• Title/Summary/Keyword: Error Detector

Search Result 491, Processing Time 0.031 seconds

A Study on the Implementation of the 2-Dimension Magnetic Fluxgate Sensor (2차원 Magnetic Fluxgate센서의 구현에 관한 연구)

  • Park, Yong-Woo;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • We have presented a 2-dimensional fluxgate sensor with ferrite core, excitation, and pick-up coil. This fluxgate sensor system consists of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through the excitation coil of 80 turns. The second harmonic output of pick-up coil(x and y axis: 100 turns) is measured by FFT spectrum analyzer. This result is compared with output of PSD(phase sensitive detector) unit for detecting the second harmonic component. The measured maximum sensitivity is about 1580 V/T at driving frequency of 1.5 kHz and excitation current of 2 App. The nonlinearity of this system is measured about 2.3%(PSD) and about 1%(second harmonics of the pick-up). The angle error of the system is ${\pm}2$ %/FS.

The Estimation of Link Travel Time for the Namsan Tunnel #1 using Vehicle Detectors (지점검지체계를 이용한 남산1호터널 구간통행시간 추정)

  • Hong Eunjoo;Kim Youngchan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • As Advanced Traveler Information System(ATIS) is the kernel of the Intelligent Transportation System, it is very important how to manage data from traffic information collectors on a road and have at borough grip of the travel time's change quickly and exactly for doing its part. Link travel time can be obtained by two method. One is measured by area detection systems and the other is estimated by point detection systems. Measured travel time by area detection systems has the limitation for real time information because it Is calculated by the probe which has already passed through the link. Estimated travel time by point detection systems is calculated by the data on the same time of each. section, this is, it use the characteristic of the various cars of each section to estimate travel time. For this reason, it has the difference with real travel time. In this study, Artificial Neural Networks is used for estimating link travel time concerned about the relationship with vehicle detector data and link travel time. The method of estimating link travel time are classified according to the kind of input data and the Absolute value of error between the estimated and the real are distributed within 5$\~$15minute over 90 percent with the result of testing the method using the vehicle detector data and AVI data of Namsan Tunnel $\#$1. It also reduces Time lag of the information offered time and draws late delay generation and dissolution.

  • PDF

Analysis of Performance of Digital Retrodirective Antenna Technology in High-Speed Rail (고속 철도 환경에서의 디지털 역지향성 안테나 기술 성능 분석)

  • Bok, Junyeong;Lee, Seung Hwan;Shin, Dong Jin;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.11
    • /
    • pp.1264-1271
    • /
    • 2012
  • Fast tracking is important for high-speed data transmission in high-speed mobile environment such as high speed rail and vehicular. Digital retrodirective array antenna is possible to do automatically beam tracking because it can control the phase information of the output signal toward opposite direction to input signal without no a priori knowledge of the arrival direction. Also, Digital retrodirective array antennas has merit that it is easy to upgrade and modify compare with analogue retrodirective array antennas. In this paper, we analyze the BER performance of digital retrodirective array antenna under AWGN environment and multipath signal. Simulation results show correct phase estimation and conjugation of retrodirective array antenna by using phase detector block. Also, phase conjugation technique has better BER performance about 1 dB at source than that of without phase conjugation when phase lag is $15^{\circ}$ in AWGN environment. This paper also discusses effect of the presence of multipath signal. Phase and amplitude error about direction of direct signal occurs when retrodirective array system is affected by interference and multipath signal in the presence of multipath signal.

A study on traffic signal control at signalized intersections in VANETs (VANETs 환경에서 단일 교차로의 교통신호 제어방법에 관한 연구)

  • Chang, Hyeong-Jun;Park, Gwi-Tae
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.6
    • /
    • pp.108-117
    • /
    • 2011
  • Seoul metropolitan government has been operating traffic signal control system with the name of COSMOS since 2001. COSMOS uses the degrees of saturation and congestion which are calculated by installing loop detectors. At present, inductive loop detector is generally used for detecting vehicles but it is inconvenient and costly for maintenance since it is buried on the road. In addition, the estimated queue length might be influenced in case of error occurred in measuring speed, because it only uses the speed of vehicles passing by the detector. A traffic signal control algorithm which enables smooth traffic flow at intersection is proposed. The proposed algorithm assigns vehicles to the group of each lane and calculates traffic volume and congestion degree using traffic information of each group using VANETs(Vehicular Ad-hoc Networks) inter-vehicle communication. It does not demand additional devices installation such as cameras, sensors or image processing units. In this paper, the algorithm we suggest is verified for AJWT(Average Junction Waiting Time) and TQL(Total Queue Length) under single intersection model based on GLD(Green Light District) Simulator. And the result is better than Random control method and Best first control method. In case real-time control method with VANETs is generalized, this research that suggests the technology of traffic control in signalized intersections using wireless communication will be highly useful.

