• Title/Summary/Keyword: Entrance number

Search Result 333, Processing Time 0.026 seconds

NUMERICAL STUDY OF NANOFLUIDS FORCED CONVECTION IN CIRCULAR TUBES (원형관내 나노유체의 강제대류에 관한 수치적 연구)

  • Choi, Hoon Ki;Yoo, Geun Jong
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.37-43
    • /
    • 2014
  • In this paper, hydraulic & thermal developing and fully developed laminar forced convection flow of a water-$Al_2O_3$ nanofluid in a circular horizontal tube with uniform heat flux at the wall, are investigated numerically. A single phase model employed with temperature independent properties. The thermal entrance length is presented in this paper. The variations of the convective heat transfer coefficient and shear stress are shown in the entrance region and fully developed region along different nanoparticles concentration and Reynolds numbers. Convective heat transfer coefficient for nanofluids is larger than that of the base fluid. It is shown that heat transfer is enhanced and shear stress is increased as the particle volume concentration increases. The heat transfer improves, as Reynolds number increases.

A Study on State Residents' Use at Three Rest Areas and Three Playgrounds in an Apartment Complex (아파트 단지내 휴게시설 및 어린이 놀이터 이용실태에 관한 연구)

  • 최재순;이지숙
    • Journal of the Korean housing association
    • /
    • v.10 no.2
    • /
    • pp.155-163
    • /
    • 1999
  • The purpose of this study was to investigate the residents' actual usage at three rest areas and three playgrounds in an apartment complex. This study was conducted with field study in J apartment complex in Incheon from August 14 to August 30, 1998. According to the results of the study, there were more users in playgrounds than in the rest areas. The rest area near the place for the elderly in the complex was used mainly by the elderly females. The playground located near the main entrance of the complex was frequently used because it is the biggest one in size and has an enough space for playing. Furthermore, the condition of shading areas by trees and buildings influenced the rate of use of the residents. Therefore, to increase the usage rate of rest areas and playgrounds, they should be located near to the places which have community amenities and should have accessible entrance for residents. Landscape design of the apartment complex should be done with the plot plan of the complex simultaneously. Moreover, the number and the kinds of trees to be planted in the apartment complex should be considered carefully.

  • PDF

Sound Propagation through the Diesel Particulate Filter (DPF) (디젤 매연여과기 (DPF) 내에서의 음향전파)

  • Choi, Won-Yong;Ih, Jeong-Guan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11b
    • /
    • pp.152-155
    • /
    • 2005
  • Diesel particulate filter (DPF) is comprised of a number of capillary tubes enclosed by porous ceramic wails, shaped like a plugged duct. Hot gas flows through the DPF along with the exhaust noise from Diesel engine. Based on previous works on the sound propagation through DPF, in this study, losses at entrance, exit, and ceramic walls are considered and the gradients in temperature and flow velocity are considered. Transfer matrix at entrance, monolith, and exit parts are obtained by employing the segmental approach in analyzing the sound propagation through DPF. The predicted transmission loss agrees very well with the empirical one, which is measured by the improved method with correction terms.

  • PDF

A Study on Flow Characteristics of the Entrance Region of Wavy Channel by PIV (PIV를 이용한 파형채널 입구영역의 유동특성에 관한 연구)

  • Lee, Cheol-Jae;Cho, Dae-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.912-917
    • /
    • 2009
  • An experimental flow visualization study of the entrance section of channels formed with wavy plates was made. The experiments were conducted in a water channel and a laser illuminated particle tracking was used as the technique of flow visualization. The flow region that were found in the experiments are steady, unsteady and significantly-mixed flows. Instabilities of the flow first appear near the exit of the channel. As the Reynolds number increases, the flows are characterized by the appearance of flow separation and the growth of recirculation region.

An Analysis of the Space Size in the Apartment Unit Plan (공동주택 단위평면의 실별 면적 분석)

  • Lee, Kyung-A;Park, So-Yun;Lee, Hyun-Soo
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2005.10a
    • /
    • pp.52-55
    • /
    • 2005
  • The purpose of this study is to analyze space size in the apartment unit plan towards optimal space configuration in order to offer the helpful information to housing designers. For this, we analyzed 432 samples using the Excel 2003 program. The major results of this study are as follows. 1) as the unit size gets bigger, the proportion of the usable area is increased. 2) as the unit size gets bigger, the number of spaces is increased and spaces are divided although they have the same function. 3) living room has the highest proportion in each unit, master room and kitchen are followed. 4) the proportion of living room, kitchen and entrance hall is not fluctuated while that of bedroom and bathroom is decreased. 5) there is a big gap between maximum size and minimum size of kitchen, entrance hall, bathroom and dressing room.

  • PDF

Entrance Skin Dose and Image Quality Evaluation According to Use Grid Radiography for the Extremity in FPD System (FPD System에서 상.하지 촬영 시 격자에 따른 환자 선량 및 화질 평가)

  • Lee, In-Ja;Yeo, Young-Bok;Lee, Tae-Sung
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • By accessing the current status of FPD system use in the hospitals located in Seoul and Gyeonggi Province as well as the entrance skin dose and the image quality evaluation realized by C-D Phantom, and the image assessment by the medical professionals regarding the radiography for the extremity, the following results were derived. 1. According to the evaluation made in the actual use of FPD system (12 machines), the grid ratio varied from 8:1 to 13:1, and 6 machines used the grid ratio with 12:1, realizing the largest number. Among the machines, there were 8 machines that allowed a removable grid while 3 machines did use a removable grid (25.0%). 2. When it came to the equipments used for the experiment, it showed that the amount of the entrance skin dose increased from 4.13 times up to 4.79 times with the grid use. 3. The difference in the entrance skin dose depending on the changes in the exposure condition(0.5times or 2.0times) was not significantly different regardless of the patients' thickness. 4. In terms of the image quality depending on C-D Phantom, the grid use was distinguished well. However, the images were well distinguishable as the exposure condition got increased. 5. In the clinical assessment, the grid use was less effective for the Hand PA, which was considered to shoot a thin body part. It was evaluated that the grid use was preferred for the Knee AP, which was shooting for a relatively thick body part. Nonetheless, 3 out of 5 people said that they would not use the grid if the entrance skin dose to reduced.

