• Title/Summary/Keyword: Equivalent radius

Search Result 129, Processing Time 0.025 seconds

Adsorbed Water in Soil a Interpreted by Its Potentials Based on Gibbs Function (Gibbs 함수의 포텐샬로 해석한 토양 흡착수)

  • 오영택;신제성
    • Journal of the Mineralogical Society of Korea
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • Usual experimental adsorption isotherms as a function of relative humidity were constructed from adsorbed water contents in soils, which were kept more than 2 days in vacuum desiccators with constant humidities controlled by sulfuric acids of various concentrations. From the experimental data, the adsorption surface areas were calculated on the basis of the existing adsorption theory, such as Langmuir, BET, and Aranovich. Based on the Gibbs function describing chemical potential of perfect gas, the relative humidities in the desiccators were transformed into their chemical potentials, which were assumed to be the same as the potentials of equilibratedly adsorbed water in soils. Moreover, the water potentials were again transformed into the equivalent capillary pressures, heads of capillary rise, and equivalent radius of capillary pores, on the basis of Laplace equation for surface tension pressure of spherical bubbles in water. Adsorption quantity distributions were calculated on the profile of chemical potentials of the adsorbed water, equivalent adsorption and/or capillary pressures, and equivalent capillary radius. The suggested theories were proved through its application for the prediction of temperature rise of sulfuric acid due to hydration heat. Adsorption heat calculated on the basis of the potential difference was dependant on various factors, such as surface area, equilibrium constants in Langumuir, BET, etc.

  • PDF

Advantage of the Intensive Light Scattering by Plasmonic Nanoparticles in Velocimetry

  • Rong, Tengda;Li, Quanshui
    • Current Optics and Photonics
    • /
    • v.6 no.1
    • /
    • pp.79-85
    • /
    • 2022
  • Tracers are one of the critical factors for improving the performance of velocimetry. Silver and gold nanoparticles as tracers with localized surface-plasmon resonance are analyzed for their scattering properties. The scattering cross sections, angular distribution of the scattering, and equivalent scattering cross sections from 53° and 1.5° half-angle cones at 532 nm are calculated, with particle sizes in the nanoscale range. The 53° and 1.5° half-angle cones used as examples correspond respectively to the collection cones for microscope objectives in microscopic measurements and camera lenses in macroscopic measurements. We find that there is a transitional size near 35 nm when comparing the equivalent scattering cross sections between silver and gold nanoparticles in water at 532 nm. The equivalent scattering cross section of silver nanoparticles is greater or smaller than that of gold nanoparticles when the particle radius is greater or smaller than 35 nm respectively. When the radius of the plasmonic nanoparticles is smaller than about 44 nm, their equivalent scattering cross sections are at least ten times that of TiO2 nanoparticles. Plasmonic nanoparticles are promising for velocimetry applications.

A Comparative Study of Quantitative Assessment of Bone Mineral Density of the Mandible (하악골 골염도의 정량적 평가에 관한 비교연구)

  • Park Won-Kyl;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.161-173
    • /
    • 1999
  • This study was performed to compare the bone mineral densities measured at mandibular premolar area by copper-equivalent image and hydroxyapatite phantom with those measured at radius by dual energy absorptiometry and to evaluate the clinical usefulness of Digital system with slide scanner, copper-equivalent image, and hydroxyapatite phantom. For experiment. intraoral radiograms of 15 normal subjects ranged from 20 years old to 67 old were taken with copper-step wedge at mandibular premolar area and bone mineral densities calculated by conversion equation to bone mineral density of hydroxyapatite were compared with those measured at radius distal 1/3 area by Hologic QDR-1000. Obtained results as follows: 1) The conversion equation was Y=5.97X-0.25 and its determination coefficient was 0.9967. The coefficient of variation in the measurement of copper-equivalent value ranged from 4% to 8% and showed high reproducibility. 2) The coefficient of variation in the measurement of bone mineral density by the equation ranged from 7% to 8% and showed high reproducibility. 3) The bone mineral densities ranged from 0.35 to 0.79g/cm2 at mandibular premolararea. 4) The correlation coefficient between bone mineral densities at mandibular premolar area and those at radius distal 1/3 area was 0.8965. As summary, digital image analyzing system using copper-equivalent image and hydroxyapatite phantom appeared to be clinically useful to measure the bone mineral density at dental area.

