• Title/Summary/Keyword: Environmental Values

Search Result 6,473, Processing Time 0.034 seconds

Children's View of Environmental Value and Attitudes : On the basis of Age and Gender (유치원생과 초등 학생이 가지는 자연 환경에 대한 가치관 및 태도 -연령별, 성별 차이를 중심으로-)

  • 신동희;이동엽
    • Hwankyungkyoyuk
    • /
    • v.13 no.2
    • /
    • pp.63-73
    • /
    • 2000
  • The purpose of this study are two-fold; 1) to identify the differences in the view of environmental value between 6-years-olds and 12-years-old, 2) to identify the differences in the attitude towards animals and plants between male-and female students. To accomplish the purposes of this study, two researchers deeply interviewed ten 6-years-old and 12-years-old boys and girls, respectively. First, the interviewees are asked to rank six constituents in nature, human-being, tiger, ant, gingko tree, weed, and stone, from their views of environmental value. Then, the interviewees were asked to talk about their various interaction with animals and plants. The results of this study are as follows; 1) In evaluating the value of nature constituents, 12-years-olds tended to be affected by scientific knowledge. On the other hand, 6-years-olds tended to evaluate the value of nature constituents by their emotional feeling; 2) From the perspectives of environmental ethics, 12-years-olds showed attitudes in anthropocentric or holistic ethics. On the other hand, 6-years-olds showed attitudes in nonanthropocentric ethics; 3) In evaluating the value of nature constituents, 12-year-olds tended to consider the constituent′s instrumental values and 6-years-olds tended to consider their intrinsic values; 4) From the perspectives of "ethics of care", females, especially 12-years females tended to take care of plants. The results propose more emphasis of environmental "sensuous" in school environmental education. And male- and female students should be expected fairly in their environmental attitudes, especially in taking care of natural creatures.

  • PDF

Validation and Calibration of TUNVEN Model (TUNVEN 모형의 검증 및 보정)

  • Cheong, Jang-Pyo;Yoon, Sam-Seok;Yi, Seung-Muk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.785-796
    • /
    • 2000
  • In this study, the possibility of application of TUNVEN model was investigated through the validation and calibration processes. In order to validate and calibrate the TUNVEN model developed in USA to obtain prediction of the quasi-steady state longitudinal air velocities and the pollutants concentrations by solving the coupled one-dimensional steady state tunnel aerodynamic and advection equations. The major input parameters such as the concentration data for CO and $NO_x$, meteorological data and traffic volume in Hawngryung tunnel were measured. Prior to preparing the input parameters, the sensitivity analysis was conducted to identify the input parameters which need to be most accurately estimated in TUNVEN program. In order to establish the relationships between the model values and the measured values, the linear regression analysis was applied. In linear regression analysis, the model values were taken as independent parameter(X) and the measured values were taken as dependent parameter(Y) for four cases of data sef. From the results of linear regression analysis, the correlation coefficient(r) for four cases were calculated more than 0.91 and the values of slope and interception were analyzed as 0.5~2.2 and 0.01~2.3 respectively. From the above results, we concluded that the suitability of TUNVEN model was identified in prediction the longitudinal pollutant concentrations in tunnel.

  • PDF

Adsorption Characteristics of Cd(II) and Cu(II) by Zeolites Synthesized from Hwangto (황토로부터 합성한 제올라이트에 의한 Cd(II) 및 Cu(II) 흡착특성)

  • 감상규;홍정연;허철구;이민규
    • Journal of Environmental Science International
    • /
    • v.12 no.7
    • /
    • pp.817-824
    • /
    • 2003
  • Various kinds of zeolites, such as analcime (ANA), cancrinite (CAN), Na-Pl and sodalite octahydrate (SOD) could be synthesized from Hwangto by hydrothermal reaction in a high-pressure vessel. The adsorption characteristics of Cu(II) and Cd(II) by Hwangto and its synthetic zeolites were investigated using the chemical and electrochemical surface parameters of these adsorbents. The heavy metal adsorptivity among the adsorbents decreased in the following sequences: Na-Pl > SOD > ANA > CAN > Hwangto. This sequence was the same with the values of surface site density (Ns) of these adsorbents and was correlated inversely with the values of pHpzc (pH of the point of zero charge) and the va]ues of K$\_$a2/(int) (intrinsic surface deprotonation constant) of the adsorbents for synthetic zeolites, i.e., the adsorbents with higher values of Ns and with lower values of pHpzc and K$\_$a2/(int) for synthetic zeolites showed higher heavy metal adsorptivity. With increasing pH, the heavy metal adsorptivity increased greatly between pHpzc and pH 6 or 7 because of the steep increase of negatively charged sites for synthetic zeolites, but for Hwangto, it increased broadly because of slow increase of negatively charged sites based on its lower surface sites.

A Sanitary Survey on the Clean Water by Domestic Purifier (가정용 정수기의 수질에 대한 위생학적 조사 소견)

  • 채용곤
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 1990
  • To study on the water quality of domestic purifier, twenty four samples of clean water by purifier and the raw water(tap water) were tested for biological and physico-chemical examination and were checked for style of purification and the period elapsed after changing of purification medium. The results were as follows; Biological and physico-chemical findings of raw water were not exceeded standard values. Average number of general bacteria,2.coli and pH in clean water were significantly higher than that of raw water(respectively, p<0.01), but mean contents of turbidity, chloride, nitrate and iron in clean water were significantly lower than that of raw water(respectively, p<0.01). In general count of bacteria and E.coli, a half of the clean water of ceramic filter and roverse osmosis style were exceeded standard values for drinking water. All of the pH of the ion exchange style clean water were exceeded standard values. But other findings were within standard values. In average bacterial counts and physico-chemical findings of clean water by purification style of purifier, clean water of ion exchange style purifier were lowest number of general bacteria and not detected in 2. coli. But other items were highest. The longer period elapsed after changing of purification medium were the higher contents of biological and physico-chemical findings of clean water.

