• 제목/요약/키워드: European standard method

검색결과 99건 처리시간 0.033초

ECCAIRS 5를 이용한 군 항공기 사고사례 분석 (Analysis of Aviation Accident and Incident in Military Using the ECCAIRS 5)

  • 김원규;홍승범;지민석;홍교영;안동만;최연철
    • 한국항공운항학회지
    • /
    • 제21권1호
    • /
    • pp.80-86
    • /
    • 2013
  • In an effort to decrease aviation accident worldwide, development of aviation safety management has been sought through aviation index and standardization, both by establishing SMS(Safety Management System). It also needs to be done in the domestic. both study on SMS which ICAO recommends and setting the top priority safety goal, each differently classified by nations. Accordingly, defining safety index and developing continuous monitoring approach. Aircraft accident reporting system in Air Force does not operate in a open approach method due to its uniqueness related to mission achievement. Therefore, limits of utilizing the recent worldwide aircraft data sharing and analyzing results to prevent accident is inevitable. This paper introduces an overview of ECCAIRS 5 which become the standard for the recent worldwide aviation safety reporting and data exchange system. Also using ECCAIRS 5, aircraft accident cases of the Air Force are classified such as accident type, year, month, occurrence category, and flight phase. The result of the study will provide a guide line for utilizing the civil system in prevention of future military aviation accidents.

Simultaneous Determination of Sulfonamides in Porcine and Chicken Muscle Using High Performance Liquid Chromatography with Ultraviolet Detector

  • Shim, You-Sin;Shin, Dong-Bin;Cho, Yong-Sun;Choi, Yun-Hee;Lee, Sang-Hee
    • Food Science and Biotechnology
    • /
    • 제18권6호
    • /
    • pp.1430-1434
    • /
    • 2009
  • The present study used the liquid extraction pretreatment method and developed a liquid chromatographyultraviolet detector (LC-UV) for the simultaneous determination of 14 sulfonamides (SAs) residues in porcine and chicken muscle. Linearity within a range of $50-150\;{\mu}g/kg$ was obtained with the correlation coefficient ($r^2$) of 0.9673-0.9997. The mean recovery of SAs was 55.9-109.7% (relative standard deviations; RSDs 1.7-17.3%) in porcine muscle and 52.8-112.4% (RSDs 2.3-16.9%) in chicken muscle. The limits of detection (LODs) and limits of quantification (LOQs) were 2-32 and $7-96\;{\mu}g/kg$ in porcine muscle, and 4-32 and $13-97\;{\mu}g/kg$ in chicken muscle, respectively. These values were lower than the maximum residue limits (MRLs) established by the European Union. The sum of all SAs residues present should be less than $100\;{\mu}g/kg$.

Capillary Electrochromatography with Liquid Crystal Crown Ether Modified Hybrid Silica Monolith for Analysis of Imidacloprid and Carbendazim in Tomatoes

  • Wang, Mingming;Feng, Rui;Shen, Jing;Chen, Hao;Zeng, Zhaorui
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2224-2228
    • /
    • 2012
  • This study describes the ability of capillary electrochromatography (CEC) for the determination of imidacloprid and carbendazim in tomato samples. A novel liquid crystal crown ether modified hybrid silica monolithic column was synthesized, characterized and developed as separation column for the first time. Baseline separation of imidacloprid and carbendazim could be achieved using a mobile phase containing 90% (v/v) 20 mmol/L phosphate buffer (pH 7.0) and 10% (v/v) acetonitrile. The matrix matched calibration curves were linear with correlation coefficient $r^2$ > 0.9998 in the range of 0.20-10.00 mg/L. The limits of detection for imidacloprid and carbendazim were 0.061 and 0.15 mg/kg, respectively, which were below the maximum residue limits established by the European Union as well as Codex Alimentarius. Average recoveries for imidacloprid and carbendazim varied from 101.6-108.0% with relative standard deviations lower than 6.3%. This method was applied to the analysis of tomatoes collected from local markets.

