• Title/Summary/Keyword: Environmental smoke

Search Result 303, Processing Time 0.025 seconds

A Study on Environmental Pollution Issues in Fireworks Display (불꽃놀이의 환경오염 측면에 관한 연구)

  • Ahn, Myung-Seog;Lee, Jin-Ho;Shin, Chang-Young
    • Explosives and Blasting
    • /
    • v.26 no.2
    • /
    • pp.45-51
    • /
    • 2008
  • Fireworks display is called as younwha in korean, pokjuk in chinese, hanabi in japanese and fireworks display in English. Fireworks is a kind of art calling as engineering art program that presents its artistic sense by making up light, sound, heat, form, smoke, smoke screen, time delay and kinetic energy etc. which are made by combustion and deflagrations of explosives. Korea's fireworks skill is world class. In 1980s, we already developed the skills. After 2010 year, It would develop as Nano-biotechnology considering its environmental safety passing by 1990s' grow fully step. After pleasant fireworks, it requires a environmental pollution control measure, ability of emergency state control, management of storing place, a blind shell and waste disposal and citizenship elevation etc. This paper indicated around fireworks the present conditions, environmental pollution buzz, direction of development and plan.

Effect of Premixed Fuel on the Combustion Characteristics of Premixed Charge Compression Ignition Engine (예혼합 연료에 따른 균일 예혼합 압축 착화 엔진의 연소특성)

  • Hwang, Jin-Woo;Kim, Dae-Sik;Rhyu, Youl;Lee, Ki-Hyung;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.49-54
    • /
    • 2003
  • The purpose of this work is to investigate the effect of premixed fuel on the reduction of exhaust emissions in premixed charge compression ignition engine. The premixed fuel is injected into the intake manifold to form homogeneous pre-mixture in the combustion chamber. The pre-mixture is ignited by a small amount of diesel fuel directly injected into the cylinder. In the case of gasoline as a premixed fuel of the engine, $NO_x$ and smoke concentration of exhaust emissions were reduced compared with the conventional diesel engine. But in the event of diesel fuel for premixed fuel, the rate of smoke reduction was small compared with the case of gasoline as a premixed fuel. HC and CO emissions were increased at high premixed ratio in the case of two premixed fuels. The combustion characteristics of the engine such as the combustion pressure, the rate of heat release, and other characteristics are compared.

Scientific Data for an Assessment of the Potential Risk for Lung Cancer Associated with the Exposure to Environmental Tobacco Smoke in Korea (환경중 담배연기와 폐암유발 위험성의 관련 여부)

  • Walk, Roger;Zhang, Mingda
    • Proceedings of the Korean Society of Tobacco Science Conference
    • /
    • 1997.10a
    • /
    • pp.30-78
    • /
    • 1997
  • Exposure of nonsmokers to environmental tobacco smoke (ETS) has been claimed to be associated with an increased risk for lung cancer e. g., in the US, Europe, Japan and several Asian countries. The present paper reports on and discusses the scientific evidence available to date that can be used in order to assess this potential risk for Korea. Evidence related to three key steps in risk assessment, i.e., the characterization of a potential risk, data associating a response to a dose, and data characterizing actual exposures of people to ETS will be reviewed. The final assessment of the potential risk will be left to those qualified and commissioned with the task of risk assessment as a basis for public health policy in Korea.

