• Title/Summary/Keyword: Environment Standard

Search Result 5,368, Processing Time 0.035 seconds

The Application of Surfactants to the Suppression of Fugitive Dust Generated from the Scrap Metal Loading Field in Inchon Port and Preliminary Evaluation on Their Wetting Capability (인천항 고철 하역 작업시 발생하는 비산분진 억제를 위한 계면활성제의 적용 및 기초 성능 평가)

  • Lee, Bo-Young;Yoo, Yong-Ho;Jung, Yong-Won;Kim, Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.1
    • /
    • pp.85-96
    • /
    • 2001
  • The objective of this study is to develop the water spraying which can effectively by applied to the control or suppression of the fugitive dust generated from the scrap metal handling area at the Port of Inchon. As a first step toward this goal, we carried out some preliminary analyses on the chemical composition, physical shape, and particle size distribution of the sample dust. Next, to quantitatively investigate the effect of adding surfactants to the spraying water on the wettability of the sample dust, the Standard Sink Test was carried out for four different surfactants and at six different concentrations using the surfactants considered in this study. Results of from the preliminary analysis indicated that the main chemical component consisting of the sample dust is Goethite(FeO(OH)) and that the particles smaller than 10 ${\mu}{\textrm}{m}$ in geometric diameter occupy about 36% of the sample dust in mass. This result implies that the fugitive dust generated from the scrap metal handling area at the Port of Inchon should affect the environment nearby more than we have expected. This is because of relatively large mass percentage of the small metal particles less than 10${\mu}{\textrm}{m}$ in geometric diameter, what we may call respirable particles. As for the results of the Standard Sink Test, higher surfactant concentration tends to result in the higher wettability of the sample dust for the surfactants considered in this study, which in turn ensures the high particle collection efficiency of the droplets generated from the water spraying system. Based upon this preliminary results, studies to develop more sophisticated scaled model for dynamic test in underway and the effort to find the best surfactants as well as the optimum operating conditions are being made at the same time.

  • PDF

Research on composting of sewage sludge using dryer facility with indirect heating system (간접가온 건조방식의 건조시설을 이용한 하수슬러지 퇴비화에 관한 연구)

  • Baik, Seon-Jai;Han, In-Sup;Choi, Ick-Hoon;Kang, Sung-Hyo;Hong, Seong-Min
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.299-304
    • /
    • 2014
  • The need of reusing sewage sludge is highly increasing as the amount of domestic sewage sludge is growing and sewage management strategies were reinforced. Accordingly, in this research, we studied the composting possibility of sludge in sewage treatment plant J, using dryer facility with indirect system by conducting component analysis of dried sludge and experiment on cultivating crops. It was observed from the component analysis, that the dried sludge is appropriate for both decomposed manure standard of Ministry of Environment and fertilizer standard of Rural Development Administration. Besides, in the experiment on cultivating lettuce, the experimental group(soil + dried sludge) was superior to the control group(soil + bed soil) in apparent condition of leaves tensity and damage by disease and pest. In case of cultivating tomato, the experimental group showed stronger durability of fruits dangling on stems compared to the control group after 9 weeks. Consequently, the excess sludge dried by indirect heating system in the sewage treatment plant J is appropriate for the standard of both Ministry of Environment and Rural Development Administration and show good result in experiment on cultivating crops therefore it can be reused for composting.

Development of Awning System using Light Shelf - Focusing on the light environment and lighting energy reduction performance improvement -

  • Jeong, Jinsoo;Lee, Heangwoo;Seo, Janghoo;Kim, Yongseong
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.5-13
    • /
    • 2017
  • Purpose: Various studies have been performed to address the issue of increased energy use by buildings. In particular, research on complex envelopes that combines diverse envelope element techniques is currently in progress in the building sector. The present study aimed to develop an awning system using a light shelf, and to verify its validity through performance evaluation. Method: In the present study, a testbed was established for the performance evaluation of the awning system using a light shelf, and the uniformity ratio and lighting energy consumption were compared and analyzed relative to those with no awning and light shelf installation (Case 1), awning installation (Case 2), and light shelf installation (Case 3). Result: 1) In the present study, an awning system using a light shelf (Case 4) where an opening is made on the awning screen and natural light can be introduced through the light shelf located at the bottom was developed. 2) The optimum standard for Case 4 obtained through the performance evaluation was a 0.6m lighting length and a 2m extension length at a light shelf angle of $30^{\circ}$. 3) Case 4 with the optimum standard had a 5.5% lower uniformity ratio than Case 2, but had a higher uniformity ratio than Case 1 and Case 3. 4) Case 4 with the optimum standard showed 13.3%, 44.6%, and 0%~8.7% lighting energy reductions compared to Case 1, Case 2, and Case 3, respectively. 5) Based on the above results, Case 4 suggested in the present study was found to be effective for indoor light environment improvement and lighting energy reduction.

