• Title/Summary/Keyword: Envelope Remodeling

Search Result 11, Processing Time 0.027 seconds

A Study on the Establish Environmental Impact of Database of the Envelope System for Green Remodeling of Apartment Housing (공동주택의 그린 리모델링을 위한 외피시스템 환경영향 DB 구축에 관한 연구)

  • Lee, Jong Geon;Tae, Sung Ho;Chae, Chang-U;Kim, Rak Hyun
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.73-79
    • /
    • 2016
  • Purpose: In order to improve the energy performance of existing buildings, so actively promoted green remodeling business. Also, improvement of the performance of envelope system of apartment housing is an absolute. The purpose of implementation of the data base and application plan of the envelope system for green remodeling of apartment housing. Method: For this study, It proposed a classification system of green remodeling envelope system constructed actual to select the applicable representative method and input material of apartment housing for green remodeling. In this study, divided into construction waste processing stage and production phase of the material for the boundary of the system, and implementation the classification system of the envelope system for applicable green remodeling. For this, established 6 environmental impact categories database. Result: As a result of various suggestions were available for case study research, alternative combinations of existing combinations than six kinds of environmental impact insulation system with superior input materials combining 96 kinds, window system, 12 kinds for determining the applicability of the established database. Depending on the account for a large proportion if compared to the detailed analysis of the environmental impact resulting from the production phase and disposal phase was analyzed that the operating management of the necessary input materials. Is considered that the economic performance and integrated energy performance required by the applicable public housing green remodeling evaluation techniques considered for future improvements insulation sheath.

A Study on the Non-residential Building Envelope Remodeling for Energy Efficiency (비주거용 건물의 외피 리모델링을 통한 에너지성능향상 방안에 관한 연구)

  • Jang, Hyun-Sook;Lee, Sang-Ho
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.6
    • /
    • pp.3-12
    • /
    • 2012
  • The slowdown of private building industry resulted in growth of remodeling market as a way to improve energy performance. Remodeling is considered more cost-effective and eco-friendly approach for energy efficient building than new construction. Since 2008, Seoul has promoted Building Retrofit Project (BRP) preponderantly to attract energy-saving renovation by supporting building owners to switch building system into energy-saving system when they remodel their old buildings. According to 2012 press release, 254 Private sectors participated in this green building project and annually reduced 41000ton of greenhouse gas emission, 14000TOE, which also result in 7.5 billion won energy cost savings per year. The paper focuses on the building envelope remodeling as a way to improve energy efficiency. Different components of the building envelope such as wall insulation, window, and shading, were applied to the baseline model and the comparison was analyzed to come up with the ideal solution. This study only assesses the building envelope as to suggest the way to redesign the better energy performing building. Offering solution focusing on the architectural feature is essential because it will provide basic information and standard when remodeling a building for energy efficiency, especially, for the nonresidential buildings used as rental offices.

The Energy Saving Effect and Economic Assessment of Office Building according to the Building Envelope Remodeling (사무소 건물의 외피 리모델링에 따른 에너지절감효과 및 경제성 분석)

  • Choi, Seon woo;Kim, Ji Yeon;Park, Hyo soon;Kim, Jun Tae
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.85-92
    • /
    • 2012
  • The Korean government has introduced building regulations with improved energy conservation measures, including higher insulation levels for building envelope. However, there are many existing buildings that tend to consume more energy for heating and cooling than new buildings, as they were built under the former regulations with relatively higher U-values of walls and glazing. In order to improve energy efficiency in existing buildings, green remodelling of building envelope and building services are required. For existing buildings, building services improvements have been achieved through energy service company(ESCO), but much attention has not been paid to building envelope improvements with various reasons, such as uncertainty of energy saving effect design issues and costs. The aim of this study is to evaluate the impact of building envelope improvements in a typical commercial building on its heating and cooling energy loads. The results show that the improvement of glazing with lower U-values has the highest energy saving effects, followed by wall, roof and floor, under the condition of same level of insulation improvements. However, high insulated glazing increased LCC because of higher initial investment costs.

