• Title/Summary/Keyword: Evaluation Sheet

Search Result 510, Processing Time 0.025 seconds

Useful and Effective Diagnosis and Evaluation Tools for Eenvironmental Change in Increased Mill Water System Closure

  • Linda R. Robertson;Lee, Byung-Tae;Kim, Tae-Joon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.5
    • /
    • pp.1-11
    • /
    • 2001
  • In the past, abundant and clean water was available for paper mills'use. However, the growth of population and industry made water less available nowadays. Also, environmental regulation limits wastewater discharge, which affects mill operation cost. Therefore, paper mills are under pressure to use more recycled water and mill system closure. As a result, chemical and physical parameters of water are changing and new environment if being created for microorganisms in paper mill system as well. The more soluble or suspended organic materials are increased as more water is recycled and less or scarce dissolved oxygen is available, depending on the degree of recycled water usage. Microorganism flora ill paper mill system will be a1so shifted according to the environmental change of mill system. Anaerobic bacteria, including sulfate reducing bacteria (SRB), will be dominant in the system as very low or almost no oxygen available in the system. Nevertheless, it is common in domestic paper mills that employ the same and old biocides as a means of microbial control, and microbiological control is often less recognized or even neglected. The right biocide selection for increased reductive environment of mills is critical for operation and estimated loss from paper quality defects such as sheet break, holes due to microbiological cause is tremendous compared to the microbiological control cost. It is imperative to investigate and diagnosis the environmental change of mills for right control of cumbersome microorganisms. Several useful diagnosis tools, including new technology employing OFM(Optical Fouling Monitor) in situ, are illustrated.

  • PDF

Evaluation of Ultrafiltration Membrane Using Gel Permeation Chromatography (GPC를 이용한 한외여과막의 평가)

  • 정건용;정동진;김천호;신현수;민병렬;김래현
    • Membrane Journal
    • /
    • v.13 no.2
    • /
    • pp.81-87
    • /
    • 2003
  • The permeation experiments f3r the aqueous dextran solutions of which the molecular weights were distributed between several thousands and million daltons were carried out using the dead-end cell system equipped with sheet membrane to determine the molecular weight cut-off (MWCO) of ultrafiltration membranes. The dextran rejections with respect to molecular weight were obtained by GPC analysis of feed and permeate solutions, then the MWCO was decided as the dextran molecular weight corresponding to the 90% rejection. The MWCO of PBTK membrane manufactured by Millipore was varied between 63,000 and 68,000 daltons as the pressure increased from 0.5 to 2.0 bar. However, the MWCO of PBQK(Millipore) and UE 1812(Saehan) under the above operating pressure increased to 3.5 and 4.3 times, respectively. Also, the MWCO of PBTK increased to 25% as the membrane permeation increased from 10 to 40% of the feed solution.

LIDMOD3 Development for Design and Evaluation of Low Impact Development (저영향개발기법 설계 및 평가를 위한 LIDMOD3 개발)

  • Jeon, Ji-Hong;Seo, Seong-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.4
    • /
    • pp.382-390
    • /
    • 2018
  • In this study, the LIDMOD3 was developed to design and evaluate low impact development (LIDMOD). In the same fashion, the LIDMOD3 employs a curve number (NRCS-CN) method to estimate the surface runoff, infiltration and event mean concentration as applicable to pollutant loads which are based on a daily time step. In these terms, the LIDMOD3 can consider a hydrologic soil group for each land use type LID-BMP, and the applied removal efficiency of the surface runoff and pollutant loads by virtue of the stored capacity, which was calculated by analyzing the recorded water balance. As a result of Model development, the LIDMOD3 is based on an Excel spread sheet and consists of 8 sheets of information data, including: General information, Annual precipitation, Land use, Drainage area, LID-BMPs, Cals-cap, Parameters, and the Results. In addition, the LIDMOD3 can estimate the annual hydrology and annual pollutant loads including surface runoff and infiltration, the LID efficiency of the estimated surface runoff for a design rainfall event, and an analysis of the peak flow and time to peak using a unit hydrolograph for pre-development, post-development without LID, and as calculated with LID. As a result of the model application as applied to an apartment, the LIDMOD3 can estimate LID-BMPs considering a well spatical distributed hydroloic soil group as realized on land use and with the LID-BMPs. Essentially, the LIDMOD3 is a screen level and simple model which is easy to use because it is an Excel based model, as are most parameters in the database. This system can be expected to be widely used at the LID site to collect data within various programmable model parameters for the processing of a detail LID model simulation.

