• Title/Summary/Keyword: Environmental Standard

Search Result 4,689, Processing Time 0.038 seconds

Sewage Treatment Using a Double Media Reed Constructed Wetland (복층여재 갈대 인공습지에 의한 생활하수 처리)

  • Seo, Jeoung-Yoon
    • Journal of Wetlands Research
    • /
    • v.16 no.4
    • /
    • pp.379-388
    • /
    • 2014
  • A sewage was treated using a serially combined vertical(VFCW) and horizontal flow double media (sand and zeolite for VFCW and sand and waste oyster-shell for HFCW) reed constructed wetland(HFCW) with intermittent feeding (see Fig. 1). The sewage was fed into the reed constructed wetland for 10 minutes every 6 hours at the hydraulic load of $314L/m^2{\cdot}day$. The summarized results were as follows: pH values in the effluent depended very heavily on oyster-shell height filled in the HFCW. They were maintained at less than pH 6.24 when the height of the oyster-shell layer was 200 mm. Influent DO(oxygen demand) values(average 0.19 mg/L) were increased in the VFCW(average 7.65 mg/L) and decreased again in the HFCW(average 6.49 mg/L). They were higher in the winter than in the summer. The OTR(oxygen transfer rate) was $57.15g\;O_2/m^2{\cdot}day$ in the VFCW and $5.65g\;O_2/m^2{\cdot}day$ in the HFCW. The removal efficiency of $NH_4{^+}$-N was 80.17%(6.01 $NH_4{^+}$-N mg/L in the effluent). It was lower than that in the case where only zeolite was filled in the reed constructed wetland. But it was expected that treated sewage effluent using a double media reed constructed wetland with 300 mm zeolite layer could stably meet the Korean treated sewage effluent standard(20 mg T-N/L). Average removal efficiencies were SS 88.09%, BOD 88.12%, $COD_{Cr}$ 83.11%, $COD_{Mn}$ 85.58%, T-N 57.21%, $NH_4{^+}$-N 80.17%, T-P 86.73%. Nearly, The concentration of $NO_3{^-}$-N in the effluent of the VFCW was decreased in that of the HFCW. More than half of T-N in the effluent was $NO_3{^-}$-N(7.92 mg/L) but the concentration of $NO_2{^-}$-N in the effluent was average 0.90 mg/L. The removal efficiencies of T-P were 93.24%, 86.30% and 55.44% at the height of the oyster-shell-filled constructed wetland of 800 mm, 500 mm and 200 mm, respectively and therefore, they were proportional to oyster-shell height filled in the HFCW.

Research of Statistical Model for Genetic Evaluation of Hanwoo Carcass Traits (한우 도체형질의 유전능력평가를 위한 통계모형 탐색)

  • Koo, Yang-Mo;Kim, Si-Dong;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Jeoung, Yeoung-Ho;Lee, Jae-Youn;Jang, Hyun-Gi;Park, Byoung-Ho;Choi, Te-Jong;Cho, Kwang-Hyun;Lee, Seung-Soo;Lee, Jung-Gyu;Kim, Hyo-Sun
    • Journal of Animal Science and Technology
    • /
    • v.53 no.4
    • /
    • pp.283-288
    • /
    • 2011
  • This study was conducted to study the environment effects on live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score, which are the carcass traits of Hanwoo, based on the estimates and all the possible regression for the selection of variable and significance test for 231,382 heads that underwent the carcass measurements. The average and standard deviation for the live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score were 654.79${\pm}$91.61 kg, 362.30${\pm}$67.15 kg, 59.52${\pm}$0.03%, 81.79${\pm}$12.21 $cm^2$, 11.39${\pm}$5.40 mm, 4.38${\pm}$2.29, respectively. The live weight, carcass weight, dressing percentage, eye muscle area, backfat thickness, and marbling score for cow were 532.79${\pm}$78.38 kg, 313.40${\pm}$44.90 kg, 56.50${\pm}$0.03%, 75.24${\pm}$10.69 $cm^2$, 11.82${\pm}$5.10 mm, 4.30${\pm}$2.06, respectively, while for bull were 619.74${\pm}$93.27 kg, 376.89${\pm}$48.62 kg, 58.61${\pm}$0.02%, 85.61${\pm}$10.46 $cm^2$, 5.64${\pm}$2.71 mm, 1.41${\pm}$0.83, respectively, and for steer were 681.78${\pm}$70.72 kg, 415.23${\pm}$49.43 kg, 60.19${\pm}$0.02%, 88.29${\pm}$10.27 $cm^2$, 12.71${\pm}$5.23 mm, 5.42${\pm}$1.99, respectively. In the environmental variables selection based on the variables selection method, the examination by carcass traits suggested that the most appropriate model could be determined when five variables were selected for the live weight, carcass weight, dressing percentage, eye muscle area, and four variables for backfat thickness, and marbling score. When they were considered at a time altogether based on multiple traits, it was deemed to be desirable to insert all five variables into the variables for analysis. In addition, high significance was found by carcass traits.

