• Title/Summary/Keyword: Environmental Fundamental Facilities

Search Result 71, Processing Time 0.02 seconds

Analysis of the Phosphorus Contribution Rate by the Environment Fundamental Facilities Located in Upstream Basin of Paldang Lake (팔당호 상류수계에 위치한 환경기초시설의 인 기여도 분석)

  • Woo, Younggug;Park, Eunyoung;Jeon, Yangkun;Yang, Heejeong;Rim, Jaymyung
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.6
    • /
    • pp.1016-1027
    • /
    • 2010
  • The phosphorus contribution rate on water quality of North and South-Han River, and Gyungan-cheon by effluents from environmental fundamental facilities located in upstream basin of Paldang Lake were analyzed. QUALKO2 model was selected for the analysis of contrubution rate, and was constructed considering the location of the main point sources and all facilities in study area. The pollutant loading rates and arrival rates for each unit-watershed in study area were calculated for model operation. For the calibration and verification of model, 2006 water quality dataset from Ministry of Environment and the effluent loadings of the environmental fundamental facilities were used. Reliability Index (RI) method was used to estimate the validity of the results of calibration and verification. The phosphorous contribution rate(%) for each environmental fundamental facility were analyzed by excepting the effluent loading of the facility. The contribution rate was analyzed for each facility, facility groups separated by each main river and each unit-watershed. The main results of analysis for each facility are as follows; (i) the phosphorous contribution of B1 facility is 50%, which is the highest phosphorous contribution rate among those of nine facilities in the North-Han River Basin; (ii) the highest phosphorous contribution is 55.6% from J facility among eight facilities in the Gyungan Stream Basin; (iii) 40% from E treatment facility is the highest among those of twenty eight facilities in the South-Han River Basin.

Fundamental Research of Preservation & Utility Facilities in Wetland Protected Area - 5 Wetland Protected Areas were Used as Main Subjects - (습지보호지역의 습지보전·이용시설 현황에 관한 기초 연구 - 5개 습지보호지역을 대상으로 -)

  • Cho, Dong-Gil;Park, Yong-Su;Shim, Yun-Jin;Lee, Ji-Hyun;Lee, Dong-Jin;Kim, Sang-Hyuk;Cha, Jin-Yeol;Park, Mi-Young;Song, Yu-jin;Nam, Chun-hee;Kim, Jong-cheol;Moon, Sang-kyun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.19 no.1
    • /
    • pp.25-43
    • /
    • 2016
  • This research was completed to provide fundamental data regarding the guidelines to installing and managing utility facilities & structures in wetland protected area to advance the functions and sustainable use of ecology services by preserving the ecology within wetland protected area. There were 5 on-site researching areas that were used as the main subject with these areas chosen and considered from 21 inland wetlands that have been designated and are being managed from the Ministry of Environment and by their designated dates as a wetland protected area. The utility facilities in these wetland areas were categorized by their types and a detailed on-site investigation was proceeded with investigation items chosen whereas these facilities are working by their roles from their location, size, used materials, types, information contents and etc., The results showed that regarding informational structures, several locations of information boards were distanced from the main exploring routes which did not consider the visitor's eye level which had their readability dropped and by sunlight, time lapse and water penetration, many information boards were damaged or corrupted so that it was hard to confirm the information noticed or understanding an image. Insufficient observation and educational structures were installed that considered the ecological characteristics of wild animals and their living conditions. Regarding convenience facilities, there were parking lots that were installed on the fore-land and to decrease non-point solution sources, some parking lots needed to be located in protected lowlands while some facilities' shape and colors did not harmonize with their natural surroundings, creating a sense of awareness, which will need some more consideration. As for safety facilities, they were very insufficient compared to other facilities. This means that additional safety structures are needed so that related personnel can be aware of where a visitor is located when an accident occurs. Protectional facilities strongly needed new structures and a management system to cut off entrances and do surveillance so that visitors do not go into areas outside of the managed areas and bring damages to restricted locations. Research labs needed to expand the use of automatic weather systems and water gauge equipments to build fundamental data regarding floodgates that are intimated to the forming of wetlands. Sensor cameras and other types of monitoring systems are needed to monitor the majority types of animals living in the wetlands as well.