  • PDF

Seismic responses of structure isolated by FPB subject to pounding between the sliding interfaces considering soil-structure interaction

  • Yingna Li;Jingcai Zhang
    • Earthquakes and Structures
    • /
    • v.26 no.6
    • /
    • pp.463-475
    • /
    • 2024
  • The study aims to investigate the pounding that occurs between the isolator's ring and slider of isolated structures resulting from excessive seismic excitation, while considering soil-structure interaction. The dynamic responses and poundings of structures subjected a series seismic records were comparatively analyzed for three different soil types and fixed-base structures. A series of parametric studies were conducted to thoroughly discuss the effects of the impact displacement ratio, the FPB friction coefficient ratio, and the radius ratio on the structural dynamic response when considering impact and SSI. It was found that the pounding is extremely brief, with an exceptionally large pounding force generated by impact, resulting in significant acceleration pulse. The acceleration and inter-story shear force of the structure experiencing pounding were greater than those without considering pounding. Sudden changes in the inter-story shear force between the first and second floors of the structure were also observed. The dynamic response of structures in soft ground was significantly lower than that of structures in other ground conditions under the same conditions, regardless of the earthquake wave exciting the structure. When the structure is influenced by pulse-type earthquake records, its dynamic response exhibits a trend of first intensifying and then weakening as the equivalent radius ratio and friction coefficient ratio increase. However, it increases with an increase in the pounding displacement ratio, equivalent radius ratio, friction coefficient ratio, and displacement ratio when the structures are subjected to non-pulse-type seismic record.

An Investigation of Dissipation Analysis for Dilatometer & New Interpretation Method (딜라토메터 소산시험 해석에 대한 고찰 및 새로운 해석법)

  • 김영상
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.365-368
    • /
    • 2003
  • Despite of the simple equipment and operation, DMT has been widely used to obtain various soil parameters and those parameters have been successfully applied to geotechnical design practice. Among them, the estimation of horizontal coefficient of consolidation is so useful that many researchs recently have been carried out. However, simulation of the penetration of the DMT blade is complex due to the inherent difficulty on analyzing a plane strain deformation of the soil around blade. Therefore, empirical and semi-empirical methods that use the theoretical solution developed fur piezocone with some assumptions have been used to estimate the coefficient of consolidation from Dilatometer dissipation test. In this paper, coefficients of consolidation c$\_$h/ which were obtained using equivalent radius that is same area with the DMT blade and optimization technique are compared with those obtained from Oedometer test and other interpretation methods. It was found that a new method used in this study can give more precise horizontal coefficient of consolidation than other methods do.

  • PDF

Determination of Two Dimensional Axisymmetric Finite Element Model for Reactor Coolant Piping Nozzles (원자로 냉각재 배관 노즐의 2차원 축대칭 유한요소 모델 결정)

  • Choi, S.N.;Kim, H.N.;Jang, K.S.;Kim, H.J.
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.432-437
    • /
    • 2000
  • The purpose of this paper is to determine a two dimensional axisymmetric model through a comparative study between a three dimensional and an axisymmetric finite element analysis of the reactor coolant piping nozzle subject to internal pressure. The finite element analysis results show that the stress adopting the axisymmetric model with the radius of equivalent spherical vessel are well agree with that adopting the three dimensional model. The the radii of equivalent spherical vessel are 3.5 times and 7.3 times of the radius of the reactor coolant piping for the safety injection nozzle and for the residual heat removal nozzle, respectively.

