• Title/Summary/Keyword: Equipment wear

Search Result 217, Processing Time 0.028 seconds

Investigation of Reinforced Distribution in Fabrication Process of Metal Matrix Composites by Combined Stirring Process (복합교반법에 의한 금속복합재료의 제조공정에 따른 강화재의 분산성 검토)

  • 이동건;강충길
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.1-11
    • /
    • 2001
  • The particulates reinforced metal matrix composites(PMMC) have a number of interesting mechanical properties. including high strength and good resistance to wear at high temperature and low thermal expansion. The equipment structure to obtain the homogeneous distribution in composites are proposed for the continuous pouring of reinforcement at the desired temperature. The particulates reinforced metal matrix composites(A357/SiCp) were fabricated by the process of the combined stirring method with the various fabrication process. The combined stirring method to niform distribution of particle is consisted of two stirring force both electro-magnetic stirring generated from induction heating and mechanical stirring with graphite stirrer. PMMC billets were fabricated with the volume fractions ranged from 0% to 20% and particle sizes ranged from 14${\mu}{\textrm}{m}$ to 25${\mu}{\textrm}{m}$. It is important to cont the size of primary $\alpha$-Al solid particles because it could become the cause of the particle pushing or capture phenomena from the fact that secondary dendrite arm spacing size depends on the cooling rate during the solidification in hypoeutectic Al-Si alloy. Therefore, the effect of primary $\alpha$-Al on the reinforcement distribution in matrix alloys has been investigated. The microstructure of PMMC fabracated with various volume fractions(0%, 10%, and 20%) and particle size were observed.

  • PDF

A Study of the Life Test of Hydraulic Pump Driving Gear Box for the Large Excavator (초대형 굴삭기용 유압펌프 구동 기어박스의 수명시험에 관한 연구)

  • Lee, Yong Bum
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.211-216
    • /
    • 2015
  • Large hydraulic excavator weighted 90 tons used the several pumps installed in parallel to use the hydraulic pump driving gearbox to improve fuel consumption by improving the energy efficiency of the hydraulic system. Gearbox connected to hydraulic pump supply the mechanical output to the high pressure and low pressure pump to be supplied by torque and rotation, which are the mechanical power, through a input shaft connected to large size engine of the excavator. So, gearbox connected to hydraulic pump is same as main artery in the human body and is required long life because it operates the hydraulic pump continuously during operating the engine. This study had used oil contamination analysis method to check the wear characteristics of the gearbox and frequency response characteristic analysis method to check the failure of the teeth failures of gearbox, while the test equipment adopted by the electrical feedback method to reduce the energy consumption was operating for the life assessment, in which the required power was 600 kW input power.

Assessment of Methylbromide Exposure Levels in Fumigation Workers on Import and Export Plant (수출입식물 훈증 작업자의 브롬화메틸 노출수준 평가)

  • Jeong, Jee Yeon;Yi, Gwang-Yong;Cho, Sook-Ja;Park, Seung-Hyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.1
    • /
    • pp.50-57
    • /
    • 2020
  • Objectives: Methyl bromide is a highly toxic substance that can cause systemic poisoning, neurotoxicity, pulmonary edema. Methyl bromide is a widespread fumigation agent used for import and export quarantine, but there is little data on exposure assessment of workers participating in such fumigation. Therefore, this study aims to investigate the exposure level of methyl bromide among workers and the concentration distribution of methyl bromide in the workplace during fumigation. Methods: For this study, one wood tent and one container fumigation area in Pusan, and one wood tent fumigation area in Incheon were investigated over three months from June 2001. Results: Methyl bromide exposure levels for container fumigation workers were from undetected to 1.86 ppm and from undetected to 2.28 ppm for tent fumigation workers as an 8 hr TWA. After opening the container door, the methyl bromide concentration in the container decreased rapidly over time, but the concentration remained over 1 ppm even after about one hour. The concentrations around the tent during its removal were highly affected by wind, but were detected in a range from undetected to 11.97 ppm. Conclusions: This study confirmed that both container and tent fumigation caused workers to exceed the exposure limit of 1 ppm as an 8 hour TWA. In particular, it could be confirmed that a situation exists in which the worker may be exposed to high concentrations of methyl bromide when opening the container or removing the tent due to the nature of the work. Therefore, it is very important to improve working methods and to wear appropriate personal protective equipment.

Medial Longitudinal Arch Balanced Analysis of the Calibration (종족궁 내측아치 지지에 따른 균형능력 분석)

  • Kim, Seonchil;Lim, Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.51-56
    • /
    • 2014
  • We analyzed how insole affects the dynamic stability and the balance while a body moves or stops. Specially we've sorted out variations of individual balance ability while we make a longitudinal arch stop artificially as a usual situation(just standing and putting one's weight). We found ten men and girls each with suitable feet for our experimentation as the subject of investigation and made individual insole for them by measuring medial longitudinal arch. Then we compared before and after movement of the power point of application and a pattern of COP using the Tetrax balance equipment. We found out it is better for balance ability when we wear insoles. It turned out to be helpful for increasing balance ability of body to use insole which supports medial longitudinal arch of longitudinal arch well.

