• 제목/요약/키워드: Etching test

검색결과 309건 처리시간 0.034초

제 2급 와동에서 구치부 복합레진의 미세변연누출에 관한 연구 (MICROLEAKAGE OF POSTERIOR PACKABLE COMPOSITE RESIN hi THE GINGIVAL MARGINS OF CLASS II CAVITIES)

  • 최수진;김미자;권혁춘
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.249-256
    • /
    • 2002
  • The use of flowable composite resins as liners in class II packable composite restoration has been suggested by some manufacturers. However, the contributions of this technique are unproven. The purpose of this study was to compare the gingival microleakage in class II packable composite restorations with or without the use of flowable composite resins as liners. Slot cavities were prepared on both proximals of 80 extracted human molars and randomly assigned to 8 groups of 20 each. The gingival margins were located at 1mm above CEJ in 80 cavities (group1-4) and 1mm below CEJ in 80 cavities (group5-8). The prepared teeth were mounted in the customized tray with adjacent teeth to simulate clinical conditions and metallic matrix band (Sectional matrix) and wooden wedges were applied. After acid etching and application of Single Bond, each group was restored with the following materials using incremental placement technique: Group 1,5 (Filtek P60), group 2, 3, 4 and group 6, 7, 8 (AeliteFlo, TetricFlow, Revolution/ Filtek P60). All specimens were thermocycled 500 times between 5$^{\circ}C$ and 55$^{\circ}C$ with 1 mimute dwell time, immersed 2% methylene blue dye for 24 hours and then rinsed with tab water. The specimens were embedded in clear resin and sectioned longitudinally through the center of restoration with a low speed diamond saw. Dye penetration at gingival margin was viewed at 20 magnification and analyzed on a scale of 0 to 4. Kruscal-Wallis One way analysis and Mann-Whitney Rank sum test were used to analyze the results. The results of this study were as follows. 1. The leakage values seen at the enamel margin were significantly lower than those seen at the dentin margin(P<0.05). 2. On the enamel margin, packable composite resins with flowable liners showed lower leakage than those without flowable liners, but there were no significant differences among the four groups(P>0.05). 3. On the dentin margin, four groups demonstrated moderate to severe leakage, and there were no significant differences in leakage values(P>0.05).

도말층 존재 유무에 따른 One-step 접착 시스템의 미세인장결합강도 (MICROTENSILE BONDING OF ONE-STEP ADHESIVES TO SHEARED AND NON-SHEARED DENTIN)

  • 송용범;진정희;이세준;이광원
    • Restorative Dentistry and Endodontics
    • /
    • 제27권3호
    • /
    • pp.299-309
    • /
    • 2002
  • The purposes of this study were to evaluate the microtensile bond strength of one-step adhesives accord ing to various dentin surface treatments and to observe the interface between resin(Z-100$^{TM}$) and dentin under SEM. In this study forty-five non-caries extracted human molars and three adhesive systems were used ; AlI-Bond 2(AB), One-Up Bond F(OU), AQ-Bond(AQ). ; In Group 1, 2, 3, AB was used and tooth surfaces were treated by smearing(S), ultrasonic cleansing(US), etching(E) respectively. In Group 4. 5, 6, One-Up Bond F was used and tooth surfaces were also treated as the same way above. In Groups 7, 8, 9, AQ Bond was used and tooth surfaces wet$.$e treated as the same way. Each specimen was prepared for microtensile bond testing, and were stored for 24hrs in 37$^{\circ}C$ distilled water. After that, microtensile bond strength for each specimen was measured. Specimens were fabricated to examine the failure patterns of interface between resin and dentin and observed under the SEM. The results were as follows ; 1. The results(mean$\pm$SD) of microtensile test were group 1, 25.69$\pm$4.31MPa; group 2, 40.93$\pm$10.94MPa; group 3, 47.65$\pm$8.85MPa; group 4, 35.98$\pm$9.14MPa; group 5, 39.66$\pm$8.45MPa; group 6, 43.26$\pm$13.01MPa; group 7, 25.07$\pm$4.2MPa;group 8, 30.4$\pm$4.74MPa;group 9, 33.61$\pm$7.88MPa. 2. One-Up Bond F was showed the highest value of 36.98$\pm$9.14MPa in dentin surface treatment with smearing, and there were significant differences to the other groups (p<0.05). 3. All-Bond 2 was showed the highest value of 40.93$\pm$10.94MPa in dentin surface treatment with ultra-sonic cleansing, but was no significant difference to One-Up Bond F(p>0.05) 4. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment with etch ing(10%phosphoric acid), and there were significant differences to the other groups(p<0.05). 5. All-Bond 2 was showed the highest value of 47.65$\pm$8.85MPa in dentin surface treatment according to manufacture's directions. but was no significant difference to One-Up Bond F(p>0.05). 6. AQ Bond was skewed the lowest microtensile bond strength with various dentin surface treatment, and the were significant differences to the other groups(p<0.05).

