• Title/Summary/Keyword: Evaluating Tool

Search Result 846, Processing Time 0.036 seconds

A Study of Warm-Mix Asphalt's Bonding Properties on the Change of Asphalt Film Thicknesses (아스팔트 피막두께 변화에 따른 중온 아스팔트의 접착성질에 관한 연구)

  • Yoo, In-Sang;Cho, Dong-Woo;Hwang, Sung-Do;Rhee, Suk-Keun
    • International Journal of Highway Engineering
    • /
    • v.13 no.4
    • /
    • pp.29-40
    • /
    • 2011
  • Warm-Mix Asphalt(WMA) technologies have been developed since 15 years ago, which are internationally and domestically concerned with energy-saving and environmental-friendly technologies in public and private sectors of highway engineering. The performance of asphalt mass is traditionally evaluated by the penetration, viscosity, or Superpave tests. This research, however, is focused more on the properties depending on asphalt film thicknesses instead of evaluating asphalt mass behaviors by those tests. For this approach, a new testing protocol and analysis method are described by the bonding properties on each film thickness. This testing method and analysis tool are borrowed from those of DSR Moisture Damage test and applied by using ARES. The analysis results indicate that there is a limit film thickness between $200{\mu}m$ and $400{\mu}m$, which causes significant changes of the properties. In addition, the results show that the property changes of Hot-Mix Asphalt(HMA) and WMA on the limit film thickness are also different. Therefore, it is suggested that the properties on thin film thicknesses between $200{\mu}m$ and $400{\mu}m$ should be considered in order to evaluate WMA properly.

Development of a Method to Analyze Powering Performance of a Ship and its Application to Optimum Hull Form Design (선박(船舶)의 정수중(靜水中) 추진성능(推進性能) 해석(解析) 및 최적선형설계(最適船型設計)에의 응용(應用))

  • Seung-Il,Yang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.22 no.2
    • /
    • pp.35-48
    • /
    • 1985
  • The present work develops a method of evaluating thrust deduction and wake for different loads of the propeller using the concerted application of the theoretical tools and experimental techniques. It also shows the applicability of the new method to the design of optimum hull form. Firstly, the problem of hull-propeller interaction was analyzed in terms of inviscid as well as viscous components of the thrust deduction and wake. The wavemaking resistance of a hull and propeller were mathematically represented by sources on the hull surface and sink on the propeller plane, respectively. The strength of sink was determined by utilizing the radial distributions of propeller load and nominal wake. The resistance increment due to a propeller and the axial perturbation flow induced by the hull in the propeller plane were calculated. Especially, the inviscid component of the thrust deduction was calculated by subtraction the wavemaking resistance of a bare hull, the wavemaking resistance of a free-running propeller and the augmentation of propeller resistance due to hull action from the wavemaking resistance of the hull with a propeller. The viscous components of the thrust deduction and wake were estimated as functions of propeller load which were established by the propeller load varying test after deduction the calculated inviscid components. Secondly, an analysis method of powering performance was developed based on the potential theory and the propeller load varying test. The hybrid method estimates the thrust deduction, wake and propeller open-water efficiency for different propeller load. This method can be utilized in the analysis of powering performance for the propeller load variation such as the added resistance due to hull surface roughness, the added resistance due to wind, etc. Finally, the hybrid method was applied to the optimum design of hull form. A series of afterbody shapes was obtained by systematically varying the waterplane and section shapes of a parent afterbody without changing the principal dimensions, block coefficient and prismatic coefficient. From the comparison of the predicted results such as wavemaking resistance, thrust deduction, wake and delivered power, an optimum hull form was obtained. The delivered power of the optimized hull form was reduced by 5.7% which was confirmed by model tests. Also the predicted delivered power by the hybrid method shows fairly good agreement with the test result. It is therefore considered that the new analysis method of powering performance can be utilized as a practical tool for the design of optimum hull form as for the analysis of powering performance for the propeller load variation in the preliminary design stage.

