• Title/Summary/Keyword: Estimate Criteria

Search Result 630, Processing Time 0.031 seconds

The Study on Affecting Subject Accomplishment by Noise (소음이 과제수행에 미치는 영향에 관한 연구)

  • Kim, Sung-Cheol;Park, Keun-Sang;Kim, Kwan-Woo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.1
    • /
    • pp.121-128
    • /
    • 2010
  • The purpose of this study is to confirm the impact of noise on subject accomplishment as well as physical/mental load, and evaluates the effects of noise-masking and earplug. 15 college students participate in the test, and the comparison is performed by executing four projects according to conditional categories of noise environments; control condition, noise condition, earplug condition, and noise-masking condition. Noise in the field site of the H manufacturer was used as the noise source, the general job aptitude test which consist of linguistic ability, math ability, perception ability, reasoning ability was used as the task of this project. To estimate physical/mental load evaluation, we used the heart rate R-R interval, Criteria flicker fusion frequency(CFF) and measured NASA-TLX workload for subjective evaluation. As the research outcome, it is shown that there is a meaningful difference for the project task score, dropping rate of CFF, the heart rate, and NASA-TLX subjective evaluation score according to conditions of noise environment. Therefore, the impact of noise on capability of subject accomplishment as well as physical/mental load was confirmed along with the effects of using earplug and noise-masking.

Estimation of Soft Ground Characteristics using the Piezo-Cone Penetration Tests(CPTu) on Honam High-Speed Railway Planning Line (호남고속철도 계획노선에서의 피에조콘 관입시험(CPTu)에 의한 연약지반 특성 평가)

  • Lee, Il-Wha;Kwon, Oh-Jung;Kwen, Jin-Su;Min, Kyoung-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1796-1801
    • /
    • 2007
  • Piezocone penetration testing(CPTu) results such as cone resistance$(q_c)$, sleeve friction$(f_s)$, and pore pressure(u), have been carried out at 5 sites in Honam high-speed railway areas of Korea, in order to continuously estimate the characteristics of soil layers and the undrained shear strength$(S_u)$ in a soft ground. For the applications of the conventional CPTu results to undrained shear strength, the cone factors$(N_{kt})$ were deduced based on Field vane tests, and Monte-Carlo Simulation(MCS). Moreover the correlations of the undrained shear strength of CPTu by soil depths were compared and revised with the results of triaxial compression(UU test), field vane and Dilatometer tests(DMT). The depths of soft foundation at 5 sites in Honam high-speed railway areas were calculated based on the results of the various field tests in addition CPTu. The applicability of CPTu for a soft foundation criterion referred to the criteria of high-speed railway and related agencies in Korea was evaluated.

  • PDF

Correlation analysis and time series analysis of Ground-water inflow rate into tunnel of Seoul subway system

  • 김성준;이강근;염병우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.254-257
    • /
    • 2003
  • Statistical analysis is performed to estimate the correlations between geological or geographical factor and groundwater inflow rates in the Seoul subway system. Correlation analysis shows that among several geological and geographical factors fractures and streams have most strong effects on inflow rate into tunnels. In particular, subway line 5∼8 are affected more by these factors than subway line 1∼4. Time series analysis is carried out to forecast groundwater inflow rate. Time series analysis is a useful empirical method for simulation and forecasts in case that physical model can not be applied to. The time series of groundwater inflow rates is calculated using the observation data. Transfer function-noise model is applied with the precipitation data as input variables. For time series analysis, statistical methods are performed to identify proper model and autoregressive-moving average models are applied to evaluation of inflow rate. Each model is identified to satisfy the lowest value of information criteria. Results show that the values by result equations are well fitted with the actual inflow rate values. The selected models could give a good explanation of inflow rates variation into subway tunnels.

  • PDF

Verification of Insulation Design for Three Phase Enclosure Type EHV Class GIB by 3D Electric Field Analysis (3차원 전계해석에 의한 3상일괄형 초고압 GIB의 절연설계 검증)

  • Chong, J.K.;Park, K.Y.;Shin, Y.J.;Chang, K.C.;Song, K.D.;Song, W.P.;Kweon, K.Y.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.482-484
    • /
    • 1995
  • In designing three phase enclosure type EHV class gas insulated bus (GIB), it is essential to estimate the magnitude and the position where the maximum electric field strength occur. The improvement of insulation design can only be initiated after those informations have been obtained. In this paper, the calculated electric field strength for three phase GIB of HICO 362kV 63kA GIS is presented. The result shows that the designed insulator has enough margin compared with the design criteria.

  • PDF

Research about Adverse Effect of Spinal Manipulation Therapy : Systemic Review of Literature in Korea and Pubmed (척추수기치료의 부작용에 대한 국내 및 국외 현황 비교)

  • Jeong, Seon-Yeong;Lee, Cha-Ro
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.10 no.1
    • /
    • pp.15-33
    • /
    • 2015
  • Objectives : The aim of this systemic review was to summarize and compare adverse effect of spinal manipulation at domestic and abroad. Methods : We searched articles in Korean databases and Pubmed. We selected and analysed the articles met inclusion criteria. Results : 51 cases were included. 32 cases in Pubmed show that adverse effect related to cervical rotation and high velocity low amplitude(HVLA) thrust manipulation. It leads to severe adverse effect and sequela about vascular. While, 19 cases in Korean articles shows that domestic spinal manipulation is more safe becase of lower use of high velocity low amplitude(HVLA) thrust. It leads to low incidence of vascular adverse effect and no sequela. Conclusions : We concluded that Chuna is difficult manipulation because of possibility of adverse effect. Chuna is recommended to be taken by licensed medical practitioners who are skilled and complete the regular curriculum. Further studies like meta analysis about spinal manipulation are needed to estimate incidence of adverse effect. And adverse effects are going to be collected continually through randomized controlled trials(RCT) related to spinal manipulation.

