• Title/Summary/Keyword: Epoxy paint

Search Result 53, Processing Time 0.023 seconds

An Electrochemical Evaluation on the Corrosion Resistance of Heavy Anticorrosive Paint(II) (중방식 도료의 내식성에 관한 전기 화학적 평가(II))

  • Sung, Ho-Jin;Kim, Jin-Kyung;Lee, Myung-Hoon;Kim, Ki-Joon;Moon, Kyung-Man
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.382-387
    • /
    • 2005
  • An electrochemical evaluation on the corrosion resistance for heavy anticorrosive paint was carried out for 5 kinds of heavy anticorrosive paints such as High solid epoxy(HE), Solvent epoxy(SE), Tar epoxy(TE), Phenol epoxy(PE), and Ceramic epoxy(CE) as parameters of DFT(Dry Film Thickness, 25${\mu}m$50${\mu}m$, solution condition(Flow of Nonflow). Corrosion current density of HE(DFT 50${\mu}m$ in case of flow condition was larger than that of nonflow condition. However, their values of the other anticorrosive paints were decreased compared to the nonflow condition. The values of AC impedance were increased with increasing of DFT regardless of kinds of anticorrosive paints. And the polarization resistance of cyclic voltammogram showed a good tendency to correspond with well the values of AC impedance measurement. HE and CE had a relatively good corrosion resistance than other heavy anticorrosive paint.

  • PDF

Development of Paint-type and Spray-type Electromagnetic Wave Absorbers

  • Song Jae-Man;Kim Dong-Ii;Choi Jeung-Hyun;Jeung Jae-Hyun;Kim Ki-Man
    • Journal of electromagnetic engineering and science
    • /
    • v.5 no.4
    • /
    • pp.172-175
    • /
    • 2005
  • Sometimes, it is more convenient to use paint-type and spray-type EM wave absorbers than bulk-type or sheet-type. Thus, in this paper, we prepared paint-type and spry-type EM wave absorbers. The proportion of ferrites to paints, particle size of magnetic material, and kinds of paint should be considered to prepare a superior paint-type EM wave absorber. There is no big gap between spray-type and paint-type in EM wave absorption of EM wave absorbers prepared with same composition.

Study on the Physical Properties by Combining Epoxy and Acryl Electrodeposition Paints (에폭시와 아크릴 전착도료의 혼용성에 따른 물성 변화 연구)

  • Jung, Sung Soo;Yi, Dong Uk;Kim, Dong Won;Kim, Myung Hwan;Kwag, Sam Tag;Moon, Myung Jun
    • Journal of the Korean institute of surface engineering
    • /
    • v.47 no.3
    • /
    • pp.137-146
    • /
    • 2014
  • The important drawback of epoxy electrodeposition(ED) coatings is the lack of the weathering resistance caused by the structure of bisphenol A. To improve this yellowing phenomena, acryl ED coatings have been developed. Compared with the epoxy ED coatings, however, acryl ED coatings are relatively weak in the corrosion resistance and mechanical properties. The purpose of this study is complemented their drawbacks by mixing epoxy and acryl ED paints. The salt spray, accelerated weathering test(QUV) and cupping, bending, impact test were employed to investigate the corrosion resistance, weathering resistance, and mechanical properties of ED coatings. When the ratio of acryl to epoxy resin of ED coating is 0.33, the weathering resistances are appropriately improved in condition maintaining the corrosion resistance. It was shown that the weathering resistance for epoxy ED coating was adjusted by optimally mixing acryl ED paint.

A Study on Relationship between Corrosion Characteristics and Salt Concentration of Anti-corrosive Paint (방청도료의 부식특성과 염분농도의 상관관계에 관한 연구)