  • PDF

Evaluation of mesiodistal tooth axis using a CBCT-generated panoramic view (CBCT-재구성 파노라마영상의 근원심 치축에 관한 연구)

  • Song, In-Tae;Cho, Jin-Hyoung;Chae, Jong-Moon;Chang, Na-Young
    • The korean journal of orthodontics
    • /
    • v.41 no.4
    • /
    • pp.255-267
    • /
    • 2011
  • Objective: The purpose of this study was to confirm the reliability of a cone beam computed tomography (CBCT)-generated panoramic view based on a CBCT 3D image and to find the most helpful 2D panoramic image compared with CBCT 3D image when examining the mesiodistal tooth axis. Methods: A test model was constructed according to cephalometric norms. The test model was repeatedly repositioned for CBCT and panoramic radiographic imaging. Panoramic radiographs were acquired at each of the following 3 occlusal plane positions: $-5^{\circ}$, $0^{\circ}$, and $+5^{\circ}$. Measurements of mesiodistal tooth axis in CBCT 3D image, CBCT-generated panoramic view, and panoramic radiographs were compared. Results: Compared with the CBCT-generated panoramic view, CBCT 3D image showed significant difference in the mesiodistal tooth axis in the premolars and no significant difference in the mesiodistal tooth axis in the incisors and canines. Mesiodistal tooth axis on the CBCT-generated panoramic view was significantly different from that on panoramic radiographs. Conclusions: CBCT-generated panoramic view can be a useful tool for evaluating mesiodistal tooth axis.

Design and implementation of an Intelligent Tutoring System for Mobile English Learning (모바일 영어 학습을 위한 지능형 교육 시스템의 설계 및 구현)

  • Lee, Young-Seok;Cho, Jung-Won;Choi, Byung-Uk
    • The KIPS Transactions:PartA
    • /
    • v.10A no.5
    • /
    • pp.539-550
    • /
    • 2003
  • As the service of mobile internet has been expended, student users are increase. The computers have been widely used in a education field as the teaching tool by improvement of the multimedia contents processing and user interface. The English learning using the computers in the restricted education environment provides motivations and effective learning to learners, but still have some problem such as teaching and evaluating without consideration for differences of individual levels. In order to solve the problems and take the advantages, we propose the intelligent tutoring system for english learning with mobile technology. Overcoming limitations of the mobile environment and using proper treacher's roles,. We have applied the conventional estimation method of the intellectual learner level for students. Also, we have proposed the diagnostic function in order to determine the method of teaching-learing and item disposition that each leaner prefers. Then we have designed and implemented the expert module, providing the feedback for teaching, of the intelligent turoring system for mobile english learning. This system will be able to support the interaction between teachers and students and replace some roles of teacher in the mobile english learning.

EVALUATION OF THE EFFECTIVENESS OF THERAPEUTIC SEALING ACCORDING TO THE LESION DEPTHS OF PROXIMAL EARLY CARIES (인접면 초기 우식 병소의 깊이에 따른 therapeutic sealing의 유효성 평가)

  • Lee, Geum-Lang;Ahn, Myung-Ki;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.394-403
    • /
    • 2009
  • As the minimally invasive approach against white spot like early caries lesions in proximal surfaces of the teeth, therapeutic sealing has been introduced and studied for effective materials and methods to arrest the early caries lesion effectively, which is still going on. This study was performed for the purpose of evaluating its validity for the non-cavitated lesions according to the depth from surface using therapeutic sealing followed by artificial caries induction and evaluation with micro-CT, and we obtained the results as follows. 1. It was revealed that the deeper the caries lesions are, the lower radiation intensity at lesion body areas in pre-treatment specimen. 2. In the sealed groups, there were no differences in radiation intensity between pre- and post-treatment, whereas there were significant decreases in unsealed groups(p<0.05). 3. Even in the specimens with the lesions reaching deeply into DEJ, the effect of sealing was significant(p<0.05). Conclusively, it was thought therapeutic sealing can be an effective tool against the early caries lesions, regardless of their depth into tooth, unless cavitated.

