Analysis on Indoor Noise Condition of Cafeteria in University Campus

대학교 학생식당의 소음저감을 위한 실내소음 실태분석

  • 최윤정 (충북대학교 주거환경.소비자학과) ;
  • 이선아 (청주 서원중학교) ;
  • 김혜경 (충북대학교 주거환경.소비자학과)
  • Published : 2007.05.25

Abstract

This research is a case study for improving the sound environmental quality of cafeteria in university campus. The purpose of the study is to investigate the present condition of physical level, type, and source of indoor noise by comparison with a restaurant near campus. Methods were field survey with measurement on equivalent and instant noise level and observation on noise type, and questionnaire survey to 60 students users. Surveys were carried out in the 8th and the 14th of December 2005. The results are as follows. 1) Indoor noise levels of the cafeteria were measured as $67.2{\sim}76.6$(average 73.3) dB(A)Leq5min and $60.3{\sim}90.5$(average 71.2) dB(A), but noise levels of the restaurant were $61.6{\sim}70.4$(average 66.9) dB(A)Leq5min and $59.8{\sim}70.6$(average 64.9) dB(A). 2) The users's responses on major noise type were 'noise by handling equipment and tableware', 'noise by moving chairs', and 'taking noise' in cafeteria, but 'taking noise' and 'background music' in restaurant. 3) It was found that the differences of indoor noise condition between with 2 subjects were caused by finishing materials, kitchen division type, and furniture type.

Keywords