• Title/Summary/Keyword: European standard method

Search Result 98, Processing Time 0.026 seconds

Establishment of an Analytical Method for Azorubine, an Undesignated Food Colorant in Korea

  • Kim, Min-ji;Park, Ju-hee;Suh, Hee-Jae;Lee, Chan
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.311-318
    • /
    • 2016
  • Azorubine is a synthetic tar color containing azo-bond in the molecular structure. This food colorant has been allowed to be used for beverages, cheese and dried fruits in the European Union and for some food in Australia. Even though it is applicable as a food color in many countries, this compound has not been permitted in Korea so far as a food additive. Thus, this study was performed to establish an analysis method for azorubine in Korea by comparison of three HPLC analysis methods for azorubine and other azo-compounds which are officially used in the European Food Safety Authority (EFSA, EU), the Food Standard Agency (FSA, England) and the National Institute of Food and Drug Safety Evaluation (NIFDS, Korea). The analysis method of the FSA for azorubine showed the best linearity ($r^2=0.999$), limit of detection (LOD, $0.07{\mu}g/mL$), limit of quantification (LOQ, $0.20{\mu}g/mL$), precision (0~0.5%) and accuracy (98.6~100.7%) among tested HPLC methods using a C-18 column and diode array detector (DAD) with ammonium acetate solution and acetonitrile as an eluent solution. Finally selected method of FSA was further verified by inter-day and intra-day experiments with linearity, LOD, LOQ, precision and accuracy. Recovery test showed the recover ratios of 97~103%, 95~101%, and 93~102% in beverages, breads/snacks and other foods, respectively. Inter-laboratory test represented the absolute value of z-score of less than 2 which means satisfactory levels in this test. Selected method of FSA showed reliable analytical results in application test using food samples collected in commercial markets in Europe.

Inward Leakage Test for Particulate Filtering Respirators in Korea (방진마스크의 안면부 누설률에 관한 연구)

  • Han Don-Hee
    • Journal of Environmental Health Sciences
    • /
    • v.30 no.5 s.81
    • /
    • pp.432-439
    • /
    • 2004
  • Korean certification regulation for particulate filtering respirators requires inward leakage (IL) test as European Standards (EN) and the standard levels of regulation are the same as those of EN. This study was conducted to evaluate particulate filtering respirators being commercially used in the market by using IL and assess the characteristics of IL. The study began with discussing the concept of IL, comparison of IL with fit test, and IL measurement method. Three brands of half masks and 10 brands of filtering facepieces (two top class, four 1st class and four 2nd class), total 13 brands respirators, and 10 test panels (subjects) who were classified in 9 facial grids in accordance with face length and lip length, were selected for IL test. IL tests were conducted in the laboratory of 3M Innovation Center which was established by EN standard. As expected ILs of half masks were lower than those of filtering facepiece mask. ILs of half masks and some filtering facepieces were significantly different in manufacturers. ILs of 1st class filtering facepieces were found to be much more than those of 2nd class and thus the result would cause wearers to get confused to select a mask. Four of six brands being no compliance with standards were thought that they should be tested again for certification because of a lot of differences from standards. There were no significant differences among ILs of five exercises. In 6 out of 13 brands lognormal distribution of ILs may be a better fit distribution and in 7 brands both lognormal and normal distributions were rejected. The result indicates that geometric mean may be better than arithmetic mean to establish standard.

The Bone Mineral Density Value According to the Operating Time of the Dual Energy X-ray (이중 에너지 엑스레이 흡수기의 가동 시간에 따른 골밀도 값의 평가)

  • Lee, Hae-Jung;Kim, Ho-Sung;Kim, Eun-Hye
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.40-45
    • /
    • 2010
  • Purpose: Recently, the performance of the X-ray tube was very much improved by the power generation of the technology. However, the overload of equipment is occurred by the increment of the equipment operating time according to the increment of the examination number of cases. The X-ray dose can change by heat occurrence of the X-ray tube due to this. Moreover, the change of the bone mineral density value is possible to occur. Therefore, We tries to whether the change of the bone mineral density value of each equipment according to the difference of the examination number of cases and operating time occur or not. Materials and Methods: The BMD value was measured by the Aluminum Spine Phantom and the European Spine Phantom in each equipment, in order to find out about the difference of the time general classification bone mineral density value by using the Dual energy X-ray absorptiometry. And after scanning each phantom by using X-ray dose meter (Unfors Mult-O-Meter), a dose was measured by the same condition. As to, an average and standard deviation were found and the change of each equipment much BMD value was compared and it evaluated. Results: $Mean{\pm}SD$ of each equipment by using the Aluminum Spine Phantom, A equipment was $1.174{\pm}0.002$, $1.171{\pm}0.005$, $1.173{\pm}0.005$, B equipment was $1.186{\pm}0.003$, $1.187{\pm}0.003$, $1.185{\pm}0.003$, C equipment was $1.180{\pm}0.003$, $1.182{\pm}0.004$, $1.183{\pm}0.002$, D equipment was $1.188{\pm}0.004$, $1.185{\pm}0.003$, $1.185{\pm}0.004$. By using the European Spine Phantom, A equipment was $1.143{\pm}0.006$, $1.153{\pm}0.009$, $1.161{\pm}0.003$, B equipment was $1.134{\pm}0.004$, $1.13{\pm}0.008$, $1.127{\pm}0.015$, C equipment was $1.143{\pm}0.006$, $1.134{\pm}0.01$, $1.133{\pm}0.006$, D equipment was $1.14{\pm}0.001$, $1.122{\pm}0.002$, $1.131{\pm}0.008$, altogether included in the normal range. Conclusion: There was no significant change of the BMD value of using a phantom by time zones. Therefore, if the quality control is made to use the extent management method of the equipment for beginning in the present application, the reliability of the BMD equipment will be able to be enhanced.

