• 제목/요약/키워드: Equivalent thickness

검색결과 603건 처리시간 0.022초

Equivalent-circuit Analysis of ITO/Alq3/Al Organic Light-emitting Diode

  • Chung, Dong-Hoe;Kim, Tae-Wan
    • Transactions on Electrical and Electronic Materials
    • /
    • 제8권3호
    • /
    • pp.131-134
    • /
    • 2007
  • An $ITO/Alq_3/Al$ structure was used to study complex impedance of $Alq_3$ based organic light-emitting diodes. Equivalent circuit was analyzed in a device structure of $ITO/Alq_3/Al$ with a thickness layer of $Alq_3$ of 100 nm. The obtained impedance was able to be fitted using equivalent circuit model of parallel combination of resistance $R_p$ and capacitance $C_p$ with a small series resistance of $R_s$.

성덕대왕신종의 등가 종과 맥놀이 주기 조절 (An Equivalent Bell and Beat Period Control in the Sacred Bell of the Great King Seongdeok)

  • 이중혁,;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.472-475
    • /
    • 2013
  • This study proposes an equivalent bell model for the Sacred Bell of the Great King Seongdeok An equivalent bell model bas the modal property of the real bell and it consists of an axi-symmetric bell body and a point mass, The bell model is constructed by the finite element analysis based upon the theory of a revolutionary shell. Using the equivalent bell model. the beat period can be controlled by decreasing the thickness of local area. This study aims at showing a beat period control method for a large bell having the similar size to the Sacred Bell of the Great King Seongdeok.

  • PDF

Theoretical analysis of stress-strain behavior of multi-layer RC beams under flexure

  • Ertekin Oztekin
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.505-515
    • /
    • 2024
  • In this study, obtaining theoretical stress-strain curves and determining the parameters defining the equivalent rectangular stress block were aimed for 3 and 4-layered rectangular Reinforced Concrete (RC) cross-sections subjected to flexure. For these aims, the analytical stress-strain model proposed by Hognestad was chosen for the concrete grades (20 MPa≤fck≤60 MPa) used in this study. The tensile strength of the concrete was neglected and the thickness of the concrete layers in the compression zone of the concrete cross-section was taken as equal. In addition, while concrete strength was kept constant within each layer, concrete strengths belonging to separate layers were increased from the neutral axis towards the outer face of the compression zone of the concrete cross-section. After the equivalent rectangular stress block parameters were determined by numerical iterations, variations of these parameters depending on concrete strength in layers and layer numbers were obtained. Finally, some analytical equations have been proposed to predict the equivalent stress block parameters for the 3 and 4-layered RC cross-sections and validities of these proposed equations were shown by different metrics in this study.

Leachability of Zinc Borate-Modified Oriented Strandboard (OSB)

  • Lee, Sun-Young;Wu, Qinglin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제35권5호
    • /
    • pp.46-57
    • /
    • 2007
  • The leachability of boron in zinc borate (ZB)-modified oriented strandboard (OSB) from southern wood species was investigated in this study. The leaching experiments were conducted by exposing edge-sealed OSB samples under running water at $31^{\circ}C$ for 8, 24, 72, and 216 h. The results from leached samples were compared with those from the unleached controls. Boron leaching of the modified OSB occurred upon the initial water exposure, and the leaching rate decreased as the leaching time increased. Initial boric acid equivalent (BAE) level, wood species, and sample thickness swelling significantly influenced the leachability. There was no consistent effect of polyethylene glycol (PEG) on zinc borate leaching. The glue-line washing within OSB due to thickness swelling of the test samples under water and decomposition of the borate to form water-soluble boric acid were thought to be two possible causes for the observed leaching. The relationship between assayed BAE and leaching time followed a decaying exponential function for zinc borate treated OSB. From the boron/zinc ratio after each leaching period, boron element in ZB was more or less leachable. The material constant of the regression models allowed comparing the leachability of the modified OSB for various wood species. An unified leaching method for treated wood composite materials is needed.

6H-SiC 위에 형성한 에피택시 AIN 박막 구조에 대한 전기적 특성의 평가온도 의존성 (Temperature Dependence on Electrical Characterization of Epitaxially Grown AIN film on 6H-SiC Structures)

  • 김용성;김광호
    • 한국전기전자재료학회논문지
    • /
    • 제19권1호
    • /
    • pp.18-22
    • /
    • 2006
  • Epitaxial aluminum nitride films on 6H-SiC (0001) were fabricated using reactive RF magnetron sputtering and post-deposition rapid thermal annealing. The electrical properties of AIN films depending on film thickness and measurement temperature have been observed. Full width at half maximum of AIN (0002) was $0.1204^{\circ}$ (about 430 arcsec) X-ray rocking curve results. The equivalent oxide thickness (EOT) of AIN film was estimated as about 10 nm and the leakage current density was within the order of $10^{-8} 4/cm^2$. The dielectric constant of AIN film estimated from the accumulation region of C-V curve measured at $300^{\circ}C$ was 8.3. The dynamic dielectric constant was obtained as 5.1 from J vs. 1/T plots at the temperature ranging from R.T. to $300^{\circ}C$ From above, estimation temperature dependance of the electrical properties of Al/AIN/SiC MIS devices was affirmed and useful data compilation for the reliabilities of SiC MIS is expected.

