• 제목/요약/키워드: Energy supply and demand

Search Result 526, Processing Time 0.031 seconds

Analysis of Determinants of Carbon Emissions Considering the Electricity Trade Situation of Connected Countries and the Introduction of the Carbon Emission Trading System in Europe (유럽 내 탄소배출권거래제 도입에 따른 연결계통국가들의 전력교역 상황을 고려한 탄소배출량 결정요인분석)

  • Yoon, Kyungsoo;Hong, Won Jun
    • Environmental and Resource Economics Review
    • /
    • v.31 no.2
    • /
    • pp.165-204
    • /
    • 2022
  • This study organized data from 2000 to 2014 for 20 grid-connected countries in Europe and analyzed the determinants of carbon emissions through the panel GLS method considering the problem of heteroscedasticity and autocorrelation. At the same time, the effect of introducing ETS was considered by dividing the sample period as of 2005 when the European emission trading system was introduced. Carbon emissions from individual countries were used as dependent variables, and proportion of generation by each source, power self-sufficiency ratio of neighboring countries, power production from resource-holding countries, concentration of power sources, total energy consumption per capita in the industrial sector, tax of electricity, net electricity export per capita, and size of national territory per capita. According to the estimation results, the proportion of nuclear power and renewable energy generation, concentration of power sources, and size of the national territory area per capita had a negative (-) effect on carbon emissions both before and after 2005. On the other hand, the proportion of coal power generation, the power supply and demand rate of neighboring countries, the power production of resource-holding countries, and the total energy consumption per capita in the industrial sector were found to have a positive (+) effect on carbon emissions. In addition, the proportion of gas generation had a negative (-) effect on carbon emissions, and tax of electricity were found to have a positive (+) effect. However, all of these were only significant before 2005. It was found that net electricity export per capita had a negative (-) effect on carbon emissions only after 2005. The results of this study suggest macroscopic strategies to reduce carbon emissions to green growth, suggesting mid- to long-term power mix optimization measures considering the electricity trade market and their role.

Analysis of Causes of and Solutions to the Stack Effect by Vertical Zoning of High-rise Buildings (초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석)

  • Shin, Sang Wook;Ryu, Jong Woo;Jeong, Hee Woong;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.5
    • /
    • pp.483-493
    • /
    • 2021
  • Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.

Study on the Estimation of Long Life Cycle and Reliability Tests for Epoxy Insulation Busway System (에폭시 박막 절연형 버스웨이 시스템의 장기 수명 및 신뢰성 평가에 관한 연구)

  • Jang, Dong-Uk;Park, Seong-Hee;Lee, Kang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.261-268
    • /
    • 2018
  • The use of electric cable was limited due to the installation time and large space as the increase of power demand and load quantity in side line. In order to solve these problems, the application of busway system which can supply the large current was increasing. But it was lack of methods of performance tests to evaluate the reliability and results of test for busway system. In this paper, we presented items to evaluate the reliability test for epoxy coated busway system with reference to IEC 61349-6. In addition, we proposed items to evaluate the reliability and long term life cycle test for the epoxy coated busway system. The combined acceleration deterioration test that reflects actual conditions of the survey as much as possible was conducted considering both thermal and electrical stresses. The deterioration condition was selected to satisfy fifty years life expectation and the insulation performance verification test of the busway system confirmed the long term life prediction. Furthermore, as test items for reliability assessment of compliance with the environment for the use of temperature, humidity and load current where busway system was installed, thermal overload test, water immersion test, cold shock temperature test and thermal cycle test were performed. And we examined changes in characteristics and abnormality after tests. From results, the test items presented to evaluate performance and reliability of the epoxy insulated busway system were confirmed to be appropriate in this paper, and the performance of the product was also confirmed to be excellent for reliability tests.

