• Title/Summary/Keyword: Environmental parameters

Search Result 5,072, Processing Time 0.032 seconds

Flood Discharge to Decision of Parameters in Han Stream Watershed (한천유역의 홍수량 산정을 위한 HEC-HMS 모형의 민감도 분석)

  • Jung, Woo-Yul;Yang, Sung-Kee;Kim, Dong-Su
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.533-541
    • /
    • 2014
  • The streams in Jeju Island have very distinctive hydrological and geological properties and there are a lot of limits in applying the general flood estimation method. This study presented parameters dominant in the Hancheon stream of Jeju Island by analyzing the sensitivity of parameters of HEC-HMS model regarding rainfall events in the target basin, and extracted the optimal parameter(Time of Concentration of Clark Unit Hydrograph: Kraven II method, Storage Coefficient: Sabol method) by analyzing and comparing it with the flood runoff data observed in the site and Jeju Island's observation data.

A systematic approach to the calibration of micro-parameters for the flat-jointed bonded particle model

  • Zhou, Changtai;Xu, Chaoshui;Karakus, Murat;Shen, Jiayi
    • Geomechanics and Engineering
    • /
    • v.16 no.5
    • /
    • pp.471-482
    • /
    • 2018
  • A flat-jointed bonded-particle model (BPM) has been proved to be an effective tool for simulating mechanical behaviours of intact rocks. However, the tedious and time-consuming calibration procedure imposes restrictions on its widespread application. In this study, a systematic approach is proposed for simplifying the calibration procedure. The initial relationships between the microscopic, constitutive parameters and macro-mechanical rock properties are firstly determined through dimensionless analysis. Then, sensitivity analyses and regression analyses are conducted to quantify the relationships, using results from numerical simulations. Finally, four examples are used to demonstrate the effectiveness and robustness of the proposed systematic approach for the calibration procedure of BPMs.

Estimation of Parameters of the Linear, Discrete, Input-Output Model (선형 이산화 입력-출력 모형의 매개변수 결정에 관한 연구)

  • 강주복;강인식
    • Journal of Environmental Science International
    • /
    • v.2 no.3
    • /
    • pp.193-199
    • /
    • 1993
  • This study has two objectives. One is developing the runoff model for Hoe-Dong Reservoir basin located at the upstream of Su-Young River in Pusan. To develop the runoff model, basic hydrological parameters - curve number to find effective rainfall, and storage coefficient, etc. - should be estimated. In this study, the effective rainfall was calculated by the SCS method, and the storage coefficient used in the Clark watershed routing was cited from the report of P.E.B. The other is the derivation of transfer function for Hoe-Dong Reservoir basin. The linear, discrete, input-output model which contained six parameters was selected, and the parameters were estimated by the least square method and the correlation function method, respectively. Throughout this study, rainfall and flood discharge data were based on the field observation in 1981.8.22 - 8.23 (typhoon Gladys). It was observed that the Clark watershed routing regenerated the flood hydrograph of typhoon Gladys very well, and this fact showed that the estimated hydrological parameters were relatively correct. Also, the calculated hydrograph by the linear, discrete, input-output model showed good agreement with the regenerated hydrograph at Hoe-Dong Dam site, so this model can be applicable to other small urban areas. Key Words : runoff, effective rainfall, SCS method, clark watershed iou상ng, hydrological parameters, parameter estimation, least square method, correlation function method, input-output model, typhoon gladys.

  • PDF

The Potential of Sentinel-1 SAR Parameters in Monitoring Rice Paddy Phenological Stages in Gimhae, South Korea

  • Umutoniwase, Nawally;Lee, Seung-Kuk
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.4
    • /
    • pp.789-802
    • /
    • 2021
  • Synthetic Aperture Radar (SAR) at C-band is an ideal remote sensing system for crop monitoring owing to its short wavelength, which interacts with the upper parts of the crop canopy. This study evaluated the potential of dual polarimetric Sentinel-1 at C-band for monitoring rice phenology. Rice phenological variations occur in a short period. Hence, the short revisit time of Sentinel-1 SAR system can facilitate the tracking of short-term temporal morphological variations in rice crop growth. The sensitivity of SAR backscattering coefficients, backscattering ratio, and polarimetric decomposition parameters on rice phenological stages were investigated through a time-series analysis of 33 Sentinel-1 Single Look Complex images collected from 10th April to 25th October 2020 in Gimhae, South Korea. Based on the observed temporal variations in SAR parameters, we could identify and distinguish the phenological stages of the Gimhae rice growth cycle. The backscattering coefficient in VH polarisation and polarimetric decomposition parameters showed high sensitivity to rice growth. However, amongst SAR parameters estimated in this study, the VH backscattering coefficient realistically identifies all phenological stages, and its temporal variation patterns are preserved in both Sentinel-1A (S1A) and Sentinel-1B (S1B). Polarimetric decomposition parameters exhibited some offsets in successive acquisitions from S1A and S1B. Further studies with data collected from various incidence angles are crucial to determine the impact of different incidence angles on polarimetric decomposition parameters in rice paddy fields.

Determination of a Minimum Detectable Activity through a Measurement of Pu Isotopes in Environmental Samples

  • Lee, M. H.;Jung, E. C.;Song, K.S.
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.6
    • /
    • pp.1162-1166
    • /
    • 2008
  • In this paper, several parameters affecting the sensitivity and determining the minimum detectable activity (MDA) for the measurement of the Pu isotopes were investigated. Among the parameters affecting the determination of the MDA values for the Pu isotopes in the environmental samples, amounts of the samples appeared to be crucial factors in decreasing the MDA values. The MDA for the Pu isotopes in the environmental samples were calculated by varying the counting time of the samples and background. The results obtained in this study can be used for an environmental radiation monitoring program regarding the level of concern for a radionuclide beyond which some action may need to be taken.

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach (고도처리 효율 향상을 위한 통계적 접근)

  • Moon, Kyung-Sook;Min, Kyung-Sub;Kim, Seung-Min;Lee, Chan-Hyung
    • Journal of Environmental Science International
    • /
    • v.17 no.4
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

Particle size distributions and concentrations above radiators in indoor environments: Exploratory results from Xi'an, China

  • Chen, Xi;Li, Angui
    • Environmental Engineering Research
    • /
    • v.20 no.3
    • /
    • pp.237-245
    • /
    • 2015
  • Particulate matter in indoor environments has caused public concerns in recent years. The objective of this research is to explore the influence of radiators on particle size distributions and concentrations. The particle size distributions as well as concentrations above radiators and in the adjacent indoor air are monitored in forty-two indoor environments in Xi'an, China. The temperatures, relative humidity and air velocities are also measured. The particle size distributions above radiators at ten locations are analyzed. The results show that the functional difference of indoor environments has little impact on the particle size distributions above radiators. Then the effects of the environmental parameters (particle concentrations in the adjacent indoor air, temperatures, relative humidities and air velocities) on particle concentrations above radiators are assessed by applying multiple linear regression analysis. Three multiple linear regression models are established to predict the concentrations of $PM_{10}$, $PM_{2.5}$ and $PM_1$ above radiators.

Software approach towards understanding meteorological data for environmental monitoring and assessment of peninsular Malaysia

  • Quadri, Sayed Abulhasan;Sidek, Othman;Jafar, Hadi;binti Amran, Nur Amira;bt Zabah, Ummi Nurulhaiza;bin Abdullah, Azizul
    • Advances in environmental research
    • /
    • v.3 no.1
    • /
    • pp.87-106
    • /
    • 2014
  • The concern for the global environment ensues researchers from various disciplines to work in collaboration to tackle with the issues of sustainability and environmental conservation for well-being of the people. In this study, we have selected and focused on few basic environment-effecting factors such as temperature, humidity, carbon dioxide and oxygen concentration level and referred them as meteorological data. In this paper, we present the development of our own customized hardware setup, environmental monitoring device (EMD) to obtain the data. Utilizing the relationship among these basic parameters, represented in the form of formulas and equations, we tried to encode them using Matlab programming. Data visualization is achieved by plotting the graphs of basic parameters obtained from EMD as well for the derivatives using Matlab programs.

Risk assessment of Nitrogen Dioxide exposure on Welders

  • Jeong Seong-Wook;Song Seung-Hyg;Park Heung-Jai
    • Journal of Environmental Science International
    • /
    • v.14 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • This study evaluated the hazard caused by $NO_{2}$, an oxidant generated in the process of welding. We com­pared hematological and biochemical parameters in workers who chronically inhale $NO_{2}$ and office workers not exposed to $NO_{2}$. $NO_{2}$ exposure affected the hematological and biochemical parameters. Increasing $NO_{2}$ concen­trationincreased the number of leukocytes, while decreasing the number of erythrocytes. Blood urea nitrogen, cre­atinine, uric acid, and lactate dehydrogenase were increased, while total protein and triglycerides were decreased. The mean concentration of $NO_{x}(NO_{2}^{-}/NO_{3}^{-})$ in the serum of welders and the control group was $35.97{\pm}2.85\;and\;55.40{\pm}5.81\;{\mu}mol/L,$ respectively. The difference was significant (p < 0.05), although $NO_{2}^{-}$ was not detected in the serum.