  • PDF

Changes of CO, $CO_2$, TVOC and Aerosol of Tobacco Smoke in a Poorly-Ventilated Indoor (환기가 불량한 실내공간에서, 담배연기에 의한 CO, $CO_2$, TVOC 및 에어로졸의 변화)

  • Han Don-Hee;Park Soo-Jin;Ryu Ji-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.132-139
    • /
    • 2006
  • Number of aerosol, CO, $CO_2$ and TVOC after one-, two-, three-cigarettes smoking were monitored with time every 10 minute for 180 minutes in the seminar room (volume $51.1m^3$) when poorly-ventilated. IAQ monitor (IAQRAE, model PGM-5210) and PortCount (TSI, model 8020) were used for monitoring. Aerosol was decreased with exponential decay equation and it was estimated that number of aerosol would be long suspended (one cigarette 75/cc. two cigarettes 66/cc, three cigarettes 141/cc by 8hrs after smoking). While CO was also decreased with exponential or linear decay equation and correlated with number of aerosol strongly, TVOC and $CO_2$ were increased with linear equation in accordance with time lag. Most of TVOC and $CO_2$ were above standard levels of Korean Indoor Air Quality (Ministry of Environment) without regarding number of cigarettes. When naturally ventilated, all of CO, $CO_2$ and TVOC concentrations were dramatically decreased below standard levels of Korean Indoor Air Quality.

Urinary cotinine concentration by passive smoking in the PC game room (PC방에서의 간접흡연에 따른 요중 코티닌의 농도)

  • Park Yong Sun;Roh Youngman;Kim Chi Nyon
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.1
    • /
    • pp.11-20
    • /
    • 2002
  • Tobacco smoke was confirmed as a human carcinogen by many research results. Because many adolescents stay long time in the PC game room, they are exposed to much of tobacco smoke. To evaluate the effect of passive smoking in the PC game room, airborne nicotine concentrations in 2 PC game rooms in Sung-nam city and urinary cotinine concentrations were measured for 20 adolescents. And the subjects were interviewed for duration and time in PC game room and smoking pattern. Subjects are composed of each of 10 smokers(5 males and 5 females) and 10 nonsmokers(5 males and 5 females). They stayed for three hours in the PC game room without smoking. Concentrations of nicotine in smokers and nonsmokers were 129.72 $\mu$g/$^3$ and 99.99 $\mu$g/m$^3$, respectively. Urinary cotinine concentrations were increased as time goes on after exposure to nicotine and showed maximum value at 9.45 hours after nicotine exposure and were 32.21 and 110.66 $\mu$g/L for nonsmoker and smokers. The more using time and frequency in PC game room, the higher urinary cotinine maximum concentration and the longer using duration, also the more increase urinary cotinine concentration. Urinary cotinine has a tendency to increase by passive smoking. Therefore, it is recommended that the effective control for indoor air quality and extensive research be needed to reduce nicotine concentration by passive smoking in the PC game room.

A Study on the Smoking among Elementary School Students (군 지역 초등학생들의 흡연실태에 관한 연구)

  • Lee Inn Sook
    • Child Health Nursing Research
    • /
    • v.10 no.3
    • /
    • pp.272-281
    • /
    • 2004
  • Purpose: To investigate the prevalence of smoking behavior among elementary students which may serve as basic data for developing a smoking prevention program. Method: Questionnaires were given to 734 fourth, fifth, and sixth graders in five elementary schools in U county, North Chungcheong Province. Data were collected from 8 to 20 December, 2003; and analyzed using SPSS/PC for descriptive and chi-square statistics. Result: Of these students, 19.9% reported that they had smoked and 0.8% answered they are current smokers. They reported that the first smoking started during third grade (26.0%), at their homes (38.4%), and out of curiosity (74.0%). They reported severe coughing when they first smoked (56.2%). Smoking experiences were significantly related to grade, gender, and academic performance. Similarly, environmental characteristics such as residential area, parental status, father's job, parental attention, home atmosphere, and smoking siblings or friends were significantly related to smoking behavior. Among non-smokers, 86.4% intended not to smoke and 1.4% would like to smoke in the future. Conclusion: Certain school and environmental characteristics were associated with smoking experimentation. Therefore teachers and parents should use this information to develop and guide smoking prevention programs.

