• 제목/요약/키워드: EnergyPlus

검색결과 467건 처리시간 0.023초

시뮬레이션 입력값 라이브러리 구축 (The Development of the Simulation Input Library)

  • 강수현;유지석;백승효;조영흠;김광우
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.287-292
    • /
    • 2011
  • It has found that the using library base on criteria of a foreign country resulted in problem of reliability. In order to obtain reliable result, it was necessary to develop the simulation input library based on domestic condition. So, this study was conducted for making the library in accordance with domestic condition when doing simulation modeling about the exist and new buildings. The range of library were consist of material, facility systems, schedules and weather data. And Energy Plus program was used when making library. We hope that the developed library will contribute to reliability when simulating exist and new buildings.

  • PDF

신재생에너지 설비 설계방안 개발 및 시뮬레이션 사례 연구 (Development of a Renewable Energy Facility Design and Its Simulation Case Study)

  • 신영기;김은주;김태형
    • 설비공학논문집
    • /
    • 제25권8호
    • /
    • pp.464-470
    • /
    • 2013
  • Economic feasibility was conducted regarding the regulation that dictates obligatory installation of renewable energy facilities in small proportion. A concern is how to allocate the capacities of candidate facilities (solar collectors, PV cells and geothermal heat pumps) with minimum cost, and meet the obligatory energy supply proportion. A design rule has been developed, with which a designer can tune his or her design strategy between installation cost and LCC. This was derived mainly from documents regarding the KEMCO installation guide. It was concluded that PV was the cheapest, with respect to installation cost, but a geothermal heat pump was the most recommended, when LCC was also taken into account. The proposed design result was also confirmed, by simulation results obtained from Energy Plus.

단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가 (Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House)

  • 손병후;이수인;강재식
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권4호
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

군사시설 내 지열 히트펌프 시스템 적용에 따른 에너지 성능과 비용 절감 효과 평가 (Energy Performance and Cost Assessment for Implementing GroundSource Heat Pump System in Military Building)

  • 손병후;조경주;조동우
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권4호
    • /
    • pp.45-57
    • /
    • 2022
  • The Ministry of National Defense of the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of military facilities and to promote green growth policy in military sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. This paper analyzed energy performance and energy cost on the conventional heating and cooling system (baseline scenario) and three different alternative scenarios (ALT 1, ALT 2 and ALT 3) applied in a hypothetical military building. A building modeling and simulation software (DesignBuilder V6.1) with EnergyPlus calculation engine was used to calculate the energy consumption for each scenario. Overall, when the GSHPs are applied to both space airconditioning and domestic hot water (DHW) production, Alt-2 and Alt-3, the amount of energy consumption for target building can be greatly reduced. In addition, when the building envelope performance is increased like Alt-3, the energy consumption can be further reduced. The annual energy cost analysis showed that the baseline was approximately 161 million KRW, while Alt-3 was approximately 33 million KRW. Therefore, it was analyzed that the initial construction cost increase could be recovered within about 6.7 years for ALT 3. The results of this study can help decision-makers to determine the optimal strategy for implementing GSHP systems in military buildings through energy performance and initial construction cost assessment.

외피의 Passive Design 요소와 신재생에너지를 적용한 생물안전 밀폐시설의 에너지 시스템 개선방안 연구 (A Study on the Energy Improvement Plan of using Passive Design with Exterior Envelopes and Renewable Energy for Bio Safety Labotratory)

  • 황지현;범도;홍진관
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.491-496
    • /
    • 2014
  • In general, the entire air supply of a bio-safety laboratory (BSL) should be exhausted on the outside to ensure bio-safety, and the air conditioning system should always be operated to maintain a difference in the room pressure. As a result, the annual energy consumption of such a building is approximately five or ten times higher than that of an office building of the same magnitude. Thus, this study applies an actual operating system that targets BSL. The energy consumption is analyzed using the Energy Plus V8.0 program (an energy analysis program), and five kinds of cases that depend on the energy consumption of the basic BSL system are also analyzed. As a result, the energy consumption in Case 1 (basic system) is of 324.95 GJ. When the basic system of Case 1 is compared to that in Case 2 (basic system+passive design with exterior envelopes), an annual energy savings of is 6.9% is achieved. For Case 3 (basic system+Photovoltaic, PV) 12.7% is achieved, and for Case 4 (Solar Geothermal Hybrid System of renewable energy, SGHS) 49.5% is achieved. If a passive design with exterior envelopes and renewable energy system (PV+SGHS) is combined, as in Case 5, the energy consumption would be 118.15 GJ. Therefore, when this last system is compared to a basic system, the passive design with exterior envelopes and renewable energy system (PV+SGHS) can reduce energy consumption by 63.6%.

