• Title/Summary/Keyword: Evacuation information

Search Result 320, Processing Time 0.024 seconds

A Study on Fire and Evacuation simulation analysis for use of Disaster Vulnerable Personal Evacuation Device (재난약자 대피 도움장치 활용을 위한 화재 피난 시뮬레이션 분석 연구)

  • Choi, Doo Chan;Hwang, Hyun Soo;Ko, Min Hyeok;Lee, Si Yu
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.824-831
    • /
    • 2020
  • Purpose: In fire case, nursing hospitals are subject to considerable restrictions on evacuation due to the characteristics of occupants and vulnerable elements of buildings, it is important to make evacuation device for vulunerabale person, and need how to intend to increase the efficiency of evacuation by fire and evacuation simulation with helper Method: The smoke characteristics were analyzed by time through fire simulation, finally, the number of helpers according to the day and night was entered, and the evacuation completion time was compared and analyzed using the evacuation simulation. Result: It was found that the evacuation time was shortened by more than 20% when the evacuation assistance device was used for the vulnerable, and the evacuation time was delayed by almost 70% in case of a fire at night compared to the daytime. Conclusion: If the horizontal and vertical evacuation device are effectively utilized in actual fire situations, a strategy appropriate to the situation is deemed necessary. It is expected that evacuation efficiency will increase based on the use of horizontal evacuation evacuation device and vertical evacuation device by developing evacuation manuals

A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena (대규모 실내경기장의 성능위주 방재계획에 관한 연구)

  • Choi, Yong-Seok;Kim, Hyung-Keun;Lee, Kyoo-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

Development of Optimal Evacuation Model using Civil Defense Evacuation Facilities Survey Data (민방위 대피시설 실태 분석을 통한 최적의 대피모형 개발에 관한 연구)

  • Yeo, Wookhyun;Park, Namhee;Kim, Taewhan;Koo, Wonyong
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.1
    • /
    • pp.71-80
    • /
    • 2012
  • It is necessary to establish guidelines when we selecting the civil defense evacuation facilities through quantitative analysis by civil defense evacuation facilities volume. The purpose of this study is to evaluate according to population density and distribution of the capacity of evacuation facilities. The results of this study are as follows. First, it is necessary to consider the capacity of evacuation facilities in order to set up the exact districts of civil defense evacuation facilities. Second, basic data based on to compare the condition of civil defense evacuation facilities is produced by an analysis on evacuation status of the target region. Third, it is proved to consider topographical conditions which do not move the shortest distance. Fourth, in order to create a realistic model, it is necessary to consider the model set various parameters.

Experimental Study on Evacuation Efficiency in the Airplane Cabin on Emergency (항공기 비상상황 시 기내 대피 효율성에 관한 실험적 연구)

  • Jung Hyun Yoo;Young Sam Lee;So Jung Na;Jong Hoon Kim
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.1
    • /
    • pp.128-137
    • /
    • 2024
  • Purpose: This study was conducted to investigate, through experimental methods, the efficiency of passenger movement and evacuation in the event of an emergency situation on an aircraft. Method: The experiment was conducted a total of 4 times, including 3 scenarios. The three situations were evacuation without luggage, evacuation with carry-on baggage, and evacuation with carry-on baggage and carrier. In the experiment, time was measured based on recorded video. Result: The total evacuation time was found to be approximately 1.5 times higher for the evacuation with luggage, and approximately 3.5 times higher for the evacuation with luggage and 3 carriers compared to the evacuation result in a situation where nothing was carried. As a result of applying the evacuation simulation, it was found that there was a difference from the experimental results. In particular, consideration of complex situations such as carrying out and moving carriers is considered to be a situation that requires more technical research. Conclusion: Quantitive data was obtained to determine how carry-on luggage and carrier affect evacuation.

A study on Development of Evacuation Guidance System Using Direction Speaker and Control Lightning (지향성스피커와 조명제어를 이용한 피난유도 시스템 개발에 관한 연구)

  • Jeon, Gaehyun;Kang, Shinwook
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.3
    • /
    • pp.228-234
    • /
    • 2016
  • Recent buildings are complicated and tends to be connected each other and even underground spaces. Although the risk of disaster is increasing, it does not provide training or induction refuge. In this paper, we propose evacuation induction system using directional speaker, for providing persons in danger with useful information on the disaster situation and to evacuate people effectively as an accurate and rapid evacuation guidance.

A Study of the Evacuation Safety for Workers on the Theater Stage Plan Shapes

  • Yong-Gyu, Park;Heung-Sik, Woo
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.3
    • /
    • pp.149-157
    • /
    • 2023
  • The purpose of this study is to suggest that performers in the performing arts actively utilize the loading dock and stage door when evacuating from the stage space of a performance hall in a crisis situation. Therefore, first, we analyzed the system related to the performance hall's safety. The stage evacuation type was classified into A, B, C, and D forms by applying the building law audience evacuation standards. Second, statistical data were organized based on measurement data, and the characteristics of each form were summarized. Third, the network reliability measurement method was borrowed to evaluate the evacuation safety of the evacuation route in the stage space. We confirmed quantitatively that the direction of the loading dock direction and stage door direction on the stage is advantageous for evacuation. In this study, it was possible to distinguish the advantage of evacuation according to the type of evacuation, (A(0.1274)>B(0.1228).>.C(0.0487)) with A being the most advantageous. These results can be expected to improve the evacuation safety of the stage, and furthermore, they are expected to be used as basic data for stage evacuation.