Influence of the Entrance and Exit Lengths on the Natural Convection Heat Transfer of a Cylinder in a Duct (도관내 원형관의 자연대류 열전달에서 입구 및 출구 길이 효과)

  • Lim, Chul-Kyu;Chung, Bum-Jin
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.18-25
    • /
    • 2012
  • This work investigated the influence of the chimney dimensions(exit and entrance length, and diameter) on the heat transfer of a vertical cylinder in a duct. The measured mass transfer rates for the natural convection of vertical cylinder in a duct were presented for Prandlt number 2,094, Rayleigh number in the range of $4.55{\times}10^9$, $5.79{\times}10^{10}$, and $1.69{\times}10^{11}$. Experiments were performed using a copper sulfate electroplating system to simulate heat transfer based upon the analogy concept. The diameter of the duct was varied from 0.06 m to 0.14 m, and the heights from 0.30 m to 1.10 m. Nusselt numbers measured at open channel condition agreed well with the existing laminar heat transfer correlations for vertical plate developed by Le Fevre. The increase of the exit length enhanced the heat transfer up to a certain duct height but further increase does not affects the heat transfer. The heat transfer decreased with increasing the entrance length up to a certain duct height and was constant at further increase. The Nusselt number decreased with increasing the diameter of duct, until Nusselt number becomes similar to that at open channel beyond a certain diameter.

A Study on the Inlet Pressure Build-Up at Bearing Entrance (베어링 입구에서 발생하는 선단압력에 관한 연구)

  • 김종수;김경웅
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.8
    • /
    • pp.1921-1930
    • /
    • 1993
  • In order to evaluate the inlet pressure correctly, the full Navier-Stokes equations are solved numerically for the computational domain which covers the cavity region between pads as well as the bearing film. A nonuiform grid system is adopted to reduce the number of grid points, and the numerical solutions are obtained for a wide range of Reynolds number in laminar regime with various values of the distance between pads. The numerical results show that the inlet pressure is significantly affected by Reynolds number and the distance between pads. An expression for the loss coefficient in terms of Reynolds number and non-dimensional distance between pads is obtained on the basis of the numerical results. It is found that the inlet pressure over the whole range of numerical solutions can be fairly accurately estimated by applying the formula for the loss coefficient to the extended Bernoulli equation.

The Behaviour of Shrimp , Palaeman Pacificus , to the Model Trap and the Odour of Baits (함정어구와 미끼에 대한 태평줄 새우)

  • Ko, Kwan-Soh;Kim, Yong-Hae
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.19 no.2
    • /
    • pp.85-91
    • /
    • 1983
  • The behaviour of shrimp in response to the trap was much influenced by the type, size and the dimensions of entrance as well as physiological and ecological conditions. The entry and the escape behaviour of shrimp to the model trap were observed in accordance with netting materials, baits, type and slope of entrance, and gathering response were also investigated on the odour of bait extracts in the aquarium from June to August, 1983. Entering shrimp to the circular entrance was significantly more than to the triangular or the square; however, no differences were found in the entry behacior among netting materials i e., P. A, P. E. and cotton. According as the slope of entrance was increased its angle from 0$^{\circ}$ to 90$^{\circ}$, number of entering shrimp was decreased; however, number of escaping shrimp at 30$^{\circ}$or 60$^{\circ}$ with time was fewer than at 0$^{\circ}$ or 90$^{\circ}$. Gathering responses of shrimp on the odours were more sensitive to the flesh of mackerel or the shrimp than to the pickled anchovy, or the pettitioes, while no differences were found between another bait extracts, i e., the shrimp and the flesh of mackerel, the short-necked clam and the horse mackerel, the flesh and the viscera of mackerel.

  • PDF

Analysis of Turbulent Heat Transfer in a Concentric Annular Pipe with Artificial Roughness (人工조도 가 있는 二重同心圓管 의 亂流 熱傳達 解析)

  • 홍진관;이기만;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.7 no.3
    • /
    • pp.301-312
    • /
    • 1983
  • Experimental results for the variation of the flow characteristics and heat transfer coefficients in the entrance region of concentric annular pipe with artificial roughness are compared with the theoretical results by numerical analysis. In the experiments, velocity profiles, pressure gradients and heat transfer coefficients were measured with variation of the Reynolds number for the constant ratio of pitch to height at the hydrodynamic entry region. Wall temperature of inner heated pipe with constant heat flux was measured at thermal entry region after the hydrodynamically fully developed region of flow. Experimental data agree well with numerical predictions. Both results show that turbulent flow of annular pipe with artificial roughness is fully developed thermally much faster than that of smooth pipe. Nusselt number of annular pipe with roughness is much higher than that of smooth pipe. However the ratios of Nusselt number of annular pipe with artificial roughness to that of smooth pipe does not vary with Reynolds number.