• 제목/요약/키워드: Evacuation Plan

검색결과 163건 처리시간 0.033초

지진해일 예경보에 따른 범람도의 실용적 작성 (Practical Construction of Tsunami Inundation Map Corresponding to Disaster Forecast/Warning Systems)

  • 전영준;최준우;윤성범
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.775-778
    • /
    • 2008
  • In general, forecast tsunami heights announced for tsunami warning are computed by using a linear tsunami model with coarse grids which leads the underestimation of inundation area. Thus, an accurate tsunami inundation map corresponding to the forecast tsunami height is indispensible for an emergency evacuation plan. A practical way to construct a relatively accurate tsunami inundation map was proposed in this study for the quantitative forecast of inundation area. This procedure can be introduced as in the followings: The fault dislocations of potential tsunami sources generating a specific tsunami height near an interested area are found by using a linear tsunami model. Based on these fault dislocations, maximum inundation envelops of the interested area are computed and illustrated by using nonlinear inundation numerical model. In this study, the tsunami inundation map for Imwon area was constructed according to 11 potential tsunami sources, and the validity of this process was examined.

  • PDF

대심도 지하역사에서의 화재현상 연구 (The Study on Fire Phenomena in The Deeply Underground Subway Station)

  • 장용준;김학범;이창현;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1773-1780
    • /
    • 2008
  • 대심도 역사에서의 화재 발생시 승객의 주 대피이동로인 계단이 매우 길기 때문에 피난의 어려움이 예상된다. 이에 본 연구에서는 서울 지하철 호선별 대심도 역사 중에서 하나인 숭실대역(7호선, 47m)을 선정하여, 화재시뮬레이션을 수행하였고, 이를 통하여 열기류 및 연기의 거동을 분석하였고, 적절한 피난대책을 고찰하였다. 최근에 지하역사에서의 화재유동 시뮬레이션이 몇 몇 기관에서 수행되고 있으나, 지하의 전역사에서 화재 유동 해석은 드물게 수행되어 왔다. 특히 지하 40m가 넘는 대심도 역사에서의 유동해석은 일반 PC로는 불가능하기 때문에 이에 대한 연구가 전무하였으나, 본 연구에서는 리눅스 클러스터(Linux cluster) 장비를 이용한 병렬처리기법을 적용하여 대심도 역사에서의 화재해석을 수행하였다. 화재유동해석은 화재전용 FDS code를 이용하였으며, 난류모델은 LES 기법을 적용하였다. 화원의 규모는 10MW이고, 성장모델은 Ultrafast model를 적용하였다. 적정한 격자크기는 화원의 특성직경을 통하여 산출하였다. 본 연구에 사용된 총 격자규모는 약 10,000,000개이다. 이는 일반 PC에서는 다루기가 불가능한 격자수이므로, 병렬처리기법을 적용하여 6 cpu 리눅스 클러스터 장비로 수치해석을 수행하였다.

  • PDF

중복도형 인텔리전트빌딩 화재시 연기제어를 통한 피난안전성 확보에 관한 연구 (A Study on Securing Safety of Evacuation through Smoke Control in Case of Fire at the Central Corridor Type Intelligent Buildings)

  • 민세홍;이재문;배연준
    • 대한안전경영과학회지
    • /
    • 제17권2호
    • /
    • pp.117-127
    • /
    • 2015
  • This study investigated the smoke blocking and control systems for the safety of residents evacuation and for the prevention of smoke spread through the central corridor in the event of central corridor type of intelligent building fire. We offered additional ways of utilizing smoke ventilators and intake ventilation equipment and utilized CFD-based fire simulation program(FDS Ver.5.5.3) in order to analyze the effect. As a result, many differences in the smoke block effect, depending on the application of smoke ventilator and location of installation, was found. In addition, the result was found that larger effect was showed not in the case of application of smoke ventilator in central corridor only but application in fire room. The reason is that the smoke leakage is blocked primarily as air is flowed in the fire room through open door by operation of intake smoke ventilator in the public corridor and secondarily, the smoke leakage to the public corridor could be blocked as fire and smoke were released to the opened smoke ventilator continuously. Especially, the effect was maximized through complex interactions by applying smoke ventilator and intake ventilation equipment in corridor together rather than applying smoke ventilator and intake ventilation equipment independently. The proposed measure through this study shall be considered from architectural plan as one of ways for blocking from smoke spread to the central corridor in the central corridor type of intelligent building. In addition, flaws on regulation shall be established and supplemented.