  • PDF

Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue (소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가)

  • Choi, Kyunghwa;Kim, Misun;Lee, Koeun;Nam, Okhyung;Lee, Hyo-seol;Choi, Sungchul;Kim, Kwangchul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.17-24
    • /
    • 2020
  • The purpose of this study was to evaluate the accuracy and precision of the three-dimensional (3D) imaging system of children's facial soft tissue by comparing linear measurements. The subjects of the study were 15 children between the ages of 7 and 12. Twenty-three landmarks were pointed on the face of each subject and 16 linear measurements were directly obtained 2 times using an electronic caliper. Two sets of 3D facial images were made by the 3D scanner. The same 16 measurements were obtained on each 3D image. In the accuracy test, the total average difference was 0.9 mm. The precision of 3D photogrammetry was almost equivalent to that of direct measurement. Thus, 3D photogrammetry by the 3D scanner in children had sufficient accuracy and precision to be used in clinical setting. However, the 3D imaging system requires the subject's compliance for exact images. If the clinicians provide specific instructions to children while obtaining 3D images, the 3D device is useful for investigating children's facial growth and development. Also the device can be a valuable tool for evaluating the results of orthodontic and orthopedic treatments.

Correlation between Hair Mercury Concentration and Blood Total Mercury in Several Area Residents (일부 지역 주민들의 모발 수은 농도와 혈중 수은 농도와의 상관성)

  • Kim, Gyeong-Yeon;Seo, Jeong-Wook;Kim, Byoung-Gwon;Kim, Yu-Mi;Kim, Rock-Bum;Kim, Dae-Seon;Kim, Jung-Man;Kim, Choon-Jin;Hong, Young-Seoub
    • Journal of Environmental Health Sciences
    • /
    • v.39 no.2
    • /
    • pp.117-129
    • /
    • 2013
  • Background: This study was carried out for the purpose of comprehensively evaluating the mercury exposure level of residents in several areas and the correlation between hair mercury concentration and blood mercury concentration. Method: One thousand one hundred ninety seven subjects were sampled from 30 sites using random assignment sampling. We performed a questionnaire survey and measured the level of total mercury in hair and blood samples from all subjects. Results: The geometric mean concentrations of hair and blood mercury in all subjects were 1.27 mg/kg [95% confidence interval (CI): 1.23-1.32 mg/kg] and 5.24 ${\mu}g/L$ [95% CI: 5.07-5.41 ${\mu}g/L$], respectively. Male (1.56 mg/kg in hair, 6.00 ${\mu}g/L$ in blood) was significantly higher than that of female (1.03 mg/kg in hair, 4.56 ${\mu}g/L$ in blood), and the concentrations were elevated as age increased up to the 50s. Education, smoking, alcohol drinking, and using of pesticides were also shown to influence mercury concentrations in hair and blood. The ratio of hair/ blood mercury concentration was 261.3. The total mercury concentration in hair was identified to be significantly related with total mercury concentration in blood (r=0.814, p<0.001). Conclusion: The geometric mean concentrations of hair and blood mercury were higher than the levels provided in international recommendations. The total mercury concentration in hair was positively correlated with the concentration in blood. The results of this study suggest that hair mercury be considered as a useful tool for the evaluation of mercury exposure.

Evaluating the Success Factors of Microfinance : A Case Study of Grameen Bank (마이크로파이넨스 성공요인 연구 : 그라민 은행 사례)

  • Nargis, Farhana;Lee, Sang-Ho;Kwon, Kyung-Sup
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.7 no.3
    • /
    • pp.65-73
    • /
    • 2012
  • Microfinance has been an important tool for the economic growth and poverty alleviation. But the success factors and risk factors have not been synthesized in academic literature. This article has paid attention to success factors and potential risk of the Grameen Bank. Grameen Bank methodology is almost the reverse of the conventional banking methodology. Conventional banking is based on the principle that the more you have, the more you can get. Founder of Grameen Bank, Professor Yunus pointed out that, "The least you have the highest you have the priority to receive a loan". On the basis of theoretical literature, there have been different kinds of success factors of microfinance observed in this paper. Key success factors of Grameen Bank are like these: innovation, strict administrative structure, adaptation and learning practice, incentive system. Complementary services such as business consulting and brokerage will contribute to borrowers' economic performance development.