  • PDF

Fast Neutron Beam Dosimetry (속중성자선의 선량분포에 관한 연구)

  • 지영훈;이동한;류성렬;권수일;신동오;박성용
    • Progress in Medical Physics
    • /
    • v.8 no.2
    • /
    • pp.45-57
    • /
    • 1997
  • It is mandatory to measure accurately the dose distribution and the total absorbed dose of fast neutron for putting it to the clinical use. At present the methods of measurement of fast neutron are proposed largely by American Associations of Physicists in Medicine, European Clinical Neutron Dosimetry Group, and International Commission on Radiation Units and Measurements. The complexity of measurement, however, induces the methodological differences between them. In our study, therefore, we tried to establish a unique technique of measurement by means of measuring the emitted doses and the dose distribution of fast neutron beam from neutron therapy machine, and to invent a standard method of measurement adequate to our situation. For measuring the absorbed doses and the dose distribution of fast neutron beam, we used IC-17 and IC-18 ion chambers manufactured by A-150 plastic(tissue-equivalent material), IC-17M ion chamber manufactured by magnesium, TE gas and Ar gas, and RDM 2A electrometer. The magnitude of gamma-contamination intermingled with fast neutron beam was about 13% at 5cm depth of standard irradiated field, and increased as the depth was increased. At the central axis the maximum dose depth and 50% dose depth were 1.32cm and 14.8cm, respectively. The surface dose rate was 41.6-54.1% throughout the entire irradiated fields and increased as the irradiated fields were increased. Beam profile was that the horn effect of about 7.5% appeared at 2.5cm depth and the flattest at 10cm depth.

  • PDF

Establishment of Standard Methods for Marine Ecotoxicological Test (해양생태독성평가를 위한 표준시험방법 개발에 관한 연구)

  • Park, Gyung-Soo;Lee, Seung-Min;Han, Tae-Jun;Lee, Jung-Suk
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.2
    • /
    • pp.106-111
    • /
    • 2008
  • Six standard methods for marine ecotoxicological tests were established(or applicated) using marine decomposer, primary producers and consumers. Development processes referred to the standard methods established by USEPA(United States Environmental Protection Agency), international organizations and European methods. However, the standard test species were selected among the domestic species generally found in the Korean waters and sediments. The test methods provide the culture/maintenance of test species, test methods, reproducibility and quality acceptance criteria etc. A total of nine test species were designated including bioluminescent bacteria(Vibrio fischeri), diatom(Skeletonema costatum), seaweed(Ulva pertusa), rotifer(Brachionus plicatilis), benthic copepod(Tigriopus japonicus), benthic amphipods(Mandibulophoxus mai, Monocorophium acherusicum), and fishes(Oryzias latipes, Paralichthys olivaceus). These test species represent the decomposer, primary producer and consumers in marine trophic system in Korean coastal ecosystems, and we recommend the "battery test" including at least one species from the each trophic level for marine ecotoxicological test.

Non-linear fire-resistance analysis of reinforced concrete beams

  • Bratina, Sebastjan;Planinc, Igor;Saje, Miran;Turk, Goran
    • Structural Engineering and Mechanics
    • /
    • v.16 no.6
    • /
    • pp.695-712
    • /
    • 2003
  • The non-linear structural analysis of reinforced concrete beams in fire consists of three separate steps: (i) The estimation of the rise of surrounding air temperature due to fire; (ii) the determination of the distribution of the temperature within the beam during fire; (iii) the evaluation of the mechanical response due to simultaneous time-dependent thermal and mechanical loads. Steps (ii) and (iii) are dealt with in the present paper. We present a two-step computational procedure where a 2D transient thermal analysis over the cross-sections of beams are made first, followed by mechanical analysis of the structure. Fundamental to the accuracy of the mechanical analysis is a new planar beam finite element. The effects of plasticity in concrete, and plasticity and viscous creep in steel are taken into consideration. The properties of concrete and steel along with the values of their thermal and mechanical parameters are taken according to the European standard ENV 1992-1-2 (1995). The comparison of our numerical and full-scale experimental results shows that the proposed mechanical and 2D thermal computational procedure is capable to describe the actual response of reinforced concrete beam structures to fire.

