• Title/Summary/Keyword: Equipment contamination

Search Result 198, Processing Time 0.028 seconds

Effects of Non-uniform Pollution on the AC Flashover Performance of Suspension Insulators

  • Zhijin, Zhang;Jiayao, Zhao;Donghong, Wei;Xingliang, Jiang
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.4
    • /
    • pp.961-968
    • /
    • 2016
  • The non-uniform distribution of contamination on insulator surface has appreciable effects on flashover voltage, and corresponding researches are valuable for the better selection of outdoor insulation. In this paper, two typical types of porcelain and glass insulators which are widely used in ac lines were taken as the research subjects, and their corrections of AC flashover voltage under non-uniform pollution were studied. Besides, their flashover characteristics under different ratio (T/B) of top to bottom surface salt deposit density (SDD) were investigated, including the analysis of flashover voltage, surface pollution layer conductivity and critical leakage current. Test results gave the modified formulas for predicting flashover voltage of the two samples, which can be directly applied in the transmission line design. Also, the analysis delivered that, the basic reason why the flashover voltage increases with the decrease of T/B, is due to the decrease of equivalent surface conductivity of the whole surface and the decrease of critical leakage current. This research will be of certain value in providing references for outdoor insulation selection, as well as in proposing more information for revealing pollution flashover mechanism.

Disinfection of various materials with 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride in hatchery facilities

  • Kim, Yu-Jin;Kim, Jun-Beom;Song, Chang-Seon;Nahm, Sang-Soep
    • Animal Bioscience
    • /
    • v.35 no.4
    • /
    • pp.631-637
    • /
    • 2022
  • Objective: Surface disinfection is important in the proper running of livestock farms. However, disinfection of farm equipment and facilities is difficult because they are made of different materials, besides having large surface areas and complex structures. 3-(trimethoxysilyl)-propyldimethyloctadecyl ammonium chloride (Si-QAC) is a quaternary ammonium salt-based disinfectant that attaches to various surfaces by forming covalent bonds and maintains its disinfecting capacity for a considerable time. Our aim was to evaluate the potential use of Si-QAC for disinfection of farm equipment and facilities. Methods: The short- and long-term antimicrobial and antiviral effects of Si-QAC were evaluated in both laboratory and farm settings using modified quantitative assessment method based on the standard operating procedures of the United States Environmental Protection Agency. Results: Si-QAC was highly effective in controlling the growth of the Newcastle disease virus and avian pathogenic Escherichia coli. Electron microscopy revealed that the mechanism underlying the disinfection activity of Si-QAC was associated with its ability to damage the outer membrane of the pathogen cells. In the field test, Si-QAC effectively reduced viral contamination of surfaces of equipment and space. Conclusion: Our results suggest that Si-QAC has great potential as an effective chemical for disinfecting farm equipment and facilities. This disinfectant could retain its disinfection ability longer than other commercial disinfectants and contribute to better farm biosecurity.

Microbial Contamination in a Facility for Processing of Fresh-Cut Leafy Vegetables (신선편이 채소류 가공작업장 내 시설 및 제품의 미생물 오염 실태)

  • Kim, Byeong-Sam;Lee, Hye-Ok;Kim, Ji-Young;Yoon, Doo-Hyun;Cha, Hwan-Soo;Kwon, Ki-Hyun
    • Food Science and Preservation
    • /
    • v.16 no.4
    • /
    • pp.573-578
    • /
    • 2009
  • Microbial contamination levels in a fresh-cut leafy vegetable processing plant were evaluated. Total plate counts of samples collected from the walls, equipment, and raw materials ranged from $10^1{\sim}10^2$ CFU/100 $cm^2$, $10^0{\sim}10^4$ CFU/100 $cm^2$, and $10^4{\sim}10^6$ CFU/g, respectively. No coliforms were detected on walls; however, equipment and raw materials contained coliforms in concentrations ranging from ND (not detected)to $10^2$ CFU/100 $cm^2$ and $10^4{\sim}10^5$ CFU/g, respectively. Additionally, total plate counts for falling and floating bacteria in the processing plant were $10^0{\sim}10^1$ CFU/plate and $10^1{\sim}10^3$ $CFU/m^3$, respectively. Pathogenic microorganisms such as Escherichia coli, Salmonella spp, Staphylococcus aureus, or Listeria monocytogenes were not detected on walls, equipment, or raw materials. Overall, the results of this study indicate that hygiene control in the fresh-cut processing plant should be improved.

