• Title/Summary/Keyword: Evacuation analysis

Search Result 421, Processing Time 0.025 seconds

Characteristics of Thermal and Fluid Flows for Different Fire Locations in Underground Combined Cycle Power Plant (화원 위치에 따른 지하 복합 발전 플랜트 내 열유동 특성 연구)

  • Sung, Kun Hyuk;Bang, Joo Won;Lee, Soyeong;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.716-722
    • /
    • 2017
  • The present study numerically investigates the effect of obstacles located in the trajectory of fire plume flow on heat flow characteristics by using Fire Dynamics Simulation (FDS) software in an underground combined cycle power plant (CCPP). Fire size is taken as 10 MW and two different locations of fire source are selected depending on the presence of an obstacle. As the results, when the obstacle is in the trajectory of fire plume, hot plume arrives at the ceiling about 5 times slower in the upper of the fire in comparison to the results without obstacle. In addition, the average propagation time of ceiling jet increases by about 70 % with the distance from the ceiling in the upper of the fire, and it increases mainly about 4 times at the distance of 10 m. Consequently, it is noted that the analysis of heat flow characteristics in the underground CCPP considering fire scenarios is essential to develop the fire detection system for initial response on evacuation and disaster management.

Prediction of Loss of Life in Downstream due to Dam Break Flood (댐 붕괴 홍수로 인한 하류부 인명피해 예측)

  • Lee, Jae Young;Lee, Jong Seok;Kim, Ki Young
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.879-889
    • /
    • 2014
  • In this study, to estimate loss of life considered flood characteristics using the relationship derived from analysis of historical dam break cases and the factors determining loss of life, the loss of life module applying in LIFESim and loss of life estimation by means of a mortality function were suggested and applicability for domestic dam watershed was examined. The flood characteristics, such as water depth, flow velocity and arrival time were simulated by FLDWAV model and flood risk area were predicted by using inundation depth. Based on this, the effects of warning, evacuation and shelter were considered to estimate the number of people exposed to the flood. In order to estimate fatality rates based on the exposed population, flood hazard zone is assigned to three different zones. Then, total fatality numbers were predicted after determining lethality or mortality function for each zone. In the future, the prediction of loss of life due to dam break floods will quantitatively evaluate flood risk and employ to establish flood mitigation measures at downstream applying probabilistic flood scenarios.

A study on the case analysis of Nitric acid chemical accident and establishment of preventive measures (질산 화학사고 사례분석 및 독성피해 영향범위에 대한 연구)

  • Lee, Hyun-Seung;Shin, Chang-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.488-496
    • /
    • 2020
  • This study was based on nitrate chemical accidents at home and abroad. Toxic gases due to adverse reactions are generated in the workplace, laboratory, hospital, container damage, and chemical misinjection. Through a case review of possible situations and safety, this study analyzed various cases of accidents, accident status, accident type, cause of the accident, location of the accidents, etc. from 2014 to 2018. The plans for improvement in education and nitrate accidents were reviewed. As a result, 36 nitrate chemical accidents were investigated, including 16 careless worker accidents, eight transportation accidents, and 12 facilities shortages. Nitrate chemical accidents are occurring continuously. Based on this, the range of toxic effects using CARIS was calculated at the worst-case scenario, and the effective response range was measured through the damage impact range. For this purpose, the impact range was predicted based on the strengthening of safety education, emergency action plan and correlation, and the quantified data was identified. In addition, the reliability of the scope of impact was reviewed based on the correlation formula that could facilitate the evacuation of residents, and it was applied to actual accident scenarios of the workplace to present the effects of the accident response and preventive measures.

Comparison of Airport Emergency Plans in Korea and Japan and Survey of Emergency Response of Airline Employees at Check-in Counter (한·일 공항비상계획 비교 및 체크인카운터의 항공사 직원 비상대응 실태조사)

  • Kwon, Kyum;Kwon, Byung Hwa;Cheung, ChongSoo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.2
    • /
    • pp.11-25
    • /
    • 2020
  • This study is a basic study to improve responsiveness in the event of a disaster in the landside area of the Airport Passenger Terminal, and it investigated the airport emergency plan and the status of emergency response in the event of a disaster by the airline's ground staff. The Airport Emergency Plan examined the airport evacuation plan of Korea's Gimpo Airport and Japan's Ministry of Land, Infrastructure, and Transport, confirming that the domestic airport emergency plan was not specific. In addition, a survey of 100 airline ground employees working at check-in counters found that 69% of the respondents were unaware of their role in disaster situations, 90% were not educated in emergency response and 98% were not trained in disaster training in landside areas. Cross-analysis confirmed significant results in the safety of the airport where the service life worked and whether it was a role in the event of a disaster. Therefore, it is suggested that the airport emergency response plan should be improved to improve the ability to respond to disaster sites in the landside area of the airport passenger terminal and that the airline's ground staff should be educated and trained to enhance disaster response.

