• Title/Summary/Keyword: Equivalent noise

Search Result 616, Processing Time 0.026 seconds

Equivalent damping ratio based on earthquake characteristics of a SDOF structure with an MR damper (지진특성에 따른 MR 감쇠기가 설치된 단자유도 구조물의 등가감쇠비)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.459-464
    • /
    • 2007
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally, response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

  • PDF

Optimization of the Number and Position of Far Field Sources in Using the Equivalent Source Method (등가음원법에서의 원거리음원의 위치와 개수의 최적화 연구)

  • 백광현
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.10
    • /
    • pp.743-750
    • /
    • 2003
  • The equivalent source method(ESM) is used for the calculation of the internal pressure field for an enclosure which can have arbitrary boundary conditions and nay include internal objects which scatter the sound field. The advantage of using ESM is that it requires relatively low computing cost and is easy to model the internal diffracting objects. Typical ESM modeling uses two groups of equivalent source positions. One group includes the first order images of the source inside the enclosure. The Positions of the other group are usually on a spherical surface some distance outside the enclosure. The normal velocity on the surfaces of the enclosure walls is evaluated at a larger number of positions than there are equivalent sources. The sum of the squared difference between this velocity and the expected is minimized by adjusting the strength of the equivalent sources. This study is on the optimal far field sources positions when using the equivalent source method. In general, the far field sources are evenly distributed on a surface of a virtual sphere which is centered at the enclosure with a sufficiently large radius. In this study. optimal far field source locations are searched using simulated annealing method for various radii of spheres where far field sources are located. Simulation results showed that optimally located sources with adequate distance away from the enclosure center gave better result than sources with even distribution even with a smaller number of far field sources.

Equivalent damping ratio based on the earthquake response of a SDOF structure with a MR damper (MR 감쇠기가 설치된 단자유도 구조물의 지진응답에 기초한 등가감쇠비)

  • Park, Ji-Hun;Moon, Byoung-Wook;Min, Kyung-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.879-885
    • /
    • 2006
  • Seismic control performance of MR dampers, which have severe nonlinearity, differs with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally, response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

  • PDF

Equivalent Damping Ratio Based on Earthquake Characteristics of a SDOF Structure with an MR Damper (지진특성에 따른 MR감쇠기가 설치된 단자유도 구조물의 등가감쇠비)

  • Moon, Byoung-Wook;Park, Ji-Hun;Lee, Sung-Kyung;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.1
    • /
    • pp.87-93
    • /
    • 2008
  • Seismic control performance of MR dampers, which have severe nonlinearity, varies with respect to the dynamic characteristics of an earthquake such as magnitude, frequency and duration. In this study, the effects of excitation characteristics on the equivalent linear system of a building structure with the MR damper are investigated through numerical analysis for artificial ground motions generated from different response spectrums. The equivalent damping ratio of the structure with the MR damper is calculated using Newmark and Hall's equations for ground motion amplification factors. It is found that the equivalent damping ratio of the structure with the MR damper is dependent on the ratio of the maximum friction force of the MR damper over excitation magnitude. Frequency contents of the earthquake ground motion affects the equivalent damping ratio of long-period structures considerably. Also, additional damping effect caused by interaction between the viscousity and friction of the MR damper is observed. Finally. response reduction factors for equivalent linear systems are proposed in order to improve accuracy in the prediction of the actual nonlinear response.

A Study on the Noise Characteristics and Assessment of Fighter and Civil Aircraft (전투기와 민간 항공기의 소음특성과 평가에 관한 연구)

  • Ju, Kyung-Min;Lee, Jong-Seok;Kim, Deok-Han;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.227-230
    • /
    • 2005
  • This paper describes the problems in measuring and evaluating the aviation noises and the differences on the noise characteristics between fighter and civil aircraft. From a standpoint of the duration time for aviation noise and the dynamic characteristics related with the sampling time, the measured values for landing and taking-off noises from the fighter are presented and explained in comparison with those from the civil aircraft. And also the aviation noises by the fighter and civil aircraft are evaluated by equivalent sound level and WECPNL, respectively. From the obtained results, it is recommended that the duration time and dynamic characteristics be deeply considered in evaluating and measuring the aviation noises, since they have a great influence on the final assessment results. As the number of flight is not sufficient and the noise source is strong impulse type, moreover, the aviation noise should be assessed by WECPNL.

