• 제목/요약/키워드: Equivalent scattering center

검색결과 19건 처리시간 0.027초

함정의 전자기파 산란자 분포를 고려한 레이더 호밍 대함미사일 피격 위치 추정 프로그램 개발 (Development of Estimation Program for Hit Distribution by Radar-Homing Anti-Ship Missile Considering Electromagnetic Wave Scatter Distribution of Naval Ship)

  • 박성주;윤석태;김의영;정채림;김국현
    • 대한조선학회논문집
    • /
    • 제61권5호
    • /
    • pp.352-358
    • /
    • 2024
  • The susceptibility of warships denotes the hit probability by anti-ship missiles in a hostile environment. The distribution characteristics of the hit location directly influence the vulnerability. This paper proposes a simulation method to determine the hit location of radar-homing anti-ship missiles by their approach direction. The method uses high-frequency analysis theory to calculate electromagnetic scatterers and determines the equivalent scattering center position corresponding to the hit location. The proposed method was implemented to an in-house software called SCTracer/RCS, which follows the process: importing numerical analysis model, defining calculation condition, calculating electromagnetic wave scattering centers, storing to database, calling scattering center data, estimating equivalent scattering center, and analyzing hit-point distribution. To validate the feasibility and practical applicability of this software, the hit-point distribution is examined for a 90-meter-class virtual warship.

Calculation of Phase Center of Large Geomorphological Object on the Surface

  • Kim Jun-su;Park Sang-Eun;Kim Duk-jin;Moon Wooil M.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.741-744
    • /
    • 2005
  • A numerical scattering model for artificial metal structure based on physical optics approximation is developed to identify the height of phase center, and the result is compared with interferometric SAR DEM. The interferometric SAR data were gathered by AIRSAR during PACRIM- II campaign on Jeju Island. Power transmission towers on piedmont pasture along the slopes of Mt. Halla look like elliptic risings in TOPSAR DEM. The heights of risings are quantitatively analyzed using a scattering model in the way of achieving the height of phase centers of power transmission towers. A numerical algorithm is developed on the basis of physical optics approximation. The structure of power transmission tower was decomposed into hundreds of rectangular metal plates, of which the scattering matrix is known in analytic form, and the calculated scattering fields were summed coherently. The effect of direct backscattering component, ground-scatterer component and scatterer-ground component are decomposed and computed individually for each rectangular metal plate. The $\Deltak-radar$ equivalent was used to calculate height of phase center of the scatterer. The heights of a selected power transmission tower and scattering algorithm results give existence and location of the transmission towers but not actual tower heights.

  • PDF

도파관 H 면 계단형 불연속 구조를 이용한 대이동과 여파기의 설계 (Design of Waveguide Bandpass Filters Using H-plane Step Discontinuities)

  • 남수현;김근영;윤상원;안철
    • 전자공학회논문지A
    • /
    • 제31A권1호
    • /
    • pp.33-38
    • /
    • 1994
  • In this paper, waveguide banpass filters using H-plane step discontinuities are designed based on the field theory analysis and optimization of the resonator lengths as well as dimensions of discontinuities, instead of the conventional synthesis method based on the equivalent circuit. The waveguide inductive obstacles introduced by H-plane step discontinuities analyzed using mode-matching method and the generalized scattering parameters are derived. Using the derived scattering parameters of the discontinuities as well as those of resonators, waveguide bandpass filters are designed through optimization method, modified Razor search method proposed by J.H.Bandler. Using this design procedures, waveguide bandpass filters are designed and tested at X-band(center frequency 10GHz) as well as Ka-band(center frequency 35GHz).

  • PDF

슬롯 결합 마이크로스트립라인-도파관 천이기의 등가 회로 모델링 (Equivalent Network Modeling of Slot-Coupled Microstripline to Waveguide Transition)

  • 김원호;신종우;김정필
    • 한국전자파학회논문지
    • /
    • 제15권10호
    • /
    • pp.1005-1010
    • /
    • 2004
  • 슬롯 결한 마이크로스트립라인-도파관 천이기에 대해 간략하지만 정확한 등가 회로 모델을 추출하기 위한 해석 방법을 제안한다. 이 등가회로는 이상적 변압기, 마이크로스트립 개방 스터브, 그리고 슬롯 중심에서 도파관 쪽과 급전선 쪽 반평면으로 바라보는 각각의 어드미턴스들로 구성된다. 관련된 회로 변수 값들은 가역 정리 (Reciprocity theorem), 푸리에 변환과 푸리에 급수(Fourier transform and series), 복소 전력 개념(Complex power concept), 파스발 정리(Parceval's theorem), 그리고 스펙트럼 영역 이미턴스 접근법(Spectral-domain immittance approach)에 의해 계산된다. 계산된 산란계수 값을 측정된 값과 비교하였으며 이들 사이의 상당한 일치도는 제안된 등가회로 모델의 간편성과 정확성을 뒷받침한다.

