiologic uptake.