• 제목/요약/키워드: Engineering stress-strain curve

검색결과 375건 처리시간 0.03초

Bond slip modelling and its effect on numerical analysis of blast-induced responses of RC columns

  • Shi, Yanchao;Li, Zhong-Xian;Hao, Hong
    • Structural Engineering and Mechanics
    • /
    • 제32권2호
    • /
    • pp.251-267
    • /
    • 2009
  • Reinforced concrete (RC) structures consist of two different materials: concrete and steel bar. The stress transfer behaviour between the two materials through bond plays an important role in the load-carrying capacity of RC structures, especially when they subject to lateral load such as blast and seismic load. Therefore, bond and slip between concrete and reinforcement bar will affect the response of RC structures under such loads. However, in most numerical analyses of blast-induced structural responses, the perfect bond between concrete and steel bar is often assumed. The main reason is that it is very difficult to model bond slip in the commercial finite element software, especially in hydrodynamic codes. In the present study, a one-dimensional slide line contact model in LS-DYNA for modeling sliding of rebar along a string of concrete nodes is creatively used to model the bond slip between concrete and steel bars in RC structures. In order to model the bond slip accurately, a new approach to define the parameters of the one-dimensional slide line model from common pullout test data is proposed. Reliability and accuracy of the proposed approach and the one-dimensional slide line in modelling the bond slip between concrete and steel bar are demonstrated through comparison of numerical results and experimental data. A case study is then carried out to investigate the bond slip effect on numerical analysis of blast-induced responses of a RC column. Parametric studies are also conducted to investigate the effect of bond shear modulus, maximum elastic slip strain, and damage curve exponential coefficient on blast-induced response of RC columns. Finally, recommendations are given for modelling the bond slip in numerical analysis of blast-induced responses of RC columns.

Buckling resistance behavior of WGJ420 fire-resistant weathering steel columns under fire

  • Yiran Wu;Xianglin Yu;Yongjiu Shi;Yonglei Xu;Huiyong Ban
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.269-287
    • /
    • 2023
  • The WGJ420 fire-resistant weathering (FRW) steel is developed and manufactured with standard yield strength of 420 MPa at room temperature, which is expected to significantly enhance the performance of steel structures with excellent fire and corrosion resistances, strong seismic capacity, high strength and ductility, good resilience and robustness. In this paper, the mechanical properties of FRW steel plates and buckling behavior of columns are investigated through tests at elevated temperatures. The stress-strain curves, mechanical properties of FRW steel such as modulus of elasticity, proof strength, tensile strength, as well as corresponding reduction factors are obtained and discussed. The recommended constitutive model based on the Ramberg-Osgood relationship, as well as the relevant formulas for mechanical properties are proposed, which provide fundamental mechanical parameters and references. A total of 12 FRW steel welded I-section columns with different slenderness ratios and buckling load ratios are tested under standard fire to understand the global buckling behavior in-depth. The influences of boundary conditions on the buckling failure modes as well as the critical temperatures are also investigated. In addition, the temperature distributions at different sections/locations of the columns are obtained. It is found that the buckling deformation curve can be divided into four stages: initial expansion stage, stable stage, compression stage and failure stage. The fire test results concluded that the residual buckling capacities of FRW steel columns are substantially higher than the conventional steel columns at elevated temperatures. Furthermore, the numerical results show good agreement with the fire test results in terms of the critical temperature and maximum axial elongation. Finally, the critical temperatures between the numerical results and various code/standard curves (GB 51249, Eurocode 3, AS 4100, BS 5950 and AISC) are compared and verified both in the buckling resistance domain and in the temperature domain. It is demonstrated that the FRW steel columns have sufficient safety redundancy for fire resistance when they are designed according to current codes or standards.

