• 제목/요약/키워드: Enzyme-linked immunosorbent assay

검색결과 1,110건 처리시간 0.028초

Development of an Enzyme-Linked Immunosorbent Assay for the Organophosphorus Fungicide Tolclofos-methyl

  • Park, Kyung-Yi;Park, Won-Chul;Kim, Yoo-Jung;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권3호
    • /
    • pp.334-338
    • /
    • 2003
  • A simple synthetic method for haptens of organophosphorus (OP) pesticides with a spacer arm (aminocarboxylic acid) attached at the pesticide thiophosphate group was developed and was applied to the synthesis of haptens for the OP fungicide tolclofos-methyl. Using the haptens, a selective enzyme-linked immunosorbent assay (ELISA) for tolclofos-methyl was developed. One of the haptens was coupled to BSA to use as an immunogen. Rabbits were immunized with this conjugate to obtain polyclonal antibodies to tolclofos-methyl. The antisera were screened against another hapten coupled to ovalbumin (OVA). Using the serum with highest specificity, an antigen-coated ELISA was developed, which showed an $IC_{50}$ of 160 ng/mL with the detection limit of 20 ng/mL. The antibodies showed negligible cross-reactivity with other OP pesticides. An antibody-coated ELISA was also developed, which showed an $IC_{50}$ of 410 ng/mL with a detection limit of 130 ng/mL.

돼지에서 분리한 Staphylococcus hyicus subsp hyicus의 protein A (Protein A of Staphylococcus hyicus subsp hyicus isolated from pigs)

  • 김도경;여상건
    • 대한수의학회지
    • /
    • 제30권2호
    • /
    • pp.187-192
    • /
    • 1990
  • 돼지로부터 분리한 Staphylococcus hyicus subsp hyicus 489주의 protein A 존재여부와 함량을 indirect hemagglutination 및 enzyme-linked immunosorbent assay(ELISA)법으로 조사하였다. Indirect hemagglutination text에 의하여 cell-bound protein A 및 extracellular protein A 보유균은 489주 중 각각 87.7% 및 36.0%로 나타났다. ELISA법에 의한 이들 균의 protein A함량 측정에서 전균주의 extracellular protein A는 1ng/ml미만이었으며, cell-bound protein A함량은 대부분의 균주에서 1ng/ml 미만이었고 11주가 25~108ng/ml 수준이었다.

  • PDF

Diagnosis of Cylindrocarpon destructans Using Enzyme-Linked Immunosorbent Assay

  • Li, Taiying;Ji, Sungyeon;Jung, Boknam;Kim, Bo Yeon;Lee, Kwang Sik;Seo, Mun Won;Lee, Sung Woo;Lee, Jungkwan;Lee, Seung-Ho
    • 식물병연구
    • /
    • 제25권3호
    • /
    • pp.131-135
    • /
    • 2019
  • Cylindrocarpon destructans causes ginseng root rot and produces radicicol that has an antifungal effect. In this study, we developed a method to detect this fungus using enzyme-linked immunosorbent assay (ELISA). Secreted proteins of C. destructans were used as antigens to obtain C. destructans-specific IgG from mouse. Out of 318 monoclonal antibodies generated from mouse, two antibodies (Cd7-2-2 and Cd7-2-10) showed highest specificity and sensitivity. Indirect ELISA using both antigens successfully detected C. destructans in soils, but direct ELISA using IgG conjugated with horseradish peroxidase failed to detect antigens in soils. The indirect ELISA developed here can efficiently detect the fungus and help manage ginseng root rot disease in fields.

