• Title/Summary/Keyword: Equipment Reliability

Search Result 1,169, Processing Time 0.022 seconds

The Characteristics analysis of a Flux-lock Type Fault Current Limiter according to the Winding Directions for Power Grid (전력계통 적용을 위한 결선방향에 따른 자속구속형 한류기의 특성 분석)

  • Lee, Mi-Yong;Park, Jeong-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5879-5884
    • /
    • 2013
  • With the rapid industrialization and economical development, the electricity demands of the industrial facilities and densely populated large cities are continuing to increase in Korea. The increase in the power consumption requires the extension of power facilities, but it is difficult to secure spaces for equipment installation in the limited space of urban areas. In addition, the 154 kV or 345 kV transmission systems in Korea has a short transmission distance, and are connected to one another in network structures that ensure the high reliability and stability of power supply. This structure reduces the impedance during the fault in power system, and increases the magnitude of in the short circuit fault current. The superconducting fault current limiter (SFCL) was devised to effectively address these existing problems. The SFCL is a new-concept eco-friendly protective device that ensures fast operation and recovery time for the fault current and does not need additional fault detection devices. Therefore, many studies are being conducted around the world. In this paper, based on the wiring method the initial fault current characteristics, current limiting characteristics, according to the incident angle and the change in inductance current limiting characteristics were analyzed in a multifaceted methods.

Development of Current Limiting COS Fuse Link with Improved Overcurrent and Protection Coordination performance (과전류 차단과 보호협조 성능이 향상된 한류형 COS 퓨즈링크 개발)

  • Kim, Youn-Hyun;Kim, Young-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.129-136
    • /
    • 2020
  • A Cut Out Switch (COS) is used for line protection and pole transformer protection in power systems. The COS used to protect the pole transformer is installed on the power side of the pole transformer to protect the electric equipment from fault currents. The COS is composed largely of a body and a fuse holder, and when the fault current is energized, the element of the fuse link in the fuse holder is melted to block the fault current. The arc generated when the COS fuse link is blown causes fire and noise, causing discomfort to residents in the surrounding area, and the arc flame can cause secondary damage to the peripheral device. In this study, a current-limiting COS fuse with improved overcurrent blocking performance rather than explosion type was developed to solve the arc and noise problems during COS operation. The overcurrent breaking performance of the current-limiting COS improves the reliability by developing a striker and COS fuse bracket. In addition, this study aimed to verify the performance of the developed current-limiting COS fuse through a test at an authorized institution.

A Goodness of Fit and Validity Study of the Korean Radiological Technologists' Core Job Com petency Model (방사선사 핵심 직무역량 모델의 적합성 및 타당성 검증)

  • Lim, Chang-Seon;Cho, A Ra;Hur, Yera;Choi, Seong-Youl
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.469-484
    • /
    • 2017
  • Radiological Technologists deals with the life of a person which means professional competency is essential for the job. Nevertheless, there have been no studies in Korea that identified the job competence of radiologists. In order to define the core job competencies of Korean radiologists and to present the factor models, 147 questionnaires on job competency of radiology were analyzed using 'PASW Statistics Version 18.0' and 'AMOS Version 18.0'. The valid model consisted of five core job competencies ('Patient management', 'Health and safety', 'Operation of equipment', 'Procedures and management') and 17 sub - competencies. As a result of the factor analysis, the RMSEA value was 0.1 and the CFI, and TLI values were close to 0.9 in the measurement model of the five core job competencies. The validity analysis showed that the mean variance extraction was 0.5 or more and the conceptual reliability value was 0.7 or more, And there was a high correlation between subordinate competencies included in each subordinate competencies. The results of this study are expected to provide specific information necessary for the training and management of human resources centered on competence by clearly showing the job competence required for radiologists in Korea's health environment.