Introduction of Directive 2002/44/EC

  • Park, Hee-Sok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.375-379
    • /
    • 2011
  • Objective: The aim of this paper is to introduce the Directive 2002/44/EC on the minimum health and safety requirements regarding the exposure of workers to the risks arising from vibration. Background: Human beings interact with machinery, and contact with vibration is commonplace. Unfortunately, continuous exposure to mechanical vibration can lead to physical injury. And standards are needed for identifying those at risk and for taking steps to mitigate the problem and reduce risk of injury. Method: The contents of the Directive were summarized and discussed, especially against its ISO counterparts. Results: The Directive deals with minimum safety and health prescriptions relative to workers' exposure to risks due to mechanical vibration. This directive specifies exposure limit values and action values. It also specifies employers' obligations with regard to determining and assessing risks, sets out the measures to be taken to reduce or avoid workers' exposure. Finally, it details how to make exposed workers aware of this issue. Conclusion: In spite of some limitations, it has recently been transcribed into all national laws of member States of European union. Application: The results of the paper might help to establish or update the domestic standards on vibration.

Development Strategy of Orbit Determination System for Korea's Lunar Mission: Lessons from ESA, JAXA, ISRO and CNSA's Experiences

  • Song, Young-Joo;Ahn, Sang-Il;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.247-264
    • /
    • 2014
  • In this paper, a brief but essential development strategy for the lunar orbit determination system is discussed to prepare for the future Korea's lunar missions. Prior to the discussion of this preliminary development strategy, technical models of foreign agencies for the lunar orbit determination system, tracking networks to measure the orbit, and collaborative efforts to verify system performance are reviewed in detail with a short summary of their lunar mission history. Covered foreign agencies are European Space Agency, Japan Aerospace Exploration Agency, Indian Space Research Organization and China National Space Administration. Based on the lessons from their experiences, the preliminary development strategy for Korea's future lunar orbit determination system is discussed with regard to the core technical issues of dynamic modeling, numerical integration, measurement modeling, estimation method, measurement system as well as appropriate data formatting for the interoperability among foreign agencies. Although only the preliminary development strategy has been discussed through this work, the proposed strategy will aid the Korean astronautical society while on the development phase of the future Korea's own lunar orbit determination system. Also, it is expected that further detailed system requirements or technical development strategies could be designed or established based on the current discussions.

QoS-Oriented Solutions for Satellite Broadcasting Systems

  • Vargas, Aharon;Gerstacker, Wolfgang H.;Breiling, Marco
    • Journal of Communications and Networks
    • /
    • v.12 no.6
    • /
    • pp.558-567
    • /
    • 2010
  • In this paper, we analyze the capability of satellite broadcasting systems to offer different levels of quality of service (QoS). We focus on the European telecommunications standards institute satellite digital radio and digital video broadcasting satellite handheld (DVB-SH) standards, which have recently been proposed for satellite broadcasting communications. We propose a strategy to provide different levels of QoS for the DVB-SH standard on the basis of an extension of the interleaving scheme, referred to as molded interleaver, which supports low latency service requirements for interactive services. An extensive analysis based on laboratory measurements shows the benefits of this solution. We also present a multilevel coding (MLC) scheme with multistage decoding designed for broadcasting communications as an alternative to the existing standards, where services with different levels of QoS are provided. We present a graphical method based on mutual information for the design and evaluation of MLC systems used for broadcasting communications. Extensive simulations for a typical satellite channel show the viability of the proposed MLC scheme. Finally, we introduce multidimensional constellations in the proposed MLC scheme in order to increase the number of different protection levels.

Analysis of Aviation Accident and Incident in Military Using the ECCAIRS 5 (ECCAIRS 5를 이용한 군 항공기 사고사례 분석)

  • Kim, Won-Kyou;Hong, Seung-Beom;Jie, Min-Seok;Hong, Gyo-Young;Ahn, Dong-Man;Choi, Youn-Chul
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.1
    • /
    • pp.80-86
    • /
    • 2013
  • In an effort to decrease aviation accident worldwide, development of aviation safety management has been sought through aviation index and standardization, both by establishing SMS(Safety Management System). It also needs to be done in the domestic. both study on SMS which ICAO recommends and setting the top priority safety goal, each differently classified by nations. Accordingly, defining safety index and developing continuous monitoring approach. Aircraft accident reporting system in Air Force does not operate in a open approach method due to its uniqueness related to mission achievement. Therefore, limits of utilizing the recent worldwide aircraft data sharing and analyzing results to prevent accident is inevitable. This paper introduces an overview of ECCAIRS 5 which become the standard for the recent worldwide aviation safety reporting and data exchange system. Also using ECCAIRS 5, aircraft accident cases of the Air Force are classified such as accident type, year, month, occurrence category, and flight phase. The result of the study will provide a guide line for utilizing the civil system in prevention of future military aviation accidents.