• Title/Summary/Keyword: Error Mode

Search Result 1,219, Processing Time 0.03 seconds

Performance Estimation of Receiving Data Parket of TT&C System on the Pass Time of LEO Satellite (저궤도 위성의 통과시간에서 관제 시스템의 수신 데이터 패킷 성능 예측)

  • 장대익;김대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8A
    • /
    • pp.1149-1155
    • /
    • 1999
  • LEO(Low altitude Earth Orbit) Satellite systems have been utilized in the field of earth and scientific observation (cartography mission, ocean color monitoring, bioglogical coeanography, space environments observation by space physics sensor, and meteorological observation, atmospheric observation etc.), and the field of military (military communications and secret information, enemy reconnaissance etc.), and recently been developing in the field of mobile satellite commnication of GMPCS for commercial utilization. In Korea, KOMPSAT I satellite and ground system are been developing and planed to be lunched on October 1999 In this paper, the link budge of the TT&C system for LEO satellite is described and the relations between elevation angle and pass time of LEO satellite are calculated according to satellite moving. And the packet error rates of receiving data are derived three packet error rates(PER) of real-time(RT) mode, playback(PB) mode, and real-time and range tone(RT+RNG) mode are estimated according to pass time of satellite. The results of PER are the best at real-time and the worst at real-time mode and range mode at the all pass time of satellite. The average error free packet(EFP)s of real-time mode, playback mode, and real-time and range tone for the pass time of satellite are obtained as 99.999999%, 99.999912%, 99.995945% respectively. Therefore, transmission sequence of telemetry data are determined such as PER sequence according to pass time, namely, real-time, playback, and real-time and range mode.

  • PDF

A hybrid algorithm based on EEMD and EMD for multi-mode signal processing

  • Lin, Jeng-Wen
    • Structural Engineering and Mechanics
    • /
    • v.39 no.6
    • /
    • pp.813-831
    • /
    • 2011
  • This paper presents an efficient version of Hilbert-Huang transform for nonlinear non-stationary systems analyses. An ensemble empirical mode decomposition (EEMD) is introduced to alleviate the problem of mode mixing between intrinsic mode functions (IMFs) decomposed by EMD. Yet the problem has not been fully resolved when a signal of a similar scale resides in different IMF components. Instead of using a trial and error method to select the "best" outcome generated by EEMD, a hybrid algorithm based on EEMD and EMD is proposed for multi-mode signal processing. The developed approach comprises the steps from a bandpass filter design for regrouping modes of the IMFs obtained from EEMD, to the mode extraction using EMD, and to the assessment of each mode in the marginal spectrum. A simulated two-mode signal is tested to demonstrate the efficiency and robustness of the approach, showing average relative errors all equal to 1.46% for various noise levels added to the signal. The developed approach is also applied to a real bridge structure, showing more reliable results than the pure EMD. Discussions on the mode determination are offered to explain the connection between modegrouping form on the one hand, and mode-grouping performance on the other.

A Spatial Error Concealment Technique with Low Complexity for Intra-frame in the H.264 Standard (H.264 인트라 프레임을 위한 저복잡도(低複雜度) 공간적 에러은닉 기법)

  • Kim Dong-Hyung;Cho Sang-Hyup;Jeong Je-Chang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.5C
    • /
    • pp.503-511
    • /
    • 2006
  • H.264 adopts new coding tools such as intra-prediction, loop filter, etc. The adoption of these tools enables an H.264-coded bitstream to have more information compared with previous standards. In this paper we proposed an effective spatial error concealment method for H.264. Among the information included in an H.264-coded bitstream, we use intra-mode for recovering a damaged block. This is because prediction direction in intra-mode is highly correlated to the edge direction of a lost macroblock. We first estimate the edge direction using intra-modes of blocks adjacent to a lost macroblock, and classify the area in a damaged macroblock into the edge and the flat area. And then our method recovers pixel values in the edge area using edge-directed interpolation, and recovers pixel values in the flat area using weighted interpolation. Simulation results show the proposed method yields better video quality than conventional approaches by 0.35 to 5.48 dB.