TD-CFIE Formulation for Transient Electromagnetic Scattering from 3-D Dielectric Objects

  • Lee, Young-Hwan;Jung, Baek-Ho;Sarkar, Tapan K.;Yuan, Mengtao;Ji, Zhong;Park, Seong-Ook
    • ETRI Journal
    • /
    • 제29권1호
    • /
    • pp.8-17
    • /
    • 2007
  • In this paper, we present a time domain combined field integral equation formulation (TD-CFIE) to analyze the transient electromagnetic response from dielectric objects. The solution method is based on the method of moments which involves separate spatial and temporal testing procedures. A set of the RWG functions is used for spatial expansion of the equivalent electric and magnetic current densities, and a combination of RWG and its orthogonal component is used for spatial testing. The time domain unknowns are approximated by a set of orthonormal basis functions derived from the Laguerre polynomials. These basis functions are also used for temporal testing. Use of this temporal expansion function characterizing the time variable makes it possible to handle the time derivative terms in the integral equation and decouples the space-time continuum in an analytic fashion. Numerical results computed by the proposed formulation are compared with the solutions of the frequency domain combined field integral equation.

  • PDF

Physicochemical Properties of Corn Starch-derived Branched Dextrin Produced by a Branching Enzyme

  • Song, Eun-Bum;Min, Byoung-Cheol;Hwang, Eun-Sun;Lee, Hyong-Joo
    • Food Science and Biotechnology
    • /
    • 제17권2호
    • /
    • pp.234-240
    • /
    • 2008
  • The optimal conditions for the production of branched dextrin from com starch (CSBD) using branching enzyme (BE) were established by investigating the degree of retrogradation of the gelatinized starch. The physicochemical properties of CSBD prepared using the established process were evaluated. It was found that physicochemical properties of com starch were greatly modified by BE treatment. CSBD had a higher dextrose-equivalent value and water solubility than the corresponding control. On the other hand, the viscosities in gelatinized solution and amylose contents of CSBD were lower than those of the control. A high-performance size-exclusion chromatography/multiangle laser light scattering/retractive index (HPSEC/MALLS/RI) system showed that the average molecular weight of CSBD was lower than that of the control. The pasting viscosities of CSBD were stable during the entire temperature cycle. In general, the BE treatment resulted in the retrogradation during storage being lower for CSBD than for the control.

Extraction of Passive Device Model Parameters Using Genetic Algorithms

  • Yun, Il-Gu;Carastro, Lawrence A.;Poddar, Ravi;Brooke, Martin A.;May, Gary S.;Hyun, Kyung-Sook;Pyun, Kwang-Eui
    • ETRI Journal
    • /
    • 제22권1호
    • /
    • pp.38-46
    • /
    • 2000
  • The extraction of model parameters for embedded passive components is crucial for designing and characterizing the performance of multichip module (MCM) substrates. In this paper, a method for optimizing the extraction of these parameters using genetic algorithms is presented. The results of this method are compared with optimization using the Levenberg-Marquardt (LM) algorithm used in the HSPICE circuit modeling tool. A set of integrated resistor structures are fabricated, and their scattering parameters are measured for a range of frequencies from 45 MHz to 5 GHz. Optimal equivalent circuit models for these structures are derived from the s-parameter measurements using each algorithm. Predicted s-parameters for the optimized equivalent circuit are then obtained from HSPICE. The difference between the measured and predicted s-parameters in the frequency range of interest is used as a measure of the accuracy of the two optimization algorithms. It is determined that the LM method is extremely dependent upon the initial starting point of the parameter search and is thus prone to become trapped in local minima. This drawback is alleviated and the accuracy of the parameter values obtained is improved using genetic algorithms.