The Internal Quality Control for TEST 1, the Automatic Analyzer of Erythrocyte Sedimentation Rate (ESR 자동분석기를 이용한 내부정도관리방법)

  • Cho, Young Kuk;Sim, Hyun-Seol;Song, Woon Heung;Park, Quehn
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.239-244
    • /
    • 2004
  • Recently automatic equipment has been well popularized for the erythrocyte sedimentation rate, a widely used test, but no standard quality control has been established yet. Thus, we are going to report a case that established and applied a quality control method using the TEST 1 automatic analyzer. For internal quality control, we adopted the repeatability test through comparison with daily mean check, with a manual method using patients' specimens and with the results of a test on the previous day. In order to set the tolerance standard for each quality control method, we compared the results of 50 specimens that showed a wide range of ESR results and examined correlation and differences according to result. After setting the tolerance standard, we applied the standard at tertiary university hospitals for 120 days and investigated positive rates and re-examination rates. If the tolerance standard was exceeded, the cause was also identified. We selected a specimen of below 25 mm/hr (T1), one between 26-50 mm/hr (T2) and one of over 51 mm/hr (T3) at random. The correlation between the manual method and the automatic method was quite high (r=0.98), and it is found appropriate to set based on differences in result values below 25 mm/hr, the upper limit of the reference value, and based on differences in the percentage of result values above 25 mm/hr. Accordingly, we set the criteria for rejection above 10 mm/hr and above 20%. When the criteria were applied in the laboratory, 1.7% of specimens in the range of T1, 8.3% of those in the range of T2 and 7.5% of those in the range of T3 were rejected. Because all the rejected ones fell within the tolerance limit in re-examination calibration verification was not carried out. With the wide popularization of erythrocyte sedimentation rate analyzers that can carry out a lot of tests quickly using automatic methods, it is necessary to improve the reliability of test results by establishing internal quality control policies. We expect that an agreed standard quality control method may be established based on the method proposed in this study.

  • PDF

Intercomparison between Temperature and Humidity Sensors of Radiosonde by Different Manufacturers in the ESSAY (Experiment on Snow Storms At Yeongdong) Campaign (대설관측실험(Experiment on Snow Storms At Yeongdong: ESSAY) 기간 중 두 제조사 라디오존데 기온과 습도 센서 상호 비교)

  • Seo, Won-Seok;Eun, Seung-Hee;Kim, Byung-Gon;Seong, Dae-Kyeong;Lee, Gyu-Min;Jeon, Hye-Rim;Choi, Byoung-Cheol;Ko, A-reum;Chang, Ki-Ho;Yang, Seung-Gu
    • Atmosphere
    • /
    • v.26 no.2
    • /
    • pp.347-356
    • /
    • 2016
  • Radiosonde is an observation equipment that measures pressure (geopotential height), temperature, relative humidity and wind by being launched up from the ground. Radiosonde data which serves as an important element of weather forecast and research often causes a bias in a model output due to accuracy and sensitivity between the different manufacturers. Although Korean Meteorological Administration (KMA) and several institutes have conducted routine and intensive radiosonde observations, very few studies have been done before on the characteristics of radiosonde performance. Analyzing radiosonde observation data without proper understanding of the unique nature of those sensors may lead to a significant bias in the analysis of results. To evaluate performance and reliability of radiosonde, we analyzed the differences between two sensors made by the different manufacturers, which have been used in the campaign of Experiment on Snow Storm At Yeongdong (ESSAY). We improved a couple of methods to launch the balloon being attached with the sensors. Further we examined cloud-layer impacts on temperature and humidity differences for the analysis of both sensors' performance among various weather conditions, and also compared daytime and nighttime profiles to understand temporal dependence of meteorological sensors. The overall results showed that there are small but consistent biases in both temperature and humidity between different manufactured sensors, which could eventually secure reliable precisions of both sensors, irrespective of accuracy. This study would contribute to an improved sounding of atmospheric vertical states through development and improvement of the meteorological sensors.

Partial Discharge Characteristics and Localization of Void Defects in XLPE Cable (XLPE 케이블에서 보이드 결함의 부분방전 특성과 위치추정)

  • Park, Seo-Jun;Hwang, Seong-Cheol;Wang, Guoming;Kil, Gyung-Suk
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.2
    • /
    • pp.203-209
    • /
    • 2017
  • Research on condition monitoring and diagnosis of power facilities has been conducted to improve the safety and reliability of electric power supply. Although insulation diagnostic techniques for unit equipment such as gas-insulated switchgears and transformers have been developed rapidly, studies on monitoring of cables have only included aspects such as whether defects exist and partial discharge (PD) detection; other characteristics and features have not been discussed. Therefore, this paper dealt with PD characteristics against void sizes and positions, and with defect localization in XLPE cable. Four types of defects with different sizes and positions were simulated and PD pulses were detected using a high frequency current transformer (HFCT) with a frequency range of 150kHz~30MHz. The results showed that the apparent charge increased when the defect was adjacent to the conductor; the pulse count in the negative half of the applied voltage was about 20% higher than that in the positive half. In addition, the defect location was calculated by time-domain reflectometry (TDR) method, it was revealed that the defect could be localized with an error of less than1m in a 50m cable.