Toxin Genes and Antibiotic Resistance of Food Poisoning Bacteria Isolated from Food Service Equipment in Childcare Centers (어린이집 급식설비에서 분리된 식중독 미생물의 독소 유전자 및 항생제 내성)

  • Eun-yeong Kim;Chae-Young Kim;Ji-Yu Im;Jung-Beom Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.3
    • /
    • pp.266-272
    • /
    • 2024
  • This study assessed the contamination level of food poisoning bacteria on handles of food service equipment in childcare centers to prevent food poisoning and analyzed toxin genes and antibiotic resistance of isolated strains. The isolates used in this study were collected from 101 childcare centers in Jeollanam-do. Four strains of Bacillus cereus and two strains of Staphylococcus aureus were isolated on the handles of food service equipment (refrigerators and freezers). The toxin genes of B. cereus were detected as nheA, nheB, nheC, entFM, and cytK. No toxin genes of S. aureus were detected. B. cereus showed resistance to β-lactam antibiotics, such as ampicillin and cefepime. S. aureus also showed resistance to antibiotics such as ampicillin and cefepime. Therefore, microbial safety and hygiene management, such as periodic sterilization of handles, should be strengthened to prevent food poisoning caused by cross-contamination of food service equipment handles in childcare centers.

Influence of Plasma Corrosion Resistance of Y2O3 Coated Parts by Cleaning Process (세정공정에 따른 Y2O3 코팅부품의 내플라즈마성 영향)

  • Kim, Minjoong;Shin, Jae-Soo;Yun, Ju-Young
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.365-370
    • /
    • 2021
  • In this research, we proceeded with research on plasma resistance of the cleaning process of APS(Atmospheric Plasma Spray)-Y2O3 coated parts used for semiconductor and display plasma process equipment. CF4, O2, and Ar mixed gas were used for the plasma environment, and respective alconox, surfactant, and piranha solution was used for the cleaning process. After APS-Y2O3 was exposed to CF4 plasma, the surface changed from Y2O3 to YF3 and a large amount of carbon was deposited. For this reason, the plasma corrosion resistance was lowered and contamination particles were generated. We performed a cleaning process to remove the defect-inducing surface YF3 layer and carbon layer. Among three cleaning solutions, the piranha cleaning process had the highest detergency and the alconox cleaning process had the lowest detergency. Such results could be confirmed through the etching amount, morphology, composition, and accumulated contamination particle analysis results. Piranha cleaning process showed the highest detergency, but due to the very large thickness reduction, the base metal was exposed and a large number of contaminated particles were generated. In contrast, the surfactant cleaning process exhibit excellent properties in terms of surface detergency, etching amount, and accumulated contamination particle analysis.

Design of Electrostatic Bonding Equipment for Large Area and the Effect of Contamination Particle on the Si-glass Electrostatic Bonding (대면적 정전 접합 장치 고안 및 Si과 Glass 접합에 미치는 불순물의 영향)

  • Mun, Je-Do
    • Korean Journal of Materials Research
    • /
    • v.6 no.1
    • /
    • pp.3-11
    • /
    • 1996
  • 대면적 정전 접합 장치를 고안 및 제작하여 Si과 glass를 정전 접합시켰다. 여러 온도에서 정전 접합 후 접합 면적을 측정하였으며 접합이 이루어진 경우 그 접합 면적이 90%를 넘었다. 접합시 전류를 측정하여 접합 강도와의 관계를 살펴보였다. 잔류 공공을 생성시키는 원인은 재료의 표면 거칠기 차이나 전극의 모양보다는 불순물 입자에 의한 것임이 밝혀졌고 같은 크기의 불순물 입자에 대한 공공의 크기는 접합 온도가 높을수록 감소하였다. 정전 접합에 미치는 불순물의 영향을 공공의 크기 및 불순물 입자의 크기를 측정하여 살펴보았다.