A Study on Automatic Multi-Power Synchronous Transfer Switch using New DFT Comparator (새로운 DFT 비교기를 이용한 자동 다전원 동기절체 스위치에 관한 연구)

  • Kwak, A-Rim;Park, Seong-Mi;Son, Gyung-Jong;Park, Sung-Jun;Kim, Jong-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.3
    • /
    • pp.423-431
    • /
    • 2022
  • The UPS(Uninterruptible Power Supply) system operates in the battery charging mode when the grid is normal, and in the UPS mode, which is the battery discharge mode when a grid error occurs. Since the UPS must supply the same voltage as the grid to the load within 4 [ms] in case of a grid error, the switching time and power recovery time should be short when controlling the output voltage and current of the UPS, and the power failure detection time is also important. The power outage detection algorithm using DFT(Discrete Fourier Transform) proposed in this paper compares the grid voltage waveform with the voltage waveform including the 9th harmonic generated through DFT using Schmitt trigger to detect power outage faster than the existing power outage monitoring algorithm. There are advantages. Therefore, it is possible to supply instant and stable power when switching modes in the UPS system. The multi-power-applied UPS system proposed in this paper uses DFT, which is faster than the conventional blackout monitoring algorithm in detecting power failure, to provide stable power to the load in a shorter time than the existing power outage monitoring algorithm when a system error occurs. The detection method was applied. The changeover time of mode switching was set to less than 4 [ms], which is 1/4 of the system cycle, in accordance with KSC 4310 regulation, which was established by the Industrial Standards Council on the regulation of uninterruptible power supply. A 10 [kW] UPS system in which commercial voltage, vehicle generator, and auxiliary diesel generator can be connected to each of the proposed transfer devices was constructed and the feasibility was verified by conducting an experiment.

Accuracy Enhancement Technique in the Current-Attenuator Circuit (전류 감쇠 조정 회로에서의 정밀도 향상 기술)

  • Kim, Seong-Kweon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.8
    • /
    • pp.116-121
    • /
    • 2005
  • To realize the tap coefficient of a finite impulse response(FIR) filter or the twiddle factor of a fast Fourier transform(FFT) using a current-mode analog circuit, a high accurate current-attenuator circuit is needed This paper introduces an accuracy enhancement technique in the current-mode signal processing. First of all, the DC of set-current error in a conventional current-attenuator using a gate-ratioed orient mirror circuit is analyzed and then, the current-attenuator circuit with a negligibly small DC offset-current error is introduced. The circuit consists of N-output current mirrors connected in parallel with me another. The output current of the circuit is attenuated to 1/N of the input current. On the basis of the Kirchhoff current law, the current scale ratio is determined simply by the number of the current mirrors in the N-current mirrors connected in parallel. In the proposed current-attenuator circuit the scale accuracy is limited by the ac gain error of the current mirror. Considering that a current mirror has a negligibly small ac gain error, the attainable maximum scale accuracy is theoretically -80[dB] to the input current.

A constrained minimization-based scheme against susceptibility of drift angle identification to parameters estimation error from measurements of one floor