Rationalization of Network Segregation for Continuity of Financial Services Following COVID-19

  • Choi, Manyong;Kwak, Jin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권11호
    • /
    • pp.4163-4183
    • /
    • 2021
  • As measures for protecting users and ensuring security of electronic financial transactions, such as online banking, financial institutions in South Korea have implemented network segregation policies. However, a revision of such domain-centered standardized network segregation policies has been increasingly requested because of: 1) increased demand for remote work due to changes resulting from COVID-19 pandemic; and 2) the difficulty of applying new technologies of fintech companies based on information and communications technologies (ICTs) such as cloud services. Therefore, in this study, problems of the remote work environment arising from the network segregation policy currently applied to the financial sector in South Korea and those from the application of new ICTs such as fintech technology have been investigated. In addition, internal network protection policies of foreign financial sectors, such as those of the United States, United Kingdom, European Union, and Russia, and internal network protection policies of non-financial sectors, such as control systems, have been analyzed. As measures for the effective improvement of the current network segregation policy, we propose a policy change from domain-based to data-centric network segregation. Furthermore, to resolve threats of hacking at remote work, recently emerging as a global problem due to COVID-19 pandemic, a standard model for remote work system development applicable to financial companies and a reinforced terminal security model are presented, and an alternative control method applicable when network segregation is not applied is proposed.

Research and Calculate 29/34-Seat Passenger Cars to Ensure Safety for Occupants in the Event of a Collision According to ECE R94 Standards

  • Vu Hoang, Phuong;Nguyen Cong, Thanh;Nguyen Quoc, Tuan;Ta Hong Thanh, Tu
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제15권1호
    • /
    • pp.140-144
    • /
    • 2023
  • In recent years, there are so many serious crashes involving coaches, especially the frontal collision occupies 40% of the front of the vehicle, Frontal collisions account for 100% of the front of the vehicle affecting the driver and side-impact collisions that injure the person in the vehicle. Therefore, the research into improving and optimizing the structure is necessary for risk of injury for passengers in frontal accidents. In this paper, we have designed a Shock absorber that can absorb collision energy. Research using HYPERMESH software. to build the finite element model and calculate the meshing to suit the mesh size of 5mm. apply LS-DYNA software to calculate structural strength. In the study, for a vehicle to collide with a hard obstacle occupying 100% of the head of the vehicle. Then, the experimental design method, Minitab is used for find the structural parameters in the design. Improvement results showed that the acceleration of the impact on passengers and the driver is decreased by 55,17%. The mass of texture improvements is reduced by 11%, according to the requirements of European Standards ECE R94.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • 분석과학
    • /
    • 제36권2호
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

Determination of triflusal in raw material and capsules by HPLC

  • Pham, Thuy-Vy;Mai, Xuan-Lan;Lee, Ji-Hyeon;Lee, Jong-Ha;Jo, Hyeon-Ah;Kang, Jong-Seong;Woo, Mi Hee;Na, Dong-Hee;Chun, In-Koo;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제31권4호
    • /
    • pp.143-148
    • /
    • 2018
  • Currently, the Korean Pharmacopoeia (KP XI) recommends HPLC and potentiometric titration (which is less specific than HPLC) for the determination of triflusal content in capsules and raw materials, respectively. Additionally, the British Pharmacopoeia (BP 2017) and European Pharmacopoeia (EP 8.0), which include a monograph for triflusal in raw materials only, describe a titration method for the assay. The latest version of the United States Pharmacopoeia (USP 39) and Japanese Pharmacopoeia (JP 17) still have not published monographs for triflusal and its preparations. To improve the specificity and efficacy of the assay, we present an HPLC method to determine triflusal content in both raw materials and capsules. The proposed method was validated in accordance with the requirements of the International Conference on Harmonization. A good linear relationship was achieved for triflusal in the range of $200-1250{\mu}g/mL$ with a coefficient of determination of approximately 0.9996. The relative standard deviations (RSDs) of inter- and intraday precision were 0.73-1.12 % and 0.34-0.51 %, respectively. The recovery percentage of triflusal was in the range of 98.80-101.31 %. Because its system suitability, intermediate precision, and robustness were satisfactory, this method could be suitable for determining triflusal content in raw materials and capsules.