다중이용시설의 화재 시 피난절차 최적화 방안 연구 - 멀티플렉스를 중심으로 - (A Study on the Optimization Method for Evacuation Procedure on Fire in Public Facilities - Focusing on Multiplex -)

  • 신영민;임유리;안용한
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.113-120
    • /
    • 2019
  • 점차 삶의 수준이 향상됨에 따라 건강하고 여유로운 삶에 대한 니즈가 증가하고 있다. 문화에 대한 대중의 니즈를 반영하여 국내에는 여러 개의 상영관으로 구성된 멀티플렉스가 빠른 속도로 보급되고 있다. 그러나 화재발생 시 피난안전 측면에 있어 위험성을 내포하고 있다. 건물의 공간 형태에 익숙하지 않은 불특정 다수의 관객은 피난으로 인한 입장 및 퇴장 동선의 충돌로 혼잡을 겪게 되기 때문이다. 따라서 본 연구에서는 이러한 문제점을 해결하기 위하여 피난시간을 단축할 수 있는 방안을 마련하고자, 상영관별 단계적 피난을 적용하여 피난시뮬레이션을 실시하였다. 해석 결과, 전 상영관이 동시 피난하는 것보다 상영관별로 단계적인 피난하는 것이 피난시간 확보에 유리한 것으로 나타났다.

계절 특성을 고려한 독성 피해예측에 따른 위기대응 고도화에 관한 연구 (A Study on the Advancement of the Contingency Plan upon Prediction of Toxicity Damage Considering Seasonal Characteristics)

  • 황만욱;황용우;이익모;민달기
    • 한국방재안전학회논문집
    • /
    • 제9권2호
    • /
    • pp.23-32
    • /
    • 2016
  • 오늘날 주민 생활공간과 인접해 있는 산업단지의 노후화 문제는 지역사회 안전을 위협하는 원인으로 지적되고 있다. 본 연구에서는 현행의 위험도 분석 및 지역사회 고지범위를 제고하기 위해 대안의 사고시나리오의 영향범위와 계절별 기상 최빈값을 활용하여 모사된 영향범위를 비교 분석하였고, 시간대별로 관측된 풍향을 계절별로 검토하여 독성물질 누출 시 피해 가능성이 높은 지역을 예측하였다. 또한 인명피해를 최소화하기 위한 한계 대피시간 및 최소 이격거리를 제시하였으며, 비상대응에 활용되고 있는 위해관리계획서를 고찰하여 인근 근로자 및 주민에 대해 한층 더 합리적인 안전대책이 이루어질 수 있도록 제언하였다.

LH공사 발코니확장형아파트 단위세대 평면계획경향에 관한 연구 (A Study on Tendency of Extended Balcony Unit Plans of LH Corp)

  • 서붕교;최정오
    • 한국실내디자인학회논문집
    • /
    • 제20권1호
    • /
    • pp.146-153
    • /
    • 2011
  • The purpose of this study was to analyze the type of extended-balcony floor plan which has been reflected as a various forms after making amendment to the apartment extended-balcony legislation on December 2005 and to understand the design tendency of housing unit plan and the characteristic of living space planning by the type of size(pyeong) and extension. The objects of analysis and the plans are 333 example(235 of $84m^2$, 98 of $59m^2$) from the LH corporation competition. The design tendency of balcony space after extension is as follows; First, a type of extension for simple area to increase the area of room adjacent to balcony through balcony extension. Second, a type of functional reinforcement for private room to separate the mixed function followed by strengthening the individual function of the private room. Third, a type of ${\alpha}$-room to play new functions as hobby room, study room, soho-type room with working from home by extending balcony. Fourth, a integrated type to increase flexible efficiency of bed room, living room and kitchen by integrating extended-balcony from the flexible plan. Along with the evaluation of living style through user's environment-behavior research and the counterplan for evacuation space, indoor thermal environment and space for fulfilling the original function of balcony should be proposed in the future study.