A Highly Sensitive Indirect Enzyme-Linked Immunosorbent Assay (ELISA) Based on a Monoclonal Antibody Specific to Thermal Stable-Soluble Protein in Pork Fat for the Rapid Detection of Pork Fat Adulterated in Heat-Processed Beef Meatballs

  • Sol-A Kim;Jeong-Eun Lee;Dong-Hyun Kim;Song-min Lee;Hee-Kyeong Yang;Won-Bo Shim
    • 한국축산식품학회지
    • /
    • 제43권6호
    • /
    • pp.989-1001
    • /
    • 2023
  • Processed foods containing pork fat tissue to improve flavor and gain economic benefit may cause severe issues for Muslims, Jews, and vegetarians. This study aimed to develop an indirect enzyme-linked immunosorbent assay (iELISA) based on a monoclonal antibody specific to thermal stable-soluble protein in pork fat tissue and apply it to detect pork fat tissue in heat-processed (autoclave, steam, roast, and fry) beef meatballs. To develop a sensitive iELISA, the optimal sample pre-cooking time, coating conditions, primary and secondary dilution time, and various buffer systems were tested. The change in the iELISA sensitivity with different 96-well microtiter microplates was confirmed. The detection limit of iELISA performed with an appropriate microplate was 0.015% (w/w) pork fat in raw and heat-treated beef. No cross-reactions to other meats or fats were shown. These results mean that the iELISA can be used as an analytical method to detect trace amounts of pork fat mixed in beef.

Development of an Enzyme-Linked Immunosorbent Assay for the Organophorus Insecticide Bromophos

  • Park, Won-Cheol;Cho, Young-Ae;Kim, Yoo-Jung;Hammock, Bruce D.;Lee, Yong-Tae;Lee, Hye-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권10호
    • /
    • pp.1399-1426
    • /
    • 2002
  • A competitive enzyme-linked immunosorbent assay (ELISA) was developed for the quantitative detection of the organophosphorus insecticide bromophos. Three bromophos analogues (haptens) were synthesized and were coupled to carrier proteins to use as immunogens or coating antigens. Rabbits were immunized with either one of two haptens coupled to bovine serum albumin (BSA) for production of polyclonal antibodies, and the sera were screened against one of the haptens coupled to ovalbumin (OVA). Using the serum with highest specificity and an enzyme tracer, an antibody-coated ELISA was developed, which showed an $IC_{50}$ of 40 ng/mL with a detection limit of 7 ng/mL. The antibodies in this assay showed negligible cross-reactivity with other organophosphorus pesticides except with the insecticides chlorpyrifos and fenitrothion.

Development of an Enzyme-linked Immunosorbent Assay Using Vitellin for Vitellogenin Measurement in the Pale Chub, Zacco platypus

  • Lim, Eun-Suk;Lee, Eun Hee;Kim, Myung Hee;Han, Chang-Hee;Lee, Sung-Kyu;Kim, Jiwon
    • Environmental Analysis Health and Toxicology
    • /
    • 제28권
    • /
    • pp.16.1-16.8
    • /
    • 2013
  • Objectives Fish vitellogenin (VTG) is produced in the female liver during oogenesis through the estradiol cycle and produced in the male liver by endocrine disrupting chemicals (EDCs) such as alkylphenols. In this study, we propose that the VTG concentration in the pale chub could be detected using monoclonal antibodies and polyclonal antibodies against vitellin (Vn) in a VTG enzyme-linked immunosorbent assay (ELISA) system. Methods Monoclonal antibodies and polyclonal antibodies were produced using the Vn extracted from the matured ovum of the ovary. The VTG was extracted from the plasma of the male pale chub. The Vn and VTG were confirmed by measuring the molecular weight of their proteins using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and the specificity of the antibodies was checked through western blotting methods. The assay system was validated with respect to optimal assay concentrations, specificity, recovery, and intra- and inter-assay variations. Results The Vn consisted of two protein bands with apparent molecular weights of 64 and 37 kDa. The SDS-PAGE indicated protein weights of 146 and 77 kDa in the VTG. The assay range was 15.6 ng/mL to 2,000 ng/mL, and the value of the intra- and inter-assay variations were within 10.0% and 14.7%, respectively. The recovery rate was $99.5{\pm}5.5%$. Conclusions A sandwich ELISA was developed that could be used to qualify the VTG of pale chub in screening for EDCs. Pale chub is an ideal species for observing estrogen activity in the environment because of its extensive habitat and extensive food chain. The ELISA developed here would be more favorable than those for other species for determining the effect of long-term food chain accumulation of EDCs in aquatic environments.

