• Title/Summary/Keyword: Equivalent circuits

Search Result 291, Processing Time 0.03 seconds

Device Characteristic and Voltage-Type Inverter Simulation by Power IGBT Micro Modeling (전력용 IGBT의 미시적인 모델링에 의한 소자특성 및 전압형 인버터 시뮬레이션)

  • 서영수;백동현;조문택;이상훈;허종명
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.63-66
    • /
    • 1996
  • An micro model for the power insulated Gate Bipolar Transistor(IGBT) is developed. The model consistently described the IGBT steady-state current-voltage characteristics and switching transient current and voltage waveform for all loading conditions. The model is based on the equivalent circuit of a MOSFET with supplies the base current to a low-gain, high-level injection, bipolar transistor with its base virtual contact at the collector and of the base. Model results are compared with measured turn-on and turn-off waveform for different drive, load, and feedback circuits.

  • PDF

New Soft-Switching Current Source Inverter for Photovoltaic Power System

  • Han Byung-Moon;Kim Hee-Joong;Baek Seung-Taek
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.644-649
    • /
    • 2001
  • This paper proposes a soft-switching current -source inverter for photovoltaic power system, which has an H-type switched-capacitor module composed of two semiconductor switches, two diodes, and an L-C resonant circuit. The operation of proposed system was analyzed by a theoretical approach with equivalent circuits and verified by computer simulations with SPICE and experimental works with a hardware prototype. The proposed system could be effectively applied for the power converter of photovoltaic power system interconnected with the power system.

  • PDF

Simulation and Parameter Identification of Induction Machine in Load Modeling based on the Static Circuit Analysis (정태회로해석에 의한 전력부하로서의 유도전동기 시뮬레이션 및 파라메터 식별)

  • Lee, Bong-Yong;Shim, Keon-Bo;Ko, Tae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.370-374
    • /
    • 1991
  • This paper presents a static circuit model for static ant dynamic simulation of induction motors and identification of motor parameters. Instead of usual T-circuits, equivalent ${\pi}$-circuit has been proposed so that power Inputs into motor terminals can very easily calculated with very well known load flow method. It has been shown that, with wide range variation of applied voltage and frequency, successful static simulations can be performed and further the proposed static model can be used to simulate dynamic characteristics. Finally it is shown also that motor parameters can easily be identified based on the proposed static circuit.

  • PDF

Boost-Half Bridge Single Power Stage Configured PWM DC-DC Converter for Residential PEFC Stack Interface.

  • Khairy, Fathy;Choi, Kwang-Ju;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.132-134
    • /
    • 2006
  • This paper presents the design and implementation of 1 kW prototype DC-DC power converter with bridge voltage-doubler suitable for small scale PEM fuel cell system and its associated control scheme. The operation principle of this converter is described using some operating waveforms and the switching mode equivalent circuits based on simulation results and a detailed circuit operation analysis and soft-switching conditions.

  • PDF

Analysis of Rate-of-rise of VFTO in GIS according to Measurement Point (측정 위치에 따른 GIS에서 VFTO 상승률 분석)

  • Oh, Yun-Sik;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.519-520
    • /
    • 2011
  • In Gas Insulated Substation(GIS), Very Fast Transient Overvoltages(VFTOs) are generated by the switching operation of disconnector or circuit breaker and it is propagated to each component of GIS. Each component of GIS is modeled by lumped line model and distributed line model based on equivalent circuits. The various cases which can be operated and the various closing point-on-wave are considered. In this paper, magnitude and rate-of-rise of VFTO are simulated and analyzed by comparing the simulation results. Measurements are performed at transformer and circuit breaker.