  • PDF

Development of PSCF Model and Determination of Proper Values of Control Parameters (PSCF 모형의 개발과 제어변수의 결정)

  • Cheong, Jang-Pyo;Lee, Seung-Hoon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.1
    • /
    • pp.135-143
    • /
    • 2006
  • The objective of this study is to develop PSCF (potential source contribution function) program and determine the optimal values of control parameters to enhance the prediction of PSCF modeling. This study provides an important information and methodologies that can be used to get better results of locating influencing sources, especially unknown and fugitive sources. To determine proper values of control parameters in PSCF model, the diagnostic assessment on the results obtained by the various input conditions was carried out. PSCF model has created and improved from version 1.0 to version 7.0 since 200 I and the measured data (at least > 100) of receptor, and the values of control input parameters should be arranged and determined to obtain reliable results in PSCF modeling. The size of modeling domain must be determined to include enough trajectories to get reliable results. And the size of grid is recommended to be 2.5 $\sim$ 5 degrees for global scale, 0.2 $\sim$ 1 degrees for regional scale and 0.05 degree for local scale.

Assessment and Analysis of Noise Pollution in Cheongju Area (청주지역 환경소음도 조사 및 분석)

  • 연익준;주소영;김광렬
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2001
  • The increase of economic growth has brought out the noise pollutions in city regions. To evaluate these problems, this study was investigated to assessment and analysis of noise pollutions at Cheongju area in winter and summer seasons. The noise levels were measured and analyzed at the general areas the 4 roadside areas (park, residential, commercial, and industrial area). As a result, following facts have been found. The equivalent sound levels(Leq) at general are in winter were 51.3∼78.2 dB(A) at the daytime and 41.1∼63.1 dB(A) at the nighttime And in summer there were 53.5∼77.3 dB(A) at the daytime and 41.9∼64.0 dB(A) at the nighttime, respectively. These values were higher than average value of Korea. At the roadside area, the values of Leq were 51.9∼72.8 dB(A) at the daytime, 44.3∼68.2 dB(a) at the nighttime in winter, and in summer there were 62.5∼73.1 dB(A) at the daytime and 50.4∼68.3 dB(A) at the nighttime, respectively. These values were lower than average value of Korea. The calculated traffic noise index(TNI) were 64.6∼93.6 at the daytime and 26.5∼106.6 at the nighttime in winter, In summer, there were 65.0∼90.7 at the daytime, and 32.3∼91.8 at the nighttime. The TNI values varied wide ranges at the nighttime according to traffic volumes.

  • PDF

Longitudinal Variation of Fish Communities in the Geum River, Korea: Application of the Concept of Beta Diversity and Local Uniqueness

  • Kim, Jeong-Hui;Park, Sang-Hyeon;Baek, Seung-Ho;Hong, Donghyun;Jo, Hyunbin
    • Proceedings of the National Institute of Ecology of the Republic of Korea
    • /
    • v.3 no.2
    • /
    • pp.122-128
    • /
    • 2022
  • To present the spatial variation of fish assemblages in the Geum River in Korea, the concept of beta diversity (β-diversity) estimates based on the variance of the community data table was applied. Fish communities and environmental variables were collected from 13 sampling sites along the in mid-low reaches of the River. We calculated the β-diversity and local contribution to beta diversity (LCBD) values at each site depending on the two types of data, 'occurrence' with Jaccard and Sørensen dissimilarity coefficients, and 'abundance' with Hellinger distance. Multivariate and correlation analyses were also performed to determine the relationships between LCBD and other variables, such as community indices and physicochemical and hydrological factors. The β-diversity values of fish communities in the River were estimated as 0.218 and 0.145 for occurrence data table with Jaccard and Sørensen respectively, and 0.268 for abundance data. Similar patterns of LCBD along the sampling sites were detected in two dissimilarity measurements of occurrence table, and LCBD values with abundance data were slightly different. The LCBD values are strongly correlated with community indices, and also suitable for indicating the uniqueness of fish assemblages. However, further research is needed to determine the LCBD value as an indicator of environmental variability.

실험동물 마우스의 혈액세포 분포에 관한 연구

  • Ian C. Guest
    • Toxicological Research
    • /
    • v.7 no.1
    • /
    • pp.47-50
    • /
    • 1991
  • Hematological studies in two strains of normal laboratory mice, namely ICR and ddY which were produced in Koren were carried out. Blood analysis was performed by using different methods, a fully automated analyzer (ELT 1, 500), Coulter counter (model S plus IV) and manual technique to examine possible differences resulting from methodolgies'slight differences among the values of blood parameters were obtained. There was a slight difference noted between sexes, however, similar values were obtained from both strains.

  • PDF

Heating Values of Agricultural Wastes for Substitute Energy Development (농업부산물의 발열량 조사(지역환경 \circled2))

  • 홍성구
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.563-568
    • /
    • 2000
  • Animal waste is a major agricultural waste or wastewater that requires appropriate treatment to prevent environmental pollution. In this presentation, it is examined if incineration of manure compost is an alternative to treatment of animal waste. Heating values of selected biomass including manure compost were obtained using a bomb calorimeter. Based on heating values of manure and manure compost, ranging from 1200 - 1500 kcal/kg on wet base, incineration could be an alternative for animal waste treatment if available land is limited for land application and sufficient reduction of water content in manure compost.

  • PDF

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.