• 제목/요약/키워드: Equivalent noise

검색결과 616건 처리시간 0.023초

NEMA NU2-2001을 이용한 PET-CT 스캐너의 물리적 특성평가 (Evaluation of Physical Characteristics of Discovery ST scanner Using NEMA NU2-2001 Standard)

  • 이병일
    • 통합자연과학논문집
    • /
    • 제1권2호
    • /
    • pp.79-83
    • /
    • 2008
  • As a new standard for performance measurement, NEMA NU2-2001 was presented recently. In this study, I investigated the spatial resolution, sensitivity, scatter fraction, and noise equivalent count ratio (NECR) in order to know the information of physical characteristics and system performance of GE discovery ST using this new standard. Bismuth germinate crystals ($6{\times}6$ array, $6.3mm{\times}6.3mm{\times}30mm$) were used in discovery ST (energy window:375-650 keV, coincidence window:11.7 nsec). To measure the sensitivity, five aluminum sleeves (Data Spectrum Corp., Chapel Hill, NC., USA, thickness:1.25 mm)-NEMA sensitivity phantom- filled with F-18 solution were used. Successive measurements in 2D and 3D acquisition mode were made with a line source at the center of transaxial field of view and 10 cm off from the center until the count was over 500,000. Spatial resolution was estimated using a point source (F-18, 0.1 mCi) at different locations in the FOV. Scatter fraction and NECR was tested using a NEMA scatter phantom. Dynamic data were acquired for 7 half-lives using F-18 solution. And true to background ratio was averaged at last three frames when the random rate was as small as ignorable for the calculation of scatter fraction. We anticipate this overall evaluated results could be used for the quality assurance and optimized image acquisition for clinical research.

  • PDF

새로운 전극 설계법을 이용한 인체 감지형 초전형 적외선 센서 시스템 (Human detecting pyroelectric infrared sensor system using new electrode design)

  • 권성열
    • 융합신호처리학회논문지
    • /
    • 제3권4호
    • /
    • pp.74-78
    • /
    • 2002
  • 인체감지용 초전형 적외선 센서 시스템은 최소 2개 이상의 센서를 사용한다. 상부전극과 바닥전극의 디자인을 새로이 하여 센서 2개가 인체감지를 가능하게 하는 센서 시스템을 센서 1개로 구성한 변환기를 설계하였다. 초전성 효과를 나타내는 재료로는 P(VDF/TrFE) 필름을 이용하였다 제작된 적외선 센서는 기존의 2개 이상의 센서를 사용하던 시스템에 비해 거의 같은 결과인 적외선원 13 $\times$ 10$10^-6$ 에 대하여 9.62 $\times$ 10$10^5$ V/W 의 높은 전압감도를 나타내었으며 NEP (noise equivalent power) 는 3.95 $\times$ $10^-7$/ W, 그리고 specific detectivity D$^*$는 5.06 $\times$ $10^5$ cm/W나타내었다.

  • PDF

수중음향 영상화를 위한 렌즈 제작 및 특성 평가 (Characteristics Evaluation of the Lens for Underwater Acoustic Imaging)

  • 조완호;권휴상;조요한;서희선
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.687-696
    • /
    • 2016
  • A series of process to design an acoustic lens for underwater imaging is reviewed and the method to evaluate characteristics of the lens is investigated. If the target specification of lens is given, the design process consists of the material selection, evaluation of its properties, lens geometry design, prediction of lens characteristics, manufacturing, and evaluation by measurement. In this study, an actual acoustical lens is made by cutting polymethylpentene block. The characteristics of lens are predicted by the hybrid method, combination of ray tracing and Rayleigh integral. For the direct comparison between the prediction and measurement results, a simulation method based on the equivalent source method is suggested to reflect the actual radiation pattern of transducer used for measurements. Finally, the measurement is conducted in a small water tank to observe the actual characteristics of the manufactured lens.

차량루프의 진동저감을 위한 수동구속감쇠처리의 위치 최적화 (An Optimal Placement of passive Constrained Layer Damping Treatment for Vibration Suppression of Automotive Roof)

  • 이기화;김찬묵;강영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.349-353
    • /
    • 2004
  • A study on optimal placement of constrained layer damping treatment for vibration control of automotive panels is presented. The effectiveness of damping treatment depends upon design parameters such as choice of damping materials, locations and size of the treatment. This paper proposes a CAE (Computer Aided Engineering) methodology based on finite element analysis to optimize damping treatment. From the equivalent modeling technique, it is found that the best damping performance occurs as the viscoelstic patch is placed by means of the modal strain energy method of bare structural panels to identify flexible regions, which in turn facilitates optimizations of damping treatment with respect to location and size. Different configurations of partially applied damping layer treatment have been analyzed for their effectiveness in realizing maximum system damping with minimum mass of the applied damping material. Moreover, simulated frequency response function of the automotive roof with and without damping treatments are compared, which show the benefits of applying damping treatment. Finally, the optimized damping treatment configuration is validated by comparing the locations and the size of the treatment with that of an experimental modal test conducted on roof compartment.