Behavior Evaluation of Aluminium oxide through Measurement of Mass Concentration under Laboratory Environment (연구실 환경에서의 질량농도 측정을 통한 Aluminium oxide의 거동 평가)

  • Park, Jeong-Hwa;Kim, Dong-Hyun;Kim, Jong-Kyu;Kim, Hyung-Sik;Kim, Jeong-Hun
    • Journal of Digital Convergence
    • /
    • v.14 no.3
    • /
    • pp.279-285
    • /
    • 2016
  • With the development of nanotechnology, the amount of nanomaterials increases and the problems of environment and the toxic property associated with it have become a social problem. But regulations and laws of nanomaterials have not yet been established. The purpose of this study is to utilize as the database of safety guidelines for research activities' workers associated with nanomaterials to conduct a behavior evaluation of aluminium oxide, which is most widely used in thirteen kinds of WPMN manufactured nanomaterials in the country. The experiment proceeds in the chamber reduced to 1/6 size of the actual laboratory, the test method was performed in NIOSH 0500. As the results of the study, the mass concentration was in inverse proportion to the particle size of the nanomaterials. And the mass concentration during the operation of ventilation equipment was reduced to about 1/8 times. In the future, it can be utilized as the database of safety guidelines for research activities' workers associated with nanomaterials. However, in order to increase the reliability of the study, the experiment of the mass concentration by particle size and Condensation Particle Counters will be needed additionally.

The Effects of Job Demand in Medical Estheticians on Expertise and Job Satisfaction: A Focus on the Manipulating Role of Job Resources (의료미용 종사자의 직무요구가 전문성 및 직무만족에 미치는 영향: 직무자원의 조절적 역할을 중심으로)

  • Shin, Hyang-Ran;Mo, Jeong-Hee
    • Journal of Digital Convergence
    • /
    • v.16 no.1
    • /
    • pp.453-461
    • /
    • 2018
  • As modern people's needs to be healthy and beautiful are increasing, medical skin care industry is growing both in quantity and quality. Therefore, this study investigated job demand and the moderating effect of job resource in employees who provided medical skin care services and the effects of job demand and job specialty on job satisfaction. The subjects of the study were medical estheticians in Gwangju City and Jeonnam Province and were interviewed with the use of a questionnaire. The data was analysed using SPSS 21.0 and a frequency analysis, a factor analysis, a reliability analysis, a correlation analysis were conducted and the results are presented as follows: The results are presented as follows: First, as for job demand, only cooperation had the moderating effect of job resource. Second, when the effect of job resources on medical skin care specialty was inspected, it was discovered that cooperation and equipment application had a positive effect on the specialty. Third, when the effect of job demand and specialty on job satisfaction was inspected, it was discovered that job tension had a negative effect on satisfaction and workload and specialty had a positive effect on satisfaction.

A case study on calibration of computational model for a reasonable cost estimation of missile development program (A case of guidance & control system of X missile) (유도무기 연구개발사업의 합리적인 비용 추정을 위한 전산모델 보정방안 사례 연구 (X 유도무기 유도조종장치 사례를 중심으로))

  • Park, Chung-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.5
    • /
    • pp.139-148
    • /
    • 2014
  • In recent years, computational models using parametric estimation method have been developed and used widely for efficient cost analysis. In this research, by applying experienced data from Guidance and Control Systems in Missile System field, the cost analysis for engineering model and commercial computational model(Price H, HL, M, S) are conducted and its result is analysed, so that the difference between two models and its grounds are apprehended. Comparing the calibrated value of computational model based on the data base of similar equipment and the cost from the engineering estimation, the two results are very close. It means that the credibility of data is enhanced through calibration. Also, for cost analysis of similar components in the future, the method for calibration of the computational models is also examined. When estimating development cost in this research, although many parts have been estimated through uncertain elements, the reliability could have been enhanced by applying computational model which secures objectivity. It is a very reasonable estimation method by utilizing calibration of the computational models based on existing accumulated development data.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.