• Title/Summary/Keyword: Enthalpy method

Search Result 247, Processing Time 0.026 seconds

Numerical study for performance analysis and design of a counterflow type cooling tower (대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구)

  • 이상윤;이정희;최영기;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

Thermal-flow Analysis of the Cooling System in the Medicated Water Electrolysis Apparatus (냉이온수기 냉각시스템에 관한 열유동 해석)

  • Jeon, Seong-Oh;Lee, Sang-Jun;Lee, Jong-Chul;Kim, Youn-Jea
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.3
    • /
    • pp.33-38
    • /
    • 2011
  • Medicated water electrolysis apparatus, which electrolyzes water into acidic water and alkaline water, was in the spotlight as becoming known the effect of alkaline water. It is known as good for health as removing active oxygen in the human's body and promoting digestion. But, the customers could not get that desired water temperature because these apparatuses are directly connected with a water pipe. So, the cooling system was developed for controlling the temperature of the alkaline water. One of the typical way is to store water in water tank and control the temperature. But, in this way, storing water can be polluted impurities coming from outside. For protecting this pollution, the cooling system based on indirect heat exchange method through phase change between water and ice was developed. In this study, we have calculated efficiency of the cooling system with phase change by experiment and commercial CFD(Computational Fluid Dynamics) code, ANSYS CFX. To consider the effect of latent heat that is generated by melting ice, we have simulated two phase numerical analyses used enthalpy method and found the temperature, velocity, and ice mass distribution for calculating the efficiency of cooling. From the results of numerical analysis, we have obtained the relationship between the cooling efficiency and each design factor.

Enthalpy Changes of Adsorption of Tetrafluorocarbon (CF4) and Hexafluoroethane (C2F6) on Activated Carbon

  • Shin, Jiyoung;Suh, Sung-Sup;Choi, Moon Kyu
    • Clean Technology
    • /
    • v.20 no.1
    • /
    • pp.22-27
    • /
    • 2014
  • Under low pressures of $CF_4$ and $C_2F_6$ up to 20.7 kPa, the equilibrium adsorbed quantity on activated carbon was experimentally examined using the volumetric method at various temperatures between 293.15 K and 333.15 K. To give the best fit to the experimental data curve, the two step model (i.e., Langmuir model for the first layer adsorption and then Freundlich physisorption) is suggested. The method of initial slope yielded the enthalpy of adsorption for the first step while we could apply the Clausius-Clapeyron equation to find the heat of adsorption of the second step. They are 25.9 kJ/mol and 11.8 kJ/mol, respectively, with $CF_4$, and 38.7 and 38.2 kJ/mol with $C_2F_6$.

Determination and Temperature Dependence of n-Octanol/Water Partition Coefficients for Seven Sulfonamides from (298.15 to 333.15) K

  • Congliang, Zhang;Yan, Wang;Fuan, Wang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.7
    • /
    • pp.1183-1186
    • /
    • 2007
  • A shake-flask method was used to determine the n-octanol/water partition coefficients of sulfamethazine, sulfadimethoxine, sulfamethoxydiazine, sulfamonomethoxine, sulfamethoxazole, sulfaquinoxaline and sulfachloropyrazine from (298.15 to 333.15) K. The results showed that the n-octanol/water partition coefficient of each sulfonamide decreased with the increase of temperature. Based on the fluid phase equilibrium theory, the thermodynamic relationship of n-octanol/water partition coefficient depending on the temperature is proposed, and the changes of enthalpy, entropy, and the Gibbs free energy function for sulfonamides partitioning in n-octanol/ water are determined, respectively. Sulfonamides molecules partitioning in n-octanol/water is mainly an enthalpy driving process, during which the order degrees of system increased. The temperature effect coefficient of n-octanol/water partition coefficient is discussed. The results show that its magnitude is the same as that of values in the literature.