2차원 침수해석과 BIM 기술을 활용한 홍수재난 대피지도 작성 (Development of a Flood Disaster Evacuation Map Using Two-dimensional Flood Analysis and BIM Technology)

  • 정창삼
    • 한국방재안전학회논문집
    • /
    • 제13권2호
    • /
    • pp.53-63
    • /
    • 2020
  • 본 연구에서는 2차원 흐름 해석 모형인 Hydro_AS-2D 모형을 이용하여 해수면 상승과 극한 홍수 발생 시 창원시 성산구 및 의창구 일대의 침수피해 상황을 모의하고, 그 결과를 3차원 지형 상에 표출한 후 BIM 기술을 이용하여 최적 대피경로를 도출하였다. 기후변화는 홍수재해 측면에서 크게 두 가지 요소에 영향을 미치는데 해수면 상승과 극한 강우사상의 증가이다. 해수면 상승은 그 자체만으로 연안지역에 해수가 범람하여 침수현상을 유발하는 영향을 미칠 수 있을 뿐 아니라 하천의 기점 홍수위를 상승시켜 하천 전체에 걸쳐 홍수위 상승을 유발한다. 본 연구에서는 기후변화에 의한 해수위 상승과 태풍에 의한 폭풍해일에 의한 해수위 상승, 그리고 태풍에 의한 극한 강우사상을 모의조건으로 설정하였다. 창원시의 지형공간정보와 하천정비기본계획의 하천횡단 정보를 이용하여 유역전체의 3차원 공간정보로 구성하고 이를 수치모형화 하였다. 연구대상지역은 BIM 기술을 이용하여 3차원 지형정보 상에 건물의 층고, 대피소 위치 등의 정보를 가지고 있는 3차원 도시정보모델로 구축하였으며, 수치모의 결과를 이 모델 상에 표출하고 대피계획을 위한 분석에 사용하였다. 침수발생 시 대피경로는 시간에 따른 침수 범위의 변화에 따라 대피소로의 경로를 설정하는 알고리즘에 의해 결정되며, 설정된 경로는 직관적인 3차원 공간정보 상에 표출되어 사용자에게 제공된다.

화재위험도 평가 Tool에 의한 물류창고 공사장 적용성 검증에 관한 연구 (Study on Verification of Applicability for a Warehouse Construction Site using a Fire Risk Assessment Tool)

  • 서용구;민세홍
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.673-688
    • /
    • 2023
  • 연구목적: 공사 중에 발생하는 화재는 빈도는 적으나 그 피해가 크다. 최근 물류유통산업의 성장으로 신축하는 물류창고의 공사장이 증가하고 있어 연구대상으로 선정하고 화재예방을 정량적으로 접근하기 위해 화재위험도 평가 Tool의 개발을 통해 공사현장의 재난을 줄이고자 연구를 진행하였다. 연구방법: 공정에서 진행되는 작업을 분류하여 연소의 3요소에서 제어가 어려운 공기(산소)를 제외한 가연물과 점화원을 등급별로 구분하고, 피난안전성을 추가로 대입하여 종합적인 화재위험평가 Tool을 객관적으로 정량화하여 정립하였다. 연구결과: 개발하여 제시한 화재위험도 평가 Tool을 이용하여 화재위험도가 낮은 굴착공사와, 화재위험도가 중간정도인 설비공사, 화재위험도가 높은 마감공사를 샘플링하여 결과값(CGI)을 도출하였다. 결론: 본 연구에서는 건설현장에서 화재발생 위험도를 평가할 수 있는 Tool의 개발로 위험도 평가에 따른 물적조건(가연물)과 에너지조건(점화원)을 제어하여 구체적인 예방대책의 수립과 피난안전성의 평가를 가능하게 하였다. 향후 건설현장의 화재위험도 평가Tool의 적용을 통해 위험을 줄일 수 있는 공정의 계획 수립과 소방설비의 적응성을 평가하는 기준으로 제공되길 기대한다.

