• 제목/요약/키워드: Evaluation Structure

검색결과 5,557건 처리시간 0.029초

Seismic fragility assessment of isolated structures by using stochastic response database

  • Eem, Seung-Hyun;Jung, Hyung-Jo
    • Earthquakes and Structures
    • /
    • 제14권5호
    • /
    • pp.389-398
    • /
    • 2018
  • The seismic isolation system makes a structure isolated from ground motions to protect the structure from seismic events. Seismic isolation techniques have been implemented in full-scale buildings and bridges because of their simplicity, economic effectiveness, inherent stability and reliability. As for the responses of an isolated structure due to seismic events, it is well known that the most uncertain aspects are the seismic loading itself and structural properties. Due to the randomness of earthquakes and uncertainty of structures, seismic response distributions of an isolated structure are needed when evaluating the seismic fragility assessment (or probabilistic seismic safety assessment) of an isolated structure. Seismic response time histories are useful and often essential elements in its design or evaluation stage. Thus, a large number of non-linear dynamic analyses should be performed to evaluate the seismic performance of an isolated structure. However, it is a monumental task to gather the design or evaluation information of the isolated structure from too many seismic analyses, which is impractical. In this paper, a new methodology that can evaluate the seismic fragility assessment of an isolated structure is proposed by using stochastic response database, which is a device that can estimate the seismic response distributions of an isolated structure without any seismic response analyses. The seismic fragility assessment of the isolated nuclear power plant is performed using the proposed methodology. The proposed methodology is able to evaluate the seismic performance of isolated structures effectively and reduce the computational efforts tremendously.

취약도 해석을 위한 철근콘크리트 교각의 지진손상 평가인자 결정 (Development of Seismic Damage Evaluation factor of Reinforced Concrete Pier for Fragility Analysis)

  • 고현무;이지호;강중원;조호현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.308-315
    • /
    • 2002
  • Fragility analysis is widely used for the seismic safety evaluation of a structure. In fragility analysis, damage evaluation is a crucial factor. Most of the present fragility analyses use the representative responses such as displacement and absorbed hysteretic energy as a tool of damage evaluation. But damage evaluation method that can represent the local damage of a structure is required in the case of piers of which the local damage can cause the whole failure of bridge system. Therefore this study proposes a damage index, which can represent the distribution and magnitude of local damage by using the Lee and Fenves'plastic-damage model. Using the proposed damage index, fragility curves and damage probability matrix of pier are produced and fragility analysis is performed.

  • PDF

생활공간에 따른 의복실루엣이미지 평가 (Clothing Silhouette Image Evaluation related to Life Space)

  • 박영실
    • 한국의류산업학회지
    • /
    • 제2권3호
    • /
    • pp.246-252
    • /
    • 2000
  • The purpose of this study was to analyze the characteristics of the factor structure in Clothing Silhouette Image and the differences of Image Evaluation related to Grouping of Line and Grouping of Body Emphasis using Silhouette Image Factor and Life Space as variables. Clothing Silhouette Image was estimated by the photographs of 9 Life Spaces ${\times}$ 23 Clothing Silhouettes with 15 semantic differentiated by-polar scales. The major finding were : The factor structure of Clothing Silhouette Image were found to include 4 factor dimensions-Capability Evaluation, Function, Activity. It was clear that Silhouette Image were affected by Life Spaces. There were the differences of Image Evaluation related to Grouping of Line and Grouping of Body Emphasis. There were the differences of Life Space Evaluation related to Grouping of Line and Grouping of Body Emphasis. Therefore it is important to considerate Life Space for selecting Clothing Silhouette.

  • PDF

초고층 건물에 적용 가능한 건식벽체의 차음성능 평가 (An Evaluation on the Sound Insulation Performance of Drywall for High-Rise Buildings)

  • 이상우;유호천;이수열;정갑철;정영민
    • KIEAE Journal
    • /
    • 제7권2호
    • /
    • pp.3-8
    • /
    • 2007
  • Recently, the structural system of public residential buildings has been changed from the reinforced concrete (RC) wall system to the (PC) wall and moment resisting systems. Thus, it is important to develop the suitable wall system in accordance with the trend of the modern structural system. This paper presents the basic study on the suitable boundary wall in high-rise buildings. The research also demonstrates the evaluation results on sound characteristics in the aspect of sound insulation. The evaluation of sound insulation capability for the commercialized wall structure was conducted based on literature survey while the measurement of sound insulation capability for the light-weght EPP concrete was performed in according to KS F2808 in laboratory. The main objective of this research is to propose the most suitable dry wall system as a sound insulation structure through the comparison and analysis of frequency characteristics and weight-acoustic attenuation.

능력스펙트럼을 이용한 지진격리교량의 내진성능평가 (Seismic performance evaluation using capacity spectrum method of bridge retrofitted with isolators)

  • 김민지;한경봉;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.129-134
    • /
    • 2002
  • The seismic performance evaluation and retrofit process are very important for old bridge. If the result is not appropriate, a retrofit process requires. Among the various retrofit methods, this paper selects a seismic isolator and evaluates a seismic performance of bridge. In case of applied seismic isolators to bridge, it proved that seismic capacity is increased by isolators A period of bridge is increased, and a seismic response is decreased. A method of evaluation is capacity spectrum method. By means of a graphical procedure, capacity spectrum estimates a performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. The objective of this study is to compare a seismic performance of a non-seismic designed bridge and seismic isolated bridge and to verify a effect of seismic isolator

  • PDF

외부조건의 변화에 따른 섬유보강콘크리트의 내구성능 정가에 관한 연구 (A Study on the Evaluation of Durability of Fiber Reinforced Concrete According to the Change of External Conditions)