Emission Characteristics of Odor Compounds from Fundamental Environmental Facilities in an Industrial Complex Area in Daegu City (대구시 산업단지 환경기초시설의 악취발생 특성)

  • Lee, Chan-Hyung;Jeon, Hyun-Sook;Shin, Myung-Cheol;Kim, Eun-Deok;Jang, Yun-Jae;Kwon, Byoung-Youne;Song, Hee-Bong
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.4
    • /
    • pp.246-254
    • /
    • 2016
  • Objectives: This study evaluated the odor emission characteristics from fundamental environmental facilities at an industrial complex area in Daegu City. Methods: The odor samples were collected from May 2015 to January 2016 and were analyzed for specified offensive odor substances. The odor quotient and the odor contribution was calculated. Results: Ammonia was detected in all samples monitoring specified odor compounds, followed by hydrogen sulfide and acetaldehyde. According to contribution analysis, hydrogen sulfide shows the highest contribution in all facilities. At wastewater treatment plants A and B and sewage treatment plant F, it was followed by acetaldehyde. At wastewater treatment plant C, it was followed by imethyl sulfide. Conclusion: The major component of odor can be determined by evaluating the degree of contribution to the odor intensity rather than the concentration of the individual odor components. To increase the effectiveness of odor reduction, policies focused on materials with a high odor contribution are needed rather than focusing on high-concentration odor compounds.

Analysis on the Actual Environmental Conditions of Domestic and Oversea Police Detention Facilities (국내외 경찰서 유치시설의 환경 실태 분석)

  • Cho, Hyeonmi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.339-349
    • /
    • 2013
  • The primary purpose of this research was to set up the standard guidelines for the planning of interior architectural environments of the detention facilities at the Korean Police Stations. By visit-studying the actual interior environmental conditions of 5 different kinds' domestic Correcting Facilities and 5 domestic police detention facilities and 2 foreign police detention facilities, comparing them to the existing Korean correctional institutions' cell facilities, that the strengths and weaknesses had been analyzed to extract the main concepts and the planning scheme for the Standard Korean Police Detention Facilities. By reserching the National human Right Commitee's Anual Reports, three different indexes were picked out for those analysis : the Environmental control index, the Detention Service support index, the Environmental support index. These three indexes will be used as Key factors for the planning of interior architectural environments of the detention facilities at the Korean Police Stations.: (1)the Environmental control index to establish the Space Program, the Spatial Hierarchy and the horizontal & vertical Security Blocks, (2)the Detention Service support index for the central Environmental Control & Security System, the Secured Privacy for both detainees & police offices, (3)the Environmental support index for the gender-respected segregation of cell zones, the psychological & physical safety design factors, the construction standards of all rooms in a detention facility. The result of this study should be used as the guidelines for "The Standard Plans and Regulations for the Korean Police Detention Facilities" to respect fundamental human rights.

A Study on the Medical Environmental Factor and Distinction of Medical Facilities for the Elderly in Berlin (베를린 노인의료 환경요인과 시설특성에 관한 연구)

  • Chai, Choul-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • Nowadays, a proportion of healthcare service for the elderly has been improved due to the factors, such as a prolonged life expectancy, a growth of aging population and a change of member of family. For these factors, it is necessary for the elderly to receive treatment for multidisciplinary diseases, associated with psychological care of sociological concept. It is quite difficult in an acute-care hospital to accommodate the elderly patient because of the fact that an acute-care hospital is required to maintain a high level of medical care and technical standard. That is why specialized medical service is needed for the elderly. In the case of Germany, they are at the stage of the change from large scale facilities to specialized facilities applying the integrated concept. This paper addresses the medical environmental factor and distinction of medical facilities for the elderly through survey and analysis relating to all change in Germany. Therefore, it aims to suggest a fundamental resource for architectural planning and network of medical facilities for the elderly.

