• Title/Summary/Keyword: Equivalent Port Model

Search Result 50, Processing Time 0.031 seconds

Equivalent Model Parameter Extraction of SiGe Heterojunction Bipolar Transistor (SiGe Heterojunction Bipolar Transistor의 등가모델 파라미터 추출)

  • 이성현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.49-52
    • /
    • 2002
  • A new method is developed to extract model parameters of SiGe HBT equivalent circuit including the base impedance and base-collector junction capacitance. Using this method, all resistances and capacitances of SiGe HBT are independently determined from measured S-parameters using two-port parameter formula. This method is proposed to reduce possible errors generated from global optimization process, and its accuracy has been verified by finding good agreements between measured and modeled current / power gain up to 18 GHz.

  • PDF

Design of Broad Band Electromagnetic Wave Absorbers with Cross-Shaped Ferrite. (십자형 광대역 페라이트 전자파흡수체의 설계)

  • 김동일;전상엽;정세모
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1996.09a
    • /
    • pp.125-134
    • /
    • 1996
  • A design method of double layered electromagnetic wave absorbers with cross-shaped ferrite prominence in the second layer which has broad band frequency characteristics was proposed. The broad band electromagnetic wave absorber can be designed under some approximations by the theoretical model using the equivalent material constants method for the second layer. Based on the developed model broad band electromagnetic wave absorbers with excellent reflectivity frequency characteristics in the frequency range of 30MHz to 3,990MHz were designed.

  • PDF

A Novel Design of Compact Low-Pass Filter and Its Equivalent Circuit Model

  • Li, Rui;Kim, Dong-Il;Choi, Chang-Mook;Song, Young-Man
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.79-84
    • /
    • 2006
  • A novel design of compact low-pass filter based on microstrip structure and its equivalent-circuit model are developed. The philosophy of the structure behind this novel microstrip low-pass filter is simple as it is composed of a pair of symmetrical parallel coupled-line and an open-stub. With this configuration, a finite attenuation pole near the stopband cutoff frequency is available and adjustable by simply tuning the circuit parameters. Furthermore, the rejection bandwidth of this type of low-pass filter can be extended. In order to validate the feasibility of the proposed design method, a low-pass filter based on a microstrip structure is designed, fabricated, and measured. Experimental results agree very well with the simulation and analytical results.

  • PDF

S-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 S영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Lee, J.T.;Han, H.H.;Kim, H.J.;Chong, D.I.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.143-144
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using S-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a S-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Z-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 Z영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Kim, K.Y.;Lee, J.T.;Han, H.H.;An, B.C.;Jeon, Y.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.145-146
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient. Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using Z-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a Z-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Determination of Container Ship' s Economical Replacement Policy by Fuzzy Annual Equivalent Cost Method (퍼지 연등가 비용법을 이용한 선박의 경제적 교체시기 결정)

  • Jang, Woon-Jae;Keum, Jong-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.241-242
    • /
    • 2007
  • This paper aims to determination of container ship's economical replacement policy by Fuzzy Annual Equivalent Cost Method Especially, though there was much vagueness to expense for calculation of container ship's economical life, this paper expressed such vague nature with a fuzzy number. And this paper developed the fuzzy expense model with a fuzzy number, and to analyze more practically than an expense model, was decided economical life-age with an application in a containership of various volumes.

  • PDF

Earthquake Response Analysis at Port Island during the 1995 Hyogoken-nanbu Earthquake(Japan) (일본 한신 대지진에 있어서의 포트 아일랜드의 지진응답해석)

  • 황성춘
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.477-484
    • /
    • 2000
  • Earthquake response analyses are conducted for the investigation of the ground shaking during the 1995 Hyogoken-nambu earthquake. Port Island a man made island with about 8{{{{ KAPPA m^2 }} area is chosen for this purpose Because earthquake measurement with vertical array was conducted there. Strain dependent characteristics of soil can be modeled well into Hardin-Drnevich Model. Four analyses are conducted : total stress analysis by equivalent linear method non-linear method. and two effective stress analyses. All analyses except equivalent linear analysis show fairy good agreement with observed record mainly because the non-linear behavior of Holocene clay layer has predominant effect on the behavior of fill, However detailed investigation show that effective stress analyses give much better prediction than total stress analyses.

  • PDF

Perfectly-Matched DC Blocks Terminated in Arbitrary Impedances (임의의 종단 임피던스를 갖는 DC Block의 완전 정합)

  • Ahn, Hee-Ran;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.895-903
    • /
    • 2007
  • Design equations of DC blocks terminated in arbitrary impedances are newly suggested and a microstrip DC block is tested for the perfect matching. The DC block is a two-port passive component and the power excited at a port is transmitted into another port. However, all the excited power at the input can not be delivered to the output and therefore most of the conventional DC blocks can not be perfectly matched with arbitrary termination impedances. To solve the matching problem, its one-port equivalent resonant circuit model, front which design equations can be derived, is newly suggested. Using the derived design equations, any DC block can be designed, perfectly matched without any restriction of coupling coefficients. To verify the derived design equations, measurements were carried out and the results are in good agreement with prediction, showing insertion and return losses at 4.1 GHz are 0.82dB and -31dB, respectively.

Q measurement of two port RE cavity by scattering parameters (산란행렬에 의한 2단자망 RF 공동공진기의 Q 측정)

  • 한대현
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.4
    • /
    • pp.895-899
    • /
    • 2000
  • A method of measuring Q of a two port cavity by scattering parameters is proposed. The scattering parameters of a two port cavity resonator are derived by a lumped equivalent circuit model as a function of cavity parameters, including the cavity Q. These can be also obtained by direct measurement with a modern network analyzer, The results show good agreement with those from other well-known methods. This two port measurement can provide additional information such as the coupled power ratio, which is one of the important parameters for the beam accelerating cavities.

  • PDF

Characteristics of film bulk acoustic resonators(FBAR) filters design with varying configuration of resonator (다양한 공진기 형태에 따른 압전박막필터 설계 및 특성)

  • Jong, Jung-Youn;Kim, Yong-Chun;Kwon, Sang-Jik;Kim, Kyung-Hwan;Yoon, Seok-Jin;Choi, Hyung-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.275-278
    • /
    • 2003
  • The aim of the study is to scrutinize the relationship between the area of resonance and center frequency with varying thickness by analyzing the characteristics of 2-port resonator. This was done through ideal design using Leach model equivalent model modified Mason model equivalent circuit for the application of bandpass filter high-frequency band with resonator Moreover, through the design of ladder-type BPF, we were able to observe changes in bandwidth, resonation, out-of-band rejection depending on the number and area of resonator.

  • PDF