상온과 343℃에서 Alloy 690TT 증기발생기 전열관의 인장물성치 평가 (Evaluation of Tensile Properties of Alloy 690TT Steam Generator Tube at Room Temperature and 343℃)

  • 엄기현;김진원
    • 대한기계학회논문집A
    • /
    • 제38권6호
    • /
    • pp.655-662
    • /
    • 2014
  • 본 논문에서는 상온과 원전 설계온도에서 증기발생기 전열관의 축방향과 원주방향 응력-변형률 거동과 인장물성치를 파악하기 위해서, 튜브 시편과 링 시편을 이용하여 상온과 $343^{\circ}C$에서 Alloy 690TT 전열관에 대한 인장시험을 수행하였다. 축방향 인장시험 결과 상온과 $343^{\circ}C$에서 모두 항복점 현상이 관찰되었으며, $343^{\circ}C$에서는 Serration이 관찰되었다. 축방향과 원주방향 모두 상온에 비해 $343^{\circ}C$에서 강도는 감소하였으나 연신율은 거의 변화가 없었다. $343^{\circ}C$에서 가공경화율은 상온에 비해 약간 감소하였으나, 가공경화 거동의 변화는 없었다. 시험 온도에 관계없이 축방향에 비해 원주방향의 항복강도와 인장강도가 약 5 10% 정도 낮았다. 시편 방향에 관계없이 상온 대비 $343^{\circ}C$에서 Alloy 690TT 전열관의 항복강도와 인장강도 감소는 ASME Sec.II의 온도 보정계수에 의해 예측된 것보다 큰 것으로 확인되었다.

5083 Al합금 용접재의 조직 및 저온 인장성질메 미치는 시효처리의 영향 (Effect of Aging Treatment on the Microstructure and Low Temperature Tensile Properties in 5083 Aluminum Alloy Weldments)

  • 이태청;이해우;주동원;이준희;성장현
    • 열처리공학회지
    • /
    • 제13권1호
    • /
    • pp.1-9
    • /
    • 2000
  • The microstructural characteristics and low temperature tensile properties between $25^{\circ}C$ and $-196^{\circ}C$ for as-welded and age hardened specimen by using Al 5083-H321 for base metal, 5083-5356 and 5083-4043 weldments have been investigated. The hardness of 5083-5356 weldment decreases with aging treatment, whereas the weld region of 5083-4043 weldment shows remarkable increase in hardness after aging due to the precipitation of fine Si particle at the grain boundaries and interiors. Low temperature tensile properties of 5083 AI base metal, 5083-5356 and 5083-4043 weldments appear to be the increment of tensile strengths and elongations at the room temperature and $-196^{\circ}C$, while the decrement of tensile properties around $-50^{\circ}C$ is shown. Through the observation of fine serration to fracture in the stress-strain curve and tensile fractography, the increment of localized deformation leading to promote the neck initiation and the increment of the dimple size cause to decrease in tensile strengths and elongations around $-50^{\circ}C$. For the tensile specimen of the 5083 base metal, 5083-5356 and 5083-4043 weldments, the reason to increase in elongation after solution and aging treatment is the diminishment of fine pit, the resolution of Mg into the matrix and the spheridization of the eutectic Si.

  • PDF

New emerging surface treatment of GFRP Hybrid bar for stronger durability of concrete structures

  • Park, Cheolwoo;Park, Younghwan;Kim, Seungwon;Ju, Minkwan
    • Smart Structures and Systems
    • /
    • 제17권4호
    • /
    • pp.593-610
    • /
    • 2016
  • In this study, an innovative and smart glass fiber-reinforced polymer (GFRP) hybrid bar was developed for stronger durability of concrete structures. As comparing with the conventional GFRP bar, the smart GFRP Hybrid bar can promise to enhance the modulus of elasticity so that it makes the cracking reduced than the case when the conventional GFRP bar is used. Besides, the GFRP Hybrid bar can effectively resist the corrosion of conventional steel bar by the GFRP outer surface on the steel bar. In order to verify the bond performance of the GFRP hybrid bar for structural reinforcement, uniaxial pull-out test was conducted. The variables were the bar diameter and the number of strands and pitch of the fiber ribs. Tensile tests showed a excellent increase in the modulus of elasticity, 152.1 GPa, as compared to that of the pure GFRP bar (50 GPa). The stress-strain curve was bi-linear, so that the ductile performance could be obtained. For the bond test, the entire GFRP hybrid bar test specimens failed in concrete splitting due to higher shear strength resulting in concrete crushing as a function of bar deformation. Investigation revealed that an increase in the number of strands of fiber ribs enhanced the bond strength, and the pitch guaranteed the bond strength of 19.1 mm diameter hybrid bar with 15.9 mm diameter of core section of deformed steel the ACI 440 1R-15 equation is regarded as more suitable for predicting the bond strength of GFRP hybrid bars, whereas the CSA S806-12 prediction is considered too conservative and is largely influenced by the bar diameter. For further study, various geometrical and material properties such as concrete cover, cross-sectional ratio, and surface treatment should be considered.