Analysis on the Recent Simulation Results of the Pilot Carbon Emission Trading System in Korea (국내 온실가스 배출권거래제도 시범도입방안에 관한 소고(小考))

  • Lee, Sang-Youp;Kim, Hyo-Sun;Yoo, Sang-Hee
    • Environmental and Resource Economics Review
    • /
    • v.13 no.2
    • /
    • pp.271-300
    • /
    • 2004
  • We investigate the two recent simulations of the proto-type domestic carbon emission trading system in Korea and draw some policy implications. The first simulation includes the 5 electric power companies based on baseline and credit. But the second one is with the 7 energy-intensive companies based on cap and trade. The voluntary approaches in this paper revealed the instability of market equilibrium, i.e., price volatility or distortion, excess supply or demand. These phenomena stems from excess incentives to the players, asymmetric information, players' irresponsible strategic behaviors, and non acquaintance of trading system. This paper suggests the basic design for domestic carbon trading system in future and a stepwise introduction strategy for it including the incentive auction scheme, the total quantity of incentive needed, and how to finance it. Meantime, the further simulations on the various sectors based on voluntary participation must be essential for learning experiences and better policy design.

  • PDF

Risk Assessment of Stationary Hydrogen Refueling Station by Section in Dispenser Module (고정식 수소충전소에서의 Dispenser Module 내 구역별 위험성 평가)

  • SangJin Lim;MinGi Kim;Su Kim;YoonHo Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.1
    • /
    • pp.76-85
    • /
    • 2023
  • Demand for hydrogen as a renewable energy resource is increasing. However, unlike conventional fossil fuels, hydrogen requires a dedicated refueling station for fuel supply. A risk assessment of hydrogen refueling stations must be undertaken to secure the infrastructure. Therefore, in this study, a risk assessment for hydrogen refueling stations was conducted through both qualitative and quantitative risk assessments. For the qualitative evaluation, the hydrogen dispenser module was evaluated as two nodes using the hazard and operability (HAZOP) analysis. The risk due to filter clogging and high-pressure accidents was evaluated to be high according to the criticality estimation matrix. For the quantitative risk assessment, the Hydrogen Korea Risk Assessment Module (Hy-KoRAM) was used to indicate the shape of the fire and the range of damage impact, and to evaluate the individual and social risks. The individual risk level was determined of to be as low as reasonably practicable (ALARP). Additional safety measures proposed include placing the hydrogen refueling station about 100m away from public facilities. The social risk level was derived as 1E-04/year, with a frequency of approximately 10 deaths, falling within the ALARP range. As a result of the qualitative and quantitative risk assessments, additional safety measures for the process and a safety improvement plan are proposed through the establishment of a restricted area near the hydrogen refueling station.

Investigation of PWR Spent Fuels for the Design of a Deep Geological Repository (심층처분시스템 설계를 위한 경수로 사용후핵연료 현황 분석)

  • Cho, Dong-Keun;Kim, Jungwoo;Kim, In-Young;Lee, Jong-Youl
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.3
    • /
    • pp.339-346
    • /
    • 2019
  • Based on the $8^{th}$ Basic Plan for Electric Power Demand and Supply, an estimation has been made for inventories and characteristics of spent fuel (SF) to be generated from existing and planned nuclear power plants. The characteristics under consideration in this study are dimensions, fuel array, $^{235}U$ enrichment, discharge burnup, and cooling time for each fuel assembly. These are essentially needed for designing a disposal facility for SFs. It appears that the anticipated quantity by the end of 2082 is about 62,500 assemblies for PWR SFs. The inventories of Westinghouse-type and Korean-type SFs were revealed to be 60% and 40%, respectively as of the end of 2018. The proportion of SFs with initial $^{235}U$ enrichment below 4.5 weight percent (wt%) was shown to be approximately 90% in total as of the end of 2018. As of 2077, more than 97% of SFs generated from Westinghouse-type nuclear reactors were shown to have cooling time of over 50 years. As of 2125, more than 98% of SFs generated from Korean-type nuclear reactors were shown to have cooling time of over 45 years. Based on these results, for the efficient design of a disposal system, it is reasonable to adopt two types of reference spent fuel. SF of KSFA with $^{235}U$ enrichment of 4.5 wt%, discharge burnup of 55 GWd/tU, and cooling time of 50 years was determined as reference fuel for Westinghouse-type SFs; SF of PLUS7 with $^{235}U$ enrichment of 4.5 wt%, discharge burnup of 55 GWd/tU, and cooling time of 45 years was determined as reference fuel for Korean-type SFs.

