• Title/Summary/Keyword: Equipment / Facility

Search Result 824, Processing Time 0.026 seconds

A Study on the Method to Avoid the Gas Group IIC Equipment of Explosion Proof Electrical Equipment Adjacent to the Source of Release of Hydrogen Handling Facility (수소 취급설비의 누출원에 인접한 방폭전기기기의 가스그룹 IIC 기기 회피 방안에 관한 연구)

  • BYUN, YOON SUP
    • Journal of Hydrogen and New Energy
    • /
    • v.33 no.4
    • /
    • pp.383-390
    • /
    • 2022
  • Appropriate explosion proof electrical equipment should be installed in hazardous areas. In areas where hydrogen is handled, explosion proof electrical equipment adjacent to the hydrogen handing facility must be reviewed for selection of gas group IIC (or IIB+H2) equipment. When selecting explosion proof electrical equipment for the flammable substance handling facility in areas where hydrogen and flammable substance are handled, the method to avoid gas group IIC (or IIB+H2) equipment has been suggested by using the operating pressure of the hydrogen handling facility. When the operating pressure of the outdoor hydrogen handling facility is 1.065 MPa or less, it has been confirmed that there is no need to install gas group IIC (or IIB+H2) equipment for the flammable substance handling facility adjacent to the hydrogen handling facility. And the method of selecting explosion proof electrical equipment for the flammable substance handling facility has been suggested as a flowchart, so it will be able to be utilized when selecting appropriate explosion proof electrical equipment.

Standard Classification System of Marine Research Facility and Equipment for an Integrated Management (통합관리를 위한 해양연구시설·장비 표준분류체계)

  • RHO, TAEKEUN
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.25 no.4
    • /
    • pp.132-159
    • /
    • 2020
  • As multidisciplinary marine research is actively conducted, various types of marine research facilities and equipment are purchased every year. However, among marine research facilities and equipment, it is difficult to classify and manage various types of field observation equipment used for environmental data collection and sample collection under the current national research facility and equipment standard classification system. In the case of Korea Institute of Ocean Science and Technology, about 30% of research facilities and equipment are unclassified and not properly managed. In this study, marine research facilities and equipment are classified into 7 middle and 36 sub-classes according to their characteristics. It is proposed to add a large classification group called 'Environmental Observation/Analysis Equipment', to the national research facility equipment standard classification system. In addition, it is proposed to classify the equipment operated in the laboratory among marine research facilities and equipment according to the existing national research facility equipment standard classification system. Through this, it is expected that all of Korea's marine-related research facilities and equipment can be systematically classified and managed effectively.

A study on optimal of block facility layout using Hybrid GA (Hybrid GA를 이용한 최적의 블록단위 설비배치에 관한 연구)

  • 이용욱;석상문;이철영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2000.11a
    • /
    • pp.131-142
    • /
    • 2000
  • Facility layout is the early stage of system design that requires a mid-term or long-term plan. Since improper facility layout might incur substantial logistics cost including material handling and re-installment costs, due consideration must be given to decisions on facility layout. Facility layout is concerned with low to arrange equipment necessary for production in a given space. Its objective is to minimize the sum of all the products of each equipment's amount of flow multiplied by distance. Facility layout also is related to the issue of NP-complete, i.e., calculated amounts exponentially increase with the increase of the number of equipment. This study discusses Hybrid GA developed, as an algorithm for facility layout, to solve the above-mentioned problems. The algorithm, which is designed to efficiently place equipment, automatically produces a horizontal passageway by the block, if a designer provides the width and length of the space to be handled. In addition, this study demonstrates the validity of the Algorithm by comparing with existing algorithms that have been developed. We present a Hybrid GA approach to the facility layout problem that improves on existing work in terms of solution quality and method. Experimental results show that the proposed algorithm is able to produce better solution quality and more practical layouts than the ones obtained by applying existing algorithms.

  • PDF

A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building (건축 설비기기 소음의 특성 및 평가에 관한 연구)

  • Byun, Woon-Seob;Choi, Dool;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

A Study on Management System for Improving of Equipment Productivity in Injection Machining Process (사출가공공정에서 설비생산성 향상을 위한 관리체계에 대한 연구)

  • Park, Jun-Byung;Bae, Young-Ju
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.219-226
    • /
    • 2017
  • This study investigates application cases of facility management system model for enhancing facility productivity of industry filed around medium and small facility processing companies and finds the inefficiency of the existing management model. Following items are researched to seek out methods and measures to maximize facility productivity through empirical analysis by exploring and establishing a new management model. First, the empirical analysis, it is found that the overall equipment efficiency index used for facility productivity management in the companies has a difficulty being used as the index for it in actual medium-small processing companies. Second, a new facility management system model applying standard cycle time is suggested among facility management index system to measure facility productivity. Third, the empirical analysis is used to verify that developed facility management system model is a useful method to manage the facility productivity by applying the model to actual medium-small processing companies. Finally, it is necessary to implement comparison analysis on whether actual productivity enhancement induces a distinctly different result by using a new facility management index system model to be inhibited in this study.