Fabrication, Estimation and Trypsin Digestion Experiment of the Thermally Isolated Micro Teactor for Bio-chemical Reaction

  • Sim, Tae-Seok;Kim, Dae-Weon;Kim, Eun-Mi;Joo, Hwang-Soo;Lee, Kook-Nyung;Kim, Byung-Gee;Kim, Yong-Hyup;Kim, Yong-Kweon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제5권3호
    • /
    • pp.149-158
    • /
    • 2005
  • This paper describes design, fabrication, and application of the silicon based temperature controllable micro reactor. In order to achieve fast temperature variation and low energy consumption, reaction chamber of the micro reactor was thermally isolated by etching the highly conductive silicon around the reaction chamber. Compared with the model not having thermally isolated structure, the thermally isolated micro reactor showed enhanced thermal performances such as fast temperature variation and low energy consumption. The performance enhancements of the micro reactor due to etched holes were verified by thermal experiment and numerical analysis. Regarding to 42 percents reduction of the thermal mass achieved by the etched holes, approximately 4 times faster thermal variation and 5 times smaller energy consumption were acquired. The total size of the fabricated micro reactor was $37{\times}30{\times}1mm^{3}$. Microchannel and reaction chamber were formed on the silicon substrate. The openings of channel and chamber were covered by the glass substrate. The Pt electrodes for heater and sensor are fabricated on the backside of silicon substrate below the reaction chamber. The dimension of channel cross section was $200{\times}100{\mu}m^{2}$. The volume of reaction chamber was $4{\mu}l$. The temperature of the micro reactor was controlled and measured simultaneously with NI DAQ PCI-MIO-16E-l board and LabVIEW program. Finally, the fabricated micro reactor and the temperature control system were applied to the thermal denaturation and the trypsin digestion of protein. BSA(bovine serum albumin) was chosen for the test sample. It was successfully shown that BSA was successfully denatured at $75^{\circ}C$ for 1 min and digested by trypsin at $37^{\circ}C$ for 10 min.

2개층 사질토지반에서 정방형 기초의 지지력 특성 (Characteristics of Bearing Capacity under Square Footing on Two-layered Sand)

  • 김병탁;김영수;이종현
    • 한국지반공학회논문집
    • /
    • 제17권4호
    • /
    • pp.289-299
    • /
    • 2001
  • 본 연구는 균질 및 2개층 비균질지반에서 사질토지반 상에 놓인 정방형 기초의 극한지지력과 침하에 대하여 고찰하였다. 본 연구는 얕은기초의 거동에 대한 정방형 기초의 크기, 지반 상대밀도, 기초 폭에 대한 상부층의 두께 비(H/B), 상부층 아래 경계면의 경사($\theta$) 그리고 지반강성비의 영향을 규명하기 위하여 모형실험을 수행하였다. 동일 상대밀도에서 지지력 계수($N_{{\gamma}}$)는 일정하지 않으며 기초 폭에 직접적으로 관련되며 지지력계수는 기초 폭이 증가함에 따라 감소하였다. 기초크기의 영향과 구속압력의 영향을 고려하는 Ueno 방법에 의한 극한지지력의 예측값은 고전적인 지지력 산정식보다 더 잘 일치하며 그 값은 실험값의 65% 이상으로 나타났다. $\theta$=$0^{\circ}$인 2개층 지반의 결과에 근거하여, 극한지지력에 대한 하부층 지반의 영향을 무시할 수 있는 한계 상부층 두께는 기초 폭의 2배로 결정되었다. 그러나, 73%의 상부층 상대밀도인 경우는 침하비($\delta$B) 0.05 이하에서만 이 결과가 유효하였다. 경계면이 경사진 2개층 지반의 결과에 근거하여, 상부층의 상대밀도가 느슨할수록 그리고 상부층의 두께가 클수록 극한지지력에 대한 경계면 경사의 영향은 크지 않는 것으로 나타났다. 경계면의 경사가 증가함에 따른 극한침하량의 변화는 경계면이 수평인 경우($\theta$=$0^{\circ}$)를 기준으로 0.82~1.2(상부층 $D_{r}$=73%인 경우) 그리고 0.9~1.07(상부층 $D_{r}$=50%인 경우) 정도로 나타났다.Markup Language 문서로부터 무선 마크업 언어 문서로 자동 변환된 텍스트를 인코딩하는 경우와 같이 특정한 응용 분야에서는 일반 문자열에 대한 확장 인코딩 기법을 적용할 필요가 있을 수 있다.mical etch-stop method for the etching of Si in TMAH:IPA;pyrazine solutions provides a powerful and versatile alternative process for fabricating high-yield Si micro-membranes. the RSC circle, but also to the logistics system in the SLC circle. Thus, the RSLC model can maximize combat synergy effects by integrating the RSC and the SLC. With a similar logic, this paper develops "A Revised System of Systems with Logistics (RSSL)" which combines "A New system of Systems" and logistics. These tow models proposed here help explain several issues such as logistics environment in future warfare, MOE(Measure of Effectiveness( on logistics performance, and COA(Course of Actions) for decreasing mass and increasing velocity. In particular, velocity in logistics is emphasized.