Finite Element Analysis of Compression Holding Step Considering Solidification for Semi-Solid Forging (반용융 단조에서 응고 현상을 고려한 가압유지 단계의 유한요소해석)

  • 최재찬;박형진;조해용
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.597-601
    • /
    • 1997
  • The technology of Semi-Solid Forging(SSF) has been actively developed to fabricate near-net shape products using light and hardly formable materials. Generally, the SSF process is composed of slug heating,forming,compression holding and ejecting step. After forming step in SSF, the slug is comperssed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. This paper presents the analysis of temperature,solid fraction and shrinkage at compression holding step for a cylindrical slug,then predicts the solidification time to obtain the final shaped part. Enthalpy-based finite element analysis is performed to solve the heat transfer problem considering phase change in solidification.

  • PDF

Finite Element Analysis of Compression Holding step Considering Solidification for Semi-Solid Forging (반용융 단조에서 응고 현상을 고려한 가압유지 단계의 유한요소해석)

  • Park, J.C.;Park, H.J.;Cho, H.Y.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.102-108
    • /
    • 1997
  • The technology of Semi-Solid Forging (SSF) has been actively developed to fabricate near-net- shape products using light and hardly formable materials. Generally, the SSF process is composed of slug heating, forming, compression holding and ejecting step. After forming step in SSF, the slug is compressed during a certain holding time in order to be completely filled in the die cavity and be accelerated in solidification rate. This paper presents the analysis of temperature, solid fraction and shrinkage at compression holding step for a cylindrical slug, then predicts the solidification time to obtain the final shaped part. Enthalpy-based finite element analysis is performed to solve the heat transfer problem considering phase change in solidification.

  • PDF

The Pressure Effect on the Ionization of m-Chloroanilinium Ion in Sodiumacetate Buffer Solution

  • Jee ,Jong-Gi;Lee, Young-Hwa;Kwak, Young-Jik
    • Bulletin of the Korean Chemical Society
    • /
    • v.6 no.5
    • /
    • pp.266-269
    • /
    • 1985
  • The dissociation constants(K) of m-chloroanilinium ion in water-ethanol mixture, where the volume percentage of water is 89.5%, were evaluated by UV-spectroscopic method at $20{\sim}50^{\circ}C$, up to 1500 bars with changing ionic strength from 0.04 to 0.10 mol $kg^{-1}$ by use of acetate buffer. K values enhance with increasing ionic strength and temperature, but decrease with elevating pressure. From K values, we obtained the partial molar volume change and some other thermodynamic parameters. From the values of enthalpy, entropy and isoequilibrium temperature (649 K), we concluded that the dissociation of m-chloroanilinium ion mentioned above is controlled by enthalpy.

Interaction of Pharmaceuticals with Betacyclodextrin I -Interaction with Sulfonamides- (Batacyclodextrin과 의약품과의 상호 반응 I -Sulfonamides와 Betayclodextrin과의 상호 반응-)

  • 민신홍
    • YAKHAK HOEJI
    • /
    • v.15 no.1
    • /
    • pp.8-15
    • /
    • 1971
  • Betacyclodextrin 과 수종의 sulfonamide와의 상호반응을 solubility method로 고찰하였다. 본실험에서 사용한 betacyclodextrin의 농도 범위에서는 sulfonamide의 solubility 증가와 batacyclodextrin의 농도와의 관계 함수관계에 있음을 나타내었다.열역학적인 해석을 시도하여 본반응의 formation constant, free energy, enthalpy 및 entropy를 개측하였다.

  • PDF

Numerical Analysis of Melting Process in a Water Tank for Fuel-cell Vehicles (연료전지 자동차의 물탱크 해빙과정에 대한 수치해석적 연구)

  • Kim, Hark-Koo;Jeong, Si-Young;Hur, Nahm-Keon;Lim, Tae-Won;Park, Yong-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.585-592
    • /
    • 2007
  • Good cold start characteristics are essential for satisfactory operation of fuel cell vehicles. In this study, the melting process has been numerically investigated for a water tank used in fuel cell vehicles. The 2-D model of the tank containing ice and plate heaters was assumed and the unsteady melting process of the ice was calculated. The enthalpy method was used for the description of the melting process, and a FVM code was used to solve the problem. The feasibility study compared with other experiment showed that the developed program was able to describe the melting process well. From the numerical analysis carried out for different wall temperatures of the pate heaters, some important design factors could be found such as local overheating and pressurization in the tank.