  • Moon, Kyung-Man;Lee, Myeong-Woo;Lee, Myeong-Hoon;Kim, Hye-Min;Baek, Tae-Sil
    • Journal of the Korean institute of surface engineering
    • /
    • v.51 no.2
    • /
    • pp.95-103
    • /
    • 2018
  • Recently, many types of constructional steels have been often exposed to under severe corrosive environments due to acid rain with increasing environmental contamination. In order to inhibit their corrosion in severe corrosive environments, a painting method has been widely applied to numerous constructional steels of land as well as marine. Therefore, development of paint having a good quality of corrosion resistance is considered to be very important. In this study, four types of anti-corrosive paints (AP: Phenol epoxy, AC: Ceramic epoxy, AT: Coal tar epoxy, AH: High solid epoxy) were coated to the specimens, and then, were immerged in various salt solutions (0.1, 0.3, 3, 6, 9 and 15% NaCl solutions) for 11 days. And, the corrosion resistance of these samples by effect of osmotic pressure with salt concentration was investigated with electrochemical methods such as measurement of corrosion potential, impedance and corrosion current density. The corrosion current densities of all samples (AC, AT and AH) submerged in 3% NaCl solution exhibited the smallest values compared to other salt solutions. However, in the case of lower values of salt solutions than 3% NaCl solution, the corrosion current density increased again because it makes easier for water, dissolved oxygen and chloride ion etc. to invade toward inner side of coating film due to increasing of the osmotic pressure than 3% NaCl solution, but in the case of higher values of salt solutions than 3% NaCl solution, the coating film is easily deteriorated due to high concentration of chloride ion rather than the osmotic pressure, which resulted in increasing the corrosion current density. In particular, the AC sample indicated the best corrosion resistance in 6% NaCl solution compared to other samples. Consequently, it is considered that the corrosion mechanism of the coated steel plate is completely different from bare steel plate, and the corrosion resistance of coating film by osmotic pressure and chloride ion depend on various types of epoxy of paint in NaCl solution.

Performance Appraisal of the Ceramic Metal Resin Paints for Waterproof and Anti-Corrosion to Improve the Property of Concrete Structure (콘크리트 구조물의 표층부 내구성 증진을 위한 세라믹 메탈계 방수$\cdot$방식재 도료의 성능 평가 연구)

  • Jun Byung-Hun;Kim Jin-Sung;Kang Hyo-Jin;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.113-117
    • /
    • 2005
  • The ceramic metal resin paints for waterproof and anti corrosion is not long history in development of materials even many actual result. So far, no standard have been given to construction and maintenance method, Quality and property, it is real state that cannot afford to proper quality control in job site or production. This study has been test for the ceramic metal resin paints for water and anti corrosion, as the result, it have proper performance of job site and mechanical performance of compare to other existing. In particular, tensile strength indicates more high about $14.1N/mm^2$ than epoxy resin paints, and in elongation per unit length is more high It is shows having better adhesive strength than epoxy resin paint for crack on the concrete structure. Moreover, The ceramic metal paint for water and corrosion proofing have to have main performance is watertightness and resistance for external impact, chloride ion permeation, drinkable water elution.

  • PDF

Dispersion Characteristics of Surface-Modified Graphene Nanoplate in Organic Solvent for Development of Graphene / Epoxy Paint to Protect Concrete (콘크리트 보호용 그래핀/에폭시 도료개발을 위해 표면개질한 그래핀 나노플레이트의 유기용매 분산특성)

  • Seo, Won-Woo;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Sang-Kyu;Hwang, Eui Chul;Son, Min-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.244-245
    • /
    • 2017
  • This study aims to develop high durability graphene / epoxy paint for durability improvement of construction structure. For the development of graphene / epoxy coatings, first, graphene must remain stable in the polymer. Second, the integrity of graphene and polymer should be ensured. Accordingly, in order to obtain dispersibility, surface modification of graphene nanoplate(GnP) with CH and COOH functional groups and its dispersibility in organic solvents were investigated. Also, Fourier Transform Infrared Spectroscopy(FT-IR) analysis and Atomic Force Microscope(AFM) analysis were performed to confirm whether the functional groups were synthesized by surface modification. As a result, FT-IR and AFM analysis did not confirm the surface modification, but GnP was found to be stable when dispersed in an organic solvent.

  • PDF

A Study on the Fluoro-polymer Composite Coatings for Protecting the Corrosion of Fossil-fuel Power Plants

  • Kang, Min Soo;Lee, Byung Seung;Chang, Hyun Young;Jin, Tae Eun;So, Il Soo
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.62-67
    • /
    • 2007
  • Several heavy duty coatings at an every kind industry facilities to various systems currently have been applied review to the many industry fields. Corrosion-protective characteristics in the case of novolac epoxy among them and unsaturated polyester have been applied most widely. epoxy and flake heavy duty coatings are applied for such reason in an every kind facilities(stack, FGD, cooler, chemical tank etc) of a fossil-fuel power plants Cases of the fossil-fuel power plants are exposed to more severe corrosion environment compared with other facilities and It is difficult to display the performance of long-term method at apply to be the partial. Our study shows fluoro-polymer composite coating method to overcome of the limit. The comparison did previous method and heavy duty coating about FGD plants most at a corrosion environment among fossil-fuel power plants. Additionally, other facilities examined different heavy duty method. The design mode of fluoro-polymer composite coating according to an every kind facilities show extensive methods that are characteristic revelation of film(top, middle and primer layer) composition of the paint, film thickness in accordance with a facilities corrosion and the corrosion protective effectiveness to come into being use fluoro-polymer composite with heavy duty paint(epoxy).