Analysis of Complications of Ambulatory General Anesthesia after Discharge in Patients Who are Taking Anticonvulsant (항경련제를 복용하고 있는 지적장애 환자의 외래전신마취 하 치과치료 후 합병증 발생 조사 연구)

  • Cha, Min-Joo;Seo, Kwang-Suk;Kim, Mi-Seon;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.14 no.2
    • /
    • pp.95-100
    • /
    • 2014
  • Background: About 60% of patients with epilepsy showed a variety of complications after returning home. The purpose of this study is to get further information and to help in the anesthetic management of the disable patients with epilepsy. Methods: After searching the outpatient anesthesia list of Seoul National University Dental Hospital clinic of the disabled from September 2010 to March 2012, we found total 83 patient cases who were taking antiepileptic drugs. A nurse of anethesiology department called to the patient's home after general anesthesia and got surveys with questionnaires form filled with complications at home. We enrolled total of 51 patients who agreed to participate this survey. And we also reviewed pre-anesthesia evaluation sheet, anesthesia record, and recovery and discharge record. Results: 11 of 51 (21.6%) patients had seizure convulsion at home within 1 weeks. 33.4% of patients who had at least once seizure attack per week had a seizure attack within 3 days. And 50% of once a month frequency patients had a seizure attack within 1 week. 33% of 1 - 3 seizure attacks per year patient group had a convulsion within 1 week. But there was no seizure attack within 1 week in whom had no seizure attack history during more than 1 year. Conclusions: After dental treatment, patient taking anticonvulsant have so many complications-especially seizure, more than we respected. We need more research about handle these problems.

Evaluation of Building Envelope Performance of a Dry Exterior Insulation System Using Truss Insulation Frame (트러스 단열 프레임을 이용한 건식 외단열 시스템의 외피 종합 성능 평가)

  • Song, Jin-Hee;Lee, Dong-Yun;Shin, Dong-Il;Jun, Hyun-Do;Park, Cheol-Yong;Kim, Sang-Kyun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.6
    • /
    • pp.153-164
    • /
    • 2019
  • The presence of thermal bridges in a building envelope cause additional heat loss which increases the heating energy. Given that a higher building insulation performance is required in these cases, the heat loss via thermal bridges is a high proportion of the total heat energy consumption of a building. For the dry exterior insulation system that uses mullions and transoms to fix insulation and exterior materials such as stone and metal sheet, the occurrence of thermal bridges at mullions and transoms is one of the main reasons for heat loss. In this study, a dry exterior insulation system using the truss insulation frame (TIF) was proposed as an alternative to metal mullions. To evaluate the building envelope performance, structural, air-leakage, water-leakage, fire-resistance, thermal, and condensation risk tests were conducted. In addition, the annual energy consumption associated with heating and cooling was calculated, including the linear thermal transmittance of the thermal bridges. As a result, the dry exterior insulation system using TIF achieved the allowable value for all tests. It was also determined that the annual heating load of a building was reduced by 36.7 % when the TIF dry exterior insulation system was used, relative to the dry exterior insulation system using steel pipes without additional insulations.

A Survey on Students' Perception of Communication Skills in Class of Theories of Korean Medical Famous Physicians (각가의론 수업에서 학습한 의사소통기술에 대한 학생 인식 조사)

  • Jo, Hak-Jun;Jo, Na-Young;Park, Jeong-Su
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.25 no.2
    • /
    • pp.13-31
    • /
    • 2021
  • Objectives : The objectives of this study are to provide the education of communication skills in the class of theories of Korean medical famous physicians and to survey students' perception of the effect. Methods : The class of theories of Korean medical famous physicians was newly designed and was given to students. The results from the questionnaire survey with second year students at department of Korean medicine were applied to the evaluation of study issues. The scale used for this study was the modified version of 'Beyer-Fetzer's Essential Elements of Communication Skills Assessment Sheet', which was developed by researchers in line with the education of Korean medicine. Results : In six (except for 'opening a conversation') out of seven categories, post-test results were more improved than pretest results. In the category of communication skills (a total of 25 questions), post-test results were higher than pretest results in all items. Among them, 13 items were statistically significant. With regard to the question as to how important the class of communication skills is to raise their professionalism as Korean medicine doctor, post-test result was higher than pretest result. Regarding an appropriate education point of time, there were various points in the entire period of curriculum. The appropriateness of teaching-learning method was positively evaluated. In terms of the content helpful for learning, learner-oriented activities was preferred over teacher-oriented lecturing. Conclusions : The communication skills learned in the class of theories of Korean medical famous physicians were effective. Communications skills should be taught constantly in the entire curriculum in order to raise students' professionalism as Korean medicine doctor. In terms of education method, it is desirable to design a class based on students' various activities, rather than lecturing.

Evaluation of measuring accuracy of body position sensor device for posture correction (자세교정을 위한 체위변환 감지 센서 디바이스의 정확성 평가)

  • Choi, Jung-Hyeon;Park, Jun-Ho;Kang, Min-Ho;Seo, Jae-Yong;Kim, Soo-Chan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.3
    • /
    • pp.128-133
    • /
    • 2021
  • Recently Recently, the incidence of spinal diseases due to poor posture among students and office workers is increasing, and various studies have been conducted to help maintain correct posture. In previous studies, a membrane sensor or a pressure sensor was placed on the seat cushion to see the weight bias, or a sensor that restrained the user was attached to measure the position change. In our previous study, we developed a sensor device which can be easily attached to the body with an adhesive gel sheet and that measures and outputs the user's posture and body position in real time, but it has a limitation in the accuracy of the sensor value. In this study, a study was conducted to improve the performance of the position conversion sensor device and quantitatively evaluate the accuracy of the angle conversion measurement value, and a high accuracy with 2.53% of error rate was confirmed. In future research, it is considered that additional research targeting actual users is needed by diversifying posture correction training contents with multimedia elements added.