Developing an On-line Scheduling System for Increasing Effectiveness of Public Research Facility (공공기관 연구시설장비 효율성 향상을 위한 온라인 일정계획 시스템 개발)

  • Lee, Chae-Yun;Kim, Ki-Hong;Shin, Seung-Jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.1
    • /
    • pp.181-189
    • /
    • 2017
  • The systematic management of technology infrastructure increasingly becomes critical as it represents the driving power for creating competitive advantage of nations and enterprises. In this sense, public facility and equipment, which is one major asset of technology infrastructure, should be managed effectively, systematically and efficiently to increase its overall equipment effectiveness. However, the manual and off-line communication was the unique way to communicate between the suppliers who provide facilities in the public sector and the customers who utilize the facilities in the industrial sector. This communication way caused invisibility of available usage time and increase of idle time, thereby decreasing the equipment effectiveness. This paper presents an web-based scheduling system that enables real-time collaboration and information sharing for increasing the equipment effectiveness. The designed system performs scheduling, facility management, order management and customer relationship management in an on-line platform, and carries out the processing and storing of relevant information in an integrated database. The paper includes a development approach to identify business process models and standardized system models by using object-modeling technique. The deliverable of the present work will contribute to increasing the equipment effectiveness by enhancing visibility, transparency and predictability by means of the integration with a legacy Enterprise Resource Planning.

A Study on Design Technologies for Sustainable Army Barracks (친환경 병영시설 모델개발을 위한 설계요소 분석)

  • Park, Chan-Hyuk;Cho, Woo-Suk;Kang, Youn-Do;Kim, Byung-Seon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.256-262
    • /
    • 2009
  • Purpose of this study is embody the environmental-friendly military facility model that applied renewable energy, passive design method and high efficiency equipment. In the introduction of this study, defined problem of existing military facility and classification of military facility are performed. Also, environmental friendly military facility is defined through classified by scale and building equipment method. In the renewable energy chapter, photovoltaic system and wind turbine system are considered And then, LED light, photovoltaic panel, motor, inverter are analyzed in the high efficiency equipment chapter.

  • PDF

Facility Layout Planning for the Safety 7th Curriculum of Technology Laboratory in a Middle School (제7차 교육과정을 고려한 중학교(中學校) 기술실(技術室)의 안전.시설.설비(安全.施設.設備) 배치(配置) 계획(計劃))

  • Kim, Jong-Bok;Lee, Sang-Hyuk
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.10 no.3
    • /
    • pp.15-26
    • /
    • 2003
  • The purpose of this study is to describe the planning and applied safety facility layout for a technology laboratory in a middle school. A technological teaching facility has its essential purpose in meeting students' needs and achieving educational objectives efficiently and effectively. Practice-related appliances were selected through investigation of the current middle school laboratory, and analysis of the technology textbooks of the 7th curriculum. Laboratory layout was achieved with consideration of the teacher's and students need of safety and close proximity to laboratory facilities and equipment. Our recommendation takes the SLP survey results into consideration. The results of this study are as follows: The following floor plan is recommended. The facility layout will insure that students are able to work safely, in full view of academic instructors. Students will have easy access to all equipment due to the efficient floor plan and logical sequencing of equipment.

Anomaly Detection System in Mechanical Facility Equipment: Using Long Short-Term Memory Variational Autoencoder (LSTM-VAE를 활용한 기계시설물 장치의 이상 탐지 시스템)

  • Seo, Jaehong;Park, Junsung;Yoo, Joonwoo;Park, Heejun
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.4
    • /
    • pp.581-594
    • /
    • 2021
  • Purpose: The purpose of this study is to compare machine learning models for anomaly detection of mechanical facility equipment and suggest an anomaly detection system for mechanical facility equipment in subway stations. It helps to predict failures and plan the maintenance of facility. Ultimately it aims to improve the quality of facility equipment. Methods: The data collected from Daejeon Metropolitan Rapid Transit Corporation was used in this experiment. The experiment was performed using Python, Scikit-learn, tensorflow 2.0 for preprocessing and machine learning. Also it was conducted in two failure states of the equipment. We compared and analyzed five unsupervised machine learning models focused on model Long Short-Term Memory Variational Autoencoder(LSTM-VAE). Results: In both experiments, change in vibration and current data was observed when there is a defect. When the rotating body failure was happened, the magnitude of vibration has increased but current has decreased. In situation of axis alignment failure, both of vibration and current have increased. In addition, model LSTM-VAE showed superior accuracy than the other four base-line models. Conclusion: According to the results, model LSTM-VAE showed outstanding performance with more than 97% of accuracy in the experiments. Thus, the quality of mechanical facility equipment will be improved if the proposed anomaly detection system is established with this model used.

Analysis of earthquake countermeasure for electrical facility at building (건축물에 시설되는 수변전설비의 지진 대책에 대한 조사 분석)

  • Kim, Gi-Hyun;Lee, Sang-Ick;Jean, Hyun-Jae;Bae, Suk-Myong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.359-362
    • /
    • 2008
  • Middle domestic the occurrence size which stews recently from the Korean Peninsula circumference country is augmenting on a large scale about earthquake about safe countermeasure part from the existing Natural Countermeasure Law 2008. Refers with the Earthquake Disaster Countermeasure Law to be new standard contents establishment by law and strengthened in March. Consequently the research is propelled about electric equipment earthquake-proof plan and countermeasure. The present paper investigated an equipment by domestic facility present condition about the change disappointment electric equipment which can supply all the member in the building an investigation analysis about problem point and improvement fact. Also about overseas electric equipment investigated about earthquake-proof plan relation system and facility present condition. Investigated the electric equipment earthquake-proof plan pertinent data which is advanced from like this existing nation and the equipment and application direction must apply to domestic presented. With character presents following the guide about electric equipment earthquake-proof plan becomes feed with the fact that will be able to use.

  • PDF