Browse > Article
http://dx.doi.org/10.7731/KIFSE.2019.33.1.113

A Study on the Optimization Method for Evacuation Procedure on Fire in Public Facilities - Focusing on Multiplex -  

Shin, Young-Min (Department of Architectural Engineering, Hanyang University)
Lim, You-Ri (National Fire Research Laboratory, National Fire Service Academy)
Ahn, Yong-Han (Department of Architectural Engineering, Hanyang University)
Publication Information
Fire Science and Engineering / v.33, no.1, 2019 , pp. 113-120 More about this Journal
Abstract
The disaster and safety R&D budget has continued to increase since 2008, but the fire safety R&D budget is a small part. Therefore, successful outcomes that could lead to the economic growth of the fire safety industry have not been achieved. This paper suggests a fire safety R&D budget expansion, reinforcement of R&D capacity, and performance growing plan by analyzing the factors that affect the performance of a fire safety R&D project. Empirical analysis was performed through one-way ANOVA and regression analysis using the statistical program, SPSS statistics 21.0. As a result, this study suggests that the continuous expansion of R&D funds and the securing of excellent trained research manpower will be necessary to obtain qualitatively superior patents and papers.
Keywords
Public facilities; Multiplex; Phased evacuation; Fire;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 J. H. Kim, "A Study on Space Composition of Cultureplex Cinema Lobby Space; With focus on Seoul Metropolitan City", Master's Thesis, Hongik University (2018).
2 E. H. An, "A Study on Egress Routes Design Depending on Human Evacuation Behavior in Multi-Plex Theater", Journal of the Architectural Institute of Korea : Planning & Design, Vol. 21, No. 10, pp. 131-138 (2005).
3 KOFIC, "2009 Film Industry Settlement of Accounts", pp. 20-24 (2010).
4 KOFIC, "2017 Film Industry Settlement of Accounts", pp. 53-59 (2018).
5 J. U. Hong, "Multiplex Movie Theater Inspection, 57% 'There is a Problem'", The Joongang Daily (2014).
6 F. Ozel, "Time Pressure and Stress as a Factor During Emergency Egress", Safety Science, pp. 95-107 (2001).
7 K. W. Park and K. H. Lee, "A Study on the Human Evacuation Behavior by Analyzing Crowding Areas in Multi-Plex Theater Fire", Journal of the Architectural Institute of Korea : Planning & Design, Vol. 21, No. 1, pp. 97-104 (2005).
8 NFPA, "Guidelines to Developing Emergency Action Plans for All-Hazard Emergencies in High-Rise Office Buildings", (2014).
9 J. H. Cho and Y. G. Jeong, "A Study of Optimum Evacuation Procedure for High-rise Buildings in Firing", Proceedings of 2016 Autumn Annual Conference, The Architectural Institute of Korea, Vol. 36, No. 2, pp. 692-693 (2016).
10 Y. R. Lim and Y. H. Ahn, "A Study on Comparative Analysis about Evacuation Results According to Advance Information in Underground Subway Fire", Journal of the Korean Society of Hazard Mitigation, Vol. 18, No. 2, p. 224 (2018).
11 S. W. Cho, Y. H. Lee, C. H. Choi and S. G. Oh "A Study on Comparison to International Building Egress Safety Rule in High Rised Dormitory", Journal of the Architectural Institute of Korea : Planning & Design, Vol. 25, No. 2, pp. 67-76 (2009).
12 NFPA 101, "Life Safety Code", pp. 101-92 (2009).
13 H. M. Ko, "A Study on Service Quality and Customer Satisfaction in Multiplex", Master's Thesis, Dankook University (2003).
14 A. KOSMOPOULOS and S. Katsoulis, "An Innovative Evacuation System for Multiplex Cinemas", Pedestrian and Evacuation Dynamics 2012, pp. 135-141 (2013).
15 K Songsakulchai, S Patvichaichod and P Visuwan, "The Study of Evacuation Times from the Multiplex Theatres", American Journal of Applied Sciences, Vol. 9, No. 3, pp. 321-325 (2012).   DOI
16 P. R. Chung, "A Study on the Regulation Plan of Evacuation Facilities Based on the Consciousness of Cinema User", Journal of the Korean Association for Spatial Structures, Vol. 11, No. 3, pp. 105-113 (2011).   DOI
17 J. H. Kim, S. Y. Joo and J. J. Lee, "An Evaluation on Evacuation Safety in Multiplex Cinema based on Fire & Evacuation Simulation", Journal of Korean Institute of Architectural Sustainable Environment and Building Systems, Vol. 1, No. 1, pp. 7-13 (2007).
18 J. S. Park, M. O. Yoon and Y. J. Lee, "A Study on the Comparison of Building Egress Safety Rule in Countries", Transaction of Korean Institute of Fire Science & Engineering, Vol. 16, No. 2, pp. 27-32 (2002).
19 W. K. Kim and D. H. Seo, "A Study on Egress Algorithm for High-rise Building Using Egress Simulation", Fire Science and Engineering, Vol. 32, No. 1, pp. 33-39 (2018).   DOI
20 S. H. Joung and M. O. Yoon, "Vertical Evacuation Speed in Stairwell of a High-rise Office Building", Fire Science and Engineering, Vol. 29, No. 3, pp. 13-20 (2015).   DOI
21 The Building Center of Japan, "Building Disaster Prevention Planning Guidelines" (1997).
22 Ministry of Land, Infrastructure and Transport, "Regulations on Standards for Evacuation and Fire Protection of Buildings" (2018).
23 G. H. Lee, "Building Prevention Planning Theory", Kungnam University Press (2002).
24 S. N. Baek, J. H. Choi, W. H. Hong and J. J. Jung, "A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers", Fire Science and Engineering, Vol. 30, No. 3, pp. 73-78 (2016).   DOI