Potential Application Topics of KOMPSAT-3 Image in the Field of Precision Agriculture

  • Kim, Seong-Joon;Lee, Mi-Seon;Kim, Sang-Ho;Park, Genn-Ae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.7
    • /
    • pp.17-22
    • /
    • 2006
  • Potential application topics of KOMPSAT-3 image in the field of precision agriculture are suggested. The topics can be categorized as fundamental and applied ones that have contents of static and dynamic characteristics respectively. As fundamental topics, precision information of agriculture that is related to farmland and its crop attributes, precision information of rural infrastructure that is related to rural village and its facilities, precision information of stream environment that is related to rural water resources and its facilities, and precision information of eco-environment that is especially related to riparian ecology and environmental status are included. As applied topics, precision rural water resources that has thematic contents of continuous and event-based runoff, spatial and temporal soil moisture and evapotranspiration, precision agricultural watershed environment that has the contents of spatial and temporal soil loss, sediment and pollutants transport, and precision temporal and spatial crop growth that has the contents of temporal crop texture, spectral reflectance, leaf area index, spatial crop protein information.

POTENTIAL APPLICATION TOPICS OF KOMPSAT-3 IMAGE IN THE FIELD OF PRECISION AGRICULTURE MODEL

  • Kim, Seong-Joon;Lee, Mi-Seon;Kim, Sang-Ho;Park, Geun-Ae
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.432-435
    • /
    • 2006
  • Potential application topics of KOMPSAT-3 image in the field of precision agriculture are suggested. The topics can be categorized as fundamental and applied ones that have contents of static and dynamic characteristics respectively. As fundamental topics, precision information of agriculture that is related to farmland and its crop attributes, precision information of rural infrastructure that is related to rural village and its facilities, precision information of stream environment that is related to rural water resources and its facilities, and precision information of eco-environment that is especially related to riparian ecology and environmental status are included. As applied topics, precision rural water resources that has thematic contents of continuous and event-based runoff, spatial and temporal soil moisture and evapotranspiration, precision agricultural watershed environment that has the contents of spatial and temporal soil loss, sediment and pollutants transport, and precision temporal and spatial crop growth that has the contents of temporal crop texture, spectral reflectance, leaf area index, spatial crop protein information.

  • PDF

A Study on the Evaluation and Improving Measures of Environmental Education Function of City Park - Concentrated on City Park in Seoul - (도시공원의 환경교육 기능 평가 및 개선방안에 관한 연구 - 서울시 도시공원을 중심으로 -)

  • 송영은;양병이
    • Hwankyungkyoyuk
    • /
    • v.11 no.2
    • /
    • pp.238-251
    • /
    • 1998
  • Environmental education, which has been thought as the most fundamental solution to environmental problems, should be performed not only in school but also in home and society with a long-term plan. In line with this, environmental-friendly attitude in daily life should be achieved by the perception of the vital environmental principle-new understanding of relation between nature and human being. It is in the city park that children in urban area, who has little opportunity to contact nature, have rather easier access to nature and realize the principle. Despite such great potential, the city park in Korea has not played its pivotal role because of lack of both facilities and activities. In addition, existing studies on this issue are not satisfactory. Therefore, this study is aimed at analyzing and evaluating city parks' environmental education function, potential and problems according to their types, then offering practical reform measures and programs in order to make students better understand the parks as an everyday natural experience spot. These plans are not based on full-scale revision, instead focuses on optimizing potential of existing natural environment and parks. Additionally, activities to experience various nature are included in the study. The value of city park is not decided by the park itself, but by its relationship with visitors. Environmental education function of city park is not confined to building up facilities and providing programs. It also should be complemented and improved, reflecting visitors' opinions and evaluation of environmental education.

  • PDF

Field Survey on the Shading Structure and Environmental Management for Ginseng Cultivation (인삼재배시설의 구조 및 환경관리 실태조사)

  • Nam, Sang-Woon
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.65-68
    • /
    • 2002
  • This study was conducted to secure the structural safety and to build fundamental data for development of controlled environment facilities in ginseng cultivation. Shading structures of ginseng cultivation were classified with materials, structural forms, and detailed setups. They are wood or steel pipe, single or multi span, and frame or cable type. For structures having representative forms and dimensions, modeling for structural analysis was builded by SAP2000. And there was almost no farm carrying out the environmental management specially.

  • PDF