• 제목/요약/키워드: Equivalent sound level(Leq)

검색결과 10건 처리시간 0.03초

국내 철도 차량의 음향발생 특성에 대한 비교 연구 (Sound Power Evaluation of Various Domestic Railroad Vehicles)

  • 김정태;조성호
    • 한국철도학회논문집
    • /
    • 제2권1호
    • /
    • pp.28-37
    • /
    • 1999
  • Many residential areas are situated near to railroad tracks so that a railroad noise has been one of the major environmental issues. In this paper two important aspects have been investigated in order to properly evaluate the railroad vehicle noise : sound power levels for different types and sound propagation characteristics of the railroad vehicles. For noise source characteristics of railroad vehicles, sound power values for various types of trains that are in active service have been measured. In this paper, domestic railroad vehicles are measured and compared with high speed train(TGV). Based on sound power information of railway vehicles, prediction on the sound pressure level and equivalent noise level near to railway areas have been evaluated.

  • PDF

Leq, Lr, TNI 평가법에 의한 부산시 주요 상가변의 소음도 분석 (An Analysis on Traffic Noise at Pusan Shopping Districts by Leq, Lr, TNI Ratings)

  • 한돈희
    • 한국환경보건학회지
    • /
    • 제16권1호
    • /
    • pp.9-19
    • /
    • 1990
  • To evaluate the degree of traffic noise at the main shopping districts, 30 sites, in Pusan and produce the basic data of traffic noise counterplan, this research was conducted. Noise rating methods utilized were Leq(equivalent continuous sound level), Lr (rating sound level) and TNI (traffic noise index). As the results, all sites passed beyond Korean Environmental Noise Standard 70 dB(A) in Leq and 46.7% sites fell under 'widespread complaints'step, 40.0% 'threat of community' action'step, 13.3% 'vigorous community action'step by Lr ratings, and 30.0% sites were over acceptable TNI criteria of 74. Therefore, traffic noise at Pusan shopping districts was very severe.

  • PDF

Weibull분포를 이용한 도로교통소음의 예측에 관한 연구 (A Method to Predict Road Traffic Noise Using the Weibull Distribution)

  • 김갑수
    • 대한교통학회지
    • /
    • 제5권2호
    • /
    • pp.73-80
    • /
    • 1987
  • Various procedures for evaluation of traffic noise annoyance have been proposed. However, most of the studies of this type are restricted for improving traffic flow. In this paper, a method to predict the road traffic noise is proposed in terms of equivalent continuous A-Weighted sound pressure level (Leq), based on a probability model. First, distribution of the road traffic noise level are investigated. second, the weibull distribution parameters are estimated by using the quantification theory. Finally, a prediction model of the road traffic noise is proposed based on the weibull distribution model The predicted values of the Leq are closely matched the measured data.

  • PDF

소음측정방법에 따른 평가소음도 비교 (A Comparison of Noise Level by Noise Measuring Methods)

  • 심철구;노재훈;박정균
    • 한국산업보건학회지
    • /
    • 제5권2호
    • /
    • pp.128-136
    • /
    • 1995
  • The purpose of this study is to evaluate the difference of noise level according to noise measuring methods in the noisy working environments. Sound pressure level(SPL), equivalence sound level(Leq) and personal noise exposure dose(Dose) in the fifty-nine unit workplaces of the twenty-eight industries were measured and relating factors which were affected noise level were investigated. The results were as follows ; 1. The noise levels were $88.70{\pm}5.68dB(A)$ by SPL, $89.07{\pm}5.41dB(A)$ by Leq and $89.07{\pm}5.69$ by Dose. The differences of noise levels by three measuring methods were statistically significant(P<0.001) by repeated measure ANOV A. 2. Comparing with noise levels by general classes of noise exposure, noise levels of continuous noise were $89.14{\pm}5.19dB(A)$ by SPL, $89.45{\pm}4.65dB(A)$ by Leq and $90.04{\pm}5.09$ by Dose. Noise levels of intermittent noise were $87.90{\pm}6.52dB(A)$ by SPL, $88.40{\pm}6.63dB(A)$ by Leq and $90.10{\pm}6.80$ by Dose. The differences noise level of noise measuring methods by general classese of noise exposure were statistically not significant by repeated measure ANOV A. 3. Interaction between general classese of noise exposure and noise measuring methods for noise level was not statistically significant by repeated measure ANOVA. And the noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001) 4. Comparing with noise levels by unit workplace size, noise levels of large unit workplace were $90.73{\pm}5.87dB(A)$ by SPL, $91.32{\pm}5.50dB(A)$ by Leq and $91.82{\pm}6.06$ by Dose and noise levels of middle unit workplace were $88.31{\pm}5.26dB(A)$ by SPL, $88.41{\pm}4.83dB(A)$ by Leq and $89.69{\pm}5.05$ by Dose. And noise levels of small unit workplace were $94.89{\pm}4.10dB(A)$ by SPL, $85.35{\pm}4.11dB(A)$ by Leq and $86.87{\pm}4.98$ by Dose. The noise level differences of noise measuring methods by unit workplace size were statistically significant by repeated measure ANOV A(P<.05). 5. The noise level by noise measuring methods were statistically significant by repeated measure ANOV A(P<.001). But Interaction between workplace size and noise level measuring methods for noise level was not statistically significant by repeated measure ANOVA. According to the above results, there was a difference of the noise level among the three measuring methods. Therefore we must use the personal noise exposure dose using by noise dose meter, possible, to prvent occupational hearing loss in noisy working environment.