  • PDF

ROLE OF MEMBRANE MODULES IN ULTRAPURE WATER SYSTEM FOR THE CURRENT SEMICONDUCTORS INDUSTRIES

  • Iwahori, Hiroshi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1991.10a
    • /
    • pp.17-26
    • /
    • 1991
  • It can be said that the current ULSI technology has been supported and/or accomplished by a major challenge to the clean room environment and the ultrapure water equipment manufacturers as to contamination control. The required improvement in ultrapure water quality, which is shown in Figure 1, would not have been possible without significant improvements in membrane performance and enhancements in analytical capabilities.

  • PDF

Single Use (Disposable) Duodenoscope: Recent Development and Future

  • Kihyun Ryu;Sunguk Jang
    • Clinical Endoscopy
    • /
    • v.55 no.2
    • /
    • pp.191-196
    • /
    • 2022
  • Unlike simple forward-viewing endoscopes such as gastroscope or colonoscope, duodenoscope houses much more complex design to fulfil its function. This design differences leave duodenoscopes more prone to contamination from inadequate disinfection process and potential dissemination of pathogens. Recent reports on dissemination of infection through the duodenoscope mandated an overhaul of duodenoscope utilization including development of a disposable duodenoscope. This article reviews the current state of disposable duodenoscope development, including reported early efficacy as well as its future direction and utilization.

Research on Surface Contamination Analysis of Radiology Examination Equipment in Medical Institutions (의료기관 내 영상의학 검사 장비의 표면 오염도 분석 연구)

  • Shin-Woo Lee;Da-eun Kim;Chae-won Mun;Gap-Jung Kim;Sang-Ha Kim;Hye-mi Park;Se-Jong Yoo
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.171-177
    • /
    • 2024
  • In this study, two general X-ray device, CT, and MRI inspection devices were selected from general hospitals in the Daejeon area and an experiment was conducted to predict the level of infection by measuring the surface contamination of the inspection devices at different times and to use it as basic data for infection prevention. As a result, the surface contamination level by time zone for general X-ray devices and MRI examination devices was in the order of 13H > 8H > 16H, and for CT examination devices, it was 13H > 16H > 8H, which appeared to be influenced by the number of tests. In addition, the surface contamination results for each part of the test device showed that the highest ATP contamination value was found on the stand bucky handle for the general X-ray device, the headrest for the CT examination device, and the operation switch for the MRI examination device, which was closely related to the number of contacts. As a result of comparing before and after disinfection, all devices showed a significant decrease after disinfection. Based on the results of the experiment, it is believed that it can be used as basic data to identify the level of contamination in radiology laboratories and prevent infectious diseases.

Prevention of Oil Contamination in the Excitation System of a Power Plant Generator (발전용 발전기 여자설비의 오일 오염방지)

  • Choi, Jae-Gyu;Yoo, Ho-Seon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.7 no.2
    • /
    • pp.30-38
    • /
    • 2011
  • The purpose of this paper is to review the understanding of pollution causes in the excitation system and how to solve the problem. The cause of the problem was in-leakage of bearing lubricant oil through the gap between rotor and outer in the air deflector, which was triggered by a negative pressure with respect to the operation of a collector ring fan in the collector house. In order to prevent exciting current transmission equipment pollutant, the reduction of the negative gage pressure of the inside of collector house is required. The protection in-leakage of bearing lubricant oil through the gap between rotor and outer of the air deflector are necessary. The reduction of the inside diameter of air deflector and the expansion of inlet filter of collector house are inevitable.

  • PDF