Decision Support Process Model for Energy Efficient Remodeling Projects focused on Building Envelope and Renewable-energy Systems (에너지절감형 리모델링을 위한 적정 대안 선정 프로세스 모델 - 건축물 외피 및 신재생에너지 시스템을 중심으로 -)

  • Shin, Young-su;Cho, Kyuman;Kim, Jae-youn
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.91-100
    • /
    • 2015
  • An increase in energy such as natural gas, coal, oil, has occurred to a large amounts of environment impact emissions, it is necessary to reduce in the construction industry for the energy consumption. To encourage remodeling project in developed countries of the majority, on the basis of this, remodeling project in the construction industry has grown to a large amount. Results of analysis of the research related to the advanced remodeling, analysis of the economic validity in accordance with the production and process and building elapsed years of selection alternative of remodeling there has been a problem that has not been properly reflected. In this study, a decision support model that can simultaneously choose the most cost-effective and energy-efficiency alternative. Developed process model, generates a "Remodeling Solution" that combines the renewable energy equipment and envelope system, energy performance evaluation of the application of international standards(ISO-13790, DIN V 18599), perform the economic evaluation through LCCA(Life Cycle Cost Analysis) technique, circulated evaluation and configured to output the optimal Remodeling Solution. The results of applying the model developed in the case, it was confirmed that it is possible to select a choice of cost-effective energy-saving alternative. Then, developed model through this study, it is expected to be able to help highly effective remodeling alternative to selecting by decision-makers.

Optimum Method of Windows Remodeling of Existing Residential according to the Window Properties and Window Wall Ratio (창호의 성능 및 건물의 창면적비에 따른 기존 단독주택의 창호 리모델링 방안 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jeong, Hak-Geun;Kim, Jong-Hun;Jang, Cheol-Yong
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.71-78
    • /
    • 2013
  • A need for building energy efficiency is on the issue since energy demand in the building stock in Korea represents about 24% of the final energy consumption. As a way of improving the thermal performance of buildings for reducing maintenance costs and environmental conservation, a lot of effort is shown to improve the building energy efficiency by applying improvement of envelope insulation performance for buildings whose energy efficiency is low relatively through the remodeling. The windows of building envelopes are areas that lead to the biggest heat loss in the building. So windows are considered to be the primary target of energy efficiency in remodeling and various studies for windows have been done. Currently, however, only U-factor and airtightness of windows performance are regulated. Window wall ratio(WWR) and solar heat gain coefficient(SHGC) of windows are not considered when conducting the remodeling. In this study appropriate performance of windows(U-factor and SHGC) for existing residential is proposed according to the window wall ratio by using EnergyPlus. As the results of this study, the U-factor of windows representing the maximum energy savings is $1.0W/m^2K$ but in case of SHGC, the values that indicate the maximum energy savings are different depending on the window wall ratio. Therefore, when conducting the remodeling of windows, to determine energy efficiency by considering only the U-factor is inadequate so it is necessary that appropriate windows are applied to buildings by considering window wall ratio and windows properties(U-factor and SHGC).

Insulation Performance Evaluation of Apartment Housing Using Infra-red Camera (적외선 열화상을 이용한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 -)

  • Choi, Bo-Hye;Choi, Gyoung-Seok;Kang, Jae-Sik;Lee, Seung-Eon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.718-723
    • /
    • 2009
  • The purpose of this study is to present an in-site evaluation method for building insulation performance using Infra-red camera. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature & heat flow pattern analyze method. By establishing the in-site evaluation method building insulation performance using infra-red camera, it is expected that 1) building envelope repair market will be activated by using developed method in ESCO and remodeling companies, 2) the method developed in this research will contribute to reduce national energy consumption by promoting old building insulation remodeling.

  • PDF

Energy Performance Evaluation Study on the Thermal Bridge Blocking External Insulation System for Green Remodeling (그린 리모델링용 열교 차단 외단열 시스템의 에너지 성능 평가 연구)

  • Kim, Woong-Hoi;Kang, Eun-Ho;Yoon, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.234-235
    • /
    • 2021
  • We set the representative balcony types of the existed building to two types: unexpanded balcony and extended balcony, and analyze the effect of reducing the cooling and heating energy load when applying remodeling. The scope of the study was limited to balcony walls, including window-wall junctions, and was conducted by comparing cases with and without thermal break insulation structures for a clear conclusion. The study was conducted using the equivalent U-value in each case. The equivalent U-value was calculated by deriving through 2 dimensional steady-state heat transfer analysis of each case balcony envelope. And building energy was calculated using the derived equivalent U-value. According to the calculation results, for unexpanded balconies, the equivalent U-value was reduced by about 80%, and the heating and cooling load was reduced by about 20%. In the case of extended balconies, the equivalent U-value was reduced by about 57% and the resulting heating and cooling load was reduced by about 12%.