Biochemical Characterization of Alkaliphilic Cyclodextran Glucanotransferase from an Alkaliphilic Bacterium, Paenibacillus daejeonensis

  • Yang, So-Jin;Ko, Jin-A;Kim, Hae-Soo;Jo, Min-Ho;Lee, Ha-Nul;Park, Bo-Ram;Kim, Young-Min
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권12호
    • /
    • pp.2029-2035
    • /
    • 2018
  • Cycloisomaltooligosaccharide glucanotransferase (CITase) was isolated from alkaliphilic Paenibacillus daejeonensis via an amino acid homology search for the reported CITase. The recombinant alkaliphilic CITase (PDCITase) from P. daejeonensis was expressed in an Escherichia coli expression system and purified as a single protein band of 111 kDa. PDCITase showed optimum activity at pH 8.0 and retained 100% of activity within a broad pH range (7.0-11.5) after 18 h, indicating alkaliphilic or alkalistable CITase properties. In addition, PDCITase produced CI-7 to CI-17, CI-18, and CI-19, which are relatively large cycloisomaltooligosaccharides yet to be reported. Therefore, these large cycloisomaltooligosaccharides can be applied to the improvement of water solubility of pharmaceutical biomaterials.

EFFECTS OF HIGH BY-PRODUCT DIETS CONTAINING RICE BRAN AND BEET PULP ON THE SITE AND EXTENT OF DIGESTION AND MICROBIAL SYNTHESIS IN STEERS

  • Zhao, Y.;Taniguchi, K.;Obitsu, T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제9권6호
    • /
    • pp.655-665
    • /
    • 1996
  • The effects of feeding rice bran and beet pulp mixtures on the site and extent of digestion and microbial synthesis in fattening steers were studied. Three Holstein steers fitted with ruminal, duodenal and ileal cannulas were fed four diets in a $4{\times}3$ Youden square design. The four diets consisted of 15% Italian ryegrass hay and 85% concentrate as a control diet which included 72% rolled barley, 20% rice bran plus 40% beet pulp, 30% rice bran plus 30% beet pulp or 40% rice bran plus 20% beet pulp. All diets provided 1.8 times digestible energy required for maintenance. The digestibility of fat in the small intestine (% of flow) showed an increase with rice bran content among the by-product diets. Digestibility of structural carbohydrate both in the rumen and the whole digestive tract decreased linearly with rice bran content. The digestibility of nonstructural carbohydrate was not affected by rice bran content, but that of nonstructural, nonstarch polysaccharides was higher in the rumen and lower in the large intestine for the by-product diets than for the control diet. A rice bran content of more than 30% in the by-product diets severely inhibits ruminal microbial synthesis and digestible energy intake in fattening steers.

탄소저감을 위한 3D BIM 기반 건물 에너지 효율화 방안 (3D BIM-based Building Energy Efficiency Solution for Carbon Emission Reduction)

  • 이동환;권기정;신주호;박승희
    • 대한토목학회논문집
    • /
    • 제33권3호
    • /
    • pp.1235-1242
    • /
    • 2013
  • 본 논문에서는 건물 내 HVAC시스템의 소비에너지 효율화를 목표로 한다. 이를 위해 건물 에너지 시뮬레이션과 유전알고리즘을 이용하여 HVAC시스템 내 급기 온도에 대한 제어 스케줄을 도출하였다. 연구 대상 건물은 90년대에 지어져 BIM이 구축되어 있지 않아 대성건물의 BIM을 구축하였고, 그 정보를 에너지 시뮬레이션 프로그램에 입력하여, 대상건물에 대한 에너지 시뮬레이션 모델을 구축하였다. 또한 실측한 소비에너지양 정보와 비교하여 대상건물 에너지 시뮬레이션을 실제 에너지 소비량 유사하게 보정하였다. 수정된 건물 에너지 시뮬레이션 모델과 유전자 알고리즘을 이용하여 에너지 효율화 급기 온도 스케줄이 작성되었다. 대상 건물에 적용되었을 때 에너지 절감 효과는 3%로 나타났다. 아직 이 분야는 설비의 제어 기법에 관한 연구가 미진하고, 주로 관리자의 경험을 통해 관리되는 측면이 있어, 에너지 시뮬레이션 프로그램에 의한 기법 개발 및 그에 대한 효과의 검증을 토대로 에너지 절감 기법에 대한 연구 및 개발이 필요하다. 본 연구는 HVAC system 제어 기법에 시발점이 될 것이다.