Estimation of Inundation Damages of Urban area Around Haeundae Beach Induced by Super Storm Surge Using Airborne LiDAR Data (항공 LiDAR 자료를 이용한 슈퍼태풍 내습시 해운대 해수욕장 인근 도심지역 침수 피해 규모 추정)

  • Han, Jong-Gyu;Kim, Seong-Pil;Chang, Dong-Ho;Chang, Tae-Soo
    • Spatial Information Research
    • /
    • v.17 no.3
    • /
    • pp.341-350
    • /
    • 2009
  • As the power and scale of typhoons are growing due to global warming and socioeconomic damages induced by super-typhoons are increasing, it is important to estimate inundation damages and to prepare proper adaptation plans against an attack of the super-typhoon. In this paper, we estimated the inundation damages of urban area around Haeundae beach induced by super-typhoons which follow the route of Typhoon Maemi with the conditions of Typhoon Vera (Ise Bay in Japan, 1959), Typhoon Durian (Philippine, 2006) and Hurricane Katrina (New Oleans in U.S.A, 2005). The coastal area around the Haeundae beach (Busan and Gyeongnam province) is expectedly damaged by severe storm surges. In this study we calculated the rise of sea level height after harmonizing the different datum levels of land and ocean and estimated the inundation depth, inundation area and the amount of building damages by using airborne LiDAR data and GIS spatial analysis techniques more accurately and quantitatively. As many researchers are predicting that super-typhoon of overwhelming power will occur around the Korean peninsula in the near future, the results of this study are expected to contribute to producing coastal inundation map and evacuation planning.

  • PDF

Analysis on Disaster Information Effect Process to Occupant Behaviour : Focusing on Relationship to Egress Time (피난시간을 중심으로 본 재실자특성에 대한 재난정보의 작용 과정 분석)

  • Ji, Donghoon;Lee, Seulbi;Lee, Hyun-Soo;Park, Moonseo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.3
    • /
    • pp.11-22
    • /
    • 2018
  • Existing efforts to reduce total egress time actually focused on reducing travel time. However, consideration to reduce perception time or response time was insufficient although the ratio of travel time is one-third of total egress time and situations which the safety cannot be ensured by only reducing travel time were aroused. Therefore, the concept of disaster information, which could reduce both perception time and response time got attention To analyze the effect of disaster information on occupant behaviour, this study identified a relationship between 10 major disaster information and 3 occupant behaviour factors in terms of reducing egress time. By referring the relationship, this study conducted an virtual egress experiment with survey on 4 cases, the elderly, intellectual disabled, hearing disabled and visual disabled, to identify disaster information which reduce total egress time effectively. Finally, by analyzing the experiment result, this study proposed the process of disaster information effect on occupant behaviour as complementing insufficient occupant behaviour to ensure the minimum level of safety and maximizing relatively high occupant behaviour to ensure enough level of safety. The results are expected to account for relationship between disaster information and occupant behaviour with more explanatory power in terms of egress time. With further studies of disaster information and group behaviour, these series of studies could provide basic references for disaster information and occupant behaviour.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Method to Develop Security System through the Analysis on Dangerous Case (위해사례분석을 통한 경호제도의 발전방안)

  • Yu, Hyung-Chang;Kim, Tae-Min
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.161-187
    • /
    • 2008
  • The purpose of this study is to suggest a development method of current Korean security system by analyzing the problems shown in the performance of security work in relation to the terrorism, which is enlarging in the word, from various aspects. In order to perform the study, the researcher considered the basic theory concerned to current Korean law concerned to security, principle and methodology of security, terror and new terrorism. The researcher performed the study by selecting qualitative case study focused on Park Geun-Hye case. Through the study, the methods to develop Korean security system are as follows. First, from the legal aspect, it is necessary to establish the law concerned to terrorism prevention and important person security. Moreover, it is necessary to search for the development of private security by revising Security Industry Act, which is a legal ground of private security. Second, it is necessary to improve and reinforce education & training program, which is not still divided in detail from the aspect of private security cultivation. Moreover, it is necessary to activate personal protection work and enlarge market through Security Industry Act and make an effort to change social recognition over security, which is devaluated in the society. From the viewpoint, national license about private security shall be adopted. The department of president security, which is a representative of official security, shall transfer the advanced technology to private security organization. Third, from the aspect of operation, the operation of security based on SCE principle, human shield principle, the nearest person's protection principle, body extension principle, linear protection principle and evacuation priority principle is required. Therefore, the priority shall be given to preventive security and thorough security plan shall be made for the operation.

  • PDF

A Study on Improvement Way of Fire Simulation Modelling Field through Analysis of Performance-Based Design Reports of High-rise Residential Complex Building in B Metropolitan City (B도시지역 고층 주상복합건축물 성능위주설계도서 분석을 통한 화재 시뮬레이션 분야 개선방안에 관한 연구)

  • Seo, Min-Ji;Lee, Yang-Ju;An, Sung-Ho;Hwang, Cheol-Hong;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.80-85
    • /
    • 2017
  • Recently, in Korea, construction of high-rise buildings has been rapidly increasing. Therefore, in order to minimize the loss of life and property in the event of a fire, "performance-based design" which requires performance equal to or better than current regulations is obligatorily required. However, in the field of fire and evacuation simulation, which occupies a large part in the performance-based design, detailed technical guidelines have not yet been established. Therefore, various designers are proceeding with the computer simulation modelling by referring to the design report book previously performed. Especially, in the case of the fire simulation, according to the judgment of a designer the scenario type is selected and the input values is set. Even if the building is used for the same purpose, it is true that the result can be different depending on how and who designed it. Therefore, in this paper, we have investigated the fire scenarios type and scenarios input values by randomly examining 7 preliminary reports of performance-based design in B metropolitan city. We also propose the improvement strategy for fire simulation and lay the groundwork for establishment of technical guidelines for fire simulation for performance-based design.

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.