  • PDF

The Improvement of Building Envelope Performance in Existing School Building (기존 학교 건물의 외피 성능 개선 방안에 관한 연구)

  • Bang, Ah-Young;Park, Se-Hyeon;Kim, Jin-Hee;Kim, Young-Jae;Kim, Jun-Tae
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: This study is to investigate the effects of facade insulation and window remodeling of an existing old middle school building on the reduction of energy consumption. Method: To analyze energy performance of building, using DesignBuilder v3.4, building energy simulation tool based EnergyPlus engine. Energy consumption and problem of target building was analyzed based on data and survey. Based on building energy simulations it analyzed the variation of energy demand for the building according to U-value of wall, glazing properties and external shading devices. Result: When insulation of building was reinforced, cooling and heating load was decreased. Glazing properties that minimize cooling and heating energy consumption were analyzed. In conclusion, it is important to choose SHGC and U-value of window fit in characteristic of target building. Setting external blind for cooling load decreases 5%.

Energy Saving Effects of Green Roof in Exiting Buildings according to Different Insulation Levels (기존 노후 건물의 단열 성능에 따른 옥상 녹화 시스템 설치시 에너지 성능 변화)

  • An, Kyeong A;Han, Seung Won;Moon, Hyeun Jun
    • Journal of Korean Living Environment System
    • /
    • v.21 no.6
    • /
    • pp.959-964
    • /
    • 2014
  • Energy performance of building envelope components, including external walls, floors, roofs, windows and doors, is crutial for determining how much energy is required for heating and cooling in a building. Among various building technologies, a green roof system can be a good option for reducing heat gain and loss in new buildings as well as existing buildings for green remodeling. This paper evaluates the performance of green roof systems according to soil depth and Leaf Area Index (LAI) for existing buildings. It also attempts to quantify the energy saving effects on new and existing buildings with different insulation levels. Thermal performance of green roofs is mainly dependent on soil thickness and LAI. Installation of green roofs in deteriorated existing buildings can lead to improvements in roof insulation, due to the soil layer. An increase in soil depth leads to a decrease in heating load, regardless of conditions of vegetation on the green roof. Larger LAI values may reduce cooling loads in the cooling season. Installation of green roof in deteriorated existing buildings showed bigger energy saving effect in comparison to a case in new buildings. A simulation study showed that the installation of green roof systems in deteriorated existing buildings with low insulation levels, due to low thermal performance requirements when constructed, could improve the energy performance of the buildings similar or better to the peformance on new buildings with the most updated insulation standard. Thus, when remodeling a deteriorated building, green roofs could be a good option to meet the most recent energy requirements.

Measurement of Residential Volatile Organic Compound Exposure Through A Participant-Based Method (연구참여자에 의한 주택실내 휘발성 유기화합물 농도의 측정)

  • Hwang, Yun-Hyung;Lee, Ki-Young;Kim, Seo-Jin;Hong, Yun-Chul;Jun, Jong-Kwan;Cho, Soo-Hun
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.5
    • /
    • pp.369-375
    • /
    • 2011
  • Objectives: Exposure to hazardous chemicals during pregnancy may result incritical reproductive health outcomes. Indoor residential levels are significant component of personal exposure. The collection of residential exposure data has been hampered by the cost and participant burden of health studies of indoor air pollution. This study utilized a participant-based approach to collect volatile organic compounds concentration from homes. Methods: Four hundred thirteen women were recruited from three major hospitals in Seoul and Gyeongi Provence and 411 agreed to participate. A passive sampler (OVM 3500, 3M, USA) with instructions were given to the participants, as well as a questionnaire. They were asked to deploy the sampler in their homes for three to five days and return them viapre-stamped envelope. Results: Three hundred forty six participants returned the sampler. Among the returned samplers, three hundred samplers satisfied our monitoring quality criteria. The success rate of the monitoring method was 73%. The geometric mean of TVOC level was 429(2) ${\mu}g/m^3$. The TVOC guideline of 500 ${\mu}g/m^3$ was exceeded in 38% of the houses. The residential VOC levels were significantly associated with remodeling of the house. Conclusions: The results suggested that a participant-based sampling approach may be a feasible and costeffective alternative to exposure assessment involving home visits by a field technician.