PBA/PS 코어-셀 압력가소성 고분자와 실리카 나노입자의 블렌딩 (Blending of Silica Nanoparticles with PBA/PS Core-Shell Baroplastic Polymers)

  • 김민정;최용두;류상욱
    • 폴리머
    • /
    • 제32권6호
    • /
    • pp.573-579
    • /
    • 2008
  • 두 단계 에멀젼 중합을 통해 PBA/PS 코어-셸 고분자 나노입자 및 실리카가 함유된 유기-무기 하이브리드 재료를 합성하였다. 실리카 나노입자는 코어-셸 고분자 에멀젼과 혼합되어 $Na_2CO_3$가 녹아있는 증류수/메탄올의 혼합용매에 침전되었다. 건조 후 압축성형으로 제조된 시편의 물성평가를 통해 탄성계수는 코어-셸 나노입자의 크기가 작을수록, 분자량이 클수록, 실리카가 많이 첨가될수록 증가함을 확인하였다. 또한 PBA/PS 코어-셸 고분자는 실리카가 13.0 wt% 첨가되었음에도 불구하고 25$^\circ$C, 13.8 MPa, 5분의 조건에서 우수한 압력가소성 특징을 나타내었으며 6배 이상 증가된 탄성계수가 얻어졌다.

실내시험 및 현장시험을 통한 지반의 비선형 변형특성 평가 (Evaluation of Nonlinear Deformational Characteristics of Soils from Laboratory and Field Tests)

  • 김동수;권기철
    • 한국지반공학회지:지반
    • /
    • 제13권5호
    • /
    • pp.89-100
    • /
    • 1997
  • 토목구조물의 동적해석 뿐아니라 공용상태 구조물 기초의 변형해석을 위해서는 지반의 신뢰성 있는 비선형 변형특성 평가가 매우 중요하다. 변형특성 평가를 위한 현장시험으로는 저변형률 하에서 지반의 탄성계수를 결정할 수 있는 크로스흘시험이나 중간변형률 영역에서 변형률 크기에 따른 탄성계수 결정이 가능한 공내재하시험이 사용되나 전 변형률 영역에서의 탄성계수 변화를 측정하지 못하고,,하중주파수의 영향,구속압의 영향 등을 엄밀히 평가하지 못하는 단점이 있다. 공진주/비틂전단시험과 같은 실내시험에서는 저변형률 및 중간변형률을 포함하는 전변형률 영역에서의 탄성계수 측정이 가능하나 불교란시료의 채취와 시료의 대표성 확보가 매우 어려운 단점이 있다. 따라서 보다 엄밀한 현장지반의 변형률 크기에 따른 탄성계수 결정을 위하여는 각각의 실내시험과 현장시험에서의 신뢰성 있는 변형률 측정범위, 작용되는 응력의 크기, 시험이 수행되는 하중주파수 차이 등을 효과적으로 결합하여 사용하여야 한다. 본 논문에서는 지반의 비선형 변형특성을 현장 및 실내시험 결과를 효과적으로 결합하여 사용하는 방법을 제시하고, 화강풍화토 지반에서 현장시험으로 크로스흘과 공내재하시험을, 실내시험으로는 공진주/비틂 전단시험을 수행하여 현장지반의 변형특성을 결정하고, 각 시험법들의 장.단점과 신뢰성 있는 시험범위를 검토하였다. 마지막으로, 현장지반의 비선형 변형특성 평가 절차를 제시하였다.