Effect of Seeds Treatment on Germinablity of Tetragonia Tetragonides Seeds (번행초의 대량번식을 위한 종자처리가 발아력에 미치는 영향)

  • Kang, Jum-Soon;Park, Eun-Ji;Kim, So-Hee;Heo, You;Park, Young-Hoon;Choi, Young-Whan;Son, Beung-Gu;Lim, Woo-Taik;Suh, Jeong-Min
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.771-780
    • /
    • 2014
  • Tetragonia tetragonides is a medicinal plant native to ocean sand soil of southern provinces and has significant effects on the prevention and curing of gastroenteric disorders. Despite of its popularity, supply of the plant has never met the level of demand because of the absence of an adequate culturing method. The present study, thereby, was conducted for classifying the plants with geographically different characteristics, studying growth habits, developing a new culturing method and establishing a large scale propagation system of selected superior individual plants. The study was also aimed for revealing optimum conditions for seed treatment, fertilization, and efficient culturing system and thereby, for utilizing the plant as a new income source for rural communities. The seed was elongated with size of 2.6 mm (width) ${\times}$ 1.8 mm (length). No difference in seed size was observed depending on different inhabitate. Each flower produced about 4.5~4.8 seeds. Germination rate was high for seeds matured for 40 days after fertilization, but deceased to 50% for seeds matured only for 20 or 30 days. Seed dormancy lasted 6 months and seed storage at humid $5^{\circ}C$ facilitated germination. Mechanical obstruct of seed germination was due to seed coat and removal of seed coat enhanced the germination rate. Optimum temp. for seed storage was $5^{\circ}C$, and high germination rate was maintained for 350 days. However, for stratification condition or at room temperature, germination was significantly reduced as storage time increased Optimum treatment of plant growth regulators was soaking in $GA_3$ 250 mg/L for 1 hr. The priming treatment with 50 mM $Ca(NO_3)_2$ at $20^{\circ}C$ for two days improved the seed germination with 10% compared to non-treated control. The treatment of 20% NaOCl for 3 hr. improved the seed germination rate up to 10% and 1 day ahead.

A Study on the Deterioration Process of 22kV Power Cables in Operation (운전 중인 상태에 있는 22kV 전송선로 케이블의 열화 과정해석에 대한 연구)

  • Lee, Kwan-Woo;Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.3
    • /
    • pp.127-133
    • /
    • 2013
  • As an essential part of current industrial society, electric power energy is contantaly increasing in pace with the development of science and technology. In order to meet the demand of electric power, power facilities which take care of the higher voltage and bigger capacity is required. To produce and supply electric power on a sound basis the electric facilities should operate with reliability. To prevent disasters in advance, the high quality facilities should be manufactured, and a constant management should be done. When the power facilities cause accidents, the result is huge national deficits. Since the power facilities play a pivotal role in the key industry of national infrastructures of they should operate for a long time in maintaining a stable state, and the accidents can be prevented in advance. The lifetime of a power cable is considered to be 30 years at the time of manufacture, but in real fields, accidents of cable occur 8-12 years from the start of operation, resulting in a heavy loss of properties. In this paper, we will show that we have found out the cause and process of the deterioration of 22kV cable systems in operation. The result is that the process of deterioration does not follow the Weibull distribution only ; but rather, after the heat deterioration the Weibull distributed deterioration comes, then the cable is destroyed due to the partial discharge resulting from the Weibull distributed deterioration.

