• Title/Summary/Keyword: Error Detector

Search Result 491, Processing Time 0.025 seconds

A Study on the Heterodyned Optical Phase Locked Loop (헤테로다인 광 위상 고정 루프 연구)

  • Yoo, Kang-Hee
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.10
    • /
    • pp.1163-1171
    • /
    • 2007
  • In this paper, the design techniques required to design heterodyned OPLL such as frequency-phase deference detector, loop filter and phase noise of semiconductor laser are presented. Through the experiments with the calculated parameters, we confirmed that the frequency-phase difference detector simply develops an error component that is proportional to the frequency-phase difference between heterodyned optical signals. The achieved frequency-phase locking range of the input laser diode frequency is around ${\pm}150MHz$. This paper describes the details of the designed as well as experimental results.

Development of Radiation Thermometer using InSb Photo-detector (인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구)

  • Hwang, Byeong-Oc;Lee, Won-Sik;Jhang, Kyung-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.7
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

The design of phase error detector based on delayed n-tap rising edge clock:It's DP-PLL system application (지연된 n-탭 상승 에지 클럭을 이용한 위상 오차 검출기의 설계와 DP-PLL에의 적용)

  • 박군종;구광일;윤정현;윤대희;차일환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.4
    • /
    • pp.1100-1112
    • /
    • 1998
  • In this paper, a novel method of minimizing the phase error is proposed. A DP-PLL system using this method is implemented and its performacnce is investigated, too. The DP-PLL system detects the phase error between reference clock and locally generated system clock. The phase difference is then reported as a PEV(Phase Error Variation), which is propoced from the delayted n-tap rising dege clock circuit with 5ns resolution in the phase detector. The algorithm is used to track the optimal DAC coefficients, which are adjusted from sample to sample in such a way as to minimize the PEV. The proposed method is found to have remarkable good potential for fast and accurate phase error tracking characteristic. The algorithm shows good performance to supress the low frequency jitter.-ending points, we design new basis functions based on the Legendre polynomial and then transform the error signals with them. When applied to synthetic images such as circles, ellipses and etc., the proposed method provides, in overall, outstanding results in respect to the transform coding gain compared with DCT and DST. And in the case when applied to natural images, the proposed method gives better image quality over DCT and comparable results with DST.

  • PDF

A Study on the Differential Detection of Multi-h Continuous Phase Modulation (Multi-h CPM의 차동 검파에 관한 연구)

  • 홍희식;한영열
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.3
    • /
    • pp.8-14
    • /
    • 1992
  • In this paper, the differential detection technique of multi-h CPM is introduced and described. We derived the sets of modulation index of multi-h phase codes adequate to the differential detection. The power spectra of multi-h signals with various sets of modulation index are presented and compared to those of MSK and QPSK. Error rate performances of the conventional detector and Viterbi algorithm detector of 2-h and 3-h CPM are evaluated and compared.

  • PDF

A Study on the Multi-Path Gain Adaptive MMSE Detector (다중경로 이득 적응형 MMSE 검출기에 관한 연구)

  • 유동관
    • Journal of the Korea Society of Computer and Information
    • /
    • v.9 no.2
    • /
    • pp.89-96
    • /
    • 2004
  • In this paper, an improved method is proposed by supplementing multi-path gain for detection. This method is proposed to complement the shortcomings of the conventional detection method which is used for multiuser detection in STBC(Space-Time Block Code) CDMA system. We analyzed the improved method in bit error probability viewpoint and compared the result with that of the conventional method. From this result, we showed that bit error probability of the improved method is superior to that of the conventional method when the parameters such as delay, number of user and SNR are increased.

  • PDF

Design of a Symbol Timing Recovery of QAM Using the Interpolation in AWGN channel (AWGN 채널에서 보간기를 이용한 QAM 방식에 대한 심볼동기회로 설계)

  • 박범대;오동진;김철성
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.77-80
    • /
    • 1999
  • This paper deals with a design of a symbol timing recovery circuit of QAM using the interpolation in AWGN channel. To reduce timing jitter and the amount of processing data, we employ MGA (Modified Gardner Algorithm) as a symbol timing error detector which is called NDA(Nondecision Directed Algorithm). We show the characteristics (S-curve and the variance) of timing error detector with the roll-off factor of a shaping filter, which are compared with GA. Also, we compare the BER curve of interpolation method with that of ideal case. The performance of the STR is shown to be close to that of ideal case. This result shows that this method can be useful to implement symbol timing recovery circuit for multi-level modulation.

  • PDF

Error Performance of Spatial-temporal Combining-based Spatial Multiplexing UWB Systems Using Transmit Antenna Selection

  • Kim, Sang-Choon
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.215-219
    • /
    • 2012
  • This paper applies transmit antenna selection algorithms to spatial-temporal combining-based spatial multiplexing (SM) ultra-wideband (UWB) systems. The employed criterion is based on the largest minimum output signal-to-noise ratio of the multiplexed streams. It is shown via simulations that the bit error rate (BER) performance of the SM UWB systems based on the two-dimensional Rake receiver is significantly improved by antenna diversity through transmit antenna selection on a log-normal multipath fading channel. When the transmit antenna diversity through antenna selection is exploited in the SM UWB systems, the BER performance of the spatial-temporal combining-based zero-forcing (ZF) receiver is also compared with that of the ZF detector followed by the Rake receiver.

Noninvasive Hematocrit Monitoring Based on Parameter-optimization of a LED Finger Probe

  • Yoon, Gil-Won;Jeon, Kye-Jin
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.3
    • /
    • pp.107-110
    • /
    • 2005
  • An optical method of measuring hematocrit noninvasively is presented. An LED Light with multiple wavelengths was irradiated on fingernail and transmitted light from the finger was measured to predict hematocrit. A finger probe contained an LED array and detector. Our previous experience showed that prediction accuracy was sensitive to reliability of the finger probe hardware and we optimized the finger probe parameters such as the internal color, detector area and the emission area of a light source based on Design of Experiment. Using the optimized finger probe, we developed a hematocrit monitoring system and tested with 549 persons. For the calibration model with 368 persons, a regression coefficient of 0.74 and a standard deviation of 3.67 and the mean percent error of $8\%$ were obtained. Hematocrits for 181 persons were predicted. We achieved a mean percent error of $8.2\%$ where the regression coefficient was 0.68 and the standard deviation was 3.69.

Design of a Timing Recovery Loop for Inmarsat Mini-m System Downlink Receiver (Inmarsat Mini-m 시스템의 하향 링크 수신기를 위한 Timing Recovery 루프 설계)

  • Cho, Byung-Chang;Han, Jung-Su;Choi, Hyung-Jin
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.6A
    • /
    • pp.685-692
    • /
    • 2008
  • In this paper, we propose a timing recovery loop for Inmarsat mini-m system downlink receiver. Inmarsat mini-m system requires a timing recovery loop which is robust in frequency offset and has fast acquisition because Inmarsat mini-m system specification requires frequency tolerance is required of ${\pm}924$ Hz (signal bandwidth: 2.4 kHz) and acquisition time of UW (Unique Word) signal duration (15ms).Therefore, we propose a timing recovery loop which is suitable for Inmarsat mini-m system. The proposed timing recovery loop adopted noncoherent UW detector and differential ELD which applied differential UW signal for stability and fast acquisition in frequency offset environment. Simulation results show that the proposed timing recovery loop has stable operation and fast acquisition in frequency offset environment for the system.