  • PDF

광주천변의 사운드스케이프 현황 (Soundscape for Gwang-Ju Riverside)

  • 송혁;박현구;송민정;이태강;김항
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.603-606
    • /
    • 2005
  • This study is to make good acoustic environment around Gwang-ju riverside and performed survey and measurement of soundscape. The survey was focused on the types of sound producing. The results of measurement and analysis are as follows: 1) The types of sound at reverside were twenty and the Leq(equivalent noise level) was ranging from 50 dB(A) to 76 dB(A). The dominant sound was road traffic noise. 2) In the upperstream and the downstream, the sound of wind, bird and water was observed. 3) In the inner city, the water sound was produced by the difference of the height of the weir to mask the road traffic noise.

  • PDF

대학주변 원룸형 다가구주택의 실내소음수준 실태 (Present Condition of Indoor Noise Level in One-Room Type Multi-Family Housings around Campus)

  • 최윤정
    • 한국실내디자인학회논문집
    • /
    • 제14권3호
    • /
    • pp.191-198
    • /
    • 2005
  • The present study is a preliminary research improving the dwelling quality of one-room type multi-family housings around the university campus. The purpose of the study is to investigate the present condition of Indoor noise level using · residents' responses and field measurements. The respondents are 104 residents living in one-room type multi-family housings. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the $26th\~28th$ of November 2002. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of indoor noise. 2) They answer 'living equipment foise' and 'water hammer' as major types of indoor noise of house unit. 3) Outdoor noise levels, basic factor of noise environment in 6 subject buildings were distributed $52.8\~65.3dB(A)Leq_{5min}$ and were inappropriate to the standard for environmental noise, $55 dB(A)Leq_{5min}$. 4) Indoor noise levels of subject house units were measured as $27.5\~63.5dB(A)Leq_{5min}$, the average of each house unit except one house unit was higher than the level feeling as noise, 40dB(A). 5) It was found that the differences of indoor noise levels between subject house units were caused by 'residents' living noise', 'living equipment noise', 'water hammer', and 'walking and talking noise in stairs and corridors'. 6) Therefore, it is required to plan for improving the quality of noise environment in one-room type multi-family housing around the campus. For example, soundproof construction (including double window with pair glass and balcony), outdoor garden with trees and water for increasing natural sound, interior materials with sound absorbing power to absorb living noise, soundproof pipe or double surface pipe for decreasing 'water hammer', and noiseproof floors, etc. are required.