  • PDF

Al 7075/CFRP 적층 복합재료 제조를 위한 전처리 조건과 경화방법 연구 (Pre-treatment condition and Curing method for Fabrication of Al 7075/CFRP Laminates)

  • 이제헌;김영환
    • Composites Research
    • /
    • 제13권4호
    • /
    • pp.42-53
    • /
    • 2000
  • 차세대 항공기소재로 관심을 가지고 있는 Al 7075/CFRP 적층 복합재인 CARALL(CARbon ALuminum Laminates)하이브리드 복합소재 제조를 위한 중요조건중의 하나인 Al 표면처리조건과 경화방법에 대해 조사하였다. 항공기용 Al 전처리 중 대표적인 것으로 증기탈지, 크롬산 양극산화 피막처리, 황산-중크롬산 나트륨 에칭처리 및 인산 양극산화 피막처리공정이 있다. 본 실험에서는 상기 전처리 공정을 모두 항공 규격에 준해서 실시하여 Lap shear 및 Bell peel strength를 비교함으로써 효과적인 접착강도를 나타내는 표면처리 공정을 찾아내고, 시편의 자연표면상태를 그대로 관찰할 수 있는 AFM(Atomic Force Microscope)장비를 이용하여 각 전처리 시편의 표면형상을 측정함으로써 표면형상과 접착강도와의 상관관계를 고찰 하였다. 그리고 Al 표면처리와 별도로 Al과 접착제 및 탄소섬유 프리프레그를 동시에 경화시키는 방법과 탄소섬유 프리프레그를 미리 경화시킨후 다시 Al과 탄소섬유 라미네이트를 접착필름을 이용하여 재 접착시키는 이차 경화법을 적용하여 상호 접착강도 및 물성을 비교하였다. 또한 이차경화법에서의 오토클레이브 압력 변화와 DMA(Dynamic Mechanical Analysis) 장비를 이용한 접착필름의 유리전이온도($T_g$) 측정을 통해 효과적인 공정압력 및 접착내구성 유지에 필요한 최소 경화시간을 파악하였다. 상기 결과로부터 정밀 치수관리가 필요하며 고접착강도, 내구성 항공기 부품을 제작하기 위한 알루미늄 표면처리 공정과 복합재 경화공정 조건을 제시하고자 하였다.

  • PDF

CFRP Chip 표면처리에 따른 페놀복합재료의 강화, 내열성 및 난연성 향상 (Reinforcement, Thermal and Fire Retardant Improvement of Phenolic Composites by Surface Treatment of CFRP Chip)

  • 권동준;왕작가;구가영;박종만
    • 접착 및 계면
    • /
    • 제13권2호
    • /
    • pp.58-63
    • /
    • 2012
  • 탄소섬유강화플라스틱(CFRP)의 홀 가공 시 chip이 발생된다. 이때 발생되는 chip은 단순 폐기용 차원이 아닌 미세탄소섬유와 에폭시의 조성으로 이루어져 있다. Chip을 강화재로 활용하기 위해서는 탄소섬유만의 조성을 이루어야 고분자 기지와 계면접착력이 증가될 수 있다. Chip 내 탄소섬유의 길이를 일정하게 하기 위해 막자 사발을 이용한 절단 과정 후 $H_2O_2$를 이용한 표면처리를 하여 탄소섬유에 붙어있는 에폭시를 제거하였다. Chip을 이용하여 페놀수지를 기지로 한 페놀복합재료를 제조하였으며, 내열성 및 난연성 재료로 활용 가능성을 평가하였다. 기존의 페놀보다 표면처리를 한 chip복합재료가 기계적, 열적 물성이 향상됨을 확인하였으며, 젖음성 평가를 이용하여 표면물성에 따른 재료의 물성을 평가하였다. 불균질한 표면 조성에 의해 표면 거칠기가 달라지기 때문에 페놀복합재료의 접촉각이 증가되었다. 난연성 평가는 ASTM D635-06 방법으로 수행하였다. 평가결과, chip의 첨가 및 표면처리의 영향에 의해 난연성이 향상되었다.