  • PDF

FEM을 이용한 상용차용 S-cam 브레이크슈의 구조해석 (Structural Analysis of S-cam Brake Shoe for Commercial Vehicle by FEM)

  • 서창민;지현철
    • 한국해양공학회지
    • /
    • 제23권4호
    • /
    • pp.69-77
    • /
    • 2009
  • Structural analysis of a brake shoe for commercial vehicle was performed using finite element method. Since the strength of a brake shoe is affected by the magnitude and distribution shape of the contact pressure with the drum, the contact pressure between the shoe friction material and drum was calculated using a 2-Dimensional non-linear contact analysis in a state. And the brake was actuated by input air pressure and the drum of it was calculated both stationary and dynamic based on forced torque applied to the drum during the static state analysis. The results of the above analysis were then used as the load boundary conditions for a 3-Dimensional shoe model analysis to determine the maximum strain on the shoes. In the analysis model, the values of tensile test were used for the material properties of the brake shoes and drum, while the values of compression test were used for the friction material. We assumed it as linear variation, even though the properties of friction material were actually non-linear. The experiments were carried out under the same analysis conditions used for fatigue test and under the same brake system which equipped with a brake drum based on the actual axle state in a vehicle. The strains were measured at the same locations where the analysis was performed on the shoes. The obtained results of the experiment matched well with those from the analysis. Consequently, the model used in this study was able to determine the stress at the maximum air pressure at the braking system, thereby a modified shoe model in facilitating was satisfied with the required endurance strength in the vehicle.

Study on the performance of concrete-filled steel tube beam-column joints of new types

  • Liu, Dianzhong;Li, Hongxian;Ren, Huan
    • Computers and Concrete
    • /
    • 제26권6호
    • /
    • pp.547-563
    • /
    • 2020
  • In this paper, the influence of axial compression ratio on the mechanical properties of new type joints of side span of rectangular concrete-filled steel tubular column-H-type steel beam is studied. Two new types of side-span joints of rectangular concrete-filled steel tubular column-H-type steel beam are designed and quasi-static tests of five new type joints with 1:2 scale reduction ratios are performed. The axial compression ratio of joint JD1 is 0.3, 0.4 and 0.5, and the axial compression ratio of joint JD2 is 0.3 and 0.5. In the joint test, different axial forces were applied to the top of the column according to different axial compression ratios, and low-cyclic reciprocating load was applied on the beam. The stress and strain distribution, beam and column deformation, limit state, failure process, failure mechanism, stiffness degradation, ductile deformation and energy dissipation capacity of the joint were measured and analyzed. The results show that: with the increase of axial compression ratio, the ultimate bearing capacity of the joint decreases slightly, the plastic deformation decreases, and the stiffness and ductility decrease. According to the energy dissipation curve of the specimen, the equivalent damping coefficient also increases with the increase of axial compression ratio in a certain range, indicating that the increase of axial compression ratio can improve the seismic performance of the joint to a certain extent. The finite element method is used to simulate the joint test, and the test results are in good agreement with the simulation results.

Effect of stress-strain curve changing with equal channel angular pressing on ultimate strength of ship hull stiffened panels

  • Sekban, Dursun Murat;Olmez, Hasan
    • Structural Engineering and Mechanics
    • /
    • 제78권4호
    • /
    • pp.473-484
    • /
    • 2021
  • Similar to other structures, ultimate strength values showing the maximum load that the structure can resist without damaging has great importance on ships. Therefore, increasing the ultimate strength values will be an important benefit for the structure. Low carbon steels used in ships due to their low cost and good weldability. Improving the ultimate strength values without interfering with the chemical composition to prevent of the weldability properties of these steels would be very beneficial for ships. Grain refinement via severe plastic deformation (SPD) is an essential strengthening mechanism without changing the chemical composition of metallic materials. Among SPD methods, equal channel angular pressing (ECAP) is one of the most commonly used one due to its capacity for achieving bulk ultrafine-grained (UFG) materials. When the literature is examined, it is seen that there is no study about ultimate strength calculation in ships after ECAP. Therefore, the mean purpose of this study is to apply ECAP to a shipbuilding low carbon steel to be able to achieve mechanical properties and investigate the alteration of ship hull girder grillage system's ultimate strength via finite element analysis approach. A fine-grained (FG) microstructure with a mean grain size of 6 ㎛ (initial grain size was 25 ㎛) was after ECAP. This microstructural evolution brought about a considerable increase in strength values. Both yield and tensile strength values increased from 280 MPa and 425 MPa to about 420 MPa and 785 MPa, respectively. This improvement in the strength values reflected a finite element method to determine the ultimate strength of ship hull girder grillage system. As a result of calculations, it was reached significantly higher ultimate strength values (237,876 MPa) compared the non-processed situation (192,986 MPa) on ship hull girder grillage system.