A Study on the Wearing Conditions for Developing Police Raincoat with Advanced Work Efficiency (업무효율성이 향상된 경찰 우의 개발을 위한 경찰 우의 착의실태 조사)

  • Yu, Seung-min;Kim, Dong-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.40 no.5
    • /
    • pp.910-920
    • /
    • 2016
  • This study is to understand the problems of current police raincoats for professional policemen and conscripted policemen. Interviews and a survey were completed to investigate the wearing conditions of current police raincoats. The questionnaire was composed of questions on current wearing conditions of raincoat, motional adaptability, dimensional compatibility, design suitability and demographic information on the research target. The results indicated that the wearing frequency of raincoats had significant difference according to duty and age range. The main reason for the low wearing frequency was the uncomfortableness of working while wearing the raincoat, followed by the inconvenience of managing the raincoat after use and feeling hot while wearing the raincoat. The three most important factors when wearing a raincoat was pleasantness, activity capability and the functionality of the fabric. The satisfaction on body parts during motions tended to be evaluated lower as the raincoat size increased. The results of the dissatisfaction factors indicated that the raincoat hood had the most problems. There was inconvenience when using the equipment belt because officers have to wear their belts inside the raincoat. In regards to the fabric satisfaction level, respondents were less satisfied with ventilation, hygroscopicity, and drying time. Therefor it appeared that the current raincoat had problems due a lack of functionality in regards to ventilation, hygroscopicity, and quick drying; in addition, the satisfaction on motional adaptability had a significant difference according to raincoat size.

A Study on the Influence of Nonlinearity Coefficients in Air-Bearing Spindle Parametric Vibration

  • Chernopyatov, Y.A.;Lee, C.M.;Chung, W.J.;Dolotov, K.S.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.51-58
    • /
    • 2005
  • The development of the high-efficiency machine-tools equipment and new cutting tool materials with high hardness, heat- and wear-resistance has opened the way to application of high-speed cutting process. The basic argument of using of high-speed cutting processes is the reduction of time and the respective increase of machining productivity. In this sense, the spindle units may be regarded as one of the most important units, directly affecting many parameters of high-speed machining efficiency. One of the possible types of spindle units for high-speed cutting is the air-bearing type. In this paper, we propose the mathematical model of the dynamic behavior of the air-bearing spindle. To provide the high-level of speed capacity and spindle rotation accuracy we need the adequate model of "spindle-bearings" system. This model should consider characteristics of the interactions between system components and environment. To find the working characteristics of spindle unit we should derive the equations of spindle axis movement under the affecting factors, and solve these equations together with equations which describe the behavior of lubricant layer in bearing (bearing stiffness equations). In this paper, the three influence coefficients are introduced, which describe the center of spindle mass displacement, angle of shaft rotation around the axes under the unit force application and that under the unit torque application. These coefficients are operated in the system of differential equations, which describes the spindle axis spatial movement. This system is solved by Runge-Kutta method. Obtained trajectories and amplitude-frequency characteristics were then compared to experimental ones. The analysis shows good agreement between theoretical and experimental results, which confirms that the proposed model of air-bearing spindle is correctis correct

Analysis of Wearing Propensities, Wearing Comfort, Mobility of Movement, and 3D Shape for Advanced Baseball Leg Guards Design (야구 다리보호대 디자인을 위한 착용실태 및 착용감, 운동기능성, 3D 형태분석)

  • Lee, Hyojeong;Eom, Ran-I;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.39 no.1
    • /
    • pp.63-76
    • /
    • 2015
  • This study conducted a survey to gauge the buying and wearing propensities of wearers of leg guards made for baseball catchers, as well as product characteristics of preferred leg guards. Data from the survey were analyzed to obtain basic data for the development of an advanced leg guard design. Degree of compression, horizontal distance, cross section view and outline 3D sketch were also analyzed from the 3D data of leg guards; in addition, mobility and kinematic analysis were conducted through a wearing test. The survey indicated that imported products dominate the current retail market because they are appreciated by customers in terms of fit, price, brand, and protection. Representative complaints of products were discomfort, pressure, and the heavy-weight of the leg guards in general attributed to overall structure and 3D shape. When the pressure was lower on the front area of knee, it feels better to wear and the average knee angular velocity during the up and down motion increased, which suggests a better design from a kinematic point of view. The knee is the primary part of the body responsible for any movement of the lower limbs; consequently, the degree of compression and support stability of the leg guards near the knee area are important factors to evaluate the performance of leg guards. The results of our study indicate significant opportunities for improvement in product design and the development of baseball leg guards along with an ergonomic design that considers the mobility of the knee, skin deformations is necessary to improve performance. The process followed in this study will be applicable to studies on other personal protective equipment for sports.