  • PDF

Sound Power Evaluation of Various Domestic Railroad Vehicles (국내 철도 차량의 음향발생 특성에 대한 비교 연구)

  • Kim, Jeung-Tae;Cho, Sung-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.1
    • /
    • pp.28-37
    • /
    • 1999
  • Many residential areas are situated near to railroad tracks so that a railroad noise has been one of the major environmental issues. In this paper two important aspects have been investigated in order to properly evaluate the railroad vehicle noise : sound power levels for different types and sound propagation characteristics of the railroad vehicles. For noise source characteristics of railroad vehicles, sound power values for various types of trains that are in active service have been measured. In this paper, domestic railroad vehicles are measured and compared with high speed train(TGV). Based on sound power information of railway vehicles, prediction on the sound pressure level and equivalent noise level near to railway areas have been evaluated.

  • PDF

Modeling of the Minimum nNise Figure and the Optimum Source Impedance of FETs using the Steady-state Nyquist Theorem for Multi-Terminal Semiconductor Devices (다단자 반도체 소자에서의 steady-state Nyquist 정리를 이용한 FET의 회소 잡음 지수 및 최적 소오스 임피던스 모델링)

  • 이정배;민홍식;박영준
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.110-117
    • /
    • 1995
  • New formulas for the minimum noise figure and the optimum source impedance of microwave FETs are derived using the noise equivalent circuits obtained from the steady-state Nyquist theorem for multi-terminal semiconductor devices. The derived formulas manifest the relationships between the noise sources and the physical parameters of a noise equivalent circuit. Furthermore the formulas can explain the effect of gate leakage current on the minimum noise figure and the optimum source impedance. comparisons with the published experimental data confirm the validity and usability of our formula.

  • PDF

Equivalent Circuit Modeling of Wideband Underwater Acoustic Piezoelectric Vibrator (광대역 수중 음향 압전 진동체의 등가회로 모델링)

  • 조치영;김원호;윤형규
    • Journal of KSNVE
    • /
    • v.6 no.5
    • /
    • pp.645-652
    • /
    • 1996
  • In this paper an identification method is presented to obtain the equivalent electric circuit model of a wideband underwater acoustic piezoelectric vibrator. Unknown parameters involved in the equivalent circuit are indentified using the measured electrical admittances in air. The proposed method is applied to an example transducer. The validity of equivalent circuit model is demonstrated by the comparison between the experimental measurements and analytical calculations of TVR(transmitting voltage response) in water.

  • PDF

Vibration Analysis of Trapezoidally Corrugated Plates (사다리꼴 주름판의 진동해석)

  • Kim, Young-Wann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.10
    • /
    • pp.928-934
    • /
    • 2013
  • In this paper, the vibration characteristics of the trapezoidally corrugated plate are investigated by the analytical method. The corrugated plate is widely used as the structural elements because of its high stiffness and light weight. Because the corrugated plate is flexible in the corrugation direction and stiff in the transverse direction, it is treated as an equivalent orthotropic plate to analyze the corrugated plate simply. This equivalent plate must include both extensional and flexural effect to obtain the precise solution. The effective extensional and flexural stiffness of the equivalent plate are derived to consider these effects in the analysis. To demonstrate the validity of the proposed approach, the comparison is made with the previously published results and ANSYS solutions. Some numerical results are presented to check the effect of the geometric properties.

The Error Involved in the Equivalent Electroacoustic Circuit Approach for the Element of Straight Pipe in Multiple Layer Perforated Plate Systems (다중 다공판 시스템에서 직관요소에 대한 전기음향등가회로법의 오류)

  • 이동훈;권영필
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.3
    • /
    • pp.180-185
    • /
    • 2003
  • The equivalent electroacoustic circuit approach has been conventionally used for the analysis of the multiple layer perforated plate system. However, it is found that an analogy error has been involved in the equivalent electroacoustic approach proposed by previous researchers for the element of straight pipe. Although the pipe between the perforated layers is a distributed element in the analogy, it has been treated as a parallel element by previous investigators. The analogy error is demonstrated by comparing the calculated absorption coefficients based on the parallel circuit and the distributed circuit, respectively, with the measured values by the two-microphone impedance tube method.