음질을 고려한 환경소음 평가 인자의 기여도분석에 관한 연구 (A Study of the Sound Quality Characteristics for Environmental Noise Assessments Parameters)

  • 조경숙;조연;황대선;허덕재
    • 한국음향학회지
    • /
    • 제25권3호
    • /
    • pp.129-136
    • /
    • 2006
  • 소음에 대한 인간의 심리적 인지는 소음의 여러 가지 물리적 요인에 의하여 영향을 받는다. 그러나 현재의 환경소음 평가는 A 가중치 등가 소음 수준을 기준으로 평가되고 있으며 인간의 다양한 감성적 요인을 반영하지 못하고 있다. 따라서 본 연구에서는 환경소음 평가를 위하여 환경소음원 43개에 대하여 주관평가와 통계적 분석방법을 사용하여 인간의 감성에 영향을 주는 음질인자 (Sound quality factor)를 분석하였다. 분석방법은 먼저 다양한 환경소음원에 대한 음질물리량 (Sound quality metrics)을 분석하여 음원을 분류하였으며 분류된 음원의 주된 음질 물리량을 고찰하였다. 그리고 쌍대비교법 (Paired comparisons method)과 어의분별척도법 (Semantic differential method)을 사용하여 주관 평가를 실시하고 음질의 요인을 분석하였으며 물리량과의 관계를 규명하였다. 마지막으로 요인에 대한 물리량의 기여도를 분석함으로써 환경소음의 감성적 인지에 대한 기초 물리량을 설정하였다.

대학교 학생식당의 소음저감을 위한 실내소음 실태분석 (Analysis on Indoor Noise Condition of Cafeteria in University Campus)

  • 최윤정;이선아;김혜경
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2007년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2007
  • This research is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to investigate the present condition of physical level, type, and source of indoor noise by comparison with a restaurant near campus. Methods were field survey with measurement on equivalent and instant noise level and observation on noise type, and questionnaire survey to 60 students users. Surveys were carried out in the 8th and the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$(average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$(average 71.2) dB(A), but noise levels of the restaurant were $61.6{\sim}70.4$(average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$(average 64.9) dB(A). 2) The users's responses on major noise type were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'taking noise' in cafeteria, but 'taking noise' and 'background music' in restaurant. 3) It was found that the differences of indoor noise condition between with 2 subjects were caused by finishing materials, kitchen division type, and furniture type.

  • PDF

대학교 학생식당의 실내소음 실태 및 원인 분석 사례연구 (A Case Study for Analysis on Present Condition and Cause of Indoor Noise in University Cafeteria)

  • 최윤정;이선아;김혜경
    • 한국주거학회논문집
    • /
    • 제18권5호
    • /
    • pp.85-91
    • /
    • 2007
  • This is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to find out the present condition of physical level, type, and cause of indoor noise of cafeteria in university campus by comparison with a restaurant near campus. Research methods were field survey and questionnaire survey. Field survey was consisted of measurement on equivalent and instant noise level and observation on noise type. Respondents of questionnaire survey were 60 students using subject cafeteria or restaurant. Surveys were carried out in the 8th and in the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$ (average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$ (average 71.2) dB (A), exceeded the indoor noise recommended value of ASHRAE (American Society of Heating, Refrigerating and Air Conditioning Engineers). But noise levels of the restaurant were $61.6{\sim}70.4$ (average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$ (average 64.9) dB(A). 2) The users's responses on major noise type in the cafeteria were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'talcing noise', but 'taking noise' and 'background music' in the restaurant. 3) It was found that indoor noise level of the cafeteria was caused by sound reflection of finishing materials, noise diffusion by open type kitchen, and dragging noise of movable furniture.

아파트의 내부 생활소음레벨 및 소음종류 실태 (Present Condition on Noise Level and Types Including Residents' Living Noise in Apartment Units)

  • 최윤정
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.427-430
    • /
    • 2008
  • The present study is a preliminary research improving the dwelling quality of apartment house as a kind of multi-family housing. The purpose of the study is to find out the present condition on noise level and types including residents' living noise in apartment units. The method was field survey consisted of field measurements on equivalent noise level, observation on noise type, and interview on residents' responses. The results are as follows. 1) Averages of indoor noise levels of subject houses were measured as $43.9{\sim}62.2\;dB(A)_{Leq5min}$, the average of each house except one was higher than the permissible level, 45 dB(A). 2) The noise types observed were mostly residents' living noise and classified as 'water hammer', 'living equipment noise', 'noise by family', 'hood noise', and 'kitchen noise' in own unit, 'walking and talking noise in stairs and corridors', 'noise by neighborhood house', 'noise by the upper story' in building, and outdoor noise. 3) The residents show slightly non-positive responses at 'noise by the upper story', 'noise by neighborhood house', 'water hammer', and 'noise by family'. Therefore, it is required to plan for preventing deterioration of the sound environment quality by residents' living noise in own unit as well as by neighborhood houses.

  • PDF