Clq-coated ELISA법을 이용한 정맥용 면역글로불린제제의 항보체성 측정 (Clq-Coated Microtitre Enzyme-linked Immunosorbent Assay for Measuring the Anticomplementary Activity of Intravenous Immunoglobulin Preparations)

  • 강혜나;김순남;신광훈;허숙진
    • 약학회지
    • /
    • 제45권6호
    • /
    • pp.656-663
    • /
    • 2001
  • The quality of an intravenous immunoglobulin preparation (IVIG) is reflected by the degree of nonspecific activation of complements, the so-called anticomplementary activity (ACA). ACA of aggregates in IVIG was investigated using method by the European Pharmacopoeia and Clq-coated microtiter enzyme-linked immunosorbent assay (ELISA). Both the EP method and the ELISA method showed a dose response curve with the amount of complements bound increasing with the percentage content of aggregates in immunoglobulin standard. The correlation between the two tests was good (r=0.96, r=0.99). However, the correlation was not found when the ACA (EP method) of IVIG product was compared with its aggregate percentage. These results emphasize that the method of aggregate formation affects ACA and that estimation of the percentage distribution of aggregates by HPLC may not reflect ACA. In analysing WIG product for Clq binding activity test with the ELISA, the result by using Protein A-HRP correlated with aggregate percentage (r=0.84). But the correlation decreased (r=0.48) when the result used Protein A-AP(having poorer sensitivity than HRP) was compared with aggregate percentage. As a result, some variation between the two methods, due to differences in assay principles, is to be expected. However, ELISA technique has the advantage in that it is easier to perform, more precise and less subject to reagent variability, and is the more suitable screening method than HPLC analysis.

  • PDF

Quantitation of Plasma Apolipoprotein A-I with a Sandwich Type Enzyme-Linked Immunosorbent Assay Using Monoclonal Antibodies

  • Lee, Min-Gyu;Kang, Jae-Seon;Jeong, Jae-Yeon;Jue, Dae-Myung;Kim, Hack-Joo
    • BMB Reports
    • /
    • 제30권6호
    • /
    • pp.390-396
    • /
    • 1997
  • A sandwich-type enzyme-linked immunosorbent assay (ELISA) for the quantification of human apolipoprotein A-I (apoA-I) was developed using monoclonal antibodies. For this assay, we used three monoclonal antibodies to trap and detect apo A-I. HDAI16 and HDA15 monoclonal antibodies were used for trapping apoA-I and HDAI8 monoclonal antibody was for detecting apoA-I. These three monoclonal antibodies were produced by immunizing mice with high density lipoprotein (HDL) isolated from human plasma. By immunoblot analysis, these three monoclonal antibodies were specific to apoA-I and showed no cross-reactivities with other plasma proteins. The results of competition assays for epitope cross-reactivity test also verified that these monoclonal antibodies identified separate and distinct epitopes on HDL and apoA-I. Affinity constants of monoclonal antibodies were measured by ELISA. Their association constants ranged from $10^7$ to $10^8$ $M^{-1}$. For this assay, pure apoA-I was isolated by affinity chromatography using monoclonal antibodies. In this sandwich assay, the amount of HRP-labeled HDAI8 bound to apoA-I trapped by HDAI16 and HDAI5 was proportional to apoA-I concentration in the range of 0 to 500ng/ml. ApoA-I concentration in plasma was calculated from the linear regression equation of standard curve. The precision and reliability of the assays are reflected in the low intra-and interassay coefficients of variation that averaged 3.25% and 4.30%, respectively. This assay is sensitive, simple, reproducible, convenient in incubation interval, and does not use radioisotope: thus it can be widely applied in clinical laboratories.