화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로 (A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility)

  • 김봉준;류구환
    • 디지털융복합연구
    • /
    • 제18권9호
    • /
    • pp.191-198
    • /
    • 2020
  • 본 연구에서는 화재대응능력 향상을 위한 화재모의훈련의 개선방안을 제안하기 위해 3개의 업무시설물을 대상으로 화재모의훈련을 실시하고 훈련 교보재의 활용 여부와 대응단계별 대응시간의 훈련평가 반영 여부에 따라 변화하는 훈련 참여자들의 대응자세 및 대응능력을 관찰 및 분석하였다. 분석결과 대다수의 훈련 참가자들은 훈련 교보재 활용과 대응단계별 대응시간이 훈련평가에 반영될 때 훈련 참여도, 대응자세 및 대응능력이 향상되는 것으로 분석되었다. 화재모의훈련을 실시할 경우 훈련 참여자들의 화재대응능력(화재통보 및 화재신고, 초기소화, 대피) 향상과 유지를 위해 화재발생 상황을 유사하게 구현할 수 있는 훈련 교보재를 다수 활용하고 각 대응단계별 목표시간을 설정한 후 이를 기반으로 정량적인 훈련평가를 하여야만 화재대응능력 향상과 향후 화재모의훈련의 개선 및 피드백에 유용한 지표로 활용될 수 있다는 결과를 도출하였다.

화학사고 발생에 따른 주민대피 의사결정 지원을 위한 과학조사장비 활용방안 연구 (A Study on the Use of Scientific Investigation Equipment to Support Decision-making of the Resident Evacuation in the Event of a Chemical Accident)

  • 오주연;이태욱;조국
    • 대한원격탐사학회지
    • /
    • 제38권6_3호
    • /
    • pp.1817-1826
    • /
    • 2022
  • 2012년 구미 불화수소 누출사고 이후 정부는 화학사고의 대응과 수습 등 재난관리를 체계화하고 있다. 특히, 행정안전부는 재난 및 안전관리 기본법을 근거로 화학사고 발생에 따른 주민대피에 대한 명령을 소관하고 있으므로 본 연구에서는 국립재난안전연구원의 화학사고 조사장비를 활용한 화학사고 이후 주민대피 의사결정 지원 및 활용방안을 제시하였다. 화학사고로 인한 과학적 정보수집을 위한 장비 운용체계는 상시와 비상시로 구분하여 원거리 측정장비와 근거리 측정장비의 역할 및 활용목적을 중심으로 제시하였다. 원·근거리 측정장비를 통해 취득된 데이터를 활용하여 비상시에는 화학물질의 검출여부를 모니터링하고, 상시에는 업체별 검출물질에 대한 데이터를 관리함으로써 주민대피 의사결정을 위한 기초자료로 활용할 수 있다. 상시 운용체계에 한하여 장비별로 현장 활용성을 검증하기 위해 화학물질을 측정한 결과, 원거리 측정장비에서는 화학물질의 실시간 검출이 가능함을 확인하였으며, 추후 장비의 측정가능 거리 및 범위에 대한 확인이 필요하다는 점을 확인할 수 있었다. 근거리 측정장비의 경우, 탄화수소 계열의 물질이 주로 검출되며, 온산국가산업단지에 비해 울산·미포국가산업단지에서 높은 수준으로 측정된 것을 확인하였다. 향후 지속적인 데이터 구축을 통해 화학사고 발생에 따른 의사결정 지원을 위한 기초자료로 활용될 수 있을 것으로 기대된다.