• Title/Summary/Keyword: Estimated Radiation dose

Search Result 271, Processing Time 0.029 seconds

Effects of Gamma-ray and Chemical Mutagens on the Germination and Seedling Growth in Stevia rebaudiana Bert. (감마선 및 화학적 돌연변이원 처리가 스테비아 (Stevia rebaudiana Bert.)의 종자 발아 및 초기 생장에 미치는 영향)

  • Yoon, Tai-Young;Kim, Ee-Youb;Kim, Young-Ho;Choi, Gin-Su;Hyun, Kyung-Sup;Seong, Yoon-Hee;Jo, Han-Jig;Kim, Dong Sub;Kang, Si-Yong;Ko, Jeong-Ae
    • Journal of Radiation Industry
    • /
    • v.6 no.2
    • /
    • pp.189-197
    • /
    • 2012
  • This study was carried out to develop the improved useful mutants for yield or composition of stevia plants using the gamma ray or chemical mutagens treatments. The seeds of stevia 'Suwon No. 11' were irradiated up to 400 Gy of gamma ray. Chemical mutagens were treated on the seeds of the 'Suwon No. 11' using 0.07% colchicine, 10 mM sodium azide, or 10 mM NMU for various durations. The germination rate, and shoot and root growth of seedling were estimated at 30 days after gamma ray irradiation or chemical mutagen treatment, and the plant height, the number of branches, and leaf length and width were examined at 3 months after mutagenesis treatments. In the case of gamma ray treatments, the germination rate and early-stage growth were decreased as the increase of radiation dose, and the 50% lethal dose was found to be 200 Gy. the plant height was decreased as the increase of radiation dose, while the number of branches per plant and leaf length were increased. Leaf shape was modified to the relatively longer one compared to the control, which was identified more apparently at the treatments of higher than 150 Gy. In the treatment of chemical mutagens, the rate of germination and survival were decreased as the increase of incubation time. The 50% lethal dose for germination rate were identified as the conditions of the 15 hours incubation in 0.07% colchicine, the 4 hrs in 10 mM sodium azide, and the 2 hrs in 10 mM NMU, in the three chemical mutagens treatments. Chemical mutagens had no influence on shoot growth, while root growth was increased, especially as the incubation time was extended. The highest root growth occurred in the NMU treatment at 6 hrs incubation time. The plant height was decreased as the increase of incubation time in the chemical mutagens treatments. Among the chemical mutagens, NMU was the most effective to induce the mutants with long-shaped or the least lobed leaves.

Institutional Experience of Interstitial Brachytherapy for Head and Neck Cancer with a Comparison of High- and Low Dose Rate Practice

  • Mohanti, Bidhu Kalyan;Sahai, Puja;Thakar, Alok;Sikka, Kapil;Bhasker, Suman;Sharma, Atul;Sharma, Seema;Bahadur, Sudhir
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.2
    • /
    • pp.813-818
    • /
    • 2014
  • Aims: To describe our institutional experience with high dose rate (HDR) interstitial brachytherapy (IBT) compared with previously reported results on the low dose rate (LDR) practice for head and neck cancer. Materials and Methods: Eighty-four patients with oral cavity (n=70) or oropharyngeal cancer (n=14) were treated with 192Ir HDR-IBT. Seventy-eight patients had stage I or II tumour. The patients treated with IBT alone (n=42) received 39-42 Gy/10-14 fractions (median=40 Gy/10 fractions). With respect to the combination therapy group (n=42), prescription dose comprised of 12-18 Gy/3-6 fractions (median=15 Gy/5 fractions) for IBT and 40-50 Gy/20-25 fractions (median=50 Gy/25 fractions) for external radiotherapy. Brachytherapy was given as 2 fractions per day 6 hours apart with 4 Gy per fraction for monotherapy and 3 Gy per fraction for combination therapy. Results: Four patients were not evaluable in the analysis of outcome. The primary site relapse rates were 23.8% (10/42) and 68.4% (26/38) in patients treated with IBT alone and combination therapy, respectively (p<0.001). Salvage surgery was performed in 19 patients. The 5-year local control rate was estimated at 62% and the disease-free survival (DFS) rate at 52% for all patients. Local control with respect to T1 and T2 tumours was 84% and 42%, respectively. Conclusions: Our present series on HDR-IBT and the previous report on LDR-IBT for head and neck cancer demonstrated similar DFS rates at 5 years (52%). The rate of regional failure in node-negative patients was <20% in both of our series. HDR-IBT offers similar results to LDR-IBT for head and neck cancer.