  • PDF

Therapeutic Proton Beam Range Measurement with EBT3 Film and Comparison with Tool for Particle Simulation

  • Lee, Nuri;Kim, Chankyu;Song, Mi Hee;Lee, Se Byeong
    • 한국의학물리학회지:의학물리
    • /
    • 제30권4호
    • /
    • pp.112-119
    • /
    • 2019
  • Purpose: The advantages of ocular proton therapy are that it spares the optic nerve and delivers the minimal dose to normal surrounding tissues. In this study, it developed a solid eye phantom that enabled us to perform quality assurance (QA) to verify the dose and beam range for passive single scattering proton therapy using a single phantom. For this purpose, a new solid eye phantom with a polymethyl-methacrylate (PMMA) wedge was developed using film dosimetry and an ionization chamber. Methods: The typical beam shape used for eye treatment is approximately 3 cm in diameter and the beam range is below 5 cm. Since proton therapy has a problem with beam range uncertainty due to differences in the stopping power of normal tissue, bone, air, etc, the beam range should be confirmed before treatment. A film can be placed on the slope of the phantom to evaluate the Spread-out Bragg Peak based on the water equivalent thickness value of PMMA on the film. In addition, an ionization chamber (Pin-point, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The eye phantom was used for independent patient-specific QA. The differences in the output and beam range between the measurement and the planned treatment were less than 1.5% and 0.1 cm, respectively. Conclusions: An eye phantom was developed and the performance was successfully validated. The phantom can be employed to verify the output and beam range for ocular proton therapy.

단락 개방 Calibration 방법을 이용한 분포 정수 소자의 기생 소자 추출 및 대역 통과 필터에의 응용 (A Parasitic Elements Extraction of the Distributed Elements and an Application of the BPF Using the Short-Open Calibration Method)

  • 김유선;남훈;임영석
    • 한국전자파학회논문지
    • /
    • 제20권2호
    • /
    • pp.115-123
    • /
    • 2009
  • 본 논문에서는 단락 개방 calibration(SOC) 방법을 이용하여 결함 접지 면을 갖는 전송 선로(DGS)와 short-circuited comb line section의 기생 소자 값들을 추출하였다. Microstrip 선로들로 구성된 단락, 개방, 분포 정수 소자의 산란 파라미터 행렬들은 전자기 시뮬레이터 및 벡터 네트웍 분석기를 이용하여 측정하였다. 제안된 구조의 전자기 영향들은 주파수 독립적인 소자들로 구성된 II형 또는 T형 등가 회로로 각각 표현하였고, 2 포트 네트웍 해석을 수행함으로써, 측정된 산란 파라미터들과 등가회로 소자들 간의 관계를 보였다. 또한, 2차 버터워스 프로토 타입을 갖는 2.4 GHz 대역 통과 필터 설계에 이를 적용하였다. 그 결과, 중심 주파수에서 측정된 $S_{11}$$S_{21}$은 각각 -20 dB, -1.3 dB 이고, $0.5{\sim}5\;GHz$에서 예상했던 결과와 5 % 이내의 오차를 보였다.

피부선량을 기준으로 0.511 MeV 감마선에 대한 납 차폐체의 산란선 및 차폐 효율 분석 (Analysis of Scattering Rays and Shielding Efficiency through Lead Shielding for 0.511 MeV Gamma Rays Based on Skin Dose)

  • 장동근;박은태
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.259-264
    • /
    • 2020
  • Radiation causes radiation hazards in the human body. In Korea, a case of radiation necrosis occurred in 2014. In this study, the scatter and shielding efficiency according to lead shielding were classified into epidermis and dermis for 0.511 MeV used in nuclear medicine. In this study, experiments were conducted using the slab phantom that represents calibration and the dose of human trunk. Experimental results showed that the shielding rate of 0.25 mmPb was 180% in the epidermis and 96% in the dermis. Shielding at 0.5mmPb showed shielding rates of 158%in the epidermis and 82% in the dermis. As a result of measuring the absorbed dose by subdividing the thickness of the dermis into 0.5 mm intervals, when the shielding was carried out at 0.25 mmPb, the dose appeared to be about 120% at 0.5 mm of the dermis surface, and the dose was decreased at the subsequent depth. Shielding at 0.5 mmPb, the dose appeared to be about 101% at the surface 0.5 mm, and the dose was measured to decrease at the subsequent depth. This result suggests that when lead aprons are actually used, the scattering rays would be sufficiently removed due to the spaces generated by the clothes and air, Therefore, the scattered ray generated from lead will not reach the human body. The ICRU defines the epidermis (0.07), in which the radiation-induced damage of the skin occurs, as the dose equivalent. If the radiation dose of the dermis is considered in addition, it will be helpful for the evaluation of the prognosis for radiation hazard of the skin.