  • PDF

Study on the Thermal Transient Response of TSV Considering the Effect of Electronic-Thermal Coupling

  • Li, Chunquan;Zou, Meng-Qiang;Shang, Yuling;Zhang, Ming
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.3
    • /
    • pp.356-364
    • /
    • 2015
  • The transmission performance of TSV considering the effect of electronic-thermal coupling is an new challenge in three dimension integrated circuit. This paper presents the thermal equivalent circuit (TEC) model of the TSV, and discussed the thermal equivalent parameters for TSV. Si layer is equivalent to transmission line according to its thermal characteristic. Thermal transient response (TTR) of TSV considering electronic-thermal coupling effects are proposed, iteration flow electronic-thermal coupling for TSV is analyzed. Furthermore, the influences of TTR are investigated with the non-coupling and considering coupling for TSV. Finally, the relationship among temperature, thickness of $SiO_2$, radius of via and frequency of excitation source are addressed, which are verified by the simulation.

Equivalent Circuit Parameters of S-band 1.5 Cell RF Gun Cavity

  • Kim, Ki-Young;Kang, Heung-Sik;Tae, Heung-Sik
    • Journal of electromagnetic engineering and science
    • /
    • v.4 no.1
    • /
    • pp.30-36
    • /
    • 2004
  • We determined equivalent circuit parameters of a 1.5 cell S-band RF gun cavity from the resonant characteristics of its decoupled cavities(half cell and full cell) using the code SUPERFISH. Equivalent circuit parameters of the 1.5 cell RF gun cavity resonated in the 0-mode were obtained easily from the circuit parameters of each decoupled cavities. In order to obtain equivalent circuit parameters for the $\pi$ -mode cavity, we calculated the differences of the resonant frequencies and the equivalent resistances between the 0- and $\pi$ -modes with slight variations of the radius and thickness of the coupling iris. From those differences, we obtained R/Q value and equivalent resistance of the $\pi$ -mode, which are directly related to the equivalent circuit parameters of the coupled cavity. Using calculated R/Q value, we can express equivalent inductance, capacitance and resistances of the RF gun cavity resonated in the $\pi$ -mode, which can be useful for analyzing coupled cavities in a steady state.

Equivalent Continuum Model for the Single Wall Carbon Nanotube (Single Wall Carbon Nanotube의 등가 연속체 모델에 대한 연구)

  • 김병구;전흥재
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.227-234
    • /
    • 2003
  • In this study, an equivalent continuum model for single wall carbon nanotube is proposed. The model links interatomic potentials and atom structure of a materials to a constitutive model on the continuum level. The Young's modulus and shear modulus were predicted by the model. The predictions were in good agreement with the prior experimental results available in the literatures. Also, the strain energy of the carbon nanotube was predicted as a function of the radius of the carbon nanotube.

  • PDF

The Relationship between Lifetime Sports Activity Measured with MET and Peak Strain Score and Bone Measurement in College-aged Women (대사당량(MET)과 최대긴장력(Peak Strain Score)에 근거하여 측정한 스포츠 활동량과 여대생의 요골 골밀도와의 상관성)

  • Lee, Eun-Nam;Choi, Eun-Jung
    • Journal of Korean Academy of Nursing
    • /
    • v.38 no.5
    • /
    • pp.667-675
    • /
    • 2008
  • Purpose: The aim of this study was to compare the relation between differently measured sports activities (metabolic equivalent [MET] and peak strain score) and distal radius bone mineral density in college-aged women. Methods: lifetime sports activity was scored in two different ways: 1) a sports activity score by multiplying the intensity (METs) and duration and 2) a sports activity score by adding up physical strain scores based on the ground reaction force of each sports activities. Bone mineral density was measured using dual energy x-ray densitometry (DTX-200) in the distal radius site. Results: In stepwise multiple regression analysis, body weight and sports activities during the college period were significant positive predictors for distal radius bone mineral density. The explained variance of sports activity measured with a peak strain score (8.8%) for distal radius bone mineral density was higher than one measured with the MET score (3.3%). Conclusion: It can be concluded that sports activity scores based on MET and peak strain scores during college are very important for determining the bone mineral density in the distal radius site in women under 30.