  • PDF

공기청정기와 가습기의 소음특성 (Noise Characteristics of Air Cleaners and Humidifiers)

  • 김용희;박지훈
    • 한국소음진동공학회논문집
    • /
    • 제26권1호
    • /
    • pp.20-26
    • /
    • 2016
  • This study investigated noise characteristics of air cleaners and humidifiers in terms of frequency domains and measurement directions. Noise levels of 31 air cleaners and 36 humidifiers were measured in an anechoic chamber according to the related group standards. As for air cleaners, 5 receiving points of 1 m off from front, rear, left, right and top surfaces of the product were considered. In case of humidifiers, 4 receiving points without the rear position were considered in the same manner as air cleaners. In each case, A-weighted equivalent continuous sound level was measured three times for 1 min. As a results, most of the measured air cleaners and humidifiers showed the highest noise levels at top directions due to the air ventilating location. In case of air cleaners, averaged noise levels of top and rear positions were 49.9 and 48.2 dB(A), respectively, whereas averaged noise level of other positions was all 45.2 dB(A). In case of humidifiers, averaged noise level of top position was 44.1 dB(A) whereas averaged noise levels of other positions were 38.7 to 39.1 dB(A). In addition, high frequency content of 1 kHz and 3.15 kHz to 4 kHz for air cleaners and middle frequency content of 500 Hz to 1.6 kHz for humidifiers showed significant contribution to determination of overall noise levels with correlation coefficient of 0.9 and above.

음향을 이용한 복합 적층판의 층간분리 예측 (Prediction of Delamination for Composite Laminates Using Sound Radiation)

  • 김성준;채동철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.800-804
    • /
    • 2005
  • In this paper, the radiated sound pressure induced by low velocity impact is obtained by solving the Rayleigh integral equation. For structurally radiated noise, the sound field is directly coupled to the structural motion. Therefore the impact response should be analyzed. It is well known that the presence of the delamination in a composite laminate introduces a local flexibility which changes the dynamic characteristic of the structure. The 2-D simplified delamination model is used to analyze the impact response. And the 3-D non-linear finite element model is developed using gap element to avoid the overlap and penetration between the upper and lower sub-laminates at delamination region. Predicted impact response using 2-D equivalent delamination model are compared with the numerical ones from the 3-D non-linear finite element model.

  • PDF

산업용 로봇 손목의 동력 전달계에 대한 동특성 해석 (Dynamic Analysis of the Power Transmission System in an Industrial Robot)

  • 김우형;정진태
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.913-919
    • /
    • 2008
  • Dynamic characteristics of a wrist power transmission of an industrial robot are studied. The wrist power transmission has complex structure characteristics, because it is composed with several shafts and gear system. We used an analytical method to investigate the dynamic characteristics. An analytical model is a rigid model which is composed with masses and springs. Both bearing and gear contact model represent equivalent stiffness springs which are determined by the experiment. In order to investigate the dynamic tendency of the robot wrist power transmission, we simulate the analytical model. There is a dynamic analysis tool which is called the RecurDyn. To verify the analytic results, we experiment a signal analysis which is an overall noise level of the robot. By the parametric study of the element of the robot, we study an improvement method of dynamic characteristics.

새로운 형태의 휴대폰용 브러쉬리스 센서리스 진동모터의 설계 (Novel Design of Brushless and Sensorless Vibration Motor Used for Cell-Phones)

  • 이홍주;김광석;이창민;황건용;황상문
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.224-229
    • /
    • 2008
  • With the wide use of mobile phones, a paging signal by a sound transducer acts as an environmental noise on many occasions, thus necessitating an alternative paging signal by a vibration motor. Conventional vibration motors employ three-phase windings with mechanical brushes for commutation. In this paper, a new one-phase brushless and sensorless vibration motor is introduced utilizing digital signal processor chips in cell-phones. For electromagnetic field analysis, two-dimensional modeling can be implemented to determine the back electromotive force using axisymmetric boundary conditions. Geometric design parameters, such as coil pitch and magnet pitch. are considered for performance optimization. Through the experiments, it is shown that the proposed design has the equivalent performance with reduced number of parts, thus enhancing manufacturing productivity and reducing manufacturing cost.

  • PDF

천이 경계층 유동의 벽면 변동 압력에 관한 실험적 연구 (Experimental Study of Wall Pressure Fluctuations in the Regions of Flow Transition)

  • 신구균;홍진숙;전재진;김상윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.811-816
    • /
    • 2000
  • It has been long suspected that the transition region may give rise to local pressure fluctuations and radiated sound that are different from those created by the fully-developed turbulent boundary layer at equivalent Reynolds number. Experimental investigation described in this paper concerns the characteristics of pressure fluctuations at the transition. Flush-mounted microphones and hot wires are used to measure the pressure fluctuations and local flow velocities within the boudary layer in the low noise wind tunnel. From this experimental we could observe the spatial and temporal development process of T-S wave using Wigner-Ville method and found the possibility of relation between the characteristic frequency of T-S wave and free stream velocity and the boundary layer thickness based on nondimensional pressure spectra scaled on outer variables.

  • PDF

나선형 인덕터의 디임베드 검증을 통한 CMOS LNA 설계 및 제작 (The Design and Fabrication of CMOS LNA through De-embedded Verification of the Spiral Inductor)

  • 이한영;유영길
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2269-2275
    • /
    • 2008
  • This paper examined the simulation results after applying not only spiral inductor's 3D EM simulation but also de-embedding technique to reduce the pad's RF effects. When calculating standard deviation with measurement results not only the gain at 0.5GHz${\sim}$4GHz but also noise figure at 1.8GHz${\sim}$4GHz, the simulation results includes de-embedded inductor' model improved gain deviation by 0.171 and noise figure deviation by 0.151 than the results from simulation with foundry inductor equivalent circuit models.