AH-26 및 산화아연유지놀 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향 (The Influence of AH-26 and Zinc Oxide-Eugenol Root Canal Sealer on the Shear Bond Strength of Composite Resin to Dentin)

  • 조주연;진명욱;김영경;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제31권3호
    • /
    • pp.147-152
    • /
    • 2006
  • AH-26 근관실러가 상아질에 대한 복합레진의 전단결합강도에 미치는 영향을 평가하기 위하여 144개의 발거된 대구치를 실린더형의 몰드에 매식한 다음 치관부의 상아질 표면을 노출시킨 후 편평하게 연마하고 AH-26을 도포한 군, ZOE paste를 도포한 군 및 실러를 도포하지 않은 대조군으로 나누어 One-step 상아질 접착제를 처리한 후에 Charisma (Heraeus Kulzer Germany) 복합레진을 적용하고 광중합시켰다. 시편을 분리하여 $37^{\circ}C$ 항온조에 24시간 보관후 Instron test machine (Model 4202, Instron Corp. USA)을 이용하여 시편의 전단 결합 강도를 측정하고 one-way ANOVA 및 Tukey's studentized rank test로 통계 분석 하였다. AH-26 근관실러로 처리한 군과 대조군은 ZOE 근관실러 처리군에 비해 유의하게 놓은 접착강도를 나타내었다(p<0.05). AH-26 근관실러 처리군과 아무 처리하지 않은 대조군 사이에는 결합강도에 있어 유의한 차이를 나타내지 않았다 (p>0.05). 본 연구의 조건에서는 ZOE 근관실러는 상아질에 대한 복합레진의 전단결합강도를 저하시키는 반면 AH-26 근관실러는 유의한 영향을 미치지는 않는 것으로 보인다. 따라서 임상에서 근관실러로 AH-26을 사용한 근관충전 후에는 즉시 복합레진 코어를 해 주어도 결합력에 저해가 없을 것으로 여겨진다.

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2008년도 Spring Scientific Meeting(the 129th) of Korean Academy if Conservative Dentistry
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존치질의 두께 (법랑질 /법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교 평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, $1{\sim}3$군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $Z-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

  • PDF

복합 레진으로 수복된 세 가지 첨와형태 와동의 파절 저항성에 관한 연구 (FRACTURE RESISTANCE OF THE THREE TYPES OF UNDERMINED CAVITY FILLED WITH COMPOSITE RESIN)