Analysis of the Effect of the Effective width of the Exit of the Evacuation Stairs on the Evacuation Time of the Occupants (피난계단 출입구 유효너비가 수용인원의 피난시간에 미치는 영향 분석)

  • Yang, Sung-Hoon
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.1
    • /
    • pp.73-79
    • /
    • 2022
  • Purpose: The purpose of this study was to investigate the relationship between the minimum effective width (90cm) of the exit of the evacuation stairway installed in accordance with the Building Act and the evacuation time of all occupants using the corresponding floor from an evacuation point of view. Method: The evacuation simulation (Pathfinder) was used to investigate how the change in doorway width affects the evacuation time of occupants. Result: It was found that as the effective width of the doorway became larger than the minimum standard of 90cm, the evacuation time to the evacuation stairs was shortened. This is also proof that the effective width of the evacuation stair entrance can be appropriately applied differently depending on the number of occupants on the floor. Conclusion: In the future, in order to secure evacuation safety of occupants, it is judged that the effective width standard for the exit of the evacuation stairway considering the total number of occupants by use is necessary. In addition, it is expected that the evacuation efficiency of occupants can be greatly increased if various effective width standards for entrances are made according to the number of occupants by use through research and experiments.

Analysis of University Cafeteria Safety Based on Pathfinder Simulation

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.209-217
    • /
    • 2024
  • Recent years have seen a notable increase in fire incidents in university cafeterias, yet the social attention to these occurrences remains limited. Despite quick responses to these incidents preventing loss of life, the need for large-scale evacuation in such high foot traffic areas can cause significant disruptions, economic losses, and panic among students. The potential for stampedes and unpredictable damage during inadequate evacuations underscores the importance of fire safety and evacuation research in these settings. Previous studies have explored evacuation models in various university environments, emphasizing the influence of environmental conditions, personal characteristics, and behavioral patterns on evacuation efficiency. However, research specifically focusing on university cafeterias is scarce. This paper addresses this gap by employing Pathfinder software to analyze fire spread and evacuation safety in a university cafeteria. Pathfinder, an advanced emergency evacuation assessment system, offers realistic 3D simulations, crucial for intuitive and scientific evacuation analysis. The studied cafeteria, encompassing three floors and various functional areas, often exceeds a capacity of 1500 people, primarily students, during peak times. The study includes constructing a model of the cafeteria in Pathfinder and analyzing evacuation scenarios under different fire outbreak conditions on each floor. The paper sets standard safe evacuation criteria (ASET > RSET) and formulates three distinct evacuation scenarios, considering different fire outbreak locations and initial evacuation times on each floor. The simulation results reveal the impact of the fire's location and the evacuation preparation time on the overall evacuation process, highlighting that fires on higher floors or longer evacuation preparation times tend to reduce overall evacuation time.In conclusion, the study emphasizes a multifaceted approach to improve evacuation safety and efficiency in educational settings. Recommendations include expanding staircase widths, optimizing evacuation routes, conducting regular drills, strengthening command during evacuations, and upgrading emergency facilities. The use of information and communication technology for managing emergencies is also suggested. These measures collectively form a comprehensive framework for ensuring safety in educational institutions during fire emergencies.

A Development of Fire Evacuation Simulation System Based 3D Modeling (3차원 공간 기반의 화재피난 시뮬레이션 시스템 개발)

  • Hwang, Yeon-Jung;Koo, Won-Yong;Hwang, Yen-Kyung;Youn, Ho-Ju
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.156-167
    • /
    • 2011
  • The number of buildings is growing at a rapid pace in Korea. It is driven by significant economic improvements, the rapid population growth and urban centralization. Such being this case, some city are underway to building enlargement, Manhattanization. To Solve these problem and ensure the safety of live, fire Evacuation Simulation system is used for safe check of buildings. Forecasting an egress behavior in building fire is so important in order to construct a safe and reliable environment. But, currently most of the fire evacuation simulation system used in practice are foreign software that is not reflect korean conditions. Thus, This study focus on objectives that develop a fire evacuation system considering Korean Characteristics and create 3D space-based topology. so the system calculate evacuation path. This system developed as a result of research can be used by architectural designer in practice due to it is based 3D spatial information modeling.

An Optimal Model for Indoor Pedestrian Evacuation considering the Entire Distribution of Building Pedestrians (건물내 전체 인원분포를 고려한 실내 보행자 최적 대피모형)

  • Kwak, Su-Yeong;Nam, Hyun-Woo;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2012
  • Existing pedestrian and evacuation models generally seek to find locally optimal solutions for the shortest or the least time paths to exits from individual locations considering pedestrian's characteristics (eg. speed, direction, sex, age, weight and size). These models are not designed to produce globally optimal solutions that reduce the total evacuation time of the entire pedestrians in a building when all of them evacuate at the same time. In this study, we suggest a globally optimal model for indoor pedestrian evacuation to minimize the total evacuation time of occupants in a building considering different distributions of them. We used the genetic algorithm, one of meta-heuristic techniques because minimizing the total evacuation time can not be easily solved by polynomial expressions. We found near-optimal evacuation path and time by expressing varying pedestrians distributions using chromosomes and repeatedly filtering solutions. In order to express and experiment our suggested algorithm, we used CA(cellular automata)-based simulator and applied to different indoor distributions and presented the results.