  • PDF

Evaluation of the Accuracy of Distance Measurements on 3D Volume-rendered Image of Human Skull Using Multi-detector CT: Effects of Acquisition Section Thickness and Reconstruction Section Thickness

  • Haijo Jung;Kim, Hee-Joung;Lee, Sang-Ho;Kim, Dong-Wook;Soonil Hong;Kim, Dong-Hyeon;Son, Hye-Kyung;Wonsuk Kang;Kim, Kee-Deog
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.457-460
    • /
    • 2002
  • The image quality of three-dimensional (3D) images has been widely investigated by the qualitative analysis method. A need remains for an objective and quantitative method to assess the image quality of 3D volume-rendered images. The purpose of this study was to evaluate the quantitative accuracy of distance measurements on 3D volume-rendered images of a dry human skull by using multi-detector computed tomography (MDCT). A radiologist measured five times the twenty-one direct measurement line items composed among twelve reference points on the skull surface with a digital vernier caliper. The water filled skull specimen was scanned with a MDCT according to the section thicknesses of 1.25, 2.50, 3.75, and 5.00 mm for helical (high quality; pitch 3:1) scan mode. MDCT data were reconstructed with its acquisition section thickness and with 1.25 mm section thickness for all scans. An observer also measured seven times the corresponding items on 3D volume-rendered images with measuring tools provided by volumetric analysis software. The quantitative accuracy of distance measurements on the 3D volume-rendered images was statistically evaluated (p-value < 0.05) by comparatively analyzing these measurements with the direct distance measurements. The accuracy of distance measurements on the 3D volume-rendered MDCT images acquired with 1.25, 2.50, 3,75 and 5.00 mm section thickness and reconstructed with its section thickness were 48%, 33%, 23%, and 14%, respectively. Meanwhile, there were insignificant statistical differences in accuracy of distance measurements among 3D volume-rendered images reconstructed with 1.25 mm section thickness for the each acquisition section thickness. MDCT images acquired with thick section thickness and reconstructed with thin section thickness in helical scan mode should be effectively used in medical planning of 3D volume-rendered images. The quantitative analysis of distance measurement may be a useful tool for evaluating the quantitative accuracy and the defining optimal parameters of 3D volume-rendered CT images.

  • PDF

Assessment Instruments for Disaster Behavioral Health (재난정신건강 평가도구)

  • Park, Joo Eon;Kang, Suk-Hoon;Won, Sung-Doo;Roh, Daeyoung;Kim, Won-Hyoung
    • Anxiety and mood
    • /
    • v.11 no.2
    • /
    • pp.91-105
    • /
    • 2015
  • Objectives : After disaster, some people develop posttraumatic stress sequelae such as posttraumatic stress disorder (PTSD), major depression, substance use disorders, and suicide. To date, numerous screening and assessment tools for behavioral health issues including mental health problems, psychosocial maladjustment and status of recovery after disaster have been developed. In this condition, one of important topics is to choose instruments that can quickly and accurately measure the issues. Methods : This article reviewed several self-reported scales in adults for disaster behavioral health, which were searched using academic search engines like PubMed, Scopus, KoreaMed and KISS from the earliest available date of indexing through January 31, 2015. Results : More than 40 eligible instruments evaluating the disaster behavioral health issues containing posttraumatic stress sequelae, psychological and social resources, non-disaster stress, and general functions were presented in terms of availability, effectiveness, and expeditiousness. Also, we introduced basic frame aiming on practical usage, which includes standard version and brief version of the instruments for disaster behavioral health. Conclusion : We suggest the accessibility and the applicability of assessment instruments for disaster behavioral health. The systemic review of this article will provide further directions for them.