  • PDF

Effect of May 31, 2022 Miryang Forest Fire on Fine Particle Concentration in Nearby Urban Areas (2022년 5월 31일 발생한 밀양산불이 인근 도시 지역의 미세먼지 농도에 미치는 영향)

  • Byung-Il Jeon
    • Journal of Environmental Science International
    • /
    • v.32 no.1
    • /
    • pp.37-46
    • /
    • 2023
  • This study investigated the effect of May 31, 2022 Miryang wildfire on fine particle concentrations in Busan and Gimhae, which are neighboring urban areas. In addition, fine particle characteristics and air pollution concentrations were investigated in Miryang, where haze occurred. The Miryang city wildfire that occurred on May 31, 2022, at 0925 LST, was driven by strong north winds and increased fine particle concentrations in Dongsangdong and Jangyoodong, Gimhae City, which are approximately 35 km to the southeast and south, respectively, of the wildfire occurrence site. Furthermore, the fine particle concentration in Myeongjidong, which is approximately 50 km south-southeast of the wildfire site, exhibited a temporary increase at 1400 LST owing to the effects of wildfire smoke. On the morning of June 1, the day after the fire, the Miryang area had very bad visibility because of the smoke from the fire. Therefore the PM10 and PM2.5 concentrations in Naeildong, 3 km south of the wildfire site, were 276 ㎍/㎥ and 222 ㎍/㎥, respectively, at 1200 LST. In addition, the gases O3, CO, and SO2 showed high concentrations at the time of haze generation. This study provides insights into policy making in response to the rapid increase in fine dust when wildfire occurs near cities.

Deduction of Aerosol Composition and Absorption factors using AERONET sun/sky radiometer (AERONET 선포토미터 데이터를 이용한 에어로졸 조성 및 광흡수 특성 인자 도출)

  • Noh, Youngmin;Lee, Chulkyu;Choi, Sungchul
    • Korean Journal of Remote Sensing
    • /
    • v.29 no.4
    • /
    • pp.407-413
    • /
    • 2013
  • The Modified Aerosol Factor (MAF) derived from spectral Single-Scattering Albedo (SSA) values was created to express the light absorption properties according to aerosol types. As a factor of the MAF, slope of a linear regression line for SSA at four wavelengths shows positive value for dust aerosol, while negative values were found for mixing with other types of aerosol. The negative values were shown by anthropogenic and smoke aerosols. The modified SSA at 1020 nm was also calculated. MAF was calculated by summing the slope and modified SSA. MAF was -1.0 for the anthropogenic and smoke aerosol and 1.5 for the dust particles. Those values were decreased by increasing light absorption property.

Opportunistic Insights into Occupational Health Hazards Associated with Waterpipe Tobacco Smoking Premises in the United Kingdom

  • Al-Bakri, Ali;Jawad, Mohammed;Salameh, Pascale;al'Absi, Mustafa;Kassim, Saba
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.621-626
    • /
    • 2015
  • Background: Smokefree laws aim to protect employees and the public from the dangers of secondhand smoke. Waterpipe premises have significantly increased in number in the last decade, with anecdotal reports of poor compliance with the smokefree law. The literature is bereft of information pertaining to waterpipe premise employees. This study aimed to opportunistically gather knowledge about the occupational health hazards associated with working in waterpipe premises in London, England. Materials and Methods: Employees from seven convenience-sampled, smokefree-compliant waterpipe premises in London were observed for occupational activities. Opportunistic carbon monoxide (CO) measurements were made among those with whom a rapport had developed. Observations were thematically coded and analysed. Results: Occupational hazards mainly included environmental smoke exposure. Waterpipe-serving employees were required to draw several puffs soon after igniting the coals, thereby providing quality assurance of the product. Median CO levels were 27.5ppm (range 21-55ppm) among these employees. Self-reported employee health was poor, with some suggestion that working patterns and smoke exposure was a contributory factor. Conclusions: The smokefree law in England does not appear to protect waterpipe premise employees from high levels of CO. Continued concerns surrounding chronic smoke exposure may contribute to poor self-reported physical and mental wellbeing.