Evaluation of Failure Mode in Concrete Beam Restrengthened with GFRP with Various Initial Conditions (GFRP로 보강된 다양한 초기 조건의 콘크리트보의 파괴 거동 평가)

  • Jin-Won Nam;Seung-Jun Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.3
    • /
    • pp.177-183
    • /
    • 2023
  • Various failure modes occur in the concrete beams reinforced with GFRP(Glass Fiber Reinforced Plastic) under initial condition and repairing patterns. In this study, the failure behaviors of concrete beams restrengthened with GFRP sheet with slightly higher elastic modulus than concrete were investigated. For the tests, concrete beams with 24 MPa were manufactured, and the effects of initial notch, overlapping, end-strip reinforcement, and fiber anchors were analyzed on failure load. The cases of GFRP overlap around notch and the initial notch showed increasing failure loads similar to those of normal restrengthened case since the epoxy of the saturated GFRP sufficiently repaired the notch area. Compared to the control case without restrengthening of GFRP, the concrete with initial notch showed 0.78 of loading ratio and normal restrengthening showed 4.43~5.61 times of increasing ratio of failure loading, where interface-debonding from flexural crack were mainly observed. The most ideal failure behavior, break of GFRP, was observed when end-strip over 1/3 height from bottom and fiber anchor were installed, which showed increasing failure load over 150 % to normal restrengthening.

Development and Evaluation of Sustainable Housing Teaching-Learning Process Plan for Achieving the Global SDGs by Home Economics in Middle School (중학교 가정교과의 SDGs 교육을 위한 지속가능한 주생활 교수·학습 과정안 개발 및 평가)

  • Kim, Eunkyung;Cho, Jaesoon
    • Journal of Korean Home Economics Education Association
    • /
    • v.32 no.2
    • /
    • pp.77-97
    • /
    • 2020
  • The purpose of this study was to develop and evaluate the sustainable housing teaching-learning process plan aimed to achieve the global SDGs through home economics class in middle school that is based on the ADDIE model. The overall objective of the plan was to contribute to cultivating students' sustainable housing values and to creating sustainable lifestyle through everyday practice. The plan consisting of 4 lessons contained various activity and visual resources(4 individual and 4 team activity sheets, 4 reading texts, 1 homework sheet and 1 evaluation sheet, and 7 videos) for students and (4 sets of ppt and 4 reading texts) for teachers. The theme and team activities of each lesson were related to 2~7 targets of 2~3 SDGs, in total 11 targets of 5 SDGs. The plan was implemented to 4 classes of 127 senior students at Y middle school in Cheongju city during the period from the 29th of August to the 18th of September, 2019. The results showed that students were very positive and highly satisfied with not only practical contents but also adequacy of resources and activities of the whole 4-lessons, so that they actively participated in the lessons more than usual and looked forward to learning more about it. They thoroughly enjoyed various team activities such as brain writing, mandal art, visual thinking, making UCC, and planning the sustainable village as well as writing a short reflective journal at the end of each lesson. Students also reported that they highly accomplished the goal of each lesson and the overall objective. It could be concluded that the teaching-learning process plan of 4-lessons could contribute to cultivating students' sustainable housing values and to creating sustainable lifestyle through practicing everyday life. It indicates that home economics is one of the major subjects to contribute to the attainment of global issue of SDGs for OECD education 2030 and to educate the practically acting global citizen.

Structural Performance Evaluation of Floating PV Power Generation Structure System (수상 부유식 태양광발전 구조물의 구조적 성능 평가)

  • Choi, Jin Woo;Seo, Su Hong;Joo, Hyung Joong;Yoon, Soon Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1353-1362
    • /
    • 2014
  • In recent years, numerous environmental problems associated with the excessive use of fossil fuel are taking place. For an alternative energy resource, the importance of renewable energy and the demands of facilities to generate renewable energy are continuously rising. To satisfy such demands, a large number of photovoltaic energy generation structures are constructed and planned with large scale. However, because these facility zones are mostly constructed on land, some troubles are occurred such as rising of construction cost due to the cost of land use, environmental devastation, etc. To solve such problems, the floating type photovoltaic energy generation system using FRP members have been developed in Korea. FRP members are recently available in civil engineering applications due to many advantages such as high strength, corrosion resistance, light weight, etc. and they are suitable to fabricate the floating structures because of their material properties. In this study, the analytical and experimental investigations to evaluate the structural performance of floating PV generation structure and SMC FRP vertical member which is used to fabricate the structure were conducted. The static and dynamic performances of floating PV generation structure are evaluated through the FE analysis and the experiment, respectively. Moreover, the structural safety evaluation and buckling analysis of SMC FRP vertical compression member are also conducted by the FE analysis, and the structural behavior of SMC FRP member under compression and pullout is investigated by the experiments. From this study, it was found that the structural system composed of pultruded FRP and SMC FRP members are safe enough to resist externally applied loads.