Experimental Results of New Ion Source for Performance Test

  • Kim, Tae-Seong;Jeong, Seung-Ho;Jang, Du-Hui;Lee, Gwang-Won;In, Sang-Yeol
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.269-269
    • /
    • 2012
  • A new ion source has been designed, fabricated, and installed at the NBTS (Neutral Beam Test Stand) at the KAERI (Korea Atomic Energy Research Institute) site. The goalis to provide a 100 keV, 2MW deuterium neutral beam injection as an auxiliary heating of KSTAR (Korea Super Tokamak Advanced Research). To cope with power demand, an ion current of 50 A is required considering the beam power loss and neutralization efficiency. The new ion source consists of a magnetic cusp bucket plasma generator and a set of tetrode accelerators with circular copper apertures. The plasma generator for the new ion source has the same design concept as the modified JAEA multi-cusp plasma generator for the KSTAR prototype ion source. The dimensions of the plasma generator are a cross section of $59{\times}25cm^2$ with a 32.5 cm depth. The anode has azimuthal arrays of Nd-Fe permanent magnets (3.4 kG at surface) in the bucket and an electron dump, which makes 9 cusp lines including the electron dump. The discharge properties were investigated preliminarily to enhance the efficiency of the beam extraction. The discharge of the new ion source was mainly controlled by a constant power mode of operation. The discharge of the plasma generator was initiated by the support of primary electrons emitted from the cathode, consisting of 12 tungsten filaments with a hair-pin type (diameter = 2.0 mm). The arc discharge of the new ion source was achieved easily up to an arc power of 80 kW (80 V/1000 A) with hydrogen gas. The 80 kW capacity seems sufficient for the arc power supply to attain the goal of arc efficiency (beam extracted current/discharge input power = 0.8 A/kW). The accelerator of the new ion source consists of four grids: plasma grid (G1), gradient grid (G2), suppressor grid (G3), and ground grid (G4). Each grid has 280 EA circular apertures. The performance tests of the new ion source accelerator were also finished including accelerator conditioning. A hydrogen ion beam was successfully extracted up to 100 keV /60 A. The optimum perveance is defined where the beam divergence is at a minimum was also investigated experimentally. The optimum hydrogen beam perveance is over $2.3{\mu}P$ at 60 keV, and the beam divergence angle is below $1.0^{\circ}$. Thus, the new ion source is expected to be capable of extracting more than a 5 MW deuterium ion beam power at 100 keV. This ion source can deliver ~2 MW of neutral beam power to KSTAR tokamak plasma for the 2012 campaign.

  • PDF

Impacts of Low-priced of Industrial Electricity and Loose Environment Regulations on Investment Incentives of Inward Foreign Direct Investment of the Manufacturing Industries in Korea (외국계 제조업체 투자유인으로서의 저렴한 전기요금과 느슨한 환경규제 영향력)

  • Kim, Jung A;Lee, Hee Yeon
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.231-248
    • /
    • 2014
  • The role of the foreign direct investment is very crucial for the regional economic growth nowadays. The inward FDI in Korea has been increased since the Act of foreigner investment promotion in 1998. The municipal and national government have designated the special industrial zones and supported the diverse incentives for the foreign investment companies. The service sector had a large share of inward FDI. However, manufacturing sector overtook the service sector as the largest FDI in 2009. This study focuses on the greenfield manufacturing FDI, which was established from 1999 to 2012 in Korea. In order to find out the impacts of low-priced industrial electricity and loose environmental regulations on choosing Korea, this paper did in-depth interviews with MOTIE, Korea industrial complex, Korea Trade-Investment Promotion Agency, some FDI companies. Investment incentives such as low price of domestic industrial electricity strongly affect why manufacturing FDI companies choose Korea to invest. The Korean government has also acknowledges that low-price policy can internationally compete to attract FDI. There is a possibility that FDI energy-guzzling industrial companies may choose for Korea to use the low-priced electricity, raising the issue of supply-demand of electricity of Korea in the future.

  • PDF