Evaluation of Angle Dependence on Positional Radioisotope Source Detector using Monte Carlo Simulation in NDT (몬테카를로 시뮬레이션을 이용한 방사선원 위치 검출기의 각도의존성 연구)

  • Han, Moojae;Heo, Seunguk;Shin, Yohan;Jung, Jaehoon;Kim, Kyotae;Heo, Yeji;Lee, Deukhee;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.141-146
    • /
    • 2019
  • Radiation sources used in the field of industrial non-destructive pose a risk of exposure due to ageing equipment and operator carelessness. Thus, the need for a safety management system to trace the location of the source is being added. In this study, Monte Carlo Simulation was performed to analyse the angle dependence of the unit-cell comprising the line-array dosimeter for tracking the location of radiation sources. As a result, the margin of error for the top 10% of each slope was 5.90% at $0^{\circ}$, 8.08% at $30^{\circ}$, and 20.90% at $60^{\circ}$. The ratio of the total absorbed dose was 83.77% at $30^{\circ}$ and 53.36% at $60^{\circ}$ based on $0^{\circ}$(100%) and showed a tendency to decrease with increasing slope. For all gradients, the maximum number was shown at $30^{\circ}$ No. 9 pixels, and for No. 10, there was a tendency to drop 7.24 percent. This study has shown a large amount of angle dependence, and it is estimated that the proper distance between the source and line-array dosimeters should be maintained at a distance of not less than 1 cm to reduce them.

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

Analysis of Parallel Interference Cancellation with the Improved Initial Stage (초기단을 개선시킨 병렬형 간섭 제거기에 관한 분석)

  • 염순진;정재윤;박용완
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.464-470
    • /
    • 2000
  • In this paper, we introduce a modified interference cancellation scheme to overcome MAI(Multiple Access Interference) in DS-CDMA. Among ICs(Interference Cancellers), PIC(Parallel Interference Canceller) requires the more stages to have the better BER(Bit Error Rate), and SIC(Successive Interference Canceller) faces the problems of power reordering and large delays. To resolve the problems of them, we propose a modified interference cancellation scheme combining SIC and PIC. The proposed interference canceller has improved the performance through the total received signal applied sorting method is fed into the initial stage. Its structure extracts the good characteristics because of the input signal removed MAI in the initial stage. The characteristics of the proposed system are as follows (1) smaller delay, and the strongest user signal is also reduced to MAI(unlike SIC), (2) it has the good BER performance only using fewer stages (unlike PIC).

  • PDF

An Efficient Soft-Output MIMO Signal Detection Method Based on Multiple Channel Ordering Technique and Its VLSI Implementation (다중 채널 순서화 기술 기반 효율적인 Soft-Output MIMO 신호검출 기법과 VLSI 구현)

  • Im, Tae-Ho;Yu, Sung-Wook;Kim, Jae-Kwon;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12C
    • /
    • pp.1044-1051
    • /
    • 2010
  • In this paper, we propose an efficient soft-output signal detection method for spatially multiplexed multiple input multiple output (MIMO) systems. The proposed method is based on the ordered successive interference cancellation (OSIC) algorithm, but it significantly improves the performance of the original OSIC algorithm by solving the error propagation problem. The proposed method combines this enhanced OSIC (ESIC) algorithm with a multiple ordering technique in a very efficient way. As a result, the log likelihood ratio (LLR) values can be computed by using a very small set of candidate symbol vectors. The proposed method has been implemented with a $0.13{\mu}m$ CMOS technology for a $4{\times}4$ 16-QAM MIMO system. The simulation and implementation results show that the proposed detector provides a very good solution in terms of performance and hardware complexity.

Design and Implementation of Optical Receiving Bipolar ICs for Optical Links

  • Nam Sang Yep;Ohm Woo Young;Lee Won Seok;Yi Sang Yeou1
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.717-722
    • /
    • 2004
  • A design was done, and all characteristic of photodetectr of the web pattern type which a standard process of the Bipolar which Si PIN structure was used in this paper, and was used for the current amplifier design was used, and high-speed, was used as receiving optcal area of high altitude, and the module which had a low dark current characteristic was implemented with one chip with a base. Important area decreases an area of Ie at the time of this in order to consider an electrical characteristic and economy than the existing receiving IC, and performance of a product and confidence are got done in incense. First of all, the receiving IC which a spec, pattern of a wafer to he satisfied with the following electrical optical characteristic that produced receiving IC of 5V and structure are determined, and did one-chip is made. On the other hand, the time when AR layer of double is $Si_{3}N_{4}/SiO_{2}=1500/1800$ has an optical reflectivity of less than $10{\%}$ on an incidence optical wavelength of 660 ,and, in case of photo detector which reverse voltage made with 1.8V runs in 1.65V, an error about a change of thickness is very the thickness that can be improved surely. And, as for the optical current characteristic, about 5 times increases had the optical current with 274nA in 55nA when Pc was -27dBm. A BJT process is used, and receiving IC running electricity suitable for low voltage and an optical characteristic in minimum 1.8V with a base with two phases is made with one chip. IC of low voltage operates in 1.8V and 3.0V at the same time, and optical link receiving IC is going to be implemented

  • PDF

Visible Light Wireless Communication Link Using LEDs (LED를 이용한 가시광 무선 통신 링크)

  • Son, Yong-Hwan;An, Sung-Chan;Kim, Hyun-Seung;Won, Yong-Yuk;Han, Sang-Kook
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.70-74
    • /
    • 2009
  • In this paper, We propose the visible light communication(VLC) link based on white light emitting diode (LED) and Photo detector(PD). The proposed architecture is demonstrated experimentally and its performance is verified through the experimental results of quality-factor(Q-factor) and eye pattern of 10Mb/s PRBS signal. The ambient light effect from a typical type fluorescent lamp source was also analyzed. when the distance between the LED and the PD is about 1m, error free wireless transmission of the LED was achieved up to 10Mb/s data rate. Under the condition with ambient light, low BER, data transmission of the VLC link is achieved up to 5Mb/s data rate at 1m. Also, when the PD is placed away from the center, low BER data transmission of the VLC link is achieved up to 1Mb/s at 10cm and 10Mb/s at 5cm.

  • PDF