  • 김남욱
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.97-104
    • /
    • 2008
  • This study was intended to evaluate the permeable performance through a change of reinforcing materials, curing condition, durability evaluation and permeability test, and to select the reinforcing material which could reduce the durability and water tightness from it, as the study for considering how the change of the outside's environment factors that the concrete structure actually contacted with impacted the concrete's durability especially the permeability by referring to such the background of the study. Accordingly, it was judged that evaluating the permeability by considering the severe environment condition where the concrete structure was placed in was more reasonable than measuring the existing permeability coefficient conducted in the sound state for the permeability evaluation of actually-used concrete structure. In this study, it also could be known that the specimen of hybrid fiber reinforced concrete which mixed the long and short steel fiber was the most effective for water tightness enhancement in severe environmental conditions.

기설구조물의 손상도추정 및 내진능력평가 방법에 관한 연구 (Damage Assessment and A seismic Capacity Evaluation of Existing Structures)

  • 윤정방;송종걸;김유진
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.414-421
    • /
    • 1998
  • The content of this paper consists of two related subjects. One is the assessment of damages in the existing structure and the other is the evaluation of seismic capacity of the structure with damage. A method is presented for damage assessment of existing structures using the modal data measured at limited points by the inverse medal perturbation technique. For efficient damage assessment, the number of the unknown probable damaged members is reduced for each damage identification by grouping the members in the large structure. The aseismic capacity is evaluated for the structure using the results of damage assessment. An example analysis is carried out for a building structure subjected to different earthquake excitations.

  • PDF

Inelastic displacement-based design approach of R/C building structures in seismic regions

  • Rubinstein, Marcelo;Moller, Oscar;Giuliano, Alejandro
    • Structural Engineering and Mechanics
    • /
    • 제12권6호
    • /
    • pp.573-594
    • /
    • 2001
  • A two-level displacement-based design procedure is developed. To obtain the displacement demands, elastic spectra for occasional earthquakes and inelastic spectra for rare earthquakes are used. Minimum global stiffness and strength to be supplied to the structure are based on specified maximum permissible drift limits and on the condition that the structure responds within the elastic range for occasional earthquakes. The performance of the structure may be assessed by an inelastic push-over analysis to the required displacement and the evaluation of damage indices. The approach is applied to the design of a five-story reinforced concrete coupled wall structure located in the most hazardous seismic region of Argentina. The inelastic dynamic response of the structure subjected to real and artificially generated acceleration time histories is also analyzed. Finally, advantages and limitations of the proposed procedure from the conceptual point of view and practical application are discussed.

주거.사무공간의 조명환경 평가구조에 관한 연구 (A Study on Evaluation Structure of luminous Environment in o residential space and office work space)

  • 이선영
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.1-9
    • /
    • 2003
  • 본 연구는 공간 특성이 서로 다른 주거공간과 사무공간의 조명환경 평가구조에 어떠한 차이가 있는지를 파악하고, 분위기항목과 행위항목과의 관계를 정립하는데 목적을 두고 먼저 조명환경에 대한 평가항목으로써 20개의 분위기항목과 15개의 행위항목을 선정하였다. 그리고 SD법에 의한 주관평가실험을 실시하였다. 그 결과, 공간의 특성이 달라도 조명환경의 분위기평가는 <활동성>, <안정감>, <고급감>의 3인자로 설명이 가능한 것으로 나타났다. 행위 인자에 있어서는 주거공간의 경우 <작업행위>,<휴식행위>,<오락행위>의 3인자가 추출되었고, 사무공간의 경우 <작업행위>, <비작업행위>의 2인자가 추출되었다. 주거공간에서의 3가지 행위인자를 설명하는데 있어서 가장 커다란 영향을 미치는 분위기인자는 <활동성>인자로 나타났으며, 사무공간의 경우, <작업행위>는 <활동성>인자가, <비작업행위>는 <고급감>인자가 가장 큰 영향을 미치고 있는 것으로 나타났다.

극동 아세아 컨테이너 항만의 능력평가에 관한 연구 (A Study on Evaluating the Ability of the Competitive Container Ports in Far-East Asia)

  • 이석태;이철영
    • 한국항만학회지
    • /
    • 제7권1호
    • /
    • pp.13-24
    • /
    • 1993
  • The rapid progress of the intermodal freight transportation in recent years has induced fierce competition among the adjacent hub ports for container transport. This brings increased attention to the evaluation of the port competitive ability. But it is not easy to evaluate the port competitive ability because this belongs to ill-defined system which is composed of ambiguous interacting attributes. Paying attention to this point, this paper deals the competitive ability of container port in Far-East Asia by fuzzy integral evaluation which is adequate to interacting ambiguous attribute problem. For this, the proposed fuzzy evaluation algorithm is applied to the real problem, based on the factors such as cargo volumes, costs, services, infrastructure and geographical sites These are extracted from the precedent study of port competitive ability, etc. The results show that the port evaluation factors come in following order ; services, costs, infrastructure, geographical sites and cargo volumes. There are some interactions(interaction coefficient, ${\lambda}=-0.664$ between evaluation attributes. The port competitive ability comes in following order : Singapore, Hongkong, Kobe, Kaoshiung and Busan. According to the sensitivity analysis, the rank between Busan and Kaoshiung changes when ${\lambda}=0.7$. From the analysis of the results, we confirmed that the proposed fuzzy evaluation algorithm is very effective in the complex-fuzzy problem which is composed of hierarchical structure with interacting attributes.

  • PDF