Air Pollution History, Regulatory Changes, and Remedial Measures of the Current Regulatory Regimes in Korea (우리나라 대기오염 역사, 규제의 변천, 현행 규제제도의 개선방안)

  • Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.4
    • /
    • pp.353-368
    • /
    • 2013
  • All Koreans had suffered heavily from municipal and industrial air pollution problems since 1960's to 1980's. However the levels of $SO_2$, CO, and Pb have been dramatically decreased since 1990's due to various air pollutants' reduction policies under the provisions of the 1978 Environmental Preservation Act and the 1990 Air Quality Preservation Act such as increasing the supply of low-sulfur fuel, the use of cleaner fuel, no use of solid fuel, and so on. Even though the national ambient air quality standard has been strengthened to protect public health and welfare, the levels of $NO_2$, $O_3$, and $PM_{10}$ frequently exceed the corresponding standards; for example, only 4 stations (1.7%) out of 239 nationwide monitoring stations satisfied the 24-hr based PM10 standard in 2011. Moreover, upto the present time, since there are serious underlying policies of economism and growth-first which can not be solely solved by the environmental laws, it is difficult to root out undesirable social evils such as public indifference, passive academic activities, complacent government bureaucracy, insufficient social responsibility of enterprise, and radical activities of environmental groups. The paper initially reviewed air pollution history of Korea with surveying various environmental factors affecting in/out-door air pollution in the past Korea. Further this study extensively investigated legal and political changes on air pollution control and management for the last 50 years, and then intensively discussed the present environment-related laws and policies unreasonably enforced in Korea. It is necessary to practically revise many outdated legal policies based on health-oriented thinking and on our current economic levels as well.

Conservative Adjustment of the Standard Calculation Method of Inflow Water Into a Separated Sewer System (분류식 하수관로에서 유입수 표준매뉴얼 산정방법의 보수적 수정 결과)

  • Chu, Minkyeong;Bae, Hyokwan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.5
    • /
    • pp.423-430
    • /
    • 2020
  • To improve the low treatment efficiency of sewage treatment plants, the separated sewer system must be maintained to provide an adequate flow rate and quality of the sewage under the effect of inflow. In this study, data from five locations of Namsuk, Dukgok1, Dukgok2, Kanggu, and Opo were used to conservatively calculate the inflow water volume. The sewer flow and rainfall data were collected in 2017. The factors in the standard method used to calculate the inflow of the combined sewer pipes including "rainy days", "rainfall impact period", and "period for basal sewer" were defined as 3 mm/day, continuous rain for two days, and two weeks prior to the inflow generation, respectively. "Rainy days", "rainfall impact period", and "period for basal sewer" were conservatively adjusted to 5 mm/day, continuous rain for five days, and three weeks prior to the inflow generation, respectively. As a results of the adjustment, the linearity (r2) was improved except for in Dukgok1. This implies that the conservative adjustment made in this study could improve the management quality of sewer pipes. Also, the linear correlation coefficient (ai) between inflow and rainfall showed a large difference between the target locations, which can be another monitoring factor affecting the quality of sewer pipes. To improve the correlation based on the individual characteristics of the locations in Korea, the automatic algorithm for the inflow calculation should be developed by innovative intellectual technologies for application to the entire national area.

Design and Implementation of Hybrid Apps Design based on Spring MVC (스프링 MVC 기반에서 하이브리드 앱 디자인 설계 및 구현)

  • Lee, Myeong-Ho
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.395-400
    • /
    • 2019
  • The Web environment of the frontend domain is increasingly competitive to preempt the new standard of presentation layer. N-Screen, a service that enables users to seamlessly use one content in various devices in Korea, is competing for market preemption by recognizing it as a core service of the future. In the cloud computing, N-screen is a typical service type. However, most of the frontend research required for groupware in enterprise environments has been limited to responsive web design for the web and native apps for mobile. Gradually, the need for MVC design patterns is increasingly widening in enterprise environments to overcome the cultural differences of companies and to support one source multi-use strategy supporting multiple devices and development productivity. Therefore, in this study, we will analyze and design JPetStore with hybrid application design based on Spring MVC, e-government standard framework environment of next generation web standard, and provide reference model of frontend hybrid apps design in future enterprise environment.