  • PDF

Calculation of an Induced Voltage on Telecommunication Lines in Parallel Distribution Lines (병행 배전선로에서의 통신선 유도전압 계산)

  • Kim, Hyun-Soo;Rhee, Sang-Bong;Yeo, Sang-Min;Kim, Chul-Hwan;Lyu, Seong-Heon;Kim, Seong-Arm;Weon, Bong-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.10
    • /
    • pp.1688-1695
    • /
    • 2008
  • Recently, it is common in a distribution system of Korea Electric Power Corporation (KEPCO) to find instances where distribution lines are parallel. A traditional method of an induced voltage calculation is not suitable for parallel distribution lines. For more actual analysis of induced voltage on telecommunication lines in parallel distribution lines, a new calculation method is needed. This paper presents a new calculation method of an induced voltage on telecommunication line using equivalent ${\pi}$ circuits matrix in parallel distribution lines. The advantages of the calculation method are using actual neutral current value and not using screening factor for considering the overhead ground wire and the neutral wire. To verify the effectiveness and the accuracy of the method, various case studies are performed with EMTP(Electro-Magnetic Transients Program).

Design and Analysis of Thrust Magnetic Bearing/Damper for 300HP Class High Speed Motor (300마력급 초고속 전동기의 스러스트 자기 베어링/댐퍼 설계 및 특성해석)

  • Jang, Seok-Myeong;Choi, Jang-Young;Park, Ji-Hoon;Lee, Yong-Bok;Lee, Hee-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.5-7
    • /
    • 2007
  • This paper deals with design and analysis of thrust magnetic bearing for 300HP class high speed motor. Using the solutions obtained from equivalent magnetic circuits, we predicts the electromagnetic characteristics such as thrust, time constant and power loss according to design parameters. And then, using non-linear finite element analysis, a detailed design is performed considering saturation in order to meet requirements.

  • PDF

Analysis of Current Fed Full Bridge DC-DC Converter with Active Clamp (능동 클램프형 전류형 단상 풀브리지 DC-DC 컨버터의 동작 해석)

  • Cha, Han-Ju;Choi, Soon-Ho;Ahn, Chi-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.205-207
    • /
    • 2007
  • Isolated Current fed full-bridge converter with active clamp is analyzed in this paper. An active clamp branch is used for limiting the voltage overshoot in the bridge switches and rectifier diodes. Zero voltage switching(ZVS) is also realized by using the energy stored in the transformer leakage inductance. To analyze the converter, 6 modes of operation are introduced and investigated. For each of the modes, voltage and current equations are derived together with corresponding equivalent circuits. 200W prototype dc-dc converter is assembled and verifies the effectiveness of the analysis and simulation.

  • PDF

Simulation Study of Characteristics for Device of the High Voltage Pulse Generator (고전압 펄스 발생 장치의 특성에 관한 시뮬레이션 연구)

  • Kim, Young-Ju;Shin, Ju-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.80-86
    • /
    • 2012
  • The high-voltage pulse generator is consist of transformers of fundamental wave and harmonic waves, and shunt capacitances. The pulse has the fundamental wave and the harmonic waves that have been increased as a series circuit by the transformers to make high voltage pulse. This paper shows the high-voltage pulse generator simulation using a circuit program with experiment data. In the equivalent circuit, magnetized inductances and loss resistances which affect output voltage, have been obtained. The output capacitor circuits have characteristics of band pass. The output voltages of the pulse width 50% and 25%(PWM) were obtained. The output of the high-voltage pulse generator is 2.5kHz, 1.8kV.

Optimal Design of a DC-DC Converter for Photovoltaic Generation

  • Kwon, Soon-Kurl
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.40-49
    • /
    • 2011
  • This paper presents novel circuit topology of half-bridge soft-switching PWM inverter type DC-DC high power converter for DC bus feeding power plants. The proposed DC-DC power converter is composed of a typical voltage source-fed, half-bridge high frequency PWM inverter with a high frequency planar transformer link PWM control scheme and parallel capacitive lossless snubbers. The operating principle of the new DC-DC converter treated here is described by using switching mode-equivalent circuits, together with its unique features. All the active power switches in the half-bridge arms and input DC bus lines can achieve ZCS turn-on and ZVS turn-off commutation transitions. The total turn-off switching losses of the power switches can be significantly reduced. As a result, high switching frequency IGBTs can actually be selected in the frequency range of 40[kHz] under the principle of soft-switching. The performance evaluations of the experimental setup are illustrated practically.