Mechanical Properties of Epoxy Paints Containing Oxidized Graphene Nanoplatelet (산화 그래핀 나노플레이트릿을 혼입한 에폭시 도료의 역학적 특성)

  • Seo, Won-Woo;Kim, Gyu-Yong;Yoon, Min-Ho;Hwang, Eui Chul;Baek, Jae Uk;Nam, Jeong Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.153-154
    • /
    • 2017
  • Graphene is a nanomaterial and is known to have very high mechanical strength, thermal and electrical properties. However, graphene is known to be difficult to disperse among carbon-based materials due to van der Waals force. In this study, to solve the dispersion problem of graphene nanoplatelet, oxidized graphene nanoplatelet was prepared by oxidizing GNP in nitric acid. The prepared GO was dispersed in ethanol and distilled water before incorporation into the epoxy paint to confirm dispersibility. In addition, GNP/Epoxy and GO/Epoxy tensile specimens were prepared by mixing GNP and GO at 0.1, 0.3, 0.5 and 1.0 wt.% In epoxy coatings and tensile stress-strain characteristics were investigated.

  • PDF

A Study on Impact Monitoring Using a Piezoelectric Paint Sensor (압전 페인트 센서를 활용한 충격 모니터링 활용 방안)

  • Choi, Kyungwho;Kang, Donghoon;Park, Seung-Bok;Kang, Lae-Hyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.5
    • /
    • pp.349-357
    • /
    • 2015
  • The piezoelectric paint sensor is a paint type sensor comprising of an epoxy and piezoelectric powder, which is the main component of a piezoelectric material. This sensor can be easily attached to any type of structure as compared to other sensors because it is viable to directly apply it on structures, as in the case with a typical paint. In this study, the capability of piezoelectric paint sensor for impact detection was evaluated. In Particular, the applications of the piezoelectric paint sensor for railroad vehicles were considered. There have been various cases reported about the damages caused by flying gravel to the under-cover of the railroad vehicle during operation. In order to prevent this, real-time monitoring of the large under-cover surface of the railroad vehicle is unavoidable. Under the assumption of vehicle application, sensor sensitivities were measured after multiple and prolonged exposure to thermal cycle environment $-20{\sim}60^{\circ}C$). Sensitivity evaluation of paint sensor under environmental conditions was conducted in an aluminum specimen. In results, despite the small variations in sensitivity, we could confirm the applicability of this paint sensor for impact detection even after a severe environmental exposure test.

Evaluation of Corrosion Resistance of Anti-Corrosive Paint by Investigation of Diffusion Limiting Current Density (확산한계전류밀도 고찰에 의한 방청도료의 내식성평가)

  • Moon, Kyung-Man;Kim, Yun-Hae;Lee, Myung-Hoon;Lee, In-Won;Park, Hyun;Chun, Ho-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.64-68
    • /
    • 2009
  • It has been observed that coated steel structures deteriorate more rapidly than the designed lifetime due to acid rain caused by air pollution, etc. Therefore, improving the corrosion resistance of anti-corrosive paint is very important in terms of safety and the economic point of view. In this study, the corrosion resistance of five kinds of anti-corrosive paints, including the Acryl, Fluorine, and Epoxy resin series, were investigated with electrochemical methods, such as corrosion potential measurements, polarization curves, diffusion limiting current density, etc. As a result, the corrosion resistance of the F101 specimen with the fluorine resin series was found to be superior to the other specimens, while E100 with the epoxy resin series also showed a somewhat good corrosion resistance. Furthermore, it was observed that the amount of water and oxygen entering the inner side of a painted film increased with an increase in immersion time, irrespective of the kind of resin series. However, the oxygen diffusion limiting current density of a specimen with good corrosion resistance was relatively decreased compared to other specimens, because of the difficulty of oxygen diffusion penetrating to the inner side of the film. Consequently it is suggested that we can qualitatively evaluate the corrosion resistance of an anti-corrosive paint by measuring the diffusion limiting current density as an electrochemical method.