  • PDF

하수처리장의 내분비계장애물질에 대한 Yeast Two-hybrid Assay와 Enzyme-linked Immunosorbent Assay에 의한 에스트로겐활성도 평가 (Evaluation of the Estrogenic Activity by Yeast Two-hybrid Assay and Enzyme-linked Immunosorbent Assay in Sewage Treatment Plant)

  • 이병천;나진성;김상돈;;이철희
    • 대한환경공학회지
    • /
    • 제29권7호
    • /
    • pp.771-777
    • /
    • 2007
  • 가정계열과 공단계열로 분리하여 처리되는 하수처리장에서 에스트로겐 활성을 평가하기 위하여 yeast two-hybrid assay와 enzyme-linked immunosorbent assay(ELISA)를 이용하여 내분비계장애물질의 농도와 활성도를 측정하였다. 그 결과 가정계열 유입수 중에서 estrone (E1), 17$\beta$-estradiol(E2), 17$\alpha$-ethinylestradiol(EE2) 그리고 APE의 농도는 각각 최대 167.1, 39.7, 7.3, 145.4 ng/L까지 검출되었다. 활성슬러지법에 의한 처리로, 17$\beta$-estradiol의 평균제거율은 77.5%, 고도처리 공정인 모래여과와 오존산화를 거친 후에는 80.8%까지 제거되는 것으로 나타났다. 동시에 Yeast two-hybrid assay로 각 내분비계장애물질의 농도-반응곡선으로부터 반응식을 구하여, 에스트로겐 활성에 미치는 각 물질의 기여도를 분석한 결과, 가정계의 활성슬러지법에 의한 처리수에서 estrone, 17$\beta$-estradiol 17$\alpha$-ethinylestradiol, APE 가 각각 70.7, 23.3, 3.7, 2.32%로 나타났다. 즉, 생물학적 처리공정을 통해 배출된 처리수의 에스트로겐 활성에 영향을 미치는 주된 기여물질은 estrone과 17$\beta$-estradiol인 것으로 나타났다.

Biotin의 분석을 위한 효소면역측정법(ELISA)의 개발 (Development of Enzyme-Linked Immunosorbent Assay for Rapid and Sensitive Analysis of Biotin)

  • 이경애;손동화;고영태
    • 한국식품영양과학회지
    • /
    • 제27권6호
    • /
    • pp.1152-1159
    • /
    • 1998
  • In order to develop more rapid and reproducible analysis of biotin known as vitamin H, attempts were made to establish the condition for enzyme linked immunosorbent assay(ELISA) compared with traditional microbiological assay(MBA). Antibiotin and antiserum were obtained from the immunized rabbits injected with emulsion of biotin KLH conjugate and Freund's adjuvant. The antiserum showed cross reactivity on biocytin, a derivative of biotin, which is converted to biotin in intestine, at the rate of 177%(median inhibitory concentration(IC50)=12.58ppb), but not on other derivatives such as desthiobiotin, diaminobiotin and 2 imino biotin. Specific antibody for biotin was purified from the antiserum through protein A column and desalting column. The conditions of competitive direct ELISA (cdELISA) were established. Detection range of biotin concentration by cdELISA was 0.01∼300ng/ ml(ppb). In the spike test with milk, fruit flake and pine carrot juice, the correlation coefficient between two methods of MBA and ELISA was reliably consistent at the value of r=0.992. But detection of biotin by microbiological assay(MBA) was rather restricted in range and nonspecific. Detection range of biotin by MBA was 0.1∼0.5ng/ml(ppb). It showed cross reactivities on biocytin and desthiobiotin at the rate of 80.1% and 66.7%, respectively. In conclusion, ELISA revealed a significant improvement compared with MBA for the biotin detection in terms of sensitivity, detection range and cross reactivity. In addition, a variety of samples could be analyzed rapidly and conveniently at one time by using ELISA. These results strongly suggest that the ELISA is very promising for the practical application to detect biotin contents in a wide range of food stuffs.

  • PDF