국제표준기국의 SW 개발 공정 인증을 위한 서비스 설계 및 인증 관리 도구: ADONIS (ADONIS: A Service Design and Certification Management Tool for Certification of Software Development Process in International Standard Organization)

  • 이성현;최영복;이문근
    • 서비스연구
    • /
    • 제8권1호
    • /
    • pp.59-72
    • /
    • 2018
  • 서비스 관점에서 국제표준기구가 요구하는 수준의 인증 서비스를 SW 개발과정에 도입하는 것은 매우 중요하다. 그 이유는 우리 산업에서 ICT가 차지하는 비중이 매우 높을 뿐만 아니라, ICT 관련 SW에 대한 국제적인 수준의 인증은 필수적이기 때문이다. 그리고 이를 위해서 ADONIS와 같은 과학적이며 체계적인 도구를 기반으로 한 인증 서비스가 절대적으로 요구된다. 본 논문에서는 이러한 시대적, 사회적 요구에 부응할 수 있는 하나의 새로운 방법 체계를 제시하였다. 이 체계는 우리 산업에 국제적인 수준에서 요구되는 SW의 안전성에 대한 인증 서비스를 제공하였고, 이러한 서비스는 다른 영역에도 적용될 수 있다. 이러한 체계를 설명하기 위해 EU우주항공국의 표준안 중 ECSS-E-40의 인증을 위한 서비스의 설계와 이에 대한 보증이 어떻게 이루어지는지 서비스 공학 측면에서 살펴보고, ADONIS를 통해서 보여주고자 한다. 본 논문은 E-40 표준안의 항목 중 SW의 명세와 검증에 관해 집중하며, 검증의 대상은 안전성(Safety)을 우선으로 한다.

VME 시스템 제어기의 FPGA 구현 (FPGA Implementation of VME System Controller)

  • 배상현;이강현
    • 한국정보처리학회논문지
    • /
    • 제4권11호
    • /
    • pp.2914-2922
    • /
    • 1997
  • 산업분야의 공장자동화와 자동 측정장비의 다중 프로세서 환경의 시스템 성능을 향상시키는 표준버스가 필요하다. VME 버스는 이러한 명세에 적합하지만, 소규모 패키지와 보드의 낮은 집적성 사양을 가지고 있다. 더욱이 보드와 반도체 집적성은 개발시간, 연구비용, 현장진단에 영향을 주는 중요한 문제로 대두되어 있다. 이러한 추세에 맞추어, 본 논문에서는 VME 버스와 제어기 모듈 사이의 주기능인 중재, 인터럽트, 인터페이스를 Revision C.1(IEEE std. P1014-1987)의 통합환경으로 구성하고, 설계된 VME 시스템 제어기를 Slot 1에 장착할 수 있도록 FPGA 상에 구현한다. 제어 및 기능 모듈의 동작은 VHDL의 mid-fixed 방식으로 코딩을 하고 검증하였다. 실험을 통하여 VME 시스템 제어기의 가장 중요한 동작인 버스 타이머의 버스 에러 신호가 $56{\mu}m$ 이내에 발생된 것과, 제어모듈과 기능모듈의 정확한 상호 동작도 확인하였다. 그러므로 구축된 VHDL 라이브러리는 VME 버스 기반시스템과 ASIC 설 계 에 응용할 수가 있다.

  • PDF

비대칭 배광을 갖는 LED 스포츠 조명 반사경 설계 (Design of a Reflector for LED Light Sources with Asymmetric Light Distribution)

  • 서진희;조예지;이현화;서재영;전원균;이한율;강동화;정미숙
    • 한국광학회지
    • /
    • 제29권6호
    • /
    • pp.253-261
    • /
    • 2018
  • 본 논문은 비대칭 배광을 가지는 LED 광원용 반사경 설계 방법에 대한 연구를 진행하였다. 스포츠 경기에서 광원을 중심으로 대칭 배광을 갖는 조명은 선수와 관중이 광원을 직접적으로 바라보게 되어 눈부심을 발생시키는 문제점이 있다. 이러한 문제점을 해결하기 위해 최적 기울기 각도를 도출하여 비대칭 배광을 갖는 반사경 설계를 진행하였다. 이후 테니스장 조명 규격에 맞게 배치하여 성능 분석을 진행하였고 유럽 표준 조명 등급의 Class 1을 만족하는 것을 확인하였다.