  • Kangqian Xu;Akira Mita;Dawei Li;Songtao Xue;Xianzhi Li
    • Smart Structures and Systems
    • /
    • v.33 no.2
    • /
    • pp.119-131
    • /
    • 2024
  • Drift angle is a significant index for diagnosing post-event structures. A common way to estimate this drift response is by using modal parameters identified under natural excitations. Although the modal parameters of shear structures cannot be identified accurately in the real environment, the identification error has little impact on the estimation when measurements from several floors are used. However, the estimation accuracy falls dramatically when there is only one accelerometer. This paper describes the susceptibility of single sensor identification to modelling error and simulations that preliminarily verified this characteristic. To make a robust evaluation from measurements of one floor of shear structures based on imprecisely identified parameters, a novel scheme is devised to approximately correct the mode shapes with respect to fictitious frequencies generated with a genetic algorithm; in particular, the scheme uses constrained minimization to take both the mathematical aspect and the realistic aspect of the mode shapes into account. The algorithm was validated by using a full-scale shear building. The differences between single-sensor and multiple-sensor estimations were analyzed. It was found that, as the number of accelerometers decreases, the error rises due to insufficient data and becomes very high when there is only one sensor. Moreover, when measurements for only one floor are available, the proposed method yields more precise and appropriate mode shapes, leading to a better estimation on the drift angle of the lower floors compared with a method designed for multiple sensors. As well, it is shown that the reduction in space complexity is offset by increasing the computation complexity.

Performance Analysis of Channel Error Probability using Markov Model for SCTP Protocol

  • Shinn, Byung-Cheol;Feng, Bai;Khongorzul, Dashdondov
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.2
    • /
    • pp.134-139
    • /
    • 2008
  • In this paper, we propose an analysis model for the performance of channel error probability in Stream Control Transmission Protocol (SCTP) using Markov model. In this model it is assumed that the compressor and decompressor work in Unidirectional Mode. And the average throughput of SCTP protocol is obtained by finding the throughputs of when the initial channel state is good or bad.

Performance Improvement of Voltage-mode Controlled Interleaved Buck Converters

  • Veerachary Mummadi
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.104-108
    • /
    • 2005
  • This paper presents the performance improvement of voltage-mode controlled interleaved synchronous buck converters. This is a voltage-mode controlled scheme, where the controllers do not need an external saw-tooth generator for PWM generation and the loop design is easier. The controller implementation requires only a single error amplifier and gives almost current mode control performance. The control scheme uses voltage feedback with two loops similar to current mode control: one for the slow outer loop and the other for the faster inner PWM control loop. To improve the performance of the converter system a coupled inductor is used. This coupled inductor reduces the magnetic size and also improves the converter's transient performance without increasing the steady-state current ripple. The effectiveness of the proposed control scheme is demonstrated through PSIM simulations.

VSC with three-segment nonlinear sliding mode for robot manipulator (로봇 매니퓰레이터를 위한 삼분 비선형 슬라이딩 모드를 가지는 가변구조 제어)

  • 최성훈;전경한;최봉열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.69-72
    • /
    • 1996
  • In this paper robust tracking control scheme using the new three-segment nonlinear sliding mode technique for nonlinear rigid robotic manipulator is developed. Sliding mode consists of three segments, the promotional acceleration segment, the constant velocity segment and the deceleration segment using terminal sliding mode. Strong robustness and fast error convergence can be obtained for rigid robotic manipulators with large uncertain dynamics by using the new three-segment nonlinear sliding mode technique together with a few useful structural properties of rigid robotic manipulator. The efficiency of the proposed method for the tracking has been demonstrated by simulations for two-link robot manipulator.

  • PDF

A 3.3-V Low-Power Compact Driver for Multi-Standard Physical Layer

  • Park, Joon-Young;Lee, Jin-Hee;Jeong, Deog-Kyoon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.7 no.1
    • /
    • pp.36-42
    • /
    • 2007
  • A low-power compact driver for multistandard physical layer is presented. The proposed driver achieves low power and small area through the voltage-mode driver with trans-impedance configuration and the novel hybrid driver,. In the voltage-mode driver, a trans-impedance configuration alleviates the problem of limited common-mode range of error amplifiers and the area and power overhead due to pre-amplifier. For a standard with extended output swing, only current sources are added in parallel with the voltage-mode driver, which is named a 'hybrid driver'. The hybrid architecture not only increases output swing but reduces overall driver area. The overall driver occupies $0.14mm^2$. Power consumptions under 3.3-V supply are 24.5 mW for the voltage-mode driver and 44.5 mW for the hybrid driver.