• Title/Summary/Keyword: Equipment Reliability

Search Result 1,159, Processing Time 0.029 seconds

Optimum Redundant Design by Dynamic Programming (동적계획을 이용한 최적신뢰도 설계)

  • Park Tae-Hoon
    • Journal of the military operations research society of Korea
    • /
    • v.5 no.2
    • /
    • pp.73-80
    • /
    • 1979
  • In military applications of equipment, it is of the utmost importance that the equipment operates without breakdown for a specified length of time. We can increase the reliability of a system by adding redundant components to the basic nonredundant system. This study introduces a dynamic programming algorithm of finding optimum redundant design that maximizes the system reliability with constraints.

  • PDF

Development of the Expert System for Selection of Equipment for Automated Warehouses Using Reliability Theory (신뢰성 이론을 이용한 자동창고 설비 선정 전문가 시스템 개발에 관한 연구)

  • Lee, Young-Hae;Jeong, Chang-Sik
    • Asia pacific journal of information systems
    • /
    • v.8 no.3
    • /
    • pp.135-145
    • /
    • 1998
  • There exists popular approach using certainty factor (CF) for the development of effective reasoning mechanism under uncertainty in Expert System, However, there is a problem with CF. The CF values could be resulted in the opposite of given conditional probabilities. In this paper, a method for, reasoning under uncertainty using reliability theory to overcome the problem is proposed. And the proposed method is used in the development of Expert System for the selection of equipment for automated warehouses.

  • PDF

Development of Failure Reporting Analysis and Corrective Action System

  • Hong, Yeon-Woong
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.97-112
    • /
    • 2006
  • FRACAS(Failure Reporting, Analysis and Corrective Action System) is intended to provide management visibility and control for reliability and maintainability improvement of hardware and associated software by timely and disciplined utilization of failure and maintenance data to generate and implement effective corrective actions to prevent failure recurrence and to simplify or reduce the maintenance tasks. This process applies to acquisition for the design, development, fabrication, test, and operation or military systems, equipment, and associated computer programs. This paper shows the FRACAS development process and developed FRACAS system for a defense equipment.

  • PDF

Specification of Dependability Requirements (통합신뢰성 VOC 분석)

  • 김종걸;이낙영;권영일;홍연웅;전영록;나명환
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2001.06a
    • /
    • pp.267-268
    • /
    • 2001
  • We consider some guidance on specifying required dependability characteristics in product and equipment specifications, together with specifications of procedures and criteria for verification.

  • PDF

A Study on the Effect of Design Reliability and Periodic Inspection Cycle on Storage Reliability : Focusing on One-shot Logistic Equipment System (설계신뢰도 및 정기검사주기가 저장신뢰도에 미치는 영향에 관한 연구 : 일회성 군수장비 시스템을 대상으로)

  • Chu, Yeon-Won
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.7
    • /
    • pp.223-230
    • /
    • 2018
  • In the case of a one-shot logistic equipment system that has been stored for a long time, reliability changes with the passage of time. Therefore, when the time comes to use, the storage reliability of the product is an important quality characteristic, and the existing studies have focused on the research for calculating the optimal period inspection cycle to improve the storage reliability. In this study, we analyzed the influence of the two factors on the storage reliability at the convergence point by analyzing the design reliability as well as the periodic inspection cycle. To do this, we applied the existing Martinez storage reliability model to the missile, a representative product of a one-shot system, and analyzed the quantitative effects of the design reliability and the periodic inspection cycle. From the results of the analysis, it was confirmed that the maintenance of the periodic inspection cycle is more important for the improvement of the storage reliability than the design reliability in the design reliability category of the current product.

Test-Field Construction for Long-term Reliability of EHV Underground Transmission Cable (초고압 지중케이블 장기신뢰성 실증시험장 구축)

  • Kim, Jin;Kang, Ji-Won;Jang, Tae-In;Yang, Byeung-Mo;Park, Jun-Woo;Park, Hung-Sok;Yoon, Hyung-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.383_384
    • /
    • 2009
  • After the 1970s, the importance of underground transmission systems increased and the construction rate of underground transmission lines also showed increasing trends each year, especially in metropolitan areas. Accordingly the social ripple effects are very large and wide when the fault occurs in underground power system, and the amount of time and money spent to restore the system also increases. So we must ensure stable operation and long-term reliability of the facilities. In Korea's case, long-term reliability tests for EHV power cables and accessories progressed poorly because equipment was not compatible for long-term reliability tests. Therefore we planned to construct a long-term reliability test field for EHV underground cables in order to ensure international quality reliability and optimal power cable operation techniques. The Gochang Underground Cable Test Field is under construction, funded by the Korean government, the govenment's union investment department, KEPCO, KERI and three private cable corporations. This project began in March, 2005 and will be completed by February, 2010. It is designed to promote joint research by incorporating several types of test equipment, construction of operating facilities, and being an internationally certified authority.

  • PDF

Reliability Assesment of the Robotic System for Ultrasonic Inspection of Reactor Vessels (원자로 검사로봇의 신뢰도 분석)

  • 엄홍섭;이재철;김재희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.379-379
    • /
    • 2000
  • The robot systems used in nuclear power plants need to be both reliable and safe. As a part of the "Validation of nuclear safety-grade equipment" project, we established reliability analysis program and performed a number of analysis using conventional reliability analysis techniques. This paper describes the procedures, techniques, and results of the analysis utilized in our project. In addition, the paper includes current status of reliability analysis techniques and the summary of foreign case studiesse studies

  • PDF

Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test (적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가)

  • SeokTae Yoon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.21-27
    • /
    • 2023
  • Modern naval ships install an Infra-Red Signature Suppression system (IRSS) in their exhaust pipe to reduce infrared signature emitted to the outside. In addition, naval ships are strategic assets with a very long life cycle, so high reliability of the performance of the equipment on board must be guaranteed. Therefore, equipment such as IRSS is evaluated for performance through model testing at the design stage. A variety of measuring instruments are used in IRSS model testing, and the reliability of these instruments must also be guaranteed. In this paper, a study was conducted to evaluate the reliability of measurement equipment used in IRSS model testing. The test equipment and instruments used were a hot gas wind tunnel, pitot tube, digital differential pressure gauge, thermocouple sensor, and digital recorder. As the fan speed of the hot gas wind tunnel increased, the measurement deviation of the flow decreased, and the temperature output of the thermocouple sensor showed differences in response time and stability depending on the method used.