Inverse Model Parameter Estimation Based on Sensitivity Analysis for Improvement of PM10 Forecasting (PM10 예보 향상을 위한 민감도 분석에 의한 역모델 파라메터 추정)

  • Yu, Suk Hyun;Koo, Youn Seo;Kwon, Hee Yong
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.7
    • /
    • pp.886-894
    • /
    • 2015
  • In this paper, we conduct sensitivity analysis of parameters used for inverse modeling in order to estimate the PM10 emissions from the 16 areas in East Asia accurately. Parameters used in sensitivity analysis are R, the observational error covariance matrix, and B, a priori (background) error covariance matrix. In previous studies, it was used with the predetermined parameter empirically. Such a method, however, has difficulties in estimating an accurate emissions. Therefore, an automatically determining method for the most suitable value of R and B with an error measurement criteria and posteriori emissions accuracy is required. We determined the parameters through a sensitivity analysis, and improved the accuracy of posteriori emissions estimation. Inverse modeling methods used in the emissions estimation are pseudo inverse, NNLS (Nonnegative Least Square), and BA(Bayesian Approach). Pseudo inverse has a small error, but has negative values of emissions. In order to resolve the problem, NNLS is used. It has a unrealistic emissions, too. The problems are resolved with BA(Bayesian Approach). We showed the effectiveness and the accuracy of three methods through case studies.

A Study on Development of a Plugging Margin Evaluation Method Taking Into Account the Fouling of Shell-and-Tube Heat Exchangers

  • Hwang, Kyeong-Mo;Jin, Tae-Eun;Kim, Kyung-Hoon
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1934-1941
    • /
    • 2006
  • As the operating time of heat exchangers progresses, fouling caused by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of Korean nuclear power plants have been analyzed in terms of heat transfer rate and overall heat transfer coefficient as a means of heat exchanger management. Except for fouling resulting from the operation of heat exchangers, all the tubes of heat exchangers have been replaced when the number of plugged tubes exceeded the plugging criteria based on design performance sheet. This paper describes a plugging margin evaluation method taking into account the fouling of shell-and-tube heat exchangers. The method can evaluate thermal performance, estimate future fouling variation, and consider current fouling level in the calculation of plugging margin. To identify the effectiveness of the developed method, fouling and plugging margin evaluations were performed at a component cooling heat exchanger in a Korean nuclear power plant.

Optimum Failure Prediction Model of Steam Generator Tube with Two Parallel Axial Through-Wall Cracks (두개의 평행한 축방향 관통균열이 존재하는 증기발생기 세관의 최적 파손예측모델)

  • Lee, Jin-Ho;Song, Myung-Ho;Choi, Young-Hwan;Kim, Nak-Cheol;Moon, Seong-In;Kim, Young-Jin
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1186-1191
    • /
    • 2003
  • The 40% of wall criterion, which is generally used for the plugging of steam generator tubes, may be applied only to a single crack. In the previous study, a total of 9 failure models were introduced to estimate the local failure of the ligament between cracks and the optimum coalescence model of multiple collinear cracks was determined among these models. It is, however, known that parallel axial cracks are more frequently detected during an in-service inspection than collinear axial cracks. The objective of this study is to determine the plastic collapse model which can be applied to the steam generator tube containing two parallel axial through-wall cracks. Nine previously proposed local failure models were selected as the candidates. Subsequently interaction effects between two adjacent cracks were evaluated to screen them. Plastic collapse tests for the plate with two parallel through-wall cracks and finite element analyses were performed for the determination of the optimum plastic collapse model. By comparing the test results with the prediction results obtained from the candidate models, a plastic zone contact model was selected as an optimum model.

  • PDF

Novel De-interlacing Algorithm Using All Direction Edges Estimation Technique (전 방향 에지 예측 기법을 이용한 De-interlacing 알고리듬)

  • Ku, Su-Il;Lee, Se-Young;Kang, Kun-Hwa;Jeong, Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.9C
    • /
    • pp.725-733
    • /
    • 2008
  • This paper proposed a novel do-interlacing algorithm using all direction edges estimation technique. In the proposed algorithm. previously developed the DOI(Direction-Oriented Interpolation) algorithm was used as a basis. The do-interlacing method was divided into two main parts. First, we should estimate edge direction. Then, missing pixel: were interpolated along with the decided edge. In this paper, after estimating the edge through the DOI algorithm considering high angle edge direction, missing pixels were interpolated by using the median filter. Experimental results indicate that the proposed algorithm is superior to the conventional algorithms in terms of the objective and subjective criteria.

Damage Curves of the Fixed Ends Beam with the Rigid-Plastic Model (강-소성 모델을 이용한 양단 고정보의 손상곡선)

  • Kim, Seok Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.8 no.4
    • /
    • pp.239-246
    • /
    • 2004
  • The fixed ends beam is analyzed by the s d 0 f system with the rigid-plastic model. And the safety criteria of the fixed ends beam to the Impulsive loads are established with the peak-load ratio to the static collapse load and impulse ratio to the ideal impulse producing the critical displacement. It is shown that the impulse and the peak-load of the impulsive loads are the important factors for the damage of the structures. It is also shown that the damage curves with the peak-load and impulse ratio are useful method to estimate the damage of the structures due to the emphasis on the equivalent dynamic loads rather than the equivalent static loads in the process of deriving the curve.