  • 최훈수;신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제33권3호
    • /
    • pp.177-183
    • /
    • 2008
  • 심미성 복합레진은 자연 치질을 보존시키며 나아가 잔존 치질의 강도를 강화시켜 준다. 복합레진 수복시 더 많은 치질을 남기기 위해 첨와 (undercut) 형태의 교합면 치질을 남긴 채 복합레진으로 수복하는 경우가 많으나, 어느 정도 강도가 복원되는지에 대해서는 잘 알려져 있지 않다. 이에 본 연구에서는 첨와 형태의 와동을 잔존 치질의 두께 (법랑질 / 법랑질과 상아질)에 따라 형성하고 복합레진으로 충전한 경우, 수복된 치아의 파절 저항성을 손상이 없는 자연치와 비교평가하였다. 상악 대구치 40개의 교합면을 편평하게 삭제한 후 방사선 사진에서 치수각의 위치를 확인하였다. 대상 치아를 각 10개씩 4개군으로 분류하였으며, 1$\sim$3군은 실험군으로 모두 협측에 깊이 7 mm, 근원심 폭경 5 mm의 첨와 형태 와동을 형성하였고, 와동저에서 치수각까지의 거리를 약 0.5 mm로 유지하였으며 교합면쪽의 치질 두께를 달리하였다. 1군은 법랑질과 소량의 상아질로 구성된 치질 두께를 1 mm, 2군은 법랑질과 상아질의 두께를 1.5 mm, 3군은 법랑질과 상아질의 두께를 2 mm가 되도록 하였고, 4군은 건전한 자연치를 와동형성 없이 대조군으로 사용하였다. 두께 측정은 방사선 사진을 스캔한 후 길이 확대 프로그램을 이용하였다. 각 와동을 37% 인산으로 산부식한 다음 단일병 접착제 Single $Bond^{TM}$ (3M/ESPE, USA)를 적용하였고 혼합형 복합레진 Filtek $SZ-250^{TM}$ (3M/ESPE, USA)을 사용하여 적층 충전하였다. 치아를 실온에서 증류수에 24시간 동안 보관한 다음 Sof-Lex system (3M/ESPE, USA)을 사용하여 연마하였다. 이후 자가중합형 레진에 교합면을 기저부에 평행한 상태로 치근부를 매몰한 다음 Universal testing machine (Zwick Z010, Germany)에서 지름 3 mm의 staineless steel rod를 1 mm/min의 cross-head speed로 하중을 가하여 파절 강도를 측정하였다. 통계 분석은 95% 유의 수준의 One-way ANOVA와 Tukey test를 이용하였으며 다음과 같은 결과를 얻었다. 1. 와동 형성 후 복합레진을 수복한 군들은 대조군에 비해 약 75%의 파절 강도를 보였다. 2. 교합면쪽 잔존 치질의 두께에 따른 파절 저항은 유의한 차이를 보이지 않았다 (p > 0.05). 복합레진을 이용하여 첨와 형태의 와동을 수복한 후 파절 강도를 측정한 결과 건전 치아보다는 강도가 낮았지만, 상부의 잔존 치질이 대부분 법랑질로 이루어진 경우에도 복합 레진으로 수복하면 건전 치아 파절 강도의 75%까지 유지할 수 있다는 결론을 얻었다.

세라믹 브라켓 부착 시 레이저를 이용한 포세린 표면처리 효과 (The effect of using laser for ceramic bracket bonding of porcelain surfaces)

  • 안경미;손동석
    • 대한치과교정학회지
    • /
    • 제38권4호
    • /
    • pp.275-282
    • /
    • 2008
  • 본 연구는 포세린 표면에 $CO_2$ 레이저를 조사하여 세라믹 브라켓을 부착 후 전단결합강도를 측정하고, 산부식처리 및 샌드블라스트 등의 일반적인 방법을 시행하여 그 결과를 비교 분석하여 레이저 표면처리의 효과를 연구하고자 시행되었다. 90개의 포세린($8\;{\times}\;8\;{\times}\;4\;mm$) 시편을 제작하여 각각 10개씩 9개군으로 나누었다. 대조군(C)으로 아무런 표면처리를 하지 않은 글레이즈 표면을 사용하였으며, 실험군은 인산 처리군(OFA), 인산과 silane 처리군(OFA + S), 샌드블라스팅 처리군(SB), 샌드블라스팅과 silane 처리군(SB + S), 레이저 처리군(L), 레이저와 silane 처리군(L + S), 불산 처리군(HFA), 불산과 silane 처리군(HFA + S)으로 분류하였다. 만능시험기를 이용하여 전단결합강도를 측정하고 그 파절양상을 비교 분석한 결과 불산과 silane을 동시에 처리한 군에서 가장 높은 값($13.92\;{\pm}\;1.92\;MPa$)을 보였으며, 측정값은 SB + S ($10.16\;{\pm}\;1.27\;MPa$), HFA (10.09\;{\pm}\;1.07\;MPa$), L + S ($8.25\;{\pm}\;1.24\;MPa$), L ($7.86\;{\pm}\;0.96\;MPa$), OFA + S ($7.22\;{\pm}\;1.09\;MPa$), SB ($3.41\;{\pm}\;0.37\;MPa$), OFA ($2.81\;{\pm}\;0.37\;MPa$), 대조군($2.46\;{\pm}\;1.36\;MPa$) 순이었다. 브라켓 부착 시 치과용 레이저를 이용한 포세린의 표면처리 결과 전단결합강도의 값은 임상적으로 받아들여질 만한 수치를 보였으며 레이저와 silane을 동시에 처리한 군과는 통계적으로 유의할 만한 차이를 보이지 않았다(p > 0.05). 이상의 연구결과는 포세린 표면에 세라믹 브라켓 부착 시 2-watt의 $CO_2$ 레이저를 사용하여 전처리를 하는 방법은 시간절약의 관점에서 임상적으로 표면 전처리의 적절한 치료 대안이 될 수 있음을 보여주었다.