욕조의 보온성능연구 (A Performance Equation of Bath Tubs)

  • 이병호;서정일
    • 대한설비공학회지:설비저널
    • /
    • 제10권1호
    • /
    • pp.1-11
    • /
    • 1981
  • In this paper, a new performance equation of bath tubs has been derived, which is very characteristically illuminating and in good agreement with experiments : $$T=T_{\infty}+(T_0-T_{\infty})e-\frac{k(A'_f+A_0)}{Mc_{P{\Delta}x}t$$, where $T_{\infty}$ is the temperature of the bathroom, $T_0$ that of the bathwater at t=0, k the overall heat conductivity of the tub- wall, $A'_f$ the equivalent surface area to the wall, $A_0$ the submerged area of the tub-wall, M mass of the bath-water, $C_p$ the specific heat of the bathwater and ${\Delta}x$ the thickness of the tub-wall. Here the equivalent-free surface area is written as $$A'_f=mA_f,\;m=const.(1-{\phi})^{0.88}$$ : where m is a numerical factor which is determined by a simple experiment and some calculation, {\phi}$ the relative humidity and $A_f$ the real free-surface area. From this study, it has been clarified that cooling of bath-water is mainly due to mass-transfer through evaporation from the free surface and conductive heat loss through the tub-wall is minor, which rather gaily mock at common sense. The effect of keeping bathwater warn by increase of the tub-wall thickness is also analyzed by a new idea of the thickness gain factor.

  • PDF

A new four-unknown equivalent single layer refined plate model for buckling analysis of functionally graded rectangular plates

  • Ibrahim Klouche Djedid;Sihame Ait Yahia;Kada Draiche;Emrah Madenci;Kouider Halim Benrahou;Abdelouahed Tounsi
    • Structural Engineering and Mechanics
    • /
    • 제90권5호
    • /
    • pp.517-530
    • /
    • 2024
  • This paper presents a new four-unknown equivalent single layer (ESL) refined plate theory for the buckling analysis of functionally graded (FG) rectangular plates with all simply supported edges and subjected to in-plane mechanical loading conditions. The present model accounts for a parabolic variation of transverse shear stress over the thickness, and accommodates correctly the zero shear stress conditions on the top and bottom surfaces of the plate. The material properties are supposed to vary smoothly in the thickness direction through the rules of mixture named power-law gradation. The governing equilibrium equations are formulated based on the total potential energy principle and solved for simply supported boundary conditions by implementing the Navier's method. A numerical result on elastic buckling using the current theory was computed and compared with those published in the literature to examine the accuracy of the proposed analytical solution. The effects of changing power-law exponent, aspect ratio, thickness ratio and modulus ratio on the critical buckling load of FG plates under different in-plane loading conditions are investigated in detail. Moreover, it was found that the geometric parameters and power-law exponent play significant influences on the buckling behavior of the FG plates.

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

The Thickness Dependence of Edge Effect in Thin Insulating Films

  • Song Jeong-Myen;Moon Byung-Moo;Sung Yung-Kwon
    • Transactions on Electrical and Electronic Materials
    • /
    • 제4권4호
    • /
    • pp.13-17
    • /
    • 2003
  • This paper deals with the edge effect in thin insulating films, focusing on their dependence on film thickness. The finding is that the electric field is lowered at the edge as the film thickness is reduced, which, in turn, is closely related to dielectric breakdown voltage. In order to analyze this phenomenon, a simple capacitor model is introduced with which dependence of dielectric breakdown voltage around the electrode edge on the film thickness is explained. Due to analytical difficulty to get the expression of electrical field strength at the edge, an equivalent circuit approach is used to find the voltage expression first and then the electric field expression using it. The relation gets to an agreement with the experimental findings shown in the paper. This outcome may be extended to solve similar problems in multi-layer insulating films.

시편 두께에 따른 알루미나 세라믹스의 이축 파괴 거동 (Biaxial Fracture Behavior of Alumina Ceramics ; Thickness Effect on Ball-on-3-ball Test)

  • 이홍림;박성은;이중현
    • 한국세라믹학회지
    • /
    • 제36권7호
    • /
    • pp.711-717
    • /
    • 1999
  • Biaxial fracture behavior of alumina specimens with the diameter of 20mm and four kinds of thickness of 1.9, 2.3, 2.6 and 2.8mm was studied by the ball-on-3-ball test and the fracture results were analyzed by he analysis of variance (ANOCA), The strength measured with the down speed prescribed in ASTM showed that the measured strength was not dependent on the thickness of the specimens. Equivalent radius and crack-braching number were observed to increase lineraly with the thickness of the specimens. The jog direction was observed to study the effect of grinding direction on surface flaws. It is though that the surface finishing with #600 grit diamond wheel did not affect the surface flaws of the specimens.

  • PDF