Evaluating the Removal Efficiency of Organic Compounds and Nitrogen Depending on Loading Rate in Wastewater Treatment from Fisheries Processing Plant Using an Entrapped Mixed Microbial Cell Technique (미생물 강제포획기술을 이용한 수산물 가공공장 폐수처리에서 부하율에 따른 유기물 및 질소의 제거 효율성 평가)

  • Jeong Byung-Cheol;Chang Soo-Hyun;Jeong Byung-Gon
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.1
    • /
    • pp.14-20
    • /
    • 2006
  • In this study, the feasibility of simultaneous removal of organic materials and nitrogen in the waste-water from fisheries processing plant was evaluated using entrapped mixed microbial cell technique(EMMC) process. The experiment was performed using activated sludge from municipal sewage treatment plant which was immobilized with gel matrix by cellulose triacetate. It was found that the stable operation at the treatment system which is composed of anoxic and oxic tank, was possible when the organic and nitrogen loading rates were increased stepwise. The organic and nitrogen loading rates were applied from 0.65 to $1.72kgCOD/m^3/d$ and from 0.119 to $0.317kgT-N/m^3$ with four steps, respectively. The maximum nitrogen loading rate which could satisfy the regulated effluent standard of nitrogen concentration, was $0.3kgT-N/m^3/d$. The removal efficiency of total nitrogen was decreased apparently as increasing nitrogen loading rates, whereas the removal efficiency of ammonium nitrogen was effective at the all tested nitrogen loading rates. Therefore, it was concluded that nitrification was efficient at the system. Nitrate removal efficiency ranged from 98.62% to 99.51%, whereas the nitrification efficiency at the oxic tank ranged 94.0% to 96.9% at the tested loading rates. The removal efficiencies of chemical oxygen demand(COD) and those of total nitrogen at the entire system ranged from 94.2% to 96.6% and 73.4% to 83.4%, respectively.

  • PDF

Effects of Local Climatic Conditions on the Early Growth in Korean White Pine (Pinus koraiensis Sieb. et Zucc.) Stands -Relation between Annual Increment and Local Climatic Conditions- (지역별 잣나무 초기생장에 미치는 미기후의 영향 - 연년생장과 미기후와의 관계-)