Biomechanical Analysis at the Start of Bobsleigh Run in Preparation for the 2018 Pyeongchang Winter Olympics

  • Park, Seungbum;Lee, Kyungdeuk;Kim, Daewoong;Yoo, Junghyeon;Jung, Jaemin;Park, Kyunghwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.239-245
    • /
    • 2017
  • Objective: The bobsleigh shoes used in the start section are one of the most important equipment for improving the competition. Despite the importance of the start section, there are no shoes that are specific for bobsleigh athletes in Korea and Korean athletes have to wear sprint spike shoes and practice the start instead of wearing bobsleigh shoes. The objective of the present study was to provide data for improving the performance of Korean bobsleigh athletes by investigating the differences in their split time, plantar pressure, and forefoot bending angle based on skill levels at the start of a run under the same conditions as training conditions. Method: Six Korean bobsleigh athletes were divided into two groups, superior (n=3) and non-superior (n=3). A digital speedometer measured the split time at the start; the Pedar-X system (Novel, Germany) measured plantar pressure. Plantar pressures and split times were measured as the athletes pushed a bobsleigh and sprinted at full speed from the start line to the 10-m mark on the bobsleigh track. An ultra-high-speed camera was used to measure the forefoot bending angle during the start phase. Results: Significant between-group differences were found in split times (p<.000; superior = 2.38 s, non-superior = 2.52 s). The superior group had a larger rearfoot (p<.05) contact area, maximum rearfoot force (p<.01), and a larger change in angles 3 and 4 (p<.05). Conclusion: At the start of a bobsleigh run, proper use of the rearfoot for achieving effective driving force and increasing frictional resistance through a wider frictional force can shorten start time.

A Study on Image Quality and Exposure Dose of Hard-radiation Radiography of the Chest (흉부(胸部) 경선질촬영(硬線質撮影)에 있어서 피폭선양(被曝線量)의 저감(低減)에 관(關)한 연구(硏究))

  • Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakurai, Tatsuya;Kim, Chung-Woon;Hwang, Jong-Sun
    • Journal of radiological science and technology
    • /
    • v.14 no.2
    • /
    • pp.15-21
    • /
    • 1991
  • Experiment was conducted on the image quality and exposure dose following replacement of $CaWO_4$ system screen BH-III and BX-III which have so far been used for high-voltage hard-radiation quality radiography, with rare earth system screen KO750, combined with high contrast film SRH, while additional filter was altered, Cu 0.8 mm+Al 1.4 mm(HVL : Al 8.8 mm), Cu 1.3 mm+Al 1.0 mm(HVL : Al 10.6 mm) and Cu 1.8 mm+Al 1.5 mm(HVL : Al 11.4 mm). AS a result, visual evaluation did not detect extreme changes in image quality under the respective condition(HVL : $Al\;8.8\;mm{\sim}Al\;11.4\;mm$). It was noted, however, that surface exposure dose declined with an increase in the thickness of the additional filter, as it was $18.9\;{\mu}Gy$ at HVL Al 8.8 mm, $17.5\;{\mu}Gy$ at Al 10.6 mm and $15.7\;{\mu}Gy$ at Al 11.4 mm. Considering the limited rating of X-ray equipment and wear of machinery, however, the range of $Cu\;1.3\;mm{\sim}1.8\;mm+Al\;1.0\;mm{\sim}1.5\;mm(1/16\;VL{\sim}1/32\;VL)$ seemed to be a limit.

  • PDF

TLD dose variation of Magnetic Resonance Imaging Equipment (자기공명영상장비에서 열형광선량계의 선량 변화)

  • Je, Jaeyong;Kang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.473-476
    • /
    • 2012
  • The PET-MRI which has been installed and being managed recently uses both magnetic field and radiation. Most radiation workers wear a thermoluminescenct dosimeter (TLD) as a personal radiation dosimeter, and the TLD is affected both by a magnetic field and radiation. In this research, the same amount of X-ray was applied to 36 TLDs, and the changes in the dose of the 32 TLDs exposed to magnetic field at the location where its intensity of the magnetic resonance imaging (MRI) was about 5000 Gauss for eight hours with one-hour unit and that of the four TLDs not exposed to magnetic field were compared and checked. The measurement result showed that exposure dose of the TLD attached to the MRI changed irregularly depending on the amount of exposure time. Therefore, the TLD whose amount of changes little in the environment of a MRI is demanded to be developed.