Leaching and Acute Toxicity Test of Steel-making Slags for Media Contact Recycling (제강슬래그의 매체접촉형 재활용에 따른 중금속 용출특성 및 물벼룩 생태독성 평가)

  • Donghyun Kim;Bong Seok Cho;Won Sik Shin
    • Journal of Soil and Groundwater Environment
    • /
    • v.29 no.1
    • /
    • pp.72-83
    • /
    • 2024
  • Most of the slags generated from steel-making industry in Korea are recycled into media-contact aggregates such as fill and cover materials. For their use as media-contact aggregates, the slags must meet not only the waste quality criteria, but also the Daphnia magna acute toxicity test criteria. In this study, Korean Leaching Test ES 06150.e (Korea), Japanese Leaching Test JIS K 0058-1(Japan), Detuch Leaching Test DIN 19529 (Germany), Toxicity Characteristic Leaching Procedure (USA) were conducted for batch leaching test of slags from 6 Korean steel-making companies. In addition, Korean Standard up-flow percolation test (ES 06151.1) mimicking field conditions was conducted to assess the impact of the slag leachate on the surrounding environment indirectly. Heavy metals such as Cr6+ and Zn2+ were detected from both extractant and leachate samples, but all of them did not exceed waste quality criteria of each country. However, Daphnia magna acute toxicity tests using the leachate samples from up-flow percolation test with slag alone and slag/natural soil conditions exceeded ecotoxicity standard (TU=2) due to their high pH (11.3-12.5). After neutralizing the pH of the slag leachate to 6.5~8.5, the Daphnia magna mortality and immobilization were reduced to satisfy ecotoxicity standard. As the reducing pH of slag leachate would be extremely difficult, appropriate recycling management considering the physicochemical characteristics of he slags should be stuided further.

Development of u-Health standard terminology and guidelines for terminology standardization (유헬스 표준용어 및 용어 표준화 가이드라인 개발)

  • Lee, Soo-Kyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4056-4066
    • /
    • 2015
  • For understanding of terminology related to u-Health and activating u-Health industry, it is required to develop u-Health standard terminology for communication. The purpose of this study is to develop u-Health standard terminology and provides guidelines for terminology standardization in order to develop the u-Health standard terminology. We finally developed the 187 u-Health standard terminology through the process of data acquisition, term extraction, term refinement, term selection and term management based on reports, glossary and Telecommunications Technology Association (TTA) standards about u-Health. As a result, the standard terminology and guidelines of u-Health optimized to the domestic environment were suggested. They included details of definition, classification, components, the methods and principles of the process for u-Health standard terminology. Presented in this study, u-Health standard terminology and guidelines for terminology standardization would assist the cost-reducing of employing terminology and management of it, while making information transfer easy. This would make possible promoting efficient development of u-Health industry in general.

Quantitative Analysis and Qualification of Amitrole Using LC/ESI-MS (LC/ESI-MS를 이용한 아미트롤의 정성확인 및 정량분석)

  • Park, Chan-Koo;Eo, Soo-Mi;Kim, Min-Young;Sohn, Jong-Ryeul;Mo, Sae-Young
    • Analytical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.117-129
    • /
    • 2004
  • Amitrole in environment, difficult to be analyzed by GC or GC/MS due to high polarity and low volatility, was analyzed by LC/ESI/MS in the study. Maximum peak intensity of amitrole in LC/MS/ESI mass spectrum is m/z 85 of protonated molecular ion $(M+H)^+$ with 30V of cone voltage at SIR mode. It was confirmed that ratios between main ion of amitrole, 85 of protonated molecular ion, and m/z 58 fragmented ion of amitrole, had increased corresponding with the increment of cone voltage from 20V to 70V. The isotope molecular weight of amitrole was $86([M+H])^+$ at LC/MS analysis and the mass spectrum ratio between 85 mass and 86 mass was not different by the change of concentration but similar to theoretical ratio(less than 10% standard deviation).The linearity of standard calibration curve under same condition with sample treatment method had $y=1.09354e^6X+26947.2$ and $r^2=0.99$. Recovery rates in water and soil samples were 77.64~83.44% and 71.11~79.44%, respectively. Reliability of the analysis was performed with 5 repeated measurements at each level of standard concentration and the result showed that relative standard deviation was less than 10%; therefore, the extraction and analysis method in the study suggested that it would be reliable to measure amitrole in water and soil media.

A Design of Press Die Components by Use of 3D CAD Library (3차원 CAD라이브러리를 이용한 프레스 금형 부품의 설계)

  • Park C. H.;Lee S. S.
    • Korean Journal of Computational Design and Engineering
    • /
    • v.9 no.4
    • /
    • pp.373-381
    • /
    • 2004
  • Using standard components of a press die is recognized as a way for a cost reduction and a short lead time. It also provides a way for a quick maintenance of a die under repair. It is expected to contribute to integration of CAD/CAM system for manufacturing dies in the future. This paper presents a 3D CAD library which is constructed using the standard components and is used for designing a press die. This 3D CAD library is generated by a database system made of Microsoft Access for standard components and by CATIA V5 R10 API for geometric features. The library is implemented using Visual Basic 6.0 utility of CATIA API function in the Windows NT environment. It creates a 3D model of the standard components of press die easily when a die designer inputs numerical values of geometric features and the BOM of the completely assembled parts. It also generates automatically the assembly drawing of die set by using variables for standard values of die parts. Therefore users can save the cost of time to design the press die components, and even a beginner can use this program with ease. The test results of the 3D CAD library for designing shearing and bending dies verify its usefulness and feasibility.