In vivo and in vitro Confirmation of Dose Homogeneity in Total Body Irradiation with Thermoluminescent Dosimeter (인체 및 인형 팬톰에서 전신방사선조사시 열형광선량계(TLD)를 이용한 선량분포 균일성 확인)

  • Chie Eui Kyu;Park Suk Won;Kang Wee-Saing;Kim Il Han
    • Radiation Oncology Journal
    • /
    • v.17 no.4
    • /
    • pp.321-328
    • /
    • 1999
  • Purpose : Total body irradiation (TBI) or whole body irradiation is used to acquire immune suppression, to treat malignant lymphoma and leukemia, and as an conditioning regimen for bone marrow transplantation. For these purposes, many methods were developed to obtain homogenous dose distribution. The objective of this study was to analyze and confirm the accuracy and the homogeneity of the treatment setup, the parallel opposed lateral technique, currently used in Seoul National University Hospital. Materials and Metheods : Surface dose data, measured with a thermoluminescent dosimeter, of 8 patients among 10 patients, who were given total body irradiation with the parallel opposed lateral technique between September 1996 to August 1998, at Seoul National University Hospital were analyzed. Surface doses were measured at the head, neck, axilla, thigh, and ankle level. Surface and midline doses were measured with similar set-up and technique in the Humanoid phantom. Results : Measured surface doses relative to prescribed dose for the head, neck, axilla, thight, and ankle leve were $91.3{\pm}7.8,{\;}98.3{\pm}7.5,{\;}95.1{\pm}6.3,{\;}98.3{\pm}5.5$, and $95.3{\pm} 6.3\%$, respectively. The midline doses of the head, neck, axilla, thigh, and ankle level estimated from the surface-to-midline ratios in the Humanoid Phantom were $103.4{\pm}9.0,{\;}107.8{\pm}10.5,{\;}91.1{\pm}6.1,{\pm} 93.8{\pm}4.5,{\;}and{\;}104.5{\pm}9.3\%$, respectively. Measured surface doses and estimated midline doses ranged from $-8.9\%$ to $+7.8\%$. Midline doses at the neck and the axilia level deviated more than $5\%$ from the prescribed doses. The difference of the estimated midline doses at the neck and the axilla level and the actual doses were attributed to the thickness differences between the Humanoid phantom and the patients. Conclusion Distribution of the midline doses as well as the suface doses were measured to be within $-8.7\~{\pm}7.8\%$ range. Actual dose distribution in the patient is expected to be better than the measured dose range mainly attributed to thickness difference between the patient and the Humanoid phantom.

  • PDF

Significantly Low Effective Dose from 18FDG PET/CT Scans Using Dose Reducing Strategies: "Lesser is Better"

  • uz Zaman, Maseeh;Fatima, Nosheen;Zaman, Areeba;Zaman, Unaiza;Tahseen, Rabia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3465-3468
    • /
    • 2016
  • Background: Fluorodeoxyglucose ($^{18}FDG$) PET/CT imaging has become an important component of the management paradigm in oncology. However, the significant imparted radiation exposure is a matter of growing concern especially in younger populations who have better odds of survival. The aim of this study was to estimate the effective dose received by patients having whole body $^{18}F$-FDG PET/CT scanning as per recent dose reducing guidelines at a tertiary care hospital. Materials and Methods: This prospective study covered 63 patients with different cancers who were referred for PET/CT study for various indications. Patients were prepared as per departmental protocol and 18FDG was injected at 3 MBq/Kg and a low dose, non-enhanced CT protocol (LD-NECT) was used. Diagnostic CT studies of specific regions were subsequently performed if required. Effective dose imparted by 18FDG (internal exposure) was calculated by using multiplying injected dose in MBq with coefficient $1.9{\times}10^{-2}mSv/MBq$ according to ICRP publication 106. Effective dose imparted by CT was calculated by multiplying DLP (mGy.cm) with ICRP conversion coefficient "k" 0.015 [mSv / (mG. cm)]. Results: Mean age of patients was $49{\pm}18$ years with a male to female ratio of 35:28 (56%:44%). Median dose of 18FDG given was 194 MBq (range: 139-293). Median CTDIvol was 3.25 (2.4-6.2) and median DLP was 334.95 (246.70 - 576.70). Estimated median effective dose imparted by $^{18}FDG$ was 3.69 mSv (range: 2.85-5.57). Similarly the estimated median effective dose by low dose (non-diagnostic) CT examination was 4.93 mSv (range: 2.14 -10.49). Median total effective dose by whole body 18FDG PET plus low dose non-diagnostic CT study was 8.85 mSv (range: 5.56-13.00). Conclusions: We conclude that the median effective dose from a whole body 18FDG PET/CT in our patients was significantly low. We suggest adhering to recently published dose reducing strategies, use of ToF scanner with CT dose reducing option to achieve the lower if not the lowest effective dose. This would certainly reduce the risk of second primary malignancy in younger patients with higher odds of cure from first primary cancer.

Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

  • Seohyeon An;Sang-il Pak;Seonghoon Jeong;Soonki Min;Tae Jeong Kim;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.80-87
    • /
    • 2022
  • Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle's linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam's Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range.

Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode (탄소막 마이크로필름을 이용한 다채널 전리함 개발에 관한 연구)

  • Shin Kyo Chul;Yun Hyong Geun;Jeong Dong Hyeok;Oh Yong Kee;Kim Jhin Kee;Kim Ki Hwan;Kim Jeung Kee
    • Progress in Medical Physics
    • /
    • v.16 no.3
    • /
    • pp.111-115
    • /
    • 2005
  • We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5$\%$, linearity was less than 0.5$\%$, and dose rate effect was less than 0.7$\%$. In addition the effect of dose variation from other chambers was estimated to maximum 0.8$\%$ approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.

  • PDF

The Construction of Solid State Detector System Using Commercially Available Diode and Its Application (정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구)

  • 신동오;홍성언;이병용;이명자
    • Progress in Medical Physics
    • /
    • v.1 no.1
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM PANORAMIC RADIOGRAPHY TO THE CRITICAL ORGANS OF HEAD AND NECK REGION (파노라마 촬영시의 두경부 주요기관의 등가선량, 유효선량 및 위험도)

  • Cho Bong-Hae;Nah Kyung-Soo;Lee Ae-Ryeon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.437-445
    • /
    • 1995
  • The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. the equivalent and effective dose in adult mode were 837μSv and 20.93μSv, those in child mode were 462μSv and 11.54μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.21μSv in adult mode, 20.14μSv in child mode. From these datas, the probabilities of stochastic effect from adult and child mode were 2.50x10/sup -6/ and 1.47x10/sup -6/. 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million panoramic examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult and child mode from these examinations.

  • PDF

Determination of indoor doses and excess lifetime cancer risks caused by building materials containing natural radionuclides in Malaysia

  • Abdullahi, Shittu;Ismail, Aznan Fazli;Samat, Supian
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.325-336
    • /
    • 2019
  • The activity concentrations of $^{226}Ra$, $^{232}Th$, and $^{40}K$ from 102 building materials samples were determined using a high-purity germanium (HPGe) detector. The activity concentrations were evaluated for possible radiological hazards to the human health. The excess lifetime cancer risks (ELCR) were also estimated, and the average values were recorded as $0.42{\pm}0.24{\times}10^{-3}$, $3.22{\pm}1.83{\times}10^{-3}$, and $3.65{\pm}1.85{\times}10^{-3}$ for outdoor, indoor, and total ELCR respectively. The activity concentrations were further subjected to RESRAD-BUILD computer code to evaluate the long-term radiation exposure to a dweller. The indoor doses were assessed from zero up to 70 years. The simulation results were $92{\pm}59$, $689{\pm}566$, and $782{\pm}569{\mu}Sv\;y^{-1}$ for indoor external, internal, and total effective dose equivalent (TEDE) respectively. The results reported were all below the recommended maximum values. Therefore, the radiological hazards attributed to building materials under study are negligible.