  • Chon Sang- Keun;Shin Man Yong
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 1999
  • This study was conducted to investigate the effects of local climatic conditions on the annual increment of Korean white pine planted in Gapyung and Yaungdong. For this, stand variables such as mean DBH, mean height, basal area per hectare, and volume per hectare by stand age were measured and summarized for each locality. Based on these statistics, annual increments for 8 years from stand age 10 to 18 were calculated for each of stand variables. A topoclimatological technique which makes use of empirical relationships between the topography and the weather in study sites was applied to produce normal estimates of monthly mean, maximum, minimum temperatures, relative humidity, precipitation, and hours of sunshine. Then, the yearly climatic variables from 1990 to 1997 for each study site were derived from the spatial interpolation procedures based on inverse- distance weighting of the observed deviation from the climatic normals at the nearest 11 standard weather stations. From these estimates, 17 weather variables such as warmth index, coldness index, index of aridity etc., which affect the tree growth, were computed on yearly base for each locality. The deviations of measured annual increments from the expected annual increments for 8 years based on yield table of Korean white pine were then correlated with and regressed on the yearly weather variables to examine effects of local climatic conditions on the growth. Gapyung area provides better conditions for the growth of Korean white pine in the early stage than Youngdong area. This indicates that the conditions such as low temperature, high relative humidity, and large amount of precipitation provide favor environment for the early growth of Korean white pine. A ccording to the correlation and regression an analysis using local climatic conditions and annual increments, the growth pattern of Gapyung area corresponds to this tendency. However, it was found that the relationship between annual increments and local climatic conditions in Youngdong area shows different tendency from Gapyung. These results mean that the yearly growth pattern could not sufficiently be explained by climatic conditions with high variance in yearly weather variables. In addition, the poor growth in Youngdong area might not only be affected by climatic conditions, but also by other environmental factors such as site quality.

  • PDF

Studies on the Environmental Characteristics of the Breeding Ground in the Kogum-sudo, Southern Part of Korean Peninsula I. Seasonal Succession of Phytoplankton Population (거금수도내 양식어장의 해양환경특성 I. 식물플랑크톤 군집의 계절변동)

  • Yoon Yang Ho;Koh Nam Pyo
    • Journal of Aquaculture
    • /
    • v.8 no.1
    • /
    • pp.47-58
    • /
    • 1995
  • Field studies on the seasonal succesion of phytoplankton population were carried out at the 25 stations of the breeding ground in Kogum-sudo, Southern coast of Korean peninsula in Feburuary, April, August and October, 1993. Sixty four species belonging to 40 genera were identified. Predominant species were mainly centric diatoms throughout the four seasons, two centric diatoms, Skeletonema costatum and Thalassiosira sp. and a pennate diatom, Thaiassionema nitzschioides in the winter; two pennate diatoms, Thaiassionema nitzschioides and Asterionella kariana, and especially a dinoflagellate, Heterocapsa triquetra (station 10) in the spring, two centric diatoms, S. costatum and Chaetoceros diadema in the summer; and a centric diatom, Rhizosolenia alata and a pennate diatom, Bacillaria paxillifer in the fall. The main red tide organisms in the breeding ground were dinoflagellates, Prorocentrum dentatum, P. minimum, P. triestinum, Ceratium furro, Gymnodinium sanguineum, Noctiluca scintillans, H. triquetra, Scrippsiella trichoidea and a diatom S. costatum in the Kogum Sudo. Seasonal phytoplankton cell numbers were in a wide range between $8.8\times10^3$ cells/l and 1.4\times10^6$ cells/l; The seasonal average cell numbers were $12.2\times10^4\pm5.9\times10^4$ cells/l $(mean\;\pm\;standard\; diviation)$ in the winter, $3.3\times10^4\pm1.4\times10^4$ cells/l in the spring, $48.4X10^4\pm40.0\pm10^4$ cells/l in the summer, and $3.6\times10^4\pm1.9\times10^4$ cells/l in the fall, respectively.

  • PDF

Improved Preservation Methods for Big and Old Tress in South Korea (우리 나라의 노거수자원(老巨樹資源) 보호관리실태(保護管理室態) 및 개선방안(改善方案))

  • Park, Chong-Min;Seo, Byun-Soo;Lee, Cheong-Taek
    • Journal of Korean Society of Forest Science
    • /
    • v.89 no.3
    • /
    • pp.440-451
    • /
    • 2000
  • This study was conducted in order to provide essential data and relevant management proposal to conserve and maintain big and old trees in a rational way. For the field survey, 77 big and old trees preserved by the laws in Chollabuk-do, Korea were investigated. The study results are summarized as follows : 1. To conserve and manage big and old trees, the valuable trees have been designated as natural monument trees and protection-needed trees. There are 141 individuals of 37 species designated as natural monuments and 10,049 individuals of 102 species designated as protection-needed trees. 2. Management budget for natural monument trees was devoted at 70% from the national expenditure, but that for protection-needed trees was devoted at 98% from the local expenditure. 3. Standardized sign boards and sign stones for natural monument trees were well placed and other protection facilities such as fences, branch supports and branch holdings were established. On the other hand, management of protection-needed trees was deficient overall. 4. Problems for designation process and management of protection-needed trees could include items such as insufficient management budget, various development activities, land ownership, misjudgement of tree age and species identification, unsatisfaction of sign board placement, insufficient surgery for damaged trees, pavement around tree root system and environmental pollution around the trees. 5. In order to improve the existing management methods of big and old trees, the following schemes were suggested : the development of practical criteria for natural monument and protection-needed trees, nationwide surveys of big and old tree resources, the security of national budget, securing sufficient spaces for the tree growth, specialization of management systems, extended practices of tree form management, establishment of permanent standard signs and consideration of opinions of village residents.

  • PDF

The Flora of Vasular Plants and the Vegetation on the Tidal Flat in Jebudo(Island) (제부도 갯벌식생과 소산 식물상에 관한 연구)

  • Shin, Kyung-Mi;Ahn, Young-Hee
    • Korean Journal of Environment and Ecology
    • /
    • v.20 no.1
    • /
    • pp.52-69
    • /
    • 2006
  • The flora of vascular plants and the vegetation on the tidal flat was investigated in Jebudo located at Hwaseong city of Gyeonggi-do province from 2004 to 2005. Jebudo has been considered to show difference from the flora which is peculiar to island as it became semi-land by free traffic to mainland with the installation of a road which had enabled entry into the Jebudo in 1991 due to sea-splitting phenomenon. The result of the vascular plants in Jebudo were consissted of 305 taxa; 264 species, 38 varieties and 3 forms of 202 genera of 74 families. As a result of examination by distinctive survey areas within Jebudo, a tidal flat(I) region where the halophyte was being spread has been researched as 7 taxa; 7 species of 6 genera of 5 families. The taxa in Godo-Island(II) was reseached as 50 taxa; 39 species, 11 varieties and 42 genera of 24 families. The taxa in Sand dune area(III) was reseached as 61 taxa; 52 species and 9 varieties of 53 genera of 25 families. The most plant species was reseached in Mt. Tapjae (IV) reaseach area among the reseach areaes 136 taxa; 118 species, 17 varieties and 1 form of 108 genera of 55 families. The taxa in Dangje Mt.(V) was reseached as 119 taxa; 105 species, 13 varieties and 1 form of 95 genera of 45 familes. The taxa in Dongmi Mt. (VI) was reseached as 100 taxa; 85 species and 15 varieties of 83 enera of 43 families. The taxa in Paddy field(VII) was reseached as 120 taxa; 106 species, 13 varieties and 1 form of 86 genera 31 families. Especially, a Crypsinus hastatus community which is a rare plant designated by Korea forest service and a preservation plant designated by the natural environment preservation law (1998) has been discovered at a cliff of Topjae mountain near the ferry located at the northeast side. According to the result of researching halophyte communities which make up the zonation according to the environmental gradient, the communities were being formed in the order of Limonium tetragonum community, Phragmites communis community, Carex scabrifolia community, Triglochin maritimum community and Carex scabrifolia community in accordance with the order of soil particle size with breakwater as their standard.

Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains (보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.100-105
    • /
    • 2015
  • The calculation method of infiltration loss in greenhouse has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the infiltration rates using the tracer gas method in plastic greenhouses equipped with various thermal curtains. And then the calculation methods of infiltration loss in greenhouses were reviewed. Infiltration rates of the multi-span and single-span greenhouses were measured in the range of $0.042{\sim}0.245h^{-1}$ and $0.056{\sim}0.336h^{-1}$ respectively, single-span greenhouses appeared to be slightly larger. Infiltration rate of the greenhouse has been shown to significantly decrease depending on the number of thermal curtain layers without separation of single-span and multi-span. As the temperature differences between indoor and outdoor increase, the infiltration rates tended to increase. In the range of low wind speed during the experiments, changes of infiltration rate according to the outdoor wind speed could not find a consistent trend. Infiltration rates for the greenhouse heating design need to present the values at the appropriate temperature difference between indoor and outdoor. The change in the infiltration rate according to the wind speed does not need to be considered because the maximum heating load is calculated at a low wind speed range. However the correction factors to increase slightly the maximum heating load including the overall heat transfer coefficient should be applied at the strong wind regions. After reviewing the calculation method of infiltration loss, a method of using the infiltration heat transfer coefficient and the greenhouse covering area was found to have a problem, a method of using the infiltration rate and the greenhouse volume was determined to be reasonable.

Evaluation of confidence for measurement of VOCs in indoor air (실내공기질 VOCs 측정의 신뢰도 평가를 위한 연구)

  • Kim, Myoung Ock;Kim, Young Lan;Hong, Suk Young;Heo, Gwi Suk;Lim, Hyun Woo;Choe, Seoung Hun;Lee, Won Suk;Han, Jin Seok;Kim, Kum Hee
    • Analytical Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.165-173
    • /
    • 2013
  • To establishment of PT Program for Indoor air quality field that manufacture of confidential development PTMs (proficiency testing materials) and examined of proficiency testing evaluation included sampling process whether or not that is valid. Confirmation of homogeneity and stability of PTMs prepared. PTMs were confirmed to be homogeneous enough to be used as proficiency testing materials since withinbottle homogeneities of the RMs were lower than 0.3 times of targeted standard deviation of proficiency testing. The result of this study showed that the Robust RSD of proficiency testing for VOCs (volatile organic compounds) appeared 23~43% in concentration of 50~320 ${\mu}g/m^3$ for Method A(Distribution by adsorption in Tenax-tube of VOCs), but less 13~42% in concentration of 200~1200 ${\mu}g/m^3$, 16~31% in concentration of 100~450 ${\mu}g/m^3$ for Method B (distribution by VOCs of gas phase in 10L Tedalr bag), C (directly sampling of cylinder with high pressure) respectively. The result of this study showed that method C with sampling is most adequate to the proficiency testing for VOCs in indoor air.

Measurement of Specific Radioactivity for Clearance of Waste Contaminated with Re-186 for Medical Application (의료용 Re-186 오염폐기물의 규제해제를 위한 방사능측정)

  • Kim, Chang-Bum;Lee, Sang-Kyung;Jang, Seong-Joo;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.633-638
    • /
    • 2017
  • The amount of radioactive waste has been rapidly increased with development of radiation treatment in medical field. Recently, it has been a common practice to use I-131 for thyroid cancer, F-18 for PET/CT and Tc-99m for diagnosis of nuclear medicine. All the wastes concerned have been disposed of by means of the self-disposal method, for example incineration, after storage enough to decay less than clearance level. IAEA proposed criteria for clearance level of waste which depends on the individual ($10{\mu}Sv/y$) and collective dose (1 man-Sv/y), and concentration of each nuclide (IAEA Safety Series No 111-P-1.1, 1992 and IAEA RS-G-1.7, 2004). In this study, specific radioactivity of radioactive waste contaminated with Re-186 was measured to confirm whether it meets the clearance level. Re-186 has long half life of 3.8 days relatively and emits beta and gamma radiation, therefore it can be applied in treatment and imaging purposes. The specific radioactivity of contaminated gloves weared by radiation workers was measured by MCA(Multi-channel Analyzer) which was calibrated by reference materials in accordance with the measuring procedure. As a result, comparison evaluation of decay storage period between the half-life which was calculated by attenuation curve based on real measurement and physical half-life was considered, and it is showed that the physical half-life is longer than induced half-life. Therefore, the storage period of radioactive waste for self-disposal may be curtailed in case of application of induced half-life. The result of this study will be proposed as ISO standard.