• Title/Summary/Keyword: Environmental hazardous detection

Search Result 56, Processing Time 0.03 seconds

Recent Advanced Toxicological Methods for Environmental Hazardous Chemicals (환경 오염물질의 진보된 독성 평가 기법)

  • 류재천;최윤정;김연정;김형태;방형애;송윤선
    • Environmental Analysis Health and Toxicology
    • /
    • v.14 no.1_2
    • /
    • pp.1-12
    • /
    • 1999
  • Recently, several new methods for the detection of genetic damages in vitro and in vivo based on molecular biological techniques were introduced according to the rapid progress in toxicology combined with cellular and molecular biology. Among these methods, mouse lymphoma thymidine kanase (tk) gene forward mutation assay, single cell gel electrophoresis (comet assay) and transgenic animal and cell line model as a target gene of lac I (Big Blue) and lac Z (Muta Mouse) gene mutation are newly introduced based on molecular toxicological approaches. The mouse lymphoma tk$\^$+/-/ gene assay (MOLY) using L5178Y tk$\^$+/-/ mouse lymphoma cell line is one of the mammalian forward mutation assays, and has many advantages and more sensitive than hprt assay. The target gene of MOLY is a heterozygous tk$\^$+/-/ gene located in 11 chromosome, so it is able to detect the wide range of genetic changes like point mutation, deletion, rearrangement, and mitotic recombination within tk gene or deletion of entire chromosome 11. The comet assay is a rapid, simple, visual and sensitive technique for measuring and analysing DNA breakages in mammalian cells, Also, transgenic animal and cell line models, which have exogenous DNA incorporated into their genome, carry recoverable shuttle vector containing reporter genes to assess endogenous effects or alteration in specific genes related to disease process, are powerful tools to study the mechanism of mutation in vivo and in vitro, respectively. Also in vivo acridine orange supravital staining micronucleus assay by using mouse peripheral reticulocytes was introduced as an alternative of bone marrow micronucleus assay. In this respect, there was an International workshop on genotoxicity procedure (IWGTP) supported by OECD and EMS (Environmental Mutagen Society) at Washington D. C. in March 25-26, 1999. The objective of IWGTP is to harmonize the testing procedures internationally, and to extend to finalization of OECD guideline, and to the agreement of new guidelines under the International Conference of Harmonization (ICH) for these methods mentioned above. Therefore, we introduce and review the principle, detailed procedure, and application of MOLY, comet assay, transgenic mutagenesis assay and supravital staining micronucleus assay.

  • PDF

A Study on the Application of Smart Safety Helmets and Environmental Sensors in Ships (선박 내 스마트 안전모 및 환경 센서 적용에 관한 연구)

  • Do-Hyeong Kim;Yeon-Chul Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.2
    • /
    • pp.82-89
    • /
    • 2023
  • Due to the characteristics of ship structure, the compartment structure is complicated and narrow, so safety accidents frequently occur during the work process. The main causes of accidents include structural collisions, falling objects, toxic substance leaks, fires, explosions, asphyxiation, and more. Understanding the on-site conditions of workers during accidents is crucial for mitigating damages. In order to ensure safety, the on-site situation is monitored using CCTV in the ship, but it is difficult to prevent accidents with the existing method. To address this issue, a smart safety helmet equipped with location identification and voice/video communication capabilities is being developed as a safety technology. Additionally, the smart safety helmet incorporates environmental sensors for temperature, humidity, vibration, noise, tilt (gyro sensor), and gas detection within the work area. These sensors can notify workers wearing the smart safety helmet of hazardous situations. By utilizing the smart safety helmet and environmental sensors, the safety of workers aboard ships can be enhanced.

Prototype Fabrication and Performance Evaluation of Metal-oxide Nanoparticle Sensor for Detecting of Hazardous and Noxious Substances Diluted in Sea Water (해수 중 유해위험물질 검출을 위한 금속산화물 나노 입자 센서의 시작품 제작 및 성능 평가)

  • Sangsu An;Changhan Lee;Jaeha Noh;Youngji Cho;Jiho Chang;Sangtae Lee;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.23-29
    • /
    • 2022
  • To detect harmful chemical substances in seawater, we fabricated a prototype sensor and evaluated its performance. The prototype sensor consisted of a detector, housing, and driving circuit. We built the detector by printing an Indium-Tin-Oxide (ITO) nanoparticle film on a flexible substrate, and it had two detection parts for simultaneous detection of temperature and HNS concentration. The housing connected the detector and the driving circuit and was made of Teflon material to prevent chemical reactions that may affect sensor performance. The driving circuit supplied electric power, and display measured data using a bridge circuit and an Arduino board. We evaluated the sensor performances such as response (ΔR), the limit of detection (LOD), response time, and errors to confirm the specification.

A Study on the Concentration of Aflatoxin B1 in Granule and Globular Types of Herbal Medicines (엑스과립과 환으로 만들어진 한방생약제제의 aflatoxin B1 연구)

  • Bae, Jong-Sup;Kim, Yong-Ung;Park, Moon-Ki
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.209-215
    • /
    • 2010
  • This study is an endeavor to evaluate the risk assessment of hazardous(aflatoxin $B_1$) in medicines from oriental medical prescription which are circulated much recently. For that, twelve globular and granule types, seven liquid types of herbal medicine were bought to compare and analyze the content of aflatoxin aflatoxin B_1), which are harmful to human body. Woo Hwang Cheong Sim Hwan of Aflatoxin $B_1$ concentration lower than the standard accepted by all the products have been detected, B company(tradition) is the concentration of $1.24\;{\mu}g/kg$, C company $1.04\;{\mu}g/kg$, A company(tradition) and B company did not detect. And the general pill of aflatoxin B1 concentration lower than the standard accepted by all the products have been detected, S-1 is the concentration of $1.8\;{\mu}g/kg$, S-2 of $1.04\;{\mu}g/kg$, S-3 of $0.88\;{\mu}g/kg$, S-4 of $9.32\l\;{\mu}g/kg$, S-6 of $7.8\;{\mu}g/kg$, S-5 did not detect. All the products eundan allowed in the concentration of aflatoxin $B_1$ levels were lower than detection, D company of $0.96\;{\mu}g/kg$, E company concentration was not detected. The liquid product of aflatoxin $B_1$ concentration was found liwer than the standard accepted by all the product, L-3 concentration of $0.8\;{\mu}g/kg$, K-4 was detected in the $1.16\;{\mu}g/kg$, L-1 and L-2 is not detected, L-5 concentration of $15\;{\mu}g/kg$, L-7 is detected as $1.08\;{\mu}g/kg$ and, L-6 was not detected.

Study on the Effect of the Electrode Structure of an ITO Nanoparticle Film Sensor On Operating Performance (ITO Nanoparticle Film을 이용한 센서의 전극 구조가 동작 성능에 미치는 영향에 대한 연구)

  • An, Sangsu;Noh, Jaeha;Lee, Changhan;Lee, Sangtae;Seo, Dongmin;Lee, Moonjin;Chang, Jiho
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.90-95
    • /
    • 2022
  • The effect of the structure of an ITO nanoparticle film sensor on its performance was studied. A printed ITO film (P-ITO film) was fabricated on a flexible polyethylene terephthalate (PET) substrate, and the contact resistance of the electrode and sensor response change were clarified according to the detection position. The contact resistance between Ag and P-ITO was observed to be -204.4 Ω using the transmission line method (TLM), confirming that a very good ohmic contact is possible. In addition, we confirmed that the contact position of the analyte had a significant influence on the response of the sensor. Based on these results, the performance of the four types of sensors was compared. Consequently, we observed that 1) optimizing the resistance of the printed film, 2) optimizing the electrode structure and analyte input position, and 3) optimizing the electrode area are very important for fabricating a metal oxide nanoparticle (MONP) sensor with optimal performance.

Characterization of Leaching Behaviour of Recycled Concrete for Environmental Assessment (용출특성규명을 통한 재생골재 환경성 평가)

  • Kang, S.H.;Lee, S.H.;Kwak, K.S.;Lee, J.Y.;Chung, M.K.
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.3
    • /
    • pp.293-301
    • /
    • 2005
  • We conducted several different leaching experiments for assessing the potential environmental risk when utilizing recycled concrete for stabilizing bridge pier. The methods include continuous batch leaching test (DIN 38414-S4), availability test (NEN 7341), pH-stat test (CEN/TC 292/WG6) and tank diffusion test (NEN 7345). The concentration ranges vary depending on the testing method. Nearly all the trace elements were low, some elements recording under detection limit. The maximum concentrations for trace elements leached throughout the whole tests are (as mg/L); Cd (0.029), Cu (0.437), Pb (0.14), Ni, Zn (0.95), Hg (0.005). Although the testing methods we used in this study are much more rigorous than other commonly adapted method including TCLP and domestic testing method for solid waste, the trace elemental concentrations are under the criteria for hazardous material set by the TCLP and domestic method. The result seems to suggest that applying the recycled concrete on stream water will be accepatable practice as for as trace elements are concerned. However, the influence of inorganics such as Ca, Mg, Ni and $SO_4^{2-}$ on aquatic ecology should be further examined.

Determination of Heterocyclic Amines and Acrylamide in Agricultural Products with Liquid Chromatography-Tandem Mass Spectrometry

  • Lee, Kyung-Jun;Lee, Gae-Ho;Kim, HaeSol;Oh, Min-Seok;Chu, Seok;Hwang, In Ju;Lee, Jee-yeon;Choi, Ari;Kim, Cho-il;Park, Hyun-Mee
    • Toxicological Research
    • /
    • v.31 no.3
    • /
    • pp.255-264
    • /
    • 2015
  • Heterocyclic amines (HCAs) and acrylamide are unintended hazardous substances generated by heating or processing of foods and are known as carcinogenic and mutagenic agents by the animal experiments. A simple method was established for a rapid and accurate determination of 12 types of HCAs (IQ, MeIQ, Glu-P-1, Glu-P-2, MeIQx, Trp-P-1, Trp-P-2, PhIP, $A{\alpha}C$, $MeA{\alpha}C$, Harman and Norharman) and acrylamide in three food matrices (non-fat liquid, non-fat solid and fat solid) by isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS). In every sample, a mixture of internal standards including $IQ-d_3$, $MeIQx-d_3$, $PhIP-d_3$, $Trp-P-2-^{13}C_2-^{15}N$ and $MeA{\alpha}C-d_3$ was spiked for quantification of HCAs and $^{13}C_3$-acrylamide was also spiked for the analysis of acrylamide. HCAs and acrylamide in sample were extracted with acetonitrile and water, respectively, and then two solid-phase extraction cartridges, ChemElut: HLB for HCAs and Accucat: HLB for acrylamide, were used for efficiently removing interferences such as pigment, lipid, polar, nonpolar and ionic compounds. Established method was validated in terms of recovery, accuracy, precision, limit of detection, limit of quantitation, and linearity. This method showed good precision (RSD < 20%), accuracy (71.8~119.1%) and recovery (66.0~118.9%). The detection limits were < 3.1 ng/g for all analytes. The correlation coefficients for all the HCAs and acrylamide were > 0.995, showing excellent linearity. These methods for the detection of HCAs and acrylamide by LC-MS/MS were applied to real samples and were successfully used for quantitative monitoring in the total diet study and this can be applied to risk assessment in various food matrices.

Ttrosine Hydroxylase in Japanese Medaka (Oryzias latipes): cDNA Cloning and Molecular Monitoring of TH Gene Expression As a Biomarker (송사리 Tyrosine Hydroxylase: cDNA 클로닝 및 생물지표로서의 TH 유전자 발현의 분자생물학적 추적)

  • Shin, Sung-Woo;Kim, Jung-Sang;Chon, Tae-Soo;Lee, Sung-Kyu;Koh, Sung-Cheol
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.4
    • /
    • pp.131-137
    • /
    • 2000
  • The release of hazardous waste materials into the environment poses serious risks in humans and ecosystems. The risk assessment of environmental pollutants including hazardous chemicals requires a comprehensive measurement of hazard and exposure of the chemicals that can be achieved by toxicity evaluation using a biological system such as biomarkers. In this report we have tried to develop a biomarker used to elucidate a molecular basis of, and to monitor abnormal behaviors caused by diazinon in Japanese medaka (Oryzias latipes) as a model organism. First, an attempt was made to clone tyrosine hydroxylase gene from Japanese medaka that would be a candidate for a biomarker for neuronal modulations and behaviors. For monitoring experiments at behavioral and molecular biological levels, the fish were treated under different sublethal conditions of diazinon and their behavioral responses were observed . In this study we have successfully cloned a partial TH gene from the medaka fish through PCR screening of an ovary cDNA library. DNA sequencing analysis revealed that the amplified fragment was 327 bp encoding 109 amino acids. Comparing the DNA sequence of medaka TH with other species, TH gene revealed the DNA sequence was completely identical to that of rat TH. In the RT-PCR, 330 Up of mRNA was consistently amplified in all the treated samples including control There were no significant differences in the TH expression level regardless of treating concentrations (1∼5,000 ppb) and time (0∼48 hr) The reason appeared to be that RT-PCR was not performed using through a quantitative analysis normalized against an actin gene expression. Organ or tissue - specific detection of TH activity and mRNA as biomarkers will be a useful monitoring tool for neurobehavioral changes in fish influenced by toxic chemicals. Furthermore, quantitative analysis of locomotive patterns and its correlation with the neurochemical and molecular data would be highly useful in measuring toxicity and hazard ofvarious environmental pollutants.

  • PDF

Distribution of Seven N-Nitrosamines in Food

  • Park, Jong-eun;Seo, Jung-eun;Lee, Jee-yeon;Kwon, Hoonjeong
    • Toxicological Research
    • /
    • v.31 no.3
    • /
    • pp.279-288
    • /
    • 2015
  • N-nitrosamines, which are classified as carcinogens by IARC and US EPA, can be easily found in various foods. They are reaction products between nitrogen oxide and secondary amines, but can also be generated during fermentation. Ever since the 1960s, when nitrite, used as a preservative in processed meats, was suspected to generate N-nitrosamines, the usage of the food additive has been debated. However, the benefit of nitrite in food supply could not be ignored and the risk-benefit analysis has become a key issue in the use of the additive. For a risk analysis, an accurate estimation of the hazardous material is necessary; therefore, analytical methods for nitrosamines have continuously evolved from the 1950s. Solid supported liquid-liquid extraction and solid phase extractions have replaced the distillation for the clean-up steps, and tandem mass spectrometry is employed for higher selectivity and sensitivity. In the present study, for a better estimation of N-nitrosamine intake, the total diet study samples were prepared for the N-nitrosamines analysis. In order to obtain the most sensitive results, a partial preparation procedure was developed and modified for different food matrices. Among seven N-nitrosamines (N-nitrosodimethylamine, N-nitrosomethylethylamine, N-nitrosodiethylamine, N-nitrosodibutylamine, N-nitrosopiperidine, N-nitrosopyrrolidine, and N-nitrosomorpholine) analyzed in the present study, N-nitrosodiethylamine has shown the highest detection rate in agricultural foods, while N-nitrosodimethylamine has appeared most frequently in livestock and fishery food products. The concentration of N-nitrosodimethylamine was the highest in seasoning.

Benzene Contents and Reliability of Material Safety Data Sheets for Paint Thinners sold in Busan, Ulsan, and Gyeongnam (부·울·경에서 판매되는 도료 희석제의 구성성분 함량과 물질안전보건자료의 신뢰성에 관한 연구)

  • Sungjun, Woo;Kwonchul, Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.340-349
    • /
    • 2022
  • Objectives: The importance of MSDS is emphasized for communicating hazardous information due to the increase in the types and usage of chemical substances. The purpose of this study is to assess the reliability of MSDS by collecting and examining paint thinners commercially available in South Korea. Methods: Twenty-five paint thinners were purchased at paint stores and the provision of MSDS was checked. Quantitative and qualitative analysis was performed on the chemical constituents of the thinners using GC-MSD and GC-FID. Reliability was evaluated by the MSDS collection rate for the paint thinners and calculating the rate of matching between laboratory analysis results and the contents and composition of chemical constituents given in the MSDS. Results: Unlike a study conducted in 2006, MSDS were provided for all 25 thinners. As a result of qualitative analysis using GC-MSD, 104 chemical substances were detected. The substances with the highest detection rate were identified in the order of toluene, butyl acetate, acetone, xylene, and ethyl benzene. A component matching rate of 41% was found by comparing the differences between the number of substances detected in laboratory testing and the number of substances listed in the MSDS. Benzene, a carcinogen not listed in the MSDS, was detected in two thinners produced by a small company. The detected benzene contents were 0.039 and 0.040%. When benzene is used, it should be strictly handled according to the Industrial Safety and Health Act. However, since it is not listed on the MSDS, it is judged that benzene was not being managed as a carcinogen in the workplaces where it is used. Conclusions: Since the reliability of MSDS, which play an important role in hazard communication, was evaluated to be low, it is necessary